LSLu Sun

Lu Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lu Sun has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of Fault Current Limiter Reactance Based on Joint Simulation and Penalty Function-Constrained Algorithm

    by Jun Zhao, Chao Xing, Zhigang Zhang, Boyuan Liang, Lu Sun, Bin Wei, Weiqi Qin, Shuguo Gao

    This paper proposes a novel optimization method for fault current limiter (FCL) reactance configuration based on joint simulation and penalty function constraint optimization. By integrating MATLAB and ATP for joint simulation, the method accurately derives the constraint conditions of the objective optimization function, providing critical data support for the optimization process. To address the challenges of high computational complexity and solution difficulties in constrained optimization, the Penalty Function Method (PFM) is employed to transform the original constrained optimization problem into a standard unconstrained optimization problem, significantly reducing computational complexity and ensuring the feasibility of the solution. On this basis, the Gravitational Search Algorithm (GSA) is applied to compute the optimal reactance value. Through comparative analysis of engineering case studies, the superiority of the GSA over the Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) in optimization performance is validated, further confirming the accuracy and efficiency of the proposed method. The results indicate that this method not only achieves precise calculation results but also significantly improves computational efficiency. Moreover, the integration of PFM and GSA demonstrates excellent robustness, providing reliable technical support for the optimized deployment of fast-switching fault current limiters in large-scale power grids.


  • Open Access

    Research on the Influence of Compression and Offset of Cushion Blocks on the Axial Strength of Transformers

    by Lu Sun, Shuguo Gao, Tianran Li, Jiaxin Yao, Ping Wang, Jianhao Zhu

    The instability of the winding-cushion structure is one of the primary causes of transformer failures. Insulation cushion compression and offset are the predominant forms leading to structural instability. Therefore, this paper, using the SFSZ7-31500/110 transformer as an example, first derives the theoretical formula for mechanical stress calculation. It clarifies the key influencing parameters of the winding-cushion block structure on the axial bending stress of the winding. Subsequently, an electromagnetic force finite element calculation model is established to obtain the axial force distribution in the winding and the distribution of unbalanced displacement during short-circuit processes. Based on the force and offset distribution, a specific cushion block compression and offset test platform is constructed. By setting different cushion block variables, the effects of cushion block unbalanced height and cushion block offset on the winding’s bending elastic modulus are determined. Finally, a simulation model for stress calculation of the winding-cushion block structure is established, revealing the influence pattern of cushion block compression and offset instability on the axial strength of the winding. The results of this study indicate that the greater the uneven cushion block height, the lower the axial strength of the winding. Under the same cushion block offset angle, winding structures with non-uniform cushion block offsets exhibit the worst axial stability. When the offset angles are 30°, 45°, and 60°, the maximum axial bending stress of the winding increases by 1.73%, 3.46%, and 7.82%, respectively. Increasing the offset angle exacerbates the decrease in the axial strength of the winding up to a certain extent. The findings in this study have significant implications for enhancing a transformer’s short-circuit resistance.

  • Open Access

    Research on the Distribution Characteristics of Transformer Axial Vibration under Short-Circuit Conditions Considering Damping Parameters

    by Shuguo Gao, Lu Sun, Yuan Tian, Hongliang Liu

    The existing research on the distribution characteristics of displacement and acceleration of the transformer axial vibration under short-circuit conditions is based on ignoring the damping parameters. An accurate description of the axial distribution characteristics of the windings, especially for the axial vibration of the winding under short-circuit conditions, has a poor effect. In this paper, the damping, stiffness, and mass parameters between windings are comprehensively considered, and the classical “mass-spring-damping” axial vibration mathematical model of transformer windings is established. After solving, the natural frequency, main mode shape, displacement, and acceleration of each wire cake of the multi-degree-of-freedom (multi-DOF) vibration system were quickly obtained. The relationship between the axial displacement and acceleration of the wire cake and the axial deformation of the transformer winding was discussed, and the transformer winding axis was summarized as well as characteristics of the vibration distribution.