Yuan Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuan Tian has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Shuguo Gao
Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China
4 shared publications - Lu Sun
Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China
2 shared publications - Bin Wei
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
1 shared publication - Chenmeng Xiang
Electric Power Research Institute of State Grid Hebei Electric Power Company, Shijiazhuang 050000, China
1 shared publication - Fuyun Teng
Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
1 shared publication - Guoming Ma
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication
Latest Publications
- Open Access
Impact of Adding Fast Switching Fault Current Limiter (FSFCL) to the Neutral Point of 220 kV Transformer
In recent years, as the power grid continues to expand, the issue of asymmetrical short-circuit currents exceeding limits on the 220 kV medium-voltage side has become increasingly severe, and traditional current-limiting methods have certain limitations. Therefore, this paper explores the potential benefits and feasibility of installing a Fast Switching Fault Current Limiter (FSFCL) at the neutral point of a 220 kV transformer to effectively limit asymmetrical short-circuit currents on the medium-voltage side. The paper first analyzes the current-limiting performance of the FSFCL under different installation configurations, transformer operating conditions, and fault conditions through theoretical calculations. Subsequently, through simulation studies, the impact of different limiting reactance values on the overvoltage effect at the neutral point is discussed. The results show that the installation of the FSFCL has a significant effect on suppressing the asymmetrical short-circuit current on the medium-voltage side of the transformer, but this measure has also led to an increase in the voltage at the grounded neutral point. Finally, taking the No. 2 main transformer of a certain 220 kV substation as an example, to achieve the expected current-limiting effect, the limiting reactance value of the FSFCL needs to be at least 4 ohms. At this reactance value, the overvoltage level at the neutral point remains well below the withstand limit of its insulating material. Additionally, given the existing overvoltage protection devices at the neutral point, no further overvoltage protection measures are required.
Open AccessImpact of Adding Fast Switching Fault Current Limiter (FSFCL) to the Neutral Point of 220 kV Transformer
In recent years, as the power grid continues to expand, the issue of asymmetrical short-circuit currents exceeding limits on the 220 kV medium-voltage side has become increasingly severe, and traditional current-limiting methods have certain limitations. Therefore, this paper explores the potential benefits and feasibility of installing a Fast Switching Fault Current Limiter (FSFCL) at the neutral point of a 220 kV transformer to effectively limit asymmetrical short-circuit currents on the medium-voltage side. The paper first analyzes the current-limiting performance of the FSFCL under different installation configurations, transformer operating conditions, and fault conditions through theoretical calculations. Subsequently, through simulation studies, the impact of different limiting reactance values on the overvoltage effect at the neutral point is discussed. The results show that the installation of the FSFCL has a significant effect on suppressing the asymmetrical short-circuit current on the medium-voltage side of the transformer, but this measure has also led to an increase in the voltage at the grounded neutral point. Finally, taking the No. 2 main transformer of a certain 220 kV substation as an example, to achieve the expected current-limiting effect, the limiting reactance value of the FSFCL needs to be at least 4 ohms. At this reactance value, the overvoltage level at the neutral point remains well below the withstand limit of its insulating material. Additionally, given the existing overvoltage protection devices at the neutral point, no further overvoltage protection measures are required.
- Open Access
- 15 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (24) , 13289
Research on the Influence of Compression and Offset of Cushion Blocks on the Axial Strength of Transformers
The instability of the winding-cushion structure is one of the primary causes of transformer failures. Insulation cushion compression and offset are the predominant forms leading to structural instability. Therefore, this paper, using the SFSZ7-31500/110 transformer as an example, first derives the theoretical formula for mechanical stress calculation. It clarifies the key influencing parameters of the winding-cushion block structure on the axial bending stress of the winding. Subsequently, an electromagnetic force finite element calculation model is established to obtain the axial force distribution in the winding and the distribution of unbalanced displacement during short-circuit processes. Based on the force and offset distribution, a specific cushion block compression and offset test platform is constructed. By setting different cushion block variables, the effects of cushion block unbalanced height and cushion block offset on the winding’s bending elastic modulus are determined. Finally, a simulation model for stress calculation of the winding-cushion block structure is established, revealing the influence pattern of cushion block compression and offset instability on the axial strength of the winding. The results of this study indicate that the greater the uneven cushion block height, the lower the axial strength of the winding. Under the same cushion block offset angle, winding structures with non-uniform cushion block offsets exhibit the worst axial stability. When the offset angles are 30°, 45°, and 60°, the maximum axial bending stress of the winding increases by 1.73%, 3.46%, and 7.82%, respectively. Increasing the offset angle exacerbates the decrease in the axial strength of the winding up to a certain extent. The findings in this study have significant implications for enhancing a transformer’s short-circuit resistance.
- 15 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (24) , 13289
Open AccessResearch on the Influence of Compression and Offset of Cushion Blocks on the Axial Strength of Transformers
The instability of the winding-cushion structure is one of the primary causes of transformer failures. Insulation cushion compression and offset are the predominant forms leading to structural instability. Therefore, this paper, using the SFSZ7-31500/110 transformer as an example, first derives the theoretical formula for mechanical stress calculation. It clarifies the key influencing parameters of the winding-cushion block structure on the axial bending stress of the winding. Subsequently, an electromagnetic force finite element calculation model is established to obtain the axial force distribution in the winding and the distribution of unbalanced displacement during short-circuit processes. Based on the force and offset distribution, a specific cushion block compression and offset test platform is constructed. By setting different cushion block variables, the effects of cushion block unbalanced height and cushion block offset on the winding’s bending elastic modulus are determined. Finally, a simulation model for stress calculation of the winding-cushion block structure is established, revealing the influence pattern of cushion block compression and offset instability on the axial strength of the winding. The results of this study indicate that the greater the uneven cushion block height, the lower the axial strength of the winding. Under the same cushion block offset angle, winding structures with non-uniform cushion block offsets exhibit the worst axial stability. When the offset angles are 30°, 45°, and 60°, the maximum axial bending stress of the winding increases by 1.73%, 3.46%, and 7.82%, respectively. Increasing the offset angle exacerbates the decrease in the axial strength of the winding up to a certain extent. The findings in this study have significant implications for enhancing a transformer’s short-circuit resistance.
- Open Access
- 31 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11910
Effect of Multiple Reclosing Time Intervals on Axial Vibration of Winding
When a transformer suffers a permanent fault, it will suffer a short-circuit impulse again after reclosing. If the previous vibration of the winding is not attenuated completely and the winding is subjected to a secondary impulse within a short time, the secondary vibration response will have a superposition. The aim of this study was to analyze the effect of the anti-short-circuit ability of operational transformers subjected to a secondary short-circuit current impulse. In this paper, a model is established for calculating axial vibration in transformer windings and effects on the vibration response of windings under different closing phase angles and short-circuit intervals are analyzed. The results show that the vibration acceleration of windings is a V-shaped variation at phase angles from 0° to 180°, reaching the maximum values at 0° and 180° and reaching the minimum value at 90°. When the transformer recloses on a permanent short circuit, due to the superposition effect, the vibration acceleration amplitude of the secondary impulse will be greater than that of the primary impulse, but as the reclosing interval increases, the superposition effect decreases continuously. When the interval is 600 ms, the superposition effect for the vibration acceleration of the secondary impulse attenuates to 83.3%. The superposition effect is not significant after 600 ms. The research provides a theoretical reference for transformer closing-control strategies.
- 31 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11910
Open AccessEffect of Multiple Reclosing Time Intervals on Axial Vibration of Winding
When a transformer suffers a permanent fault, it will suffer a short-circuit impulse again after reclosing. If the previous vibration of the winding is not attenuated completely and the winding is subjected to a secondary impulse within a short time, the secondary vibration response will have a superposition. The aim of this study was to analyze the effect of the anti-short-circuit ability of operational transformers subjected to a secondary short-circuit current impulse. In this paper, a model is established for calculating axial vibration in transformer windings and effects on the vibration response of windings under different closing phase angles and short-circuit intervals are analyzed. The results show that the vibration acceleration of windings is a V-shaped variation at phase angles from 0° to 180°, reaching the maximum values at 0° and 180° and reaching the minimum value at 90°. When the transformer recloses on a permanent short circuit, due to the superposition effect, the vibration acceleration amplitude of the secondary impulse will be greater than that of the primary impulse, but as the reclosing interval increases, the superposition effect decreases continuously. When the interval is 600 ms, the superposition effect for the vibration acceleration of the secondary impulse attenuates to 83.3%. The superposition effect is not significant after 600 ms. The research provides a theoretical reference for transformer closing-control strategies.
- Open Access
- 24 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8443
Research on the Distribution Characteristics of Transformer Axial Vibration under Short-Circuit Conditions Considering Damping Parameters
The existing research on the distribution characteristics of displacement and acceleration of the transformer axial vibration under short-circuit conditions is based on ignoring the damping parameters. An accurate description of the axial distribution characteristics of the windings, especially for the axial vibration of the winding under short-circuit conditions, has a poor effect. In this paper, the damping, stiffness, and mass parameters between windings are comprehensively considered, and the classical “mass-spring-damping” axial vibration mathematical model of transformer windings is established. After solving, the natural frequency, main mode shape, displacement, and acceleration of each wire cake of the multi-degree-of-freedom (multi-DOF) vibration system were quickly obtained. The relationship between the axial displacement and acceleration of the wire cake and the axial deformation of the transformer winding was discussed, and the transformer winding axis was summarized as well as characteristics of the vibration distribution.
- 24 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8443
Open AccessResearch on the Distribution Characteristics of Transformer Axial Vibration under Short-Circuit Conditions Considering Damping Parameters
The existing research on the distribution characteristics of displacement and acceleration of the transformer axial vibration under short-circuit conditions is based on ignoring the damping parameters. An accurate description of the axial distribution characteristics of the windings, especially for the axial vibration of the winding under short-circuit conditions, has a poor effect. In this paper, the damping, stiffness, and mass parameters between windings are comprehensively considered, and the classical “mass-spring-damping” axial vibration mathematical model of transformer windings is established. After solving, the natural frequency, main mode shape, displacement, and acceleration of each wire cake of the multi-degree-of-freedom (multi-DOF) vibration system were quickly obtained. The relationship between the axial displacement and acceleration of the wire cake and the axial deformation of the transformer winding was discussed, and the transformer winding axis was summarized as well as characteristics of the vibration distribution.