DMDario Melodia

Dario Melodia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dario Melodia has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In Vitro Micro-CT Assessment of a Novel Implant–Abutment Connection Under Static and Cyclic Loading

    by Marco Tallarico, Dario Melodia, Lukasz Zadrozny, Carlotta Cacciò, Silvio Mario Meloni, Aurea Immacolata Lumbau, Santo Catapano, Riccardo Baldari, Rafał Molak, Jakub Jaroszewicz, et al.

    The implant–abutment connection (IAC) is a critical determinant of the mechanical and biological performance of dental implants. Connection design and insertion torque may influence fatigue resistance, micromovement, and microgap formation, thereby affecting long-term implant success. This in vitro study evaluated a novel conical implant–abutment connection under controlled mechanical loading conditions. Methods: A sequential in vitro protocol was applied. Mechanical testing was conducted according to ISO 14801:2016 and included static and cyclic loading tests of the KS implant system inserted at two different torque values (35 Ncm and 70 Ncm). High-resolution micro-computed tomography (micro-CT) was performed after mechanical loading to evaluate implant–abutment interface integrity, microstructural alterations, and microgap behavior. Results: Static and cyclic loading tests revealed no observable differences between implants inserted at 35 Ncm and 70 Ncm, with all specimens completing the loading protocols without mechanical failure. Micro-CT analysis showed no evidence of microfractures, permanent deformation, or clinically relevant alterations at the implant–abutment interface. A stable and well-sealed connection was observed for both torque values following mechanical loading. Conclusions: Within the limitations of this in vitro study, the investigated conical implant–abutment connection demonstrated stable mechanical performance and preserved interface integrity after static and cyclic loading, regardless of whether implants were placed at 35 Ncm or 70 Ncm. These findings indicate that, under the present experimental conditions, both torque levels were associated with comparable structural integrity and mechanical stability of the investigated implant–abutment connection. This study should be interpreted as a preliminary experimental investigation, designed to provide descriptive and mechanistic insights rather than statistically powered comparative conclusions. Further long-term clinical trials are required to confirm these preliminary results.

  • Open Access

    The Use of Vacuum Plasma Surface Treatment to Improve Bone Healing and Regeneration in Socket Preservation and GBR: A Case Series with Histological Analysis

    by Marco Tallarico, Michele Troia, Milena Pisano, Silvio Mario Meloni, Dario Melodia, Claudia Della Via, Dolaji Henin, Francesco Mattia Ceruso, Carlotta Cacciò, Aurea Immacolata Lumbau

    Purpose: To evaluate the clinical and histological outcomes of patients that receive implant-supported crowns after vacuum plasma surface treatment (VPST) of biomaterials used in socket preservation (SP) and guided bone regeneration (GBR). Materials and methods: This study was designed as a case series. Patients in need of tooth extraction and socket preservation or guided bone regeneration were enrolled. The socket preservation technique was performed after tooth extraction using a heterologous collagen bone graft and a collagen xenomatrix, both activated with vacuum plasma. Meanwhile, a two-stage horizontal ridge augmentation was performed using a customized titanium mesh and a mix of autologous (untreated) and heterologous (treated) bone grafts, along with a treated collagen membrane. ACTILINK Reborn with Universal Vortex Holder (Plasmapp Co., Ltd., Daejeon, Republic of Korea) was used to treat all biomaterials. The outcome measures were implant and prosthesis failures, complications, and histological examination. Soft and hard tissue samples were collected at the time of implant placement only in patients treated with SP. Results: A total of six patients were treated—three with socket preservation and delayed implant placement, and three with staged GBR. No implant or prosthesis failed. One customized titanium mesh broke after plasma treatment, requiring replacement with a pericardium membrane. No other complications occurred. Histological analysis at three months post-surgery revealed well-vascularized newly formed bone at different stages of maturation with integrated bone graft particles, while the soft tissue appeared to be physiologically structured. Conclusion: VPST may enhance the hydrophilicity of biomaterials, supporting favorable healing outcomes in SP and GBR. Further randomized controlled trials with appropriate sample size calculations are needed to confirm these preliminary results.


  • Open Access

    Histological Analysis of Biological Width and Collagen Fibers Orientation Around Screw-Less, Morse Taper, Hemispherical Base Abutments 8 and 16 Weeks After Implant Uncovering: An Observational Clinical Trial

    by Fabrizio Zaccheo, Giulia Petroni, Marco Tallarico, Cherana Gioga, Raffaella Carletti, Cira Rosaria Tiziana Di Gioia, Vincenzo Petrozza, Silvio Mario Meloni, Dario Melodia, Milena Pisano, et al.

    Objectives: This study aimed to histologically evaluate, in humans, the orientation of collagen fibers around screw-less, Morse taper, hemispherical base abutments. Methods: This study was designed as an observational, case–control, clinical trial to evaluate the histological orientation of collagen fibers around implants. Biopsies of the peri-implant tissue were performed 8 (group A, control) or 16 (group B, test) weeks of implant uncovering, and histologically analyzed under optical microscope using Hematoxylin and Eosin, Masson, and Picro Sirius histochemical staining and a scanning electron microscope. Results: Eight patients were enrolled in this study and 16 biopsies were performed. All the biopsies were correctly analyzed. The histological examination of cross-sectional portions of the tissue taken 8 weeks after implant uncovering showed the almost complete absence of epithelial lining, while the connective tissue bundles in the superficial portion showed a lower circular pattern. The histochemical cross-section examination of the tissue taken 16 weeks after implant uncovering showed the partial presence of non-keratinizing epithelial lining at the implant site and the collagen bundles showed a greater organization, with a circumferential course around the abutment. At 8 weeks, the final histological analysis showed an average height of 1.01 mm for the keratinized epithelium, 0.83 mm for the non-keratinized epithelium, and 1.39 mm for the connective tissue. While, at 16 weeks, the values were 1.20 mm, 0.48 mm, and 1.11 mm, respectively. No statistically significant differences were found between the groups (p > 0.05). Conclusions: Histologically, there were not any differences in the height and profile of the gingiva between 8 and 16 weeks of healing after prosthesis delivery. Greater organization of the collagen fibers with a circumferential course around the abutment was found in the test group (16 weeks) compared with the control group (8 weeks).


  • Open Access

    Histomorphometry of Bone after Intentionally Exposed Non-Resorbable d-PTFE Membrane or Guided Bone Regeneration for the Treatment of Post-Extractive Alveolar Bone Defects with Implant-Supported Restorations: A Pilot Randomized Controlled Trial

    by Roberto Luongo, Marco Tallarico, Elena Canciani, Daniele Graziano, Claudia Dellavia, Marco Gargari, Francesco Mattia Ceruso, Dario Melodia, Luigi Canullo

    Aim: The aim of the present study was to investigate quantitative histological examination of bone reconstructed with non-resorbable high-density polytetrafluoroethylene membrane (d-PTFE), left intentionally exposed in post extraction sockets grafted with anorganic bone material, and removed after four weeks, versus extraction and guided bone regeneration (GBR), performed two months later. Materials and Methods: This study was designed as a multicenter randomized controlled trial of parallel-group design. Patients were selected and consecutively treated in three centers in Italy. Patients randomly received intentionally exposed non-resorbable d-PTFE membrane (group A), or guided bone regeneration (group B), to treat post-extractive alveolar bone defects with implant-supported restorations. Outcomes were: the implant failure, any mechanical and biological complications, patient satisfaction, and qualitative and histomorphometric evaluation of the collected bone samples. Results: Eighteen patients were consecutively enrolled in the trial. Of these, six out of 18 patients were male. All the included patients were treated according to the allocated interventions, and no drop out occurred. No implant failure and no complications were experienced, and all the patients were fully satisfied with the function and aesthetic of their implant-supported restoration, without difference between groups. Morphological analysis revealed no sign of tissue reaction, such as fibrosis or necrosis. Regenerated bone was well mineralized in both groups, but it seemed more mature in group B than in group A. Three samples showed a minimal number of lymphocytes. Several blood vessels of small size occupied the medullary spaces, where the tissue resulted in more maturity, indicating the activity of the tissue in progress. The histomorphometric evaluation showed no statistically significant differences in the tissue volume fractions between the two groups of patients. Conclusions: With the limitation of the present study, buccal plate reconstruction with an intentionally exposed non-resorbable membrane is an effective and easy procedure for regenerating a resorbed buccal bone plate, reducing the need for guided bone regeneration.