Jane Crowley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jane Crowley has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- George Sinclair Dukoff Gordon
The University of Nottingham
5 shared publications - Adolfo Parra-Blanco
NIHR Nottingham Digestive Diseases Biomedical Research Unit, Nottingham University Hospitals NHS Trust, nottingham, United Kingdom of Great Britain and Northern Ireland
2 shared publications - Frank Phillips
NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham
2 shared publications - Ahmed Mohamed Osman
Faculty of Medicine, Ain Shams University, Cairo, Egypt
1 shared publication - Ahmed Osman
The University of Nottingham
1 shared publication - George Gordon
Faculty of Engineering Optics and Photonics Group The University of Nottingham Nottingham United Kingdom
1 shared publication
Latest Publications
- Open Access
A Cost-Effective 3D-Printed Conductive Phantom for EEG Sensing System Validation: Development, Performance Evaluation, and Comparison with State-of-the-Art Technologies
This paper presents the development and validation of a cost-effective 3D-printed conductive phantom for EEG sensing system validation that achieves 85% cost reduction (£48.10 vs. £300–£500) and 48-hour fabrication time while providing consistent electrical properties suitable for standardized electrode testing. The phantom was fabricated using conductive PLA filament in a two-component design with a conductive upper section and a non-conductive base for structural support. Comprehensive validation employed three complementary approaches: DC resistance measurements (821–1502 ), complex impedance spectroscopy at 100 Hz across anatomical regions (3.01–6.4 k with capacitive behavior), and 8-channel EEG system testing (5–11 k impedance range). The electrical characterization revealed spatial heterogeneity and consistent electrical properties suitable for comparative electrode evaluation and EEG sensing system validation applications. To establish context, we analyzed six existing phantom technologies including commercial injection-molded phantoms, saline solutions, hydrogels, silicone models, textile-based alternatives, and multi-material implementations. This analysis identifies critical accessibility barriers in current technologies, particularly cost constraints (£5000–20,000 tooling) and extended production timelines that limit widespread adoption. The validated 3D-printed phantom addresses these limitations while providing appropriate electrical properties for standardized EEG electrode testing. The demonstrated compatibility with clinical EEG acquisition systems establishes the phantom’s suitability for electrode performance evaluation and multi-channel system validation as a standardized testing platform, ultimately contributing to democratized access to EEG sensing system validation capabilities for broader research communities.Open AccessA Cost-Effective 3D-Printed Conductive Phantom for EEG Sensing System Validation: Development, Performance Evaluation, and Comparison with State-of-the-Art Technologies
This paper presents the development and validation of a cost-effective 3D-printed conductive phantom for EEG sensing system validation that achieves 85% cost reduction (£48.10 vs. £300–£500) and 48-hour fabrication time while providing consistent electrical properties suitable for standardized electrode testing. The phantom was fabricated using conductive PLA filament in a two-component design with a conductive upper section and a non-conductive base for structural support. Comprehensive validation employed three complementary approaches: DC resistance measurements (821–1502 ), complex impedance spectroscopy at 100 Hz across anatomical regions (3.01–6.4 k with capacitive behavior), and 8-channel EEG system testing (5–11 k impedance range). The electrical characterization revealed spatial heterogeneity and consistent electrical properties suitable for comparative electrode evaluation and EEG sensing system validation applications. To establish context, we analyzed six existing phantom technologies including commercial injection-molded phantoms, saline solutions, hydrogels, silicone models, textile-based alternatives, and multi-material implementations. This analysis identifies critical accessibility barriers in current technologies, particularly cost constraints (£5000–20,000 tooling) and extended production timelines that limit widespread adoption. The validated 3D-printed phantom addresses these limitations while providing appropriate electrical properties for standardized EEG electrode testing. The demonstrated compatibility with clinical EEG acquisition systems establishes the phantom’s suitability for electrode performance evaluation and multi-channel system validation as a standardized testing platform, ultimately contributing to democratized access to EEG sensing system validation capabilities for broader research communities. - Open Access
- 1 February 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (02) , 026002-16
Ultra-miniature dual-wavelength spatial frequency domain imaging for micro-endoscopy
SignificanceThere is a need for a cost-effective, quantitative imaging tool that can be deployed endoscopically to better detect early stage gastrointestinal cancers. Spatial frequency domain imaging (SFDI) is a low-cost imaging technique that produces near-real time, quantitative maps of absorption and reduced scattering coefficients, but most implementations are bulky and suitable only for use outside the body.AimWe aim to develop an ultra-miniature SFDI system comprising an optical fiber array (diameter 0.125 mm) and a micro camera (1×1 mm package) to displace conventionally bulky components, in particular, the projector.ApproachFirst, we fabricated a prototype with an outer diameter of 3 mm, although the individual component dimensions could permit future packaging to a 90% are feasible for detecting simulated squamous cell carcinoma.ConclusionsThis device shows promise as a cost-effective, quantitative imaging tool to detect variations in optical absorption and scattering as indicators of cancer.
- 1 February 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (02) , 026002-16
Open AccessUltra-miniature dual-wavelength spatial frequency domain imaging for micro-endoscopy
SignificanceThere is a need for a cost-effective, quantitative imaging tool that can be deployed endoscopically to better detect early stage gastrointestinal cancers. Spatial frequency domain imaging (SFDI) is a low-cost imaging technique that produces near-real time, quantitative maps of absorption and reduced scattering coefficients, but most implementations are bulky and suitable only for use outside the body.AimWe aim to develop an ultra-miniature SFDI system comprising an optical fiber array (diameter 0.125 mm) and a micro camera (1×1 mm package) to displace conventionally bulky components, in particular, the projector.ApproachFirst, we fabricated a prototype with an outer diameter of 3 mm, although the individual component dimensions could permit future packaging to a 90% are feasible for detecting simulated squamous cell carcinoma.ConclusionsThis device shows promise as a cost-effective, quantitative imaging tool to detect variations in optical absorption and scattering as indicators of cancer.
- 4 May 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (6) , 2523-2538
Designing and simulating realistic spatial frequency domain imaging systems using open-source 3D rendering software
Spatial frequency domain imaging (SFDI) is a low-cost imaging technique that maps absorption and reduced scattering coefficients, offering improved contrast for important tissue structures such as tumours. Practical SFDI systems must cope with various imaging geometries including imaging planar samples ex vivo, imaging inside tubular lumen in vivo e.g. for endoscopy, and measuring tumours or polyps of varying morphology. There is a need for a design and simulation tool to accelerate design of new SFDI systems and simulate realistic performance under these scenarios. We present such a system implemented using open-source 3D design and ray-tracing software Blender that simulates media with realistic absorption and scattering in a wide range of geometries. By using Blender’s Cycles ray-tracing engine, our system simulates effects such as varying lighting, refractive index changes, non-normal incidence, specular reflections and shadows, enabling realistic evaluation of new designs. We first demonstrate quantitative agreement between Monte-Carlo simulated absorption and reduced scattering coefficients with those simulated from our Blender system, achieving 16% discrepancy in absorption coefficient and 18% in reduced scattering coefficient. However, we then show that using an empirically derived look-up table the errors reduce to 1% and 0.7% respectively. Next, we simulate SFDI mapping of absorption, scattering and shape for simulated tumour spheroids, demonstrating enhanced contrast. Finally we demonstrate SFDI mapping inside a tubular lumen, which highlighted a important design insight: custom look-up tables must be generated for different longitudinal sections of the lumen. With this approach we achieved 2% absorption error and 2% scattering error. We anticipate our simulation system will aid in the design of novel SFDI systems for key biomedical applications.
- 4 May 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (6) , 2523-2538
Designing and simulating realistic spatial frequency domain imaging systems using open-source 3D rendering software
Spatial frequency domain imaging (SFDI) is a low-cost imaging technique that maps absorption and reduced scattering coefficients, offering improved contrast for important tissue structures such as tumours. Practical SFDI systems must cope with various imaging geometries including imaging planar samples ex vivo, imaging inside tubular lumen in vivo e.g. for endoscopy, and measuring tumours or polyps of varying morphology. There is a need for a design and simulation tool to accelerate design of new SFDI systems and simulate realistic performance under these scenarios. We present such a system implemented using open-source 3D design and ray-tracing software Blender that simulates media with realistic absorption and scattering in a wide range of geometries. By using Blender’s Cycles ray-tracing engine, our system simulates effects such as varying lighting, refractive index changes, non-normal incidence, specular reflections and shadows, enabling realistic evaluation of new designs. We first demonstrate quantitative agreement between Monte-Carlo simulated absorption and reduced scattering coefficients with those simulated from our Blender system, achieving 16% discrepancy in absorption coefficient and 18% in reduced scattering coefficient. However, we then show that using an empirically derived look-up table the errors reduce to 1% and 0.7% respectively. Next, we simulate SFDI mapping of absorption, scattering and shape for simulated tumour spheroids, demonstrating enhanced contrast. Finally we demonstrate SFDI mapping inside a tubular lumen, which highlighted a important design insight: custom look-up tables must be generated for different longitudinal sections of the lumen. With this approach we achieved 2% absorption error and 2% scattering error. We anticipate our simulation system will aid in the design of novel SFDI systems for key biomedical applications.
- Open Access
Designing and simulating realistic spatial frequency domain imaging systems using open-source 3D rendering software
Spatial frequency domain imaging (SFDI) is a low-cost imaging technique that can deliver real-time maps of absorption and reduced scattering coefficients. However, there are a wide range of imaging geometries that practical SFDI systems must cope with including imaging flat samples ex vivo, imaging inside tubular lumen in vivo such as in an endoscopy, and measuring tumours or polyps of varying shapes, sizes and optical properties. There is a need for a design and simulation tool to accelerate design and fabrication of new SFDI systems. We present such a system implemented using open-source 3D design and ray-tracing software Blender that is capable of simulating media with realistic optical properties (mimicking healthy and cancerous tissue), a wide variety of shapes and size, and in both planar and tubular imaging geometries. We first demonstrate quantitative agreement between Monte-Carlo simulated scattering and absorption coefficients and those measured from our Blender system. Next, we show the ability of the system to simulate absorption, scattering and shape for flat samples with small simulated tumours and show that the improved contrast associated with SFDI is reproduced. Finally, to demonstrate the versatility of the system as a design tool we show that it can be used to generate a custom look-up-table for mapping from modulation amplitude values to absorption and scattering values in a tubular geometry, simulating a lumen. As a demonstrative example we show that longitudinal sectioning of the tube, with separate look-up tables for each section, significantly improves accuracy of SFDI, representing an important design insight for future systems. We therefore anticipate our simulation system will significantly aid in the design and development of novel SFDI systems, especially as such systems are miniaturised for deployment in endoscopic and laparoscopic systems.
Open AccessDesigning and simulating realistic spatial frequency domain imaging systems using open-source 3D rendering software
Spatial frequency domain imaging (SFDI) is a low-cost imaging technique that can deliver real-time maps of absorption and reduced scattering coefficients. However, there are a wide range of imaging geometries that practical SFDI systems must cope with including imaging flat samples ex vivo, imaging inside tubular lumen in vivo such as in an endoscopy, and measuring tumours or polyps of varying shapes, sizes and optical properties. There is a need for a design and simulation tool to accelerate design and fabrication of new SFDI systems. We present such a system implemented using open-source 3D design and ray-tracing software Blender that is capable of simulating media with realistic optical properties (mimicking healthy and cancerous tissue), a wide variety of shapes and size, and in both planar and tubular imaging geometries. We first demonstrate quantitative agreement between Monte-Carlo simulated scattering and absorption coefficients and those measured from our Blender system. Next, we show the ability of the system to simulate absorption, scattering and shape for flat samples with small simulated tumours and show that the improved contrast associated with SFDI is reproduced. Finally, to demonstrate the versatility of the system as a design tool we show that it can be used to generate a custom look-up-table for mapping from modulation amplitude values to absorption and scattering values in a tubular geometry, simulating a lumen. As a demonstrative example we show that longitudinal sectioning of the tube, with separate look-up tables for each section, significantly improves accuracy of SFDI, representing an important design insight for future systems. We therefore anticipate our simulation system will significantly aid in the design and development of novel SFDI systems, especially as such systems are miniaturised for deployment in endoscopic and laparoscopic systems.
- Open Access
Modified bronchoscopy masks mitigate aerosols during gastroscopies
Digestive endoscopy has been proven to produce aerosols (1–3). This represents a risk of infection by COVID-19 and other airborne viruses. A number of protective barriers have been proposed to minimise that risk. Continuous suction of the oral cavity (1), shielding barriers (4,5), masks (6,7), and increasing the distance between patient and endoscopist (8) have been proposed as methods to reduce the exposure of endoscopists and endoscopy staff to aerosols. Here, we present a study that uses modified bronchoscopy masks (Explorer endoscopy facemask, Intersurgical Ltd., United Kingdom) to attenuate aerosol production at the patient’s mouth (bare mask shown in Fig. 1a and in use during an upper GI endoscopy in Fig. 1b). We find that this approach offers 47% (p=0.01) reduction in particle count for particles <5μm in diameter (i.e. aerosols), which are known to spread SARS-CoV-2.
Open AccessModified bronchoscopy masks mitigate aerosols during gastroscopies
Digestive endoscopy has been proven to produce aerosols (1–3). This represents a risk of infection by COVID-19 and other airborne viruses. A number of protective barriers have been proposed to minimise that risk. Continuous suction of the oral cavity (1), shielding barriers (4,5), masks (6,7), and increasing the distance between patient and endoscopist (8) have been proposed as methods to reduce the exposure of endoscopists and endoscopy staff to aerosols. Here, we present a study that uses modified bronchoscopy masks (Explorer endoscopy facemask, Intersurgical Ltd., United Kingdom) to attenuate aerosol production at the patient’s mouth (bare mask shown in Fig. 1a and in use during an upper GI endoscopy in Fig. 1b). We find that this approach offers 47% (p=0.01) reduction in particle count for particles <5μm in diameter (i.e. aerosols), which are known to spread SARS-CoV-2.
- Open Access
Training Generative Adversarial Networks for Optical Property Mapping using Synthetic Image Data
We demonstrate training of a Generative Adversarial Network (GAN) for prediction of optical property maps (scattering and absorption) using spatial frequency domain imaging (SFDI) image data sets generated synthetically with free open-source 3D modelling and rendering software, Blender. The flexibility of Blender is exploited to simulate 3 models with real-life relevance to clinical SFDI of diseased tissue: flat samples, flat samples with spheroidal tumours and cylindrical samples with spheroidal tumours representing imaging inside a tubular organ e.g. the gastro-intestinal tract. In all 3 scenarios we show the GAN provides accurate reconstruction of optical properties from single SFDI images with mean normalised error ranging from 1-1.2% for absorption and 0.7-1.2% for scattering, resulting in visually improved contrast for tumour spheroid structures. This compares favourably with 25% absorption error and 10% scattering error achieved using GANs on experimental SFDI data. However, some of this improvement is due to lower noise and availability of perfect ground truths so we therefore cross-validate our synthetically-trained GAN with a GAN trained on experimental data and observe visually accurate results with error of <40% for absorption and <25% for scattering, due largely to the presence of spatial frequency mismatch artefacts. Our synthetically trained GAN is therefore highly relevant to real experimental samples, but provides significant added benefits of large training datasets, perfect ground-truths and the ability to test realistic imaging geometries, e.g. inside cylinders, for which no conventional single-shot demodulation algorithms exist. In future we expect that application of techniques such as domain adaptation or training on hybrid real-synthetic datasets will create a powerful tool for fast, accurate production of optical property maps from real clinical imaging systems.
Open AccessTraining Generative Adversarial Networks for Optical Property Mapping using Synthetic Image Data
We demonstrate training of a Generative Adversarial Network (GAN) for prediction of optical property maps (scattering and absorption) using spatial frequency domain imaging (SFDI) image data sets generated synthetically with free open-source 3D modelling and rendering software, Blender. The flexibility of Blender is exploited to simulate 3 models with real-life relevance to clinical SFDI of diseased tissue: flat samples, flat samples with spheroidal tumours and cylindrical samples with spheroidal tumours representing imaging inside a tubular organ e.g. the gastro-intestinal tract. In all 3 scenarios we show the GAN provides accurate reconstruction of optical properties from single SFDI images with mean normalised error ranging from 1-1.2% for absorption and 0.7-1.2% for scattering, resulting in visually improved contrast for tumour spheroid structures. This compares favourably with 25% absorption error and 10% scattering error achieved using GANs on experimental SFDI data. However, some of this improvement is due to lower noise and availability of perfect ground truths so we therefore cross-validate our synthetically-trained GAN with a GAN trained on experimental data and observe visually accurate results with error of <40% for absorption and <25% for scattering, due largely to the presence of spatial frequency mismatch artefacts. Our synthetically trained GAN is therefore highly relevant to real experimental samples, but provides significant added benefits of large training datasets, perfect ground-truths and the ability to test realistic imaging geometries, e.g. inside cylinders, for which no conventional single-shot demodulation algorithms exist. In future we expect that application of techniques such as domain adaptation or training on hybrid real-synthetic datasets will create a powerful tool for fast, accurate production of optical property maps from real clinical imaging systems.
- Open Access
- 8 September 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (10) , 5171-5186
Training generative adversarial networks for optical property mapping using synthetic image data
We demonstrate the training of a generative adversarial network (GAN) for the prediction of optical property maps (scattering and absorption) using spatial frequency domain imaging (SFDI) image data sets that are generated synthetically with a free open-source 3D modelling and rendering software, Blender. The flexibility of Blender is exploited to simulate 5 models with real-life relevance to clinical SFDI of diseased tissue: flat samples containing a single material, flat samples containing 2 materials, flat samples containing 3 materials, flat samples with spheroidal tumours and cylindrical samples with spheroidal tumours. The last case is particularly relevant as it represents wide-field imaging inside a tubular organ e.g. the gastro-intestinal tract. In all 5 scenarios we show the GAN provides an accurate reconstruction of the optical properties from single SFDI images with a mean normalised error ranging from 1.0-1.2% for absorption and 1.1%-1.2% for scattering, resulting in visually improved contrast for tumour spheroid structures. This compares favourably with the ∼10% absorption error and ∼10% scattering error achieved using GANs on experimental SFDI data. Next, we perform a bi-directional cross-validation of our synthetically-trained GAN, retrained with 90% synthetic and 10% experimental data to encourage domain transfer, with a GAN trained fully on experimental data and observe visually accurate results with an error of 6.3%-10.3% for absorption and 6.6%-11.9% for scattering. Our synthetically trained GAN is therefore highly relevant to real experimental samples but provides the significant added benefits of large training datasets, perfect ground-truths and the ability to test realistic imaging geometries, e.g. inside cylinders, for which no conventional single-shot demodulation algorithms exist. In the future, we expect that the application of techniques such as domain adaptation or training on hybrid real-synthetic datasets will create a powerful tool for fast, accurate production of optical property maps for real clinical imaging systems.
- 8 September 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (10) , 5171-5186
Open AccessTraining generative adversarial networks for optical property mapping using synthetic image data
We demonstrate the training of a generative adversarial network (GAN) for the prediction of optical property maps (scattering and absorption) using spatial frequency domain imaging (SFDI) image data sets that are generated synthetically with a free open-source 3D modelling and rendering software, Blender. The flexibility of Blender is exploited to simulate 5 models with real-life relevance to clinical SFDI of diseased tissue: flat samples containing a single material, flat samples containing 2 materials, flat samples containing 3 materials, flat samples with spheroidal tumours and cylindrical samples with spheroidal tumours. The last case is particularly relevant as it represents wide-field imaging inside a tubular organ e.g. the gastro-intestinal tract. In all 5 scenarios we show the GAN provides an accurate reconstruction of the optical properties from single SFDI images with a mean normalised error ranging from 1.0-1.2% for absorption and 1.1%-1.2% for scattering, resulting in visually improved contrast for tumour spheroid structures. This compares favourably with the ∼10% absorption error and ∼10% scattering error achieved using GANs on experimental SFDI data. Next, we perform a bi-directional cross-validation of our synthetically-trained GAN, retrained with 90% synthetic and 10% experimental data to encourage domain transfer, with a GAN trained fully on experimental data and observe visually accurate results with an error of 6.3%-10.3% for absorption and 6.6%-11.9% for scattering. Our synthetically trained GAN is therefore highly relevant to real experimental samples but provides the significant added benefits of large training datasets, perfect ground-truths and the ability to test realistic imaging geometries, e.g. inside cylinders, for which no conventional single-shot demodulation algorithms exist. In the future, we expect that the application of techniques such as domain adaptation or training on hybrid real-synthetic datasets will create a powerful tool for fast, accurate production of optical property maps for real clinical imaging systems.
- Open Access
Air filtration mitigates aerosol levels both during and after OGD procedures
Objectives Upper GI endoscopies are aerosol generating procedures (AGPs), increasing risk of spreading airborne pathogens. We aim to quantify mitigation of airborne particles via improved ventilation, specifically laminar flow theatres and portable HEPA filters, during and after upper GI endoscopies. Methods This observational study included patients undergoing routine oral gastroscopy in a standard endoscopy room with 15-17 air changes per hour, a standard endoscopy room with portable HEPA filtration unit, and a laminar flow theatre with 300 air changes per hour. A particle counter (diameter range 0.3μm-25μm) took measurements 10cm from the mouth. Three analyses were performed: whole procedure particle counts, event-based counts and air clearance estimation using post-procedure counts. Results Compared to a standard endoscopy room, for whole procedures we observe a 28.5x reduction in particle counts in laminar flow (p5μm for oral extubation (12.2x,pConclusions Laminar flow theatres are highly effective at dispersing aerosols immediately after production and should be considered for high-risk cases where patients are actively infectious or supply of PPE is limited. Portable HEPA filers can safely reduce fallow time between procedures by 40%.
Open AccessAir filtration mitigates aerosol levels both during and after OGD procedures
Objectives Upper GI endoscopies are aerosol generating procedures (AGPs), increasing risk of spreading airborne pathogens. We aim to quantify mitigation of airborne particles via improved ventilation, specifically laminar flow theatres and portable HEPA filters, during and after upper GI endoscopies. Methods This observational study included patients undergoing routine oral gastroscopy in a standard endoscopy room with 15-17 air changes per hour, a standard endoscopy room with portable HEPA filtration unit, and a laminar flow theatre with 300 air changes per hour. A particle counter (diameter range 0.3μm-25μm) took measurements 10cm from the mouth. Three analyses were performed: whole procedure particle counts, event-based counts and air clearance estimation using post-procedure counts. Results Compared to a standard endoscopy room, for whole procedures we observe a 28.5x reduction in particle counts in laminar flow (p5μm for oral extubation (12.2x,pConclusions Laminar flow theatres are highly effective at dispersing aerosols immediately after production and should be considered for high-risk cases where patients are actively infectious or supply of PPE is limited. Portable HEPA filers can safely reduce fallow time between procedures by 40%.