Abstract
Objectives Upper GI endoscopies are aerosol generating procedures (AGPs), increasing risk of spreading airborne pathogens. We aim to quantify mitigation of airborne particles via improved ventilation, specifically laminar flow theatres and portable HEPA filters, during and after upper GI endoscopies. Methods This observational study included patients undergoing routine oral gastroscopy in a standard endoscopy room with 15-17 air changes per hour, a standard endoscopy room with portable HEPA filtration unit, and a laminar flow theatre with 300 air changes per hour. A particle counter (diameter range 0.3μm-25μm) took measurements 10cm from the mouth. Three analyses were performed: whole procedure particle counts, event-based counts and air clearance estimation using post-procedure counts. Results Compared to a standard endoscopy room, for whole procedures we observe a 28.5x reduction in particle counts in laminar flow (p5μm for oral extubation (12.2x,pConclusions Laminar flow theatres are highly effective at dispersing aerosols immediately after production and should be considered for high-risk cases where patients are actively infectious or supply of PPE is limited. Portable HEPA filers can safely reduce fallow time between procedures by 40%.