Tuukka Panula
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tuukka Panula has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Matti Kaisti
University of Turku
12 shared publications - Jukka-Pekka Sirkiä
Department of Computing, University of Turku, Turku, Finland
8 shared publications Ilkka Kantola
Division of Turku University Hospital, Kiinamyllynkatu 4-8, 20521 Turku, Finland
3 shared publicationsMikko Pänkäälä
Department of Computing, University of Turku, Vesilinnantie 5, 20500 Turku, Finland
3 shared publications- Stephan Sigg
Aalto University, Espoo, Finland
3 shared publications Tero Koivisto
Department of Computing, University of Turku, Vesilinnantie 5, 20500 Turku, Finland
3 shared publications
Latest Publications
- Open Access
- 22 April 2026
- Published by Wiley in Advanced Science
- Vol. 13 (34) , e75119
Flexible IMU Sensor Array For 3D Colonoscope Shape Reconstruction and AI‐Based Loop Detection
Looping during colonoscopy procedures is a major cause of patient discomfort and increases the risk of complications. With the rising incidence of colorectal cancer, there is an urgent need for safer and more efficient colonoscopy techniques. We developed a proof‐of‐concept platform for 3D visualization of the colonoscope combined with artificial intelligence (AI)‐based loop detection. The system consists of an array of 15 inertial measurement units (IMUs) mounted on a flexible printed circuit board that can be retrofitted into the instrument channel of conventional colonoscopes. Using sensor fusion algorithms, the position and orientation of individual IMUs are estimated to reconstruct the 3D shape of the colonoscope in real time. The system successfully reconstructed the colonoscope shape in a silicone colon phantom, and the AI model achieved high loop‐detection performance with an area under the receiver operating characteristic curve of 0.95 on test data. These results demonstrate feasibility in an artificial environment, while further validation in clinical settings is required.
- 22 April 2026
- Published by Wiley in Advanced Science
- Vol. 13 (34) , e75119
Open AccessFlexible IMU Sensor Array For 3D Colonoscope Shape Reconstruction and AI‐Based Loop Detection
Looping during colonoscopy procedures is a major cause of patient discomfort and increases the risk of complications. With the rising incidence of colorectal cancer, there is an urgent need for safer and more efficient colonoscopy techniques. We developed a proof‐of‐concept platform for 3D visualization of the colonoscope combined with artificial intelligence (AI)‐based loop detection. The system consists of an array of 15 inertial measurement units (IMUs) mounted on a flexible printed circuit board that can be retrofitted into the instrument channel of conventional colonoscopes. Using sensor fusion algorithms, the position and orientation of individual IMUs are estimated to reconstruct the 3D shape of the colonoscope in real time. The system successfully reconstructed the colonoscope shape in a silicone colon phantom, and the AI model achieved high loop‐detection performance with an area under the receiver operating characteristic curve of 0.95 on test data. These results demonstrate feasibility in an artificial environment, while further validation in clinical settings is required.
- Open Access
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. PP (19373333) , 1-17
Optical Techniques to Assess Cutaneous Microvascular Function in Cardiovascular Disease
Microcirculation is essential for maintaining tissue health and overall physiological function. Over the past few decades, various optical techniques have been developed to measure, visualize, and assess microvasculature. The skin has easily an accessible vascular bed allowing for noninvasive evaluation of microvascular function. Alterations in cutaneous microcirculation have been linked to dysfunctions in other target organs and vascular regions reinforcing the idea that cutaneous microcirculation can provide insights into systemic vascular conditions. Currently, there is no unified review focusing specifically on microcirculation-related optical techniques nor comprehensive analyses connecting these technological innovations to clinical evidence. This review aims to bridge that gap by systematically examining the wide spectrum of optical technologies used in assessing cutaneous microvascular function. We review techniques based on non-coherent light including oximetry, photoplethysmography, and microscopic methods and coherent light-based techniques, including speckle contrast imaging, diffuse correlation spectroscopy, photoacousting imaging, laser Doppler flowmetry and self-mixing interferometry. We emphasize cardiovascular research and evaluate the clinical relevance and technical maturity of the techniques. Additionally, brief explanation of skin structure and skin microvasculature while explaining light skin interaction is discussed. Lastly, we discuss these findings on wider context by including discussions and advancements in multimodal monitoring and machine learning.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. PP (19373333) , 1-17
Open AccessOptical Techniques to Assess Cutaneous Microvascular Function in Cardiovascular Disease
Microcirculation is essential for maintaining tissue health and overall physiological function. Over the past few decades, various optical techniques have been developed to measure, visualize, and assess microvasculature. The skin has easily an accessible vascular bed allowing for noninvasive evaluation of microvascular function. Alterations in cutaneous microcirculation have been linked to dysfunctions in other target organs and vascular regions reinforcing the idea that cutaneous microcirculation can provide insights into systemic vascular conditions. Currently, there is no unified review focusing specifically on microcirculation-related optical techniques nor comprehensive analyses connecting these technological innovations to clinical evidence. This review aims to bridge that gap by systematically examining the wide spectrum of optical technologies used in assessing cutaneous microvascular function. We review techniques based on non-coherent light including oximetry, photoplethysmography, and microscopic methods and coherent light-based techniques, including speckle contrast imaging, diffuse correlation spectroscopy, photoacousting imaging, laser Doppler flowmetry and self-mixing interferometry. We emphasize cardiovascular research and evaluate the clinical relevance and technical maturity of the techniques. Additionally, brief explanation of skin structure and skin microvasculature while explaining light skin interaction is discussed. Lastly, we discuss these findings on wider context by including discussions and advancements in multimodal monitoring and machine learning.
- Open Access
- 4 November 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 294, 118163
Feasibility of continuous microvascular tissue oxygenation monitoring using discrete optical semiconductor devices
- 4 November 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 294, 118163
Open AccessFeasibility of continuous microvascular tissue oxygenation monitoring using discrete optical semiconductor devices
- Open Access
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 300-304
Tracking Radial Artery Dynamics Using Brightness-Mode Ultrasound and Video Analysis
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 300-304
Open AccessTracking Radial Artery Dynamics Using Brightness-Mode Ultrasound and Video Analysis
- Open Access
- 7 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 184-190
Wearable Non-Invasive Arterial Pulse Detection with a Millimeter-wave Radar
- 7 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 184-190
Open AccessWearable Non-Invasive Arterial Pulse Detection with a Millimeter-wave Radar
- Open Access
- 25 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (8) , 1-4
Wearable Ring-Based System for Measuring Hemodynamic Parameters
Currently, there are no reliable and convenient wearable solutions for measuring blood pressure, which remains a key indicator of cardiovascular health. Many existing measuring systems are bulky, complex, and expensive, which limits their practicality for everyday use for wearable application. We introduce a compact, ring-shaped blood pressure measurement device as a proof-of-concept. It is based on a local oscillometric spot measurement obtained from the base of the index finger. The ring is made of two parts, where the outer sleeve induces pressure to the finger, and the inner guide bushing houses a ring sensor unit, which incorporates a commercial photoplethysmography module and a force-sensitive resistor. Manual rotation of the outer part of the ring applies pressure that occludes the digital artery, allowing estimation of blood pressure. For evaluation, we compared the results from our device with reference measurements from a brachial cuff blood pressure monitor. Ten volunteers underwent three to six measurements. The ring was able to capture moderate-quality oscillometric responses. The results (Bland–Altman: systolic mean difference $\upmu$ = 1.1 mmHg and standard deviation $\sigma$ = 9.5 mmHg, diastolic $\upmu$ = 0.1 mmHg and $\sigma$ = 13.4 mmHg) demonstrate the feasibility of the approach. There are still many sources of uncertainty, but these results highlight the potential of this new setup. As a proof-of-concept, the current setup lays the groundwork for future improvements. With further mechanical refinements and system simplifications, this wearable ring offers a promising pathway to accessible, comfortable, and portable blood pressure monitoring.
- 25 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (8) , 1-4
Open AccessWearable Ring-Based System for Measuring Hemodynamic Parameters
Currently, there are no reliable and convenient wearable solutions for measuring blood pressure, which remains a key indicator of cardiovascular health. Many existing measuring systems are bulky, complex, and expensive, which limits their practicality for everyday use for wearable application. We introduce a compact, ring-shaped blood pressure measurement device as a proof-of-concept. It is based on a local oscillometric spot measurement obtained from the base of the index finger. The ring is made of two parts, where the outer sleeve induces pressure to the finger, and the inner guide bushing houses a ring sensor unit, which incorporates a commercial photoplethysmography module and a force-sensitive resistor. Manual rotation of the outer part of the ring applies pressure that occludes the digital artery, allowing estimation of blood pressure. For evaluation, we compared the results from our device with reference measurements from a brachial cuff blood pressure monitor. Ten volunteers underwent three to six measurements. The ring was able to capture moderate-quality oscillometric responses. The results (Bland–Altman: systolic mean difference $\upmu$ = 1.1 mmHg and standard deviation $\sigma$ = 9.5 mmHg, diastolic $\upmu$ = 0.1 mmHg and $\sigma$ = 13.4 mmHg) demonstrate the feasibility of the approach. There are still many sources of uncertainty, but these results highlight the potential of this new setup. As a proof-of-concept, the current setup lays the groundwork for future improvements. With further mechanical refinements and system simplifications, this wearable ring offers a promising pathway to accessible, comfortable, and portable blood pressure monitoring.
- Open Access
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (3) , 975-984
Multi-Sensory System for Spatially Aware Colonoscopy
The traditional method of performing a colonoscopy requires a trained physician operating the instrument manually. There is no proper feedback to aid the user in the process and typically the physician has to rely solely on the camera output to guide the endoscope. This method can lead to discomfort or even colon perforation due to the elongated endoscope scratching or tearing the colon tissue. To address this issue and enable spatial awareness to the instrument, we propose a modular multi-sensor system that integrates bending, pressure, and motion sensing units into the endoscope. All sensors are manufactured using inexpensive off-the-shelf components. The proposed sensor system was characterized on a robotic test bench and validated in a colon phantom study. The results demonstrate the feasibility and robustness of the proposed sensor fusion approach in colonoscopy which has the potential for safer and more effective inspection of the bowels. The introduction of these sensing modalities to an endoscope paves the way for AI-assisted and possibly autonomous colonoscopy in the future.
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (3) , 975-984
Open AccessMulti-Sensory System for Spatially Aware Colonoscopy
The traditional method of performing a colonoscopy requires a trained physician operating the instrument manually. There is no proper feedback to aid the user in the process and typically the physician has to rely solely on the camera output to guide the endoscope. This method can lead to discomfort or even colon perforation due to the elongated endoscope scratching or tearing the colon tissue. To address this issue and enable spatial awareness to the instrument, we propose a modular multi-sensor system that integrates bending, pressure, and motion sensing units into the endoscope. All sensors are manufactured using inexpensive off-the-shelf components. The proposed sensor system was characterized on a robotic test bench and validated in a colon phantom study. The results demonstrate the feasibility and robustness of the proposed sensor fusion approach in colonoscopy which has the potential for safer and more effective inspection of the bowels. The introduction of these sensing modalities to an endoscope paves the way for AI-assisted and possibly autonomous colonoscopy in the future.
- Open Access
Non-Invasive Arterial Pulse Detection with Millimeter-wave Radar and Comparison With Photoplethysmography
Cardiovascular diseases remain a leading cause of mortality and disability. The convenient measurement of cardiovascular health using smart systems is therefore a key enabler to foster accurate and early detection and diagnosis of cardiovascular diseases and it require accessing a correct pulse morphology similar to arterial pressure wave. This paper investigates the comparison between different sensor modalities, such as mmWave and photoplethysmography from the same physiological site and reference continuous non-invasive blood pressure devide. We have developed a hardware prototype and established an experiment consist of 23 test participants. Both mmWave and PPG are capable of detecting inter-beat intervals. mmWave is providing more accurate arterial pulse waveform than green photoplethysmography.
Open AccessNon-Invasive Arterial Pulse Detection with Millimeter-wave Radar and Comparison With Photoplethysmography
Cardiovascular diseases remain a leading cause of mortality and disability. The convenient measurement of cardiovascular health using smart systems is therefore a key enabler to foster accurate and early detection and diagnosis of cardiovascular diseases and it require accessing a correct pulse morphology similar to arterial pressure wave. This paper investigates the comparison between different sensor modalities, such as mmWave and photoplethysmography from the same physiological site and reference continuous non-invasive blood pressure devide. We have developed a hardware prototype and established an experiment consist of 23 test participants. Both mmWave and PPG are capable of detecting inter-beat intervals. mmWave is providing more accurate arterial pulse waveform than green photoplethysmography.
- Open Access
- 22 April 2024
- Published by Wiley in Advanced Science
- Vol. 11 (24) , e2310022
Non‐Invasive Hemodynamic Monitoring System Integrating Spectrometry, Photoplethysmography, and Arterial Pressure Measurement Capabilities
Minimally invasive and non‐invasive hemodynamic monitoring technologies have recently gained more attention, driven by technological advances and the inherent risk of complications in invasive techniques. In this article, an experimental non‐invasive system is presented that effectively combines the capabilities of spectrometry, photoplethysmography (PPG), and arterial pressure measurement. Both time‐ and wavelength‐resolved optical signals from the fingertip are measured under external pressure, which gradually increased above the level of systolic blood pressure. The optical channels measured at 434–731 nm divided into three groups separated by a group of channels with wavelengths approximately between 590 and 630 nm. This group of channels, labeled transition band, is characterized by abrupt changes resulting from a decrease in the absorption coefficient of whole blood. External pressure levels of maximum pulsation showed that shorter wavelengths (630 nm) probe high‐pressure arteries. The results on perfusion indices and DC component level changes showed clear differences between the optical channels, further highlighting the importance of wavelength selection in optical hemodynamic monitoring systems. Altogether, the results demonstrated that the integrated system presented has the potential to extract new hemodynamic information simultaneously from macrocirculation to microcirculation.
- 22 April 2024
- Published by Wiley in Advanced Science
- Vol. 11 (24) , e2310022
Open AccessNon‐Invasive Hemodynamic Monitoring System Integrating Spectrometry, Photoplethysmography, and Arterial Pressure Measurement Capabilities
Minimally invasive and non‐invasive hemodynamic monitoring technologies have recently gained more attention, driven by technological advances and the inherent risk of complications in invasive techniques. In this article, an experimental non‐invasive system is presented that effectively combines the capabilities of spectrometry, photoplethysmography (PPG), and arterial pressure measurement. Both time‐ and wavelength‐resolved optical signals from the fingertip are measured under external pressure, which gradually increased above the level of systolic blood pressure. The optical channels measured at 434–731 nm divided into three groups separated by a group of channels with wavelengths approximately between 590 and 630 nm. This group of channels, labeled transition band, is characterized by abrupt changes resulting from a decrease in the absorption coefficient of whole blood. External pressure levels of maximum pulsation showed that shorter wavelengths (630 nm) probe high‐pressure arteries. The results on perfusion indices and DC component level changes showed clear differences between the optical channels, further highlighting the importance of wavelength selection in optical hemodynamic monitoring systems. Altogether, the results demonstrated that the integrated system presented has the potential to extract new hemodynamic information simultaneously from macrocirculation to microcirculation.
- Open Access
Development and clinical validation of a miniaturized finger probe for bedside hemodynamic monitoring