Jukka-Pekka Sirkiä
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jukka-Pekka Sirkiä has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Matti Kaisti
University of Turku
9 shared publications - Tuukka Panula
Department of Computing, University of Turku, Turku, Finland
8 shared publications - Katri Karhinoja
University of Turku
3 shared publications Matti Kaisti
2 shared publications- Antti Airola
University of Turku
1 shared publication Antti Vasankari
1 shared publication
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (12) , 6012904
Enhancing Activity Recognition via Barometric–Inertial Sensor Fusion
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (12) , 6012904
Enhancing Activity Recognition via Barometric–Inertial Sensor Fusion
- Open Access
- 19 September 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 287
Flexible framework for generating synthetic electrocardiograms and photoplethysmograms using a parametrized model
- 19 September 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 287
Open AccessFlexible framework for generating synthetic electrocardiograms and photoplethysmograms using a parametrized model
- Open Access
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. PP (19373333) , 1-17
Optical Techniques to Assess Cutaneous Microvascular Function in Cardiovascular Disease
Microcirculation is essential for maintaining tissue health and overall physiological function. Over the past few decades, various optical techniques have been developed to measure, visualize, and assess microvasculature. The skin has easily an accessible vascular bed allowing for noninvasive evaluation of microvascular function. Alterations in cutaneous microcirculation have been linked to dysfunctions in other target organs and vascular regions reinforcing the idea that cutaneous microcirculation can provide insights into systemic vascular conditions. Currently, there is no unified review focusing specifically on microcirculation-related optical techniques nor comprehensive analyses connecting these technological innovations to clinical evidence. This review aims to bridge that gap by systematically examining the wide spectrum of optical technologies used in assessing cutaneous microvascular function. We review techniques based on non-coherent light including oximetry, photoplethysmography, and microscopic methods and coherent light-based techniques, including speckle contrast imaging, diffuse correlation spectroscopy, photoacousting imaging, laser Doppler flowmetry and self-mixing interferometry. We emphasize cardiovascular research and evaluate the clinical relevance and technical maturity of the techniques. Additionally, brief explanation of skin structure and skin microvasculature while explaining light skin interaction is discussed. Lastly, we discuss these findings on wider context by including discussions and advancements in multimodal monitoring and machine learning.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. PP (19373333) , 1-17
Open AccessOptical Techniques to Assess Cutaneous Microvascular Function in Cardiovascular Disease
Microcirculation is essential for maintaining tissue health and overall physiological function. Over the past few decades, various optical techniques have been developed to measure, visualize, and assess microvasculature. The skin has easily an accessible vascular bed allowing for noninvasive evaluation of microvascular function. Alterations in cutaneous microcirculation have been linked to dysfunctions in other target organs and vascular regions reinforcing the idea that cutaneous microcirculation can provide insights into systemic vascular conditions. Currently, there is no unified review focusing specifically on microcirculation-related optical techniques nor comprehensive analyses connecting these technological innovations to clinical evidence. This review aims to bridge that gap by systematically examining the wide spectrum of optical technologies used in assessing cutaneous microvascular function. We review techniques based on non-coherent light including oximetry, photoplethysmography, and microscopic methods and coherent light-based techniques, including speckle contrast imaging, diffuse correlation spectroscopy, photoacousting imaging, laser Doppler flowmetry and self-mixing interferometry. We emphasize cardiovascular research and evaluate the clinical relevance and technical maturity of the techniques. Additionally, brief explanation of skin structure and skin microvasculature while explaining light skin interaction is discussed. Lastly, we discuss these findings on wider context by including discussions and advancements in multimodal monitoring and machine learning.
- Open Access
- 25 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (8) , 1-4
Wearable Ring-Based System for Measuring Hemodynamic Parameters
Currently, there are no reliable and convenient wearable solutions for measuring blood pressure, which remains a key indicator of cardiovascular health. Many existing measuring systems are bulky, complex, and expensive, which limits their practicality for everyday use for wearable application. We introduce a compact, ring-shaped blood pressure measurement device as a proof-of-concept. It is based on a local oscillometric spot measurement obtained from the base of the index finger. The ring is made of two parts, where the outer sleeve induces pressure to the finger, and the inner guide bushing houses a ring sensor unit, which incorporates a commercial photoplethysmography module and a force-sensitive resistor. Manual rotation of the outer part of the ring applies pressure that occludes the digital artery, allowing estimation of blood pressure. For evaluation, we compared the results from our device with reference measurements from a brachial cuff blood pressure monitor. Ten volunteers underwent three to six measurements. The ring was able to capture moderate-quality oscillometric responses. The results (Bland–Altman: systolic mean difference $\upmu$ = 1.1 mmHg and standard deviation $\sigma$ = 9.5 mmHg, diastolic $\upmu$ = 0.1 mmHg and $\sigma$ = 13.4 mmHg) demonstrate the feasibility of the approach. There are still many sources of uncertainty, but these results highlight the potential of this new setup. As a proof-of-concept, the current setup lays the groundwork for future improvements. With further mechanical refinements and system simplifications, this wearable ring offers a promising pathway to accessible, comfortable, and portable blood pressure monitoring.
- 25 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (8) , 1-4
Open AccessWearable Ring-Based System for Measuring Hemodynamic Parameters
Currently, there are no reliable and convenient wearable solutions for measuring blood pressure, which remains a key indicator of cardiovascular health. Many existing measuring systems are bulky, complex, and expensive, which limits their practicality for everyday use for wearable application. We introduce a compact, ring-shaped blood pressure measurement device as a proof-of-concept. It is based on a local oscillometric spot measurement obtained from the base of the index finger. The ring is made of two parts, where the outer sleeve induces pressure to the finger, and the inner guide bushing houses a ring sensor unit, which incorporates a commercial photoplethysmography module and a force-sensitive resistor. Manual rotation of the outer part of the ring applies pressure that occludes the digital artery, allowing estimation of blood pressure. For evaluation, we compared the results from our device with reference measurements from a brachial cuff blood pressure monitor. Ten volunteers underwent three to six measurements. The ring was able to capture moderate-quality oscillometric responses. The results (Bland–Altman: systolic mean difference $\upmu$ = 1.1 mmHg and standard deviation $\sigma$ = 9.5 mmHg, diastolic $\upmu$ = 0.1 mmHg and $\sigma$ = 13.4 mmHg) demonstrate the feasibility of the approach. There are still many sources of uncertainty, but these results highlight the potential of this new setup. As a proof-of-concept, the current setup lays the groundwork for future improvements. With further mechanical refinements and system simplifications, this wearable ring offers a promising pathway to accessible, comfortable, and portable blood pressure monitoring.
- Open Access
- 22 April 2024
- Published by Wiley in Advanced Science
- Vol. 11 (24) , e2310022
Non‐Invasive Hemodynamic Monitoring System Integrating Spectrometry, Photoplethysmography, and Arterial Pressure Measurement Capabilities
Minimally invasive and non‐invasive hemodynamic monitoring technologies have recently gained more attention, driven by technological advances and the inherent risk of complications in invasive techniques. In this article, an experimental non‐invasive system is presented that effectively combines the capabilities of spectrometry, photoplethysmography (PPG), and arterial pressure measurement. Both time‐ and wavelength‐resolved optical signals from the fingertip are measured under external pressure, which gradually increased above the level of systolic blood pressure. The optical channels measured at 434–731 nm divided into three groups separated by a group of channels with wavelengths approximately between 590 and 630 nm. This group of channels, labeled transition band, is characterized by abrupt changes resulting from a decrease in the absorption coefficient of whole blood. External pressure levels of maximum pulsation showed that shorter wavelengths (630 nm) probe high‐pressure arteries. The results on perfusion indices and DC component level changes showed clear differences between the optical channels, further highlighting the importance of wavelength selection in optical hemodynamic monitoring systems. Altogether, the results demonstrated that the integrated system presented has the potential to extract new hemodynamic information simultaneously from macrocirculation to microcirculation.
- 22 April 2024
- Published by Wiley in Advanced Science
- Vol. 11 (24) , e2310022
Open AccessNon‐Invasive Hemodynamic Monitoring System Integrating Spectrometry, Photoplethysmography, and Arterial Pressure Measurement Capabilities
Minimally invasive and non‐invasive hemodynamic monitoring technologies have recently gained more attention, driven by technological advances and the inherent risk of complications in invasive techniques. In this article, an experimental non‐invasive system is presented that effectively combines the capabilities of spectrometry, photoplethysmography (PPG), and arterial pressure measurement. Both time‐ and wavelength‐resolved optical signals from the fingertip are measured under external pressure, which gradually increased above the level of systolic blood pressure. The optical channels measured at 434–731 nm divided into three groups separated by a group of channels with wavelengths approximately between 590 and 630 nm. This group of channels, labeled transition band, is characterized by abrupt changes resulting from a decrease in the absorption coefficient of whole blood. External pressure levels of maximum pulsation showed that shorter wavelengths (630 nm) probe high‐pressure arteries. The results on perfusion indices and DC component level changes showed clear differences between the optical channels, further highlighting the importance of wavelength selection in optical hemodynamic monitoring systems. Altogether, the results demonstrated that the integrated system presented has the potential to extract new hemodynamic information simultaneously from macrocirculation to microcirculation.
- Open Access
- 15 April 2024
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 7
Investigating the impact of contact pressure on photoplethysmograms
- 15 April 2024
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 7
Open AccessInvestigating the impact of contact pressure on photoplethysmograms
- Open Access
- 22 September 2023
- Published by Elsevier in Expert Systems with Applications
- Vol. 238
Wearable edge machine learning with synthetic photoplethysmograms
- 22 September 2023
- Published by Elsevier in Expert Systems with Applications
- Vol. 238
Open AccessWearable edge machine learning with synthetic photoplethysmograms
- Open Access
- 12 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Tonometric Multi-Wavelength Photoplethysmography for Studying the Cutaneous Microvasculature of the Fingertip
Microcirculation is a key compartment in the human cardiovascular system due to its vital roles in providing oxygen and nutrients to tissue, removing metabolic byproducts and regulating blood flow in organs. This network of small blood vessels, known as microvasculature, has been shown to have a link to many cardiovascular diseases. This work presents a method capable of extracting information from different depths of the cutaneous vasculature, including the microvasculature, of the fingertip using an optical sensor with controllable external compression force. Our experiments show that the optical channels can be used to estimate blood pressure at different depths of the tissue, including shallow depths with microvascular blood vessels. Additionally, we show that shorter-wavelength optical signals (465 nm, 515 nm and 590 nm) are more sensitive to pressure-induced vasodilation than longer-wavelength (640 nm and 880 nm) signals. The results indicate that the method can obtain signals originating from different depths of the cutaneous vasculature, from large arteries deep in the skin to arterioles and capillaries close to the surface of the skin. The experimental results are discussed with the help of a Monte Carlo model that simulates photon propagation in tissue under different compression scenarios.
- 12 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Open AccessTonometric Multi-Wavelength Photoplethysmography for Studying the Cutaneous Microvasculature of the Fingertip
Microcirculation is a key compartment in the human cardiovascular system due to its vital roles in providing oxygen and nutrients to tissue, removing metabolic byproducts and regulating blood flow in organs. This network of small blood vessels, known as microvasculature, has been shown to have a link to many cardiovascular diseases. This work presents a method capable of extracting information from different depths of the cutaneous vasculature, including the microvasculature, of the fingertip using an optical sensor with controllable external compression force. Our experiments show that the optical channels can be used to estimate blood pressure at different depths of the tissue, including shallow depths with microvascular blood vessels. Additionally, we show that shorter-wavelength optical signals (465 nm, 515 nm and 590 nm) are more sensitive to pressure-induced vasodilation than longer-wavelength (640 nm and 880 nm) signals. The results indicate that the method can obtain signals originating from different depths of the cutaneous vasculature, from large arteries deep in the skin to arterioles and capillaries close to the surface of the skin. The experimental results are discussed with the help of a Monte Carlo model that simulates photon propagation in tissue under different compression scenarios.
- Open Access
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Continuous Blood Pressure Monitoring Using Nonpulsatile Photoplethysmographic Components for Low-Frequency Vascular Unloading
Objective : Continuous blood pressure (BP) monitoring gives a better understanding of a person’s cardiovascular health status than single BP measurements. The existing measurement techniques are often highly complex and expensive, or suffer from inaccuracies. We propose a simple yet effective technique for continuous blood pressure monitoring. Methods : Our method is based on the finding that the non-pulsatile (DC) component of the photoplethysmograph (PPG) correlates with blood pressure. By keeping the infrared PPG DC component constant by altering the applied external pressure using a feedback mechanism the BP can be measured continuously. This way the pressure read from the pressure sensor follows the mean intra-arterial BP. We call this low-frequency vascular unloading. We propose a method for assessing the measurement error introduced by changes in vasomotor tone. Green PPG was used for the vasomotor compensation method. We packaged the technology to a wearable finger-worn device similar to a pulse oximeter probe. Results : We measured over 90 minutes of continuous BP data from total of 7 subjects. The subjects were asked to perform different BP altering maneuvers during the measurement. The ability to track BP changes was verified by continuous mean arterial pressure (MAP) readings measured with the reference device (CNSystems CNAP 500) and our device, resulting in correlation of r = 0.894 and (( mean ± SD ) mmHg) of (0.3±4.3) mmHg for mean arterial pressure. Without vasomotor tone compensation the results were with slightly less accurate: r = 0.83, (-1.4±5.1) mmHg. Conclusion : The proposed technology performed well compared to traditional vascular unloading technique while requiring significantly less complex control logic and no fast-switching pneumatics. Significance : The proposed technique is simple, yet effective, low-cost solution and it can be constructed from off-the-shelf components and miniaturized into a wearable form factor. The technique has potential in the field of health wearables and remote continuous BP monitoring for personalized health applications.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Open AccessContinuous Blood Pressure Monitoring Using Nonpulsatile Photoplethysmographic Components for Low-Frequency Vascular Unloading
Objective : Continuous blood pressure (BP) monitoring gives a better understanding of a person’s cardiovascular health status than single BP measurements. The existing measurement techniques are often highly complex and expensive, or suffer from inaccuracies. We propose a simple yet effective technique for continuous blood pressure monitoring. Methods : Our method is based on the finding that the non-pulsatile (DC) component of the photoplethysmograph (PPG) correlates with blood pressure. By keeping the infrared PPG DC component constant by altering the applied external pressure using a feedback mechanism the BP can be measured continuously. This way the pressure read from the pressure sensor follows the mean intra-arterial BP. We call this low-frequency vascular unloading. We propose a method for assessing the measurement error introduced by changes in vasomotor tone. Green PPG was used for the vasomotor compensation method. We packaged the technology to a wearable finger-worn device similar to a pulse oximeter probe. Results : We measured over 90 minutes of continuous BP data from total of 7 subjects. The subjects were asked to perform different BP altering maneuvers during the measurement. The ability to track BP changes was verified by continuous mean arterial pressure (MAP) readings measured with the reference device (CNSystems CNAP 500) and our device, resulting in correlation of r = 0.894 and (( mean ± SD ) mmHg) of (0.3±4.3) mmHg for mean arterial pressure. Without vasomotor tone compensation the results were with slightly less accurate: r = 0.83, (-1.4±5.1) mmHg. Conclusion : The proposed technology performed well compared to traditional vascular unloading technique while requiring significantly less complex control logic and no fast-switching pneumatics. Significance : The proposed technique is simple, yet effective, low-cost solution and it can be constructed from off-the-shelf components and miniaturized into a wearable form factor. The technique has potential in the field of health wearables and remote continuous BP monitoring for personalized health applications.
- Open Access
Development and Clinical Validation of a Miniaturized Finger Probe for Bedside Hemodynamic Monitoring
Background: Hypertension, or elevated blood pressure (BP), is a marker for many cardiovascular diseases and can lead to life-threatening conditions such as heart failure, coronary artery disease, and stroke. BP monitoring using a traditional arm cuff device is often inconvenient and possibly painful in long-term use, i.e. during sleep. Methods: We present a miniature cuffless tonometric finger probe system, that uses the oscillometric method to measure blood pressure (BP). Our approach uses a motorized press that is used to apply pressure to the finger tip to measure BP. Results: We verified the functionality of the device in a clinical trial (n=43) resulting in systolic (SBP) and diastolic (DBP) pressures (( mean ± SD ) mmHg) of (−3.5 ± 8.4) mmHg and (−4.0 ± 4.4) mmHg, respectively. Comparison was made with manual auscultation (n=26) and automated cuff oscillometry (n=18). In addition to BP, we demonstrated the ability of the device to assess arterial stiffness (n=18) and detect atrial fibrillation (n=6). Conclusions: We were able to introduce a sufficiently small device that could be used for convenient ambulatory measurements and worn during sleep with minimal discomfort. Lastly, we evaluate methods to further develop the concept and discuss future directions. Plain language summary: Traditional cuff-based automated BP instruments are mainly suitable for individual measurements and are often inconvenient to use. Patients in a hospital ward are typically monitored with many systems and devices. Our aim is to develop a blood pressure measurement technology that could be integrated into a finger-worn pulse oximeter. This way the need for a bulky and inconvenient arm cuff could be eliminated and the number of needed monitoring devices could be reduced. The proposed technology is especially suitable for pseudo-continuous BP measurement, that is, taking automated measurements periodically, enabling BP trend tracking and analysis. In this study, we clinically validate our technology for blood pressure monitoring and further demonstrate its potential to measure arterial stiffness and detect atrial fibrillation.
Open AccessDevelopment and Clinical Validation of a Miniaturized Finger Probe for Bedside Hemodynamic Monitoring
Background: Hypertension, or elevated blood pressure (BP), is a marker for many cardiovascular diseases and can lead to life-threatening conditions such as heart failure, coronary artery disease, and stroke. BP monitoring using a traditional arm cuff device is often inconvenient and possibly painful in long-term use, i.e. during sleep. Methods: We present a miniature cuffless tonometric finger probe system, that uses the oscillometric method to measure blood pressure (BP). Our approach uses a motorized press that is used to apply pressure to the finger tip to measure BP. Results: We verified the functionality of the device in a clinical trial (n=43) resulting in systolic (SBP) and diastolic (DBP) pressures (( mean ± SD ) mmHg) of (−3.5 ± 8.4) mmHg and (−4.0 ± 4.4) mmHg, respectively. Comparison was made with manual auscultation (n=26) and automated cuff oscillometry (n=18). In addition to BP, we demonstrated the ability of the device to assess arterial stiffness (n=18) and detect atrial fibrillation (n=6). Conclusions: We were able to introduce a sufficiently small device that could be used for convenient ambulatory measurements and worn during sleep with minimal discomfort. Lastly, we evaluate methods to further develop the concept and discuss future directions. Plain language summary: Traditional cuff-based automated BP instruments are mainly suitable for individual measurements and are often inconvenient to use. Patients in a hospital ward are typically monitored with many systems and devices. Our aim is to develop a blood pressure measurement technology that could be integrated into a finger-worn pulse oximeter. This way the need for a bulky and inconvenient arm cuff could be eliminated and the number of needed monitoring devices could be reduced. The proposed technology is especially suitable for pseudo-continuous BP measurement, that is, taking automated measurements periodically, enabling BP trend tracking and analysis. In this study, we clinically validate our technology for blood pressure monitoring and further demonstrate its potential to measure arterial stiffness and detect atrial fibrillation.