Marina N. Lyutikova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marina N. Lyutikova has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Sergey M. Korobeynikov
Power Engineering Faculty, Novosibirsk State Technical University, Novosibirsk, Russia
4 shared publications A. A. Konovalov
Novosibirsk State Technical University, Novosibirsk, Russia
3 shared publicationsS. M. Korobeinikov
Novosibirsk State Technical University, Novosibirsk, Russia
3 shared publications- A. S. Gadzhiyeva
ФГБОУ ВО «Югорский государственный университет
2 shared publications Alexander V. Ridel
Industrial Safety Department, Novosibirsk State Technical University, Novosibirsk, Russia
2 shared publicationsKhanty-Mansiysk State Medical Academy
2 shared publications
Latest Publications
- 1 January 2025
- Published by Kabel, LLC in Electric Power. Transmission and Distribution
- Vol. 2 (89)
Assessment of Compatibility of Transformer Oils When Mixing
This article provides the results of study of the impact of paraffi n-type transformer oil Gazpromneft GK brand 2 properties on the oils of different brands and different oxidation stability category when mixing (high — GK, LUKOIL VG, Nytro 10Х, Nytro 10ХN, Nytro 11GX, Nytro 4000X, TANECO GK; middle — Т-1500 and low — TKp). The listed oils and their mixtures with Gazpromneft GK brand 2 oil were tested for oxidation stability. After enhanced oxidation the acid number and the content of sediments and fugitive low-molecular acids were determined in all samples. Immediately after mixing the transformer oils were tested with regard to tangent of dielectric loss angle at 90°С and interfacial tension. By the results obtained, the authors make the conclusion about possible mixing of Gazpromneft GK brand 2 oil with other oil brands (GK, LUKOIL VG, Nytro 10Х, Nytro 10ХN, Nytro 11GX, Nytro 4000X, TANECO ГК, Т-1500, TKp) without degradation of properties in the proportions under consideration (1:9, 2:8, 3:7, 4:6). Besides the compulsory fi gures, the optical opacity and the oxidation index were measured before and after long-term aging of samples. By assessing the data acquired we may notice the coherence of results of optional testing with those of standard ones.
- 1 January 2025
- Published by Kabel, LLC in Electric Power. Transmission and Distribution
- Vol. 2 (89)
Assessment of Compatibility of Transformer Oils When Mixing
This article provides the results of study of the impact of paraffi n-type transformer oil Gazpromneft GK brand 2 properties on the oils of different brands and different oxidation stability category when mixing (high — GK, LUKOIL VG, Nytro 10Х, Nytro 10ХN, Nytro 11GX, Nytro 4000X, TANECO GK; middle — Т-1500 and low — TKp). The listed oils and their mixtures with Gazpromneft GK brand 2 oil were tested for oxidation stability. After enhanced oxidation the acid number and the content of sediments and fugitive low-molecular acids were determined in all samples. Immediately after mixing the transformer oils were tested with regard to tangent of dielectric loss angle at 90°С and interfacial tension. By the results obtained, the authors make the conclusion about possible mixing of Gazpromneft GK brand 2 oil with other oil brands (GK, LUKOIL VG, Nytro 10Х, Nytro 10ХN, Nytro 11GX, Nytro 4000X, TANECO ГК, Т-1500, TKp) without degradation of properties in the proportions under consideration (1:9, 2:8, 3:7, 4:6). Besides the compulsory fi gures, the optical opacity and the oxidation index were measured before and after long-term aging of samples. By assessing the data acquired we may notice the coherence of results of optional testing with those of standard ones.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (4) , 2208-2215
Method for Reducing Sediment Formation in Transformer Oil
The leading position among liquid dielectrics used in high-voltage equipment is occupied by transformer oil. Over 130 years of using insulating oil, a lot of valuable information has been obtained, in particular: about the condition of the oil during its operation; about methods for restoring its characteristics; known methods of protection against active oxidation; methods for monitoring oil parameters and assessing the condition of the insulation system of oil-filled equipment have been developed. Despite the fact that mineral oils cope quite well with their functions - insulation and heat removal, there are a number of properties that do not meet the requirements of modern energy. Thus, in terms of fire resistance, chemical stability and biodegradability, transformer oils are significantly inferior to ester dielectric fluids, which are quite widely used by foreign energy companies. In addition, transformer oils, during their prolonged use in electrical equipment, are capable of forming sediments of various consistencies. For efficient and reliable operation of the insulation system, such precipitation is extremely undesirable. This article proposes a method for optimizing the properties of transformer oil (aromatic, paraffin) to stabilize the sedimentation process by mixing the oil with a synthetic ester in a certain ratio.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (4) , 2208-2215
Method for Reducing Sediment Formation in Transformer Oil
The leading position among liquid dielectrics used in high-voltage equipment is occupied by transformer oil. Over 130 years of using insulating oil, a lot of valuable information has been obtained, in particular: about the condition of the oil during its operation; about methods for restoring its characteristics; known methods of protection against active oxidation; methods for monitoring oil parameters and assessing the condition of the insulation system of oil-filled equipment have been developed. Despite the fact that mineral oils cope quite well with their functions - insulation and heat removal, there are a number of properties that do not meet the requirements of modern energy. Thus, in terms of fire resistance, chemical stability and biodegradability, transformer oils are significantly inferior to ester dielectric fluids, which are quite widely used by foreign energy companies. In addition, transformer oils, during their prolonged use in electrical equipment, are capable of forming sediments of various consistencies. For efficient and reliable operation of the insulation system, such precipitation is extremely undesirable. This article proposes a method for optimizing the properties of transformer oil (aromatic, paraffin) to stabilize the sedimentation process by mixing the oil with a synthetic ester in a certain ratio.
- 1 November 2023
- Published by Springer Nature in Power Technology and Engineering
- Vol. 57 (4) , 615-622
Dielectric Liquids: Past, Present, Future (Review)
- 1 November 2023
- Published by Springer Nature in Power Technology and Engineering
- Vol. 57 (4) , 615-622
Dielectric Liquids: Past, Present, Future (Review)
- Open Access
- 1 January 2023
- Published by Ural Federal University in Аналитика и контроль
- Vol. 27 (2) , 113-121
DETERMINATION OF PHENOLIC-TYPE ANTIOXIDANT ADDITIVES IN FRESH INSULATING OILS BY IR SPECTROMETRY ON A LIQUID EXPRESS ANALYZER ATTACHMENT
For more than 120 years, transformer oil, derived from oil, has been most widely used as an insulating and heat dissipating medium in oil-paper insulated electrical equipment. During operation, under the influence of such factors as elevated temperature of the windings, electric field, contact with air oxygen and metal parts of the equipment, the oil is oxidized resulting in the deterioration of its electrical insulation properties and creating the risk of failure of expensive electrical equipment. In order to slow down the oxidation process and extend the life of the oil, the inhibiting additive ionol is added. However, in previously published works we showed that the additive ionol itself also undergoes decomposition with the formation of other phenolic compounds, which presence acts as an additional indicator of intensive aging of the liquid dielectric. Therefore, it is advisable to control in fresh transformer oils not only the content of ionol itself but also the presence of its degradation products showing similar inhibitory properties. A method of quantitative determination of ionol (2,6-di-tret-butyl-4-methylphenol) as well as 2,6-di-tret-butylphenol is proposed in the present work. The method of analysis is based on the IR spectrometry using a liquid express analysis attachment. The proposed method has a number of advantages over other methods, including standardized methods, i.e. speed; simplicity; safety, since chemical reagents are not required; low cost of consumables.
- 1 January 2023
- Published by Ural Federal University in Аналитика и контроль
- Vol. 27 (2) , 113-121
Open AccessDETERMINATION OF PHENOLIC-TYPE ANTIOXIDANT ADDITIVES IN FRESH INSULATING OILS BY IR SPECTROMETRY ON A LIQUID EXPRESS ANALYZER ATTACHMENT
For more than 120 years, transformer oil, derived from oil, has been most widely used as an insulating and heat dissipating medium in oil-paper insulated electrical equipment. During operation, under the influence of such factors as elevated temperature of the windings, electric field, contact with air oxygen and metal parts of the equipment, the oil is oxidized resulting in the deterioration of its electrical insulation properties and creating the risk of failure of expensive electrical equipment. In order to slow down the oxidation process and extend the life of the oil, the inhibiting additive ionol is added. However, in previously published works we showed that the additive ionol itself also undergoes decomposition with the formation of other phenolic compounds, which presence acts as an additional indicator of intensive aging of the liquid dielectric. Therefore, it is advisable to control in fresh transformer oils not only the content of ionol itself but also the presence of its degradation products showing similar inhibitory properties. A method of quantitative determination of ionol (2,6-di-tret-butyl-4-methylphenol) as well as 2,6-di-tret-butylphenol is proposed in the present work. The method of analysis is based on the IR spectrometry using a liquid express analysis attachment. The proposed method has a number of advantages over other methods, including standardized methods, i.e. speed; simplicity; safety, since chemical reagents are not required; low cost of consumables.
- 1 January 2023
- Published by FSB EIHE Omsk State Technical University in Omsk Scientific Bulletin
Application of chromato-mass spectrometry to determine the acid composition of transformer oil
This article presents the results of a study of the acid composition of transformer oil from high-voltage transformers that have been in operation for more than 30 years. The acid composition of oils is studied using a new technique based on a highly sensitive and highly selective analysis method — chromato-mass spectrometry. The technique makes it possible to determine the acid composition of the insulating oil in the context of low molecular weight acids (LMA), high molecular weight acids (HMA) and phenolic compounds (PC). The structure of some compounds identified in oil is given. It has been established that during oil aging, among the acid compounds, the following are predominantly formed: HMA (60–95 %) > PC (3–16 %) > LMA (1–6 %). As part of the research, it is found that the share of the most dangerous low molecular weight acids in the total amount of acidic compounds is no more than 12 %. The rest of the acidity of the oil is due to the presence of macromolecular and phenolic compounds, which do not adversely affect the insulating properties of oil and paper in the detected concentrations, and some of them (compounds of a phenolic nature), on the contrary, even improve the stability against oxidation. These extended tests of oil samples from operating high-voltage equipment are of practical value in preventive diagnostics of the condition of its insulation.
- 1 January 2023
- Published by FSB EIHE Omsk State Technical University in Omsk Scientific Bulletin
Application of chromato-mass spectrometry to determine the acid composition of transformer oil
This article presents the results of a study of the acid composition of transformer oil from high-voltage transformers that have been in operation for more than 30 years. The acid composition of oils is studied using a new technique based on a highly sensitive and highly selective analysis method — chromato-mass spectrometry. The technique makes it possible to determine the acid composition of the insulating oil in the context of low molecular weight acids (LMA), high molecular weight acids (HMA) and phenolic compounds (PC). The structure of some compounds identified in oil is given. It has been established that during oil aging, among the acid compounds, the following are predominantly formed: HMA (60–95 %) > PC (3–16 %) > LMA (1–6 %). As part of the research, it is found that the share of the most dangerous low molecular weight acids in the total amount of acidic compounds is no more than 12 %. The rest of the acidity of the oil is due to the presence of macromolecular and phenolic compounds, which do not adversely affect the insulating properties of oil and paper in the detected concentrations, and some of them (compounds of a phenolic nature), on the contrary, even improve the stability against oxidation. These extended tests of oil samples from operating high-voltage equipment are of practical value in preventive diagnostics of the condition of its insulation.
- 1 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (6) , 2181-2189
The Breakdown Voltage of Moistened Mineral Oil During Its Cooling
In high voltage oil-filled equipment, mineral insulating oil has two main functions - to remove heat from heated parts and to insulate conductors. Regardless of the temperature, transformer oil must always provide reliable insulation of high-voltage equipment elements. The primary indicator characterizing the electrical insulating properties of mineral oil is its electrical strength. This work presents the results of the study, which reflect the change in the value of the breakdown voltage of the oil during its cooling from + 60 °C to -20 °C. Modeling shows that when the cell is cooled, together with its contents, conditions are realized on the electrodes for the predominant formation of water in the form of drops or ice particles. Such an experiment and simulation shows the processes occurring in the insulation of a power transformer during its forced commissioning and decommissioning at negative temperatures. Experimental data on the nature of changes in the breakdown voltage of a liquid dielectric depending on the cooling method and the degree of oil oxidation are presented. Ice crystals form in the oil as it cools, the shape of which is different. It was found that in the process of oil cooling in the interelectrode gap, an “ice cloud” or “ice bridge” is formed. During thawing, emulsion water is formed from ice inclusions, which are concentrated on the electrodes of the measuring cell. It was experimentally determined that under high voltage action in small gaps of the measuring cell, water droplets are drawn out, forming a "water bridge" between the electrodes.
- 1 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (6) , 2181-2189
The Breakdown Voltage of Moistened Mineral Oil During Its Cooling
In high voltage oil-filled equipment, mineral insulating oil has two main functions - to remove heat from heated parts and to insulate conductors. Regardless of the temperature, transformer oil must always provide reliable insulation of high-voltage equipment elements. The primary indicator characterizing the electrical insulating properties of mineral oil is its electrical strength. This work presents the results of the study, which reflect the change in the value of the breakdown voltage of the oil during its cooling from + 60 °C to -20 °C. Modeling shows that when the cell is cooled, together with its contents, conditions are realized on the electrodes for the predominant formation of water in the form of drops or ice particles. Such an experiment and simulation shows the processes occurring in the insulation of a power transformer during its forced commissioning and decommissioning at negative temperatures. Experimental data on the nature of changes in the breakdown voltage of a liquid dielectric depending on the cooling method and the degree of oil oxidation are presented. Ice crystals form in the oil as it cools, the shape of which is different. It was found that in the process of oil cooling in the interelectrode gap, an “ice cloud” or “ice bridge” is formed. During thawing, emulsion water is formed from ice inclusions, which are concentrated on the electrodes of the measuring cell. It was experimentally determined that under high voltage action in small gaps of the measuring cell, water droplets are drawn out, forming a "water bridge" between the electrodes.
- 1 May 2021
- Published by Springer Nature in Power Technology and Engineering
- Vol. 55 (1) , 136-142
New Insulating Fluids and Diagnostic Techniques for Paper-Oil Insulated Equipment1
In 2021, the International Council on Large Electric Systems (CIGRE) will celebrate its centenary. CIGRE Sessions are traditionally held face-to-face in Paris once every even-numbered year. However, in 2020, in response to the coronavirus pandemic, the organizers of the 48th CIGRE Session decided to hold a virtual meeting for experts, specialists, engineers, and researchers from all over the world. The result was an e-session that included engaging seminars, tutorials, and discussions. At the virtual meeting, participants discussed various problems and challenges currently affecting all areas of the energy sector. Current pressing issues include the development of informative diagnostic techniques for oil-filled equipment, as well as the potential applicability of environmentally friendly biodegradable synthetic and natural esters for use as liquid insulation in high-voltage equipment. This review presents the latest research, practical solutions and reports on the experience of applying new techniques and novel liquid insulating materials. Valuable and up-to-date information in these fields is provided by experts and specialists from all over the world.
- 1 May 2021
- Published by Springer Nature in Power Technology and Engineering
- Vol. 55 (1) , 136-142
New Insulating Fluids and Diagnostic Techniques for Paper-Oil Insulated Equipment1
In 2021, the International Council on Large Electric Systems (CIGRE) will celebrate its centenary. CIGRE Sessions are traditionally held face-to-face in Paris once every even-numbered year. However, in 2020, in response to the coronavirus pandemic, the organizers of the 48th CIGRE Session decided to hold a virtual meeting for experts, specialists, engineers, and researchers from all over the world. The result was an e-session that included engaging seminars, tutorials, and discussions. At the virtual meeting, participants discussed various problems and challenges currently affecting all areas of the energy sector. Current pressing issues include the development of informative diagnostic techniques for oil-filled equipment, as well as the potential applicability of environmentally friendly biodegradable synthetic and natural esters for use as liquid insulation in high-voltage equipment. This review presents the latest research, practical solutions and reports on the experience of applying new techniques and novel liquid insulating materials. Valuable and up-to-date information in these fields is provided by experts and specialists from all over the world.
- 10 October 2020
- Published by Springer Nature in Power Technology and Engineering
- Vol. 54 (4) , 594-599
Identification of Impurities of Unknown Composition in Insulating Oil by Gas Chromatography-Mass Spectrometry (GC-MS)
- 10 October 2020
- Published by Springer Nature in Power Technology and Engineering
- Vol. 54 (4) , 594-599
Identification of Impurities of Unknown Composition in Insulating Oil by Gas Chromatography-Mass Spectrometry (GC-MS)