Jingyao Luan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jingyao Luan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Lixin Jiao
China Electric Power Research Institute, Beijing 100192, China
2 shared publications - Peng Zhang
Faculty of Engineering, China University of Geosciences, Wuhan 430074, China
2 shared publications - Bin Zhang
State Grid ShanDong Electric Power Company of Construction Company, Jinan 250001, China
1 shared publication - Junbo Liu
Electric Power Research Institute of State Grid Jilin Electric Power CO., LTD., ChangChun 130021, China
1 shared publication - Li Chen
State Grid ShanDong Electric Power Company of Construction Company, Jinan 250001, China
1 shared publication - Xi Li
State Grid Shandong Electric Power Company, Jinan 250001, China
1 shared publication
Latest Publications
- Open Access
Research on Axial Stress and Strain Characteristics of Reinforced-Concrete Curved Pipe Jacking in Power Tunnels
Joint deflection during curved pipe jacking in power tunnels poses a significant risk of structural failure due to the resulting eccentric and diagonal loading on the pipes. This study investigated the axial stress and strain characteristics of reinforced-concrete pipes under varying joint deflection angles and jacking forces, using a combined approach of experimental model testing and finite element method (FEM) numerical simulations. The experimental setup replicated curved pipe jacking conditions, allowing for the measurement of strains and deformation under controlled loading. Numerical simulations, validated against experimental data, provided detailed insights into the stress distribution patterns. The results revealed distinct stress states in different pipe sections. The pipe closest to the jacking force (3# pipe) experienced eccentric loading, leading to localized stress concentrations and inelastic strain on the inner wall at the point of eccentricity, indicating vulnerability to compressive failure. The middle pipe section (2# pipe) underwent complex diagonal loading, resulting in the development of inelastic strain on both the inner and outer walls at specific orientations, highlighting a risk of both compressive and shear failure modes. The study also demonstrated that the magnitude of the axial jacking force and the degree of joint deflection significantly influence the stress distribution and the extent of inelastic strain. These findings provide important information for optimizing the design and construction of curved pipe jacking projects in power tunnels. The identified failure mechanisms and the influence of key parameters on pipe behavior can inform strategies to mitigate the risk of structural failure, improve the resilience of pipe systems, and enhance the overall safety and reliability of underground power tunnel infrastructure.
Open AccessResearch on Axial Stress and Strain Characteristics of Reinforced-Concrete Curved Pipe Jacking in Power Tunnels
Joint deflection during curved pipe jacking in power tunnels poses a significant risk of structural failure due to the resulting eccentric and diagonal loading on the pipes. This study investigated the axial stress and strain characteristics of reinforced-concrete pipes under varying joint deflection angles and jacking forces, using a combined approach of experimental model testing and finite element method (FEM) numerical simulations. The experimental setup replicated curved pipe jacking conditions, allowing for the measurement of strains and deformation under controlled loading. Numerical simulations, validated against experimental data, provided detailed insights into the stress distribution patterns. The results revealed distinct stress states in different pipe sections. The pipe closest to the jacking force (3# pipe) experienced eccentric loading, leading to localized stress concentrations and inelastic strain on the inner wall at the point of eccentricity, indicating vulnerability to compressive failure. The middle pipe section (2# pipe) underwent complex diagonal loading, resulting in the development of inelastic strain on both the inner and outer walls at specific orientations, highlighting a risk of both compressive and shear failure modes. The study also demonstrated that the magnitude of the axial jacking force and the degree of joint deflection significantly influence the stress distribution and the extent of inelastic strain. These findings provide important information for optimizing the design and construction of curved pipe jacking projects in power tunnels. The identified failure mechanisms and the influence of key parameters on pipe behavior can inform strategies to mitigate the risk of structural failure, improve the resilience of pipe systems, and enhance the overall safety and reliability of underground power tunnel infrastructure.
- Open Access
FEM-Based Analysis of the Loading Capacity of Defective Cable Tunnel Structures
With the popularized application of underground cable tunnels in China, various structural defects such as cracking, deforming and material deteriorating also emerge. In cable tunnels that have been poorly maintained for a long time, there is always a coexistence of several kinds of defects, and with the current methods of monitoring, it is difficult to identify the major defect affecting the load-carrying capacity and resolve it. However, the finite element method (FEM) can better solve this problem by analyzing the effect of a single defect parameter separately. In this paper, four different types of cable tunnels, namely the circular, rectangular, arched and trenched sectional tunnels, are modelled and analyzed with FEM. Defect parameters, including crack dimensions and concrete deterioration, are considered as variables, which are controlled and studied respectively. The results of the simulation indicate that the impact of crack propagation on the residual-bearing capacity of cable tunnels is much larger than that of concrete deterioration, especially the deepening of cracks. Works in this paper have the potential to be further referenced for cable-tunnel structure estimation and defect prevention.
Open AccessFEM-Based Analysis of the Loading Capacity of Defective Cable Tunnel Structures
With the popularized application of underground cable tunnels in China, various structural defects such as cracking, deforming and material deteriorating also emerge. In cable tunnels that have been poorly maintained for a long time, there is always a coexistence of several kinds of defects, and with the current methods of monitoring, it is difficult to identify the major defect affecting the load-carrying capacity and resolve it. However, the finite element method (FEM) can better solve this problem by analyzing the effect of a single defect parameter separately. In this paper, four different types of cable tunnels, namely the circular, rectangular, arched and trenched sectional tunnels, are modelled and analyzed with FEM. Defect parameters, including crack dimensions and concrete deterioration, are considered as variables, which are controlled and studied respectively. The results of the simulation indicate that the impact of crack propagation on the residual-bearing capacity of cable tunnels is much larger than that of concrete deterioration, especially the deepening of cracks. Works in this paper have the potential to be further referenced for cable-tunnel structure estimation and defect prevention.