FEM-Based Analysis of the Loading Capacity of Defective Cable Tunnel Structures
Open Access
Abstract
With the popularized application of underground cable tunnels in China, various structural defects such as cracking, deforming and material deteriorating also emerge. In cable tunnels that have been poorly maintained for a long time, there is always a coexistence of several kinds of defects, and with the current methods of monitoring, it is difficult to identify the major defect affecting the load-carrying capacity and resolve it. However, the finite element method (FEM) can better solve this problem by analyzing the effect of a single defect parameter separately. In this paper, four different types of cable tunnels, namely the circular, rectangular, arched and trenched sectional tunnels, are modelled and analyzed with FEM. Defect parameters, including crack dimensions and concrete deterioration, are considered as variables, which are controlled and studied respectively. The results of the simulation indicate that the impact of crack propagation on the residual-bearing capacity of cable tunnels is much larger than that of concrete deterioration, especially the deepening of cracks. Works in this paper have the potential to be further referenced for cable-tunnel structure estimation and defect prevention.Keywords
Funding Information
- State Grid Co., Ltd. of China (SGTYHT/19-JS-215)
This publication has 9 references indexed in Scilit:
- Structural performance of damaged rigid pipe rehabilitated by centrifugal spray on mortar linerTunnelling and Underground Space Technology, 2021
- Modeling structural behavior of reinforced-concrete pipe with single, double and triple cage reinforcementEngineering Structures, 2021
- Durability Study on High-Performance Fiber-Reinforced Mortar under Simulated Wastewater Pipeline EnvironmentMaterials, 2021
- Modeling structural behavior of precast concrete pipe with single elliptical steel cage reinforcementStructures, 2020
- Experimental Study and Numerical Simulation of Three-Edge Bearing Test of Large Diameter Prestressed Concrete Cylinder Pipes2018
- Rational finite element assisted design of precast steel fibre reinforced concrete pipesEngineering Structures, 2016
- Effect of Mortar Coating’s Bond Quality on the Structural Integrity of Prestressed Concrete Cylinder Pipe with Broken WiresJournal of Materials Science Research, 2015
- Modelling of reinforced concrete structures and composite structures with concrete strength degradation taken into considerationArchives of Civil and Mechanical Engineering, 2011
- Buried Pipes and Culverts2001