JLJing Li

Jing Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jing Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Ultrasensitive QCM Humidity Sensor Based on GO/OH-GQDs

    by Xing Ding, Jing Li, Wei Hu, Xiangdong Chen, Wenhe Xia

    Sensitivity is one of the most important characteristics of QCM humidity sensors, and the methods to improve the sensitivity have always been the research focus in the field of QCM humidity sensors. This study proposes an ultra-sensitive (179.88 Hz/%RH) QCM humidity sensor using Graphene Oxide (GO) and Hydroxylated Graphene Quantum Dots (OH-GQDs) as the sensitive materials. The experimental results show that the incorporation of OH-GQDs significantly increases the number of active sites on the GO, and the GO/OH-GQDs composite has a larger specific surface area, which greatly increases the water absorption capacity. In addition, the sensor also has a low humidity hysteresis (1.3%), fast response and recovery times (7 s/10 s), good stability, and good repeatability. This sensor’s ultra-high sensitivity suggests significant potential for advancing the development of high-performance QCM humidity sensors.


  • A Highly Linear and Sensitive QCM Humidity Sensor Based on High-Frequency Quartz Crystal Transducer

    by Xing Ding, Jing Li, Kun Tang, Xiangdong Chen, Hui Li

    Sensitivity and linearity are two crucial parameters in the context of quartz crystal microbalance (QCM) humidity sensors. Achieving a highly sensitive response in a QCM-based humidity sensor involves employing a significant mass of humidity-sensitive material. However, this approach may introduce a viscosity effect, leading to a nonlinear response from the sensor. The Sauerbrey equation suggests that a QCM device exhibits a linear mass-frequency response when a micro-mass is deposited on its surface. In this study, we present a design strategy for a QCM humidity sensor based on a small-size, high-frequency QCM transducer. A minimal mass (1 μg) of graphene oxide serves as the moisture-sensitive material and is deposited on a 16-MHz QCM device enclosed in a 5032 package, resulting in the fabrication of a QCM humidity sensor. The sensor demonstrates both high sensitivity (82.40 Hz/%RH) and high linearity (adjusted R-square: 0.9892) across a relative humidity range of 11% to 97%. Furthermore, the sensor exhibits low humidity hysteresis (2.5% RH), excellent stability, and repeatability. The methodology proposed in this paper is anticipated to contribute to the development of high-performance QCM humidity sensors.


  • Derivation for Mass–Frequency Relationship of a Quartz Crystal Microbalance Based on an Equivalent Circuit Network Analysis Method

    by Xing Ding, Jing Li, Xiangdong Chen, Jiashu Zhang, Mingxin Zhu

    Saurbrey equation has solved frequency dependence on mass change for a rigid film on a quartz crystal microbalance device. Does it hold true for any rigid film that is deposited on a quartz crystal microbalance? A new expression for the mass–frequency relationship of a quartz crystal microbalance device is derived based on equivalent circuit network analysis combined with physical properties of the quartz crystal. Compared to Sauerbrey equation, the proposed expression is derived without applying any approximations. Theoretical analysis is validated with finite-element analysis and experimental test. The results demonstrate that frequency shift of a quartz crystal microbalance is related not only to mass of the deposited addition but also density of the deposited addition. This work is significant to supplement and extend the theory of quartz crystal microbalance.