Xing Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xing Ding has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Xiangdong Chen
Southwest Jiaotong University
7 shared publications - Kun Tang
School of Information Science and Technology, Southwest Jiaotong University, Chengdu, China
5 shared publications - Xiang Yu
School of Information Science and Technology, Southwest Jiaotong University, Chengdu, China
4 shared publications - Fang Liu
Southwest Jiaotong University
2 shared publications - Haochi Ying
School of Information Science and Technology, Southwest Jiaotong University, Chengdu, China
2 shared publications - Jiaqi Lu
Southwest Jiaotong University
2 shared publications
Latest Publications
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
High-Sensitivity and Low-Hysteresis QC-IDE Humidity Sensor Based on GO/Nafion Hybrid Film
To enable reliable detection of dynamic humidity variations under complex environmental conditions in meteorological applications, there is an increasing demand for humidity sensors that combine high sensitivity with low hysteresis. In this study, a humidity sensor was prepared based on a quartz crystal in series with interdigital electrode (QC-IDE) structure. The sensor realizes humidity sensing through the resistance-capacitance modulation mechanism: the GO/Nafion composite material is dropped on the IDE surface to form a humidity sensitive film. The variation in ambient humidity induces adsorption or desorption of water molecules on the QC-IDE humidity sensor, thereby modulating its equivalent resistance and capacitance and consequently shifting its resonant frequency. The experimental results show that the sensor with GO/Nafion mass ratio of 3:25 has the best performance. The sensitivity is 89.54 Hz/%RH, the humidity hysteresis is 0.39% RH, and the response/recovery time is 12 s and 4 s, respectively. The humidity sensing performance of the sensor may be attributed to the fold morphology and hydrophilic functional groups of the GO/Nafion sensitive film, which together provide a large specific surface area and enhance the adsorption of water molecules. In addition, the sensor showed good repeatability and stability. This study provides a feasible technical approach for the fabrication of humidity sensors with high sensitivity and low hysteresis.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
High-Sensitivity and Low-Hysteresis QC-IDE Humidity Sensor Based on GO/Nafion Hybrid Film
To enable reliable detection of dynamic humidity variations under complex environmental conditions in meteorological applications, there is an increasing demand for humidity sensors that combine high sensitivity with low hysteresis. In this study, a humidity sensor was prepared based on a quartz crystal in series with interdigital electrode (QC-IDE) structure. The sensor realizes humidity sensing through the resistance-capacitance modulation mechanism: the GO/Nafion composite material is dropped on the IDE surface to form a humidity sensitive film. The variation in ambient humidity induces adsorption or desorption of water molecules on the QC-IDE humidity sensor, thereby modulating its equivalent resistance and capacitance and consequently shifting its resonant frequency. The experimental results show that the sensor with GO/Nafion mass ratio of 3:25 has the best performance. The sensitivity is 89.54 Hz/%RH, the humidity hysteresis is 0.39% RH, and the response/recovery time is 12 s and 4 s, respectively. The humidity sensing performance of the sensor may be attributed to the fold morphology and hydrophilic functional groups of the GO/Nafion sensitive film, which together provide a large specific surface area and enhance the adsorption of water molecules. In addition, the sensor showed good repeatability and stability. This study provides a feasible technical approach for the fabrication of humidity sensors with high sensitivity and low hysteresis.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
A High Quality Factor QCM Humidity Sensor Based on Liquid Damping Isolation Strategy of Silica Supported GO Film
Quartz crystal microbalance (QCM) sensors have garnered significant interest in humidity sensor filed due to the excellent advantages of nanogram-level theoretical mass resolution and digital frequency output, etc. However, a key limitation is the substantial energy dissipation in high humidity detection, which results in a low quality-factor (Q-factor), thereby restricting sensitivity and measurement accuracy. To address this issue, we developed a high-Q humidity sensor utilizing a liquid damping isolation strategy. In this design, the graphene oxide (GO) humidity-sensitive layer is supported and isolated by hydrophobic SiO₂ spheres, forming a SiO₂/GO bilayer structure. Experimental results demonstrate that the SiO₂/GO bilayer QCM humidity sensor achieves a high Q value of 66,084 at 97% RH, which is three times greater than that of the pure GO QCM sensor and surpasses previously reported values, demonstrating the excellent stability and the effectiveness of the proposed liquid damping isolation strategy for fabricating a high Q-factor QCM humidity sensor. In addition, the SiO2/GO bilayer structure QCM humidity sensor suggested an ultrafast recovery time (<1 s), good short-term and long-term stability. Based on the outstanding high humidity resistance, the sensor was applied for stable human breath monitoring. This work not only provides a novel idea and valuable reference for high performance QCM sensor fabrication, but also provides a reliable way for human health monitoring based on QCM humidity sensors.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
A High Quality Factor QCM Humidity Sensor Based on Liquid Damping Isolation Strategy of Silica Supported GO Film
Quartz crystal microbalance (QCM) sensors have garnered significant interest in humidity sensor filed due to the excellent advantages of nanogram-level theoretical mass resolution and digital frequency output, etc. However, a key limitation is the substantial energy dissipation in high humidity detection, which results in a low quality-factor (Q-factor), thereby restricting sensitivity and measurement accuracy. To address this issue, we developed a high-Q humidity sensor utilizing a liquid damping isolation strategy. In this design, the graphene oxide (GO) humidity-sensitive layer is supported and isolated by hydrophobic SiO₂ spheres, forming a SiO₂/GO bilayer structure. Experimental results demonstrate that the SiO₂/GO bilayer QCM humidity sensor achieves a high Q value of 66,084 at 97% RH, which is three times greater than that of the pure GO QCM sensor and surpasses previously reported values, demonstrating the excellent stability and the effectiveness of the proposed liquid damping isolation strategy for fabricating a high Q-factor QCM humidity sensor. In addition, the SiO2/GO bilayer structure QCM humidity sensor suggested an ultrafast recovery time (<1 s), good short-term and long-term stability. Based on the outstanding high humidity resistance, the sensor was applied for stable human breath monitoring. This work not only provides a novel idea and valuable reference for high performance QCM sensor fabrication, but also provides a reliable way for human health monitoring based on QCM humidity sensors.
- 29 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (12) , 22747-22755
Highly Sensitive Detection of Water Content in Ethanol Based on a Resistive-Capacitive Frequency Modulation Method
The accurate detection of water content in ethanol is crucial for various industrial processes, such as fuel production and chemical manufacturing. However, existing methods face challenges in terms of sensitivity, stability, and repeatability. This paper presents a new method for detecting the water content in ethanol based on a resonant sensor with a quartz crystal (QC) in series with a interdigital electrode (IDE), called QC-IDE circuit. Theoretical analysis indicates that variations in the equivalent capacitance and resistance of the IDE can influence the response frequency of the QC-IDE circuit. The QC-IDE circuit features two key frequency modulation ranges: one occurs when the IDE resistance Rs > 50 kΩ and the capacitance Cs < 50 pF, the other occurs when the resistance 1 kΩ < Rs < 10 kΩ and the capacitance Cs < 20 pF. The QC-IDE resonator sensor was prepared by adjusting the characterization parameters of IDE , such as electrode spacing and linewidth, and the water content in ethanol was tested in the range of 0% to 100% volume (vol.). Through comprehensive evaluation, the optimal electrode parameter configuration for the QC-IDE circuit was determined. Experimental results demonstrate that the developed sensor achieved a response sensitivity of up to 29.36 Hz/(% vol.) and exhibited good linearity of low water content , stability, and repeatability. These findings suggest that the proposed QC-IDE sensor holds significant potential for applications in ethanol water content detection.
- 29 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (12) , 22747-22755
Highly Sensitive Detection of Water Content in Ethanol Based on a Resistive-Capacitive Frequency Modulation Method
The accurate detection of water content in ethanol is crucial for various industrial processes, such as fuel production and chemical manufacturing. However, existing methods face challenges in terms of sensitivity, stability, and repeatability. This paper presents a new method for detecting the water content in ethanol based on a resonant sensor with a quartz crystal (QC) in series with a interdigital electrode (IDE), called QC-IDE circuit. Theoretical analysis indicates that variations in the equivalent capacitance and resistance of the IDE can influence the response frequency of the QC-IDE circuit. The QC-IDE circuit features two key frequency modulation ranges: one occurs when the IDE resistance Rs > 50 kΩ and the capacitance Cs < 50 pF, the other occurs when the resistance 1 kΩ < Rs < 10 kΩ and the capacitance Cs < 20 pF. The QC-IDE resonator sensor was prepared by adjusting the characterization parameters of IDE , such as electrode spacing and linewidth, and the water content in ethanol was tested in the range of 0% to 100% volume (vol.). Through comprehensive evaluation, the optimal electrode parameter configuration for the QC-IDE circuit was determined. Experimental results demonstrate that the developed sensor achieved a response sensitivity of up to 29.36 Hz/(% vol.) and exhibited good linearity of low water content , stability, and repeatability. These findings suggest that the proposed QC-IDE sensor holds significant potential for applications in ethanol water content detection.
- 21 February 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 408
A sub-second QCM humidity sensor with low hysteresis base on Nafion thin film
- 21 February 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 408
A sub-second QCM humidity sensor with low hysteresis base on Nafion thin film
- 28 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
A Highly Linear and Sensitive QCM Humidity Sensor Based on High-Frequency Quartz Crystal Transducer
Sensitivity and linearity are two crucial parameters in the context of quartz crystal microbalance (QCM) humidity sensors. Achieving a highly sensitive response in a QCM-based humidity sensor involves employing a significant mass of humidity-sensitive material. However, this approach may introduce a viscosity effect, leading to a nonlinear response from the sensor. The Sauerbrey equation suggests that a QCM device exhibits a linear mass-frequency response when a micro-mass is deposited on its surface. In this study, we present a design strategy for a QCM humidity sensor based on a small-size, high-frequency QCM transducer. A minimal mass (1 μg) of graphene oxide serves as the moisture-sensitive material and is deposited on a 16-MHz QCM device enclosed in a 5032 package, resulting in the fabrication of a QCM humidity sensor. The sensor demonstrates both high sensitivity (82.40 Hz/%RH) and high linearity (adjusted R-square: 0.9892) across a relative humidity range of 11% to 97%. Furthermore, the sensor exhibits low humidity hysteresis (2.5% RH), excellent stability, and repeatability. The methodology proposed in this paper is anticipated to contribute to the development of high-performance QCM humidity sensors.
- 28 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
A Highly Linear and Sensitive QCM Humidity Sensor Based on High-Frequency Quartz Crystal Transducer
Sensitivity and linearity are two crucial parameters in the context of quartz crystal microbalance (QCM) humidity sensors. Achieving a highly sensitive response in a QCM-based humidity sensor involves employing a significant mass of humidity-sensitive material. However, this approach may introduce a viscosity effect, leading to a nonlinear response from the sensor. The Sauerbrey equation suggests that a QCM device exhibits a linear mass-frequency response when a micro-mass is deposited on its surface. In this study, we present a design strategy for a QCM humidity sensor based on a small-size, high-frequency QCM transducer. A minimal mass (1 μg) of graphene oxide serves as the moisture-sensitive material and is deposited on a 16-MHz QCM device enclosed in a 5032 package, resulting in the fabrication of a QCM humidity sensor. The sensor demonstrates both high sensitivity (82.40 Hz/%RH) and high linearity (adjusted R-square: 0.9892) across a relative humidity range of 11% to 97%. Furthermore, the sensor exhibits low humidity hysteresis (2.5% RH), excellent stability, and repeatability. The methodology proposed in this paper is anticipated to contribute to the development of high-performance QCM humidity sensors.
- 12 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (5) , 5318-5327
An FPGA-Accelerated Quartz Crystal Measurement System Based on a Negative Feedback Loop With Quadrature Demodulation
Rapid measurement of the resonant frequency of quartz crystal (QC) devices plays a key role in applying QC-based dynamic monitoring, such as respiration monitoring and kinetic process in electrochemical reactions. This work develops an FPGA-accelerated QC measurement system without software-based curve fitting. A negative feedback loop based on the susceptance response collected by the quadrature demodulation circuit is constructed. Moreover, a proportional-integral-differential control and tracking strategy is applied to improve the measurement speed significantly. The test results show that the implemented system can track a frequency shift of 5 kHz bandwidth within 50 ms. The standard deviation of the measured frequency of a QC device under test is only 0.17 Hz, which indicates that the proposed system is high stability and high precision. The frequency measurement results have a relative error of 0.8 ppm compared with the Agilent 4294A impedance analyzer. It is demonstrated that the proposed QC measurement system has great potential for QC-based dynamic detection.
- 12 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (5) , 5318-5327
An FPGA-Accelerated Quartz Crystal Measurement System Based on a Negative Feedback Loop With Quadrature Demodulation
Rapid measurement of the resonant frequency of quartz crystal (QC) devices plays a key role in applying QC-based dynamic monitoring, such as respiration monitoring and kinetic process in electrochemical reactions. This work develops an FPGA-accelerated QC measurement system without software-based curve fitting. A negative feedback loop based on the susceptance response collected by the quadrature demodulation circuit is constructed. Moreover, a proportional-integral-differential control and tracking strategy is applied to improve the measurement speed significantly. The test results show that the implemented system can track a frequency shift of 5 kHz bandwidth within 50 ms. The standard deviation of the measured frequency of a QC device under test is only 0.17 Hz, which indicates that the proposed system is high stability and high precision. The frequency measurement results have a relative error of 0.8 ppm compared with the Agilent 4294A impedance analyzer. It is demonstrated that the proposed QC measurement system has great potential for QC-based dynamic detection.
- 25 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (11) , 11547-11553
Highly Sensitive QCM Humidity Sensor Based on Fullerenol-Assisted Dispersion of Nafion/MWCNTs Composites
Water seepage of building walls is a common problem in our lives. However, the lack of early seepage detection methods often makes the problem worse. To develop effective early wall seepage detection methods, an ultra-sensitive quartz crystal microbalance (QCM) humidity sensor based on fullerenol (C 60 -OH)-assisted dispersion of Nafion/multi-walled carbon nanotubes (MWCNTs) composites is proposed. The prepared sensor shows almost 7 times higher frequency shift than pure Nafion-based sensor, which reaches -10814 Hz. This is mainly attributed to the uniform dispersion of MWCNTs in the Nafion with the assistance of C 60 -OH to form a reticular structure that generates more voids, which greatly improves the diffusion ability of water molecules in the composite materials and thus further enhances humidity sensing properties of the sensor. The high-performance QCM humidity sensor is expected to be used for early detection of water seepage in building walls by monitoring air humidity changes near the wall surface.
- 25 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (11) , 11547-11553
Highly Sensitive QCM Humidity Sensor Based on Fullerenol-Assisted Dispersion of Nafion/MWCNTs Composites
Water seepage of building walls is a common problem in our lives. However, the lack of early seepage detection methods often makes the problem worse. To develop effective early wall seepage detection methods, an ultra-sensitive quartz crystal microbalance (QCM) humidity sensor based on fullerenol (C 60 -OH)-assisted dispersion of Nafion/multi-walled carbon nanotubes (MWCNTs) composites is proposed. The prepared sensor shows almost 7 times higher frequency shift than pure Nafion-based sensor, which reaches -10814 Hz. This is mainly attributed to the uniform dispersion of MWCNTs in the Nafion with the assistance of C 60 -OH to form a reticular structure that generates more voids, which greatly improves the diffusion ability of water molecules in the composite materials and thus further enhances humidity sensing properties of the sensor. The high-performance QCM humidity sensor is expected to be used for early detection of water seepage in building walls by monitoring air humidity changes near the wall surface.
- 2 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Derivation for Mass–Frequency Relationship of a Quartz Crystal Microbalance Based on an Equivalent Circuit Network Analysis Method
Saurbrey equation has solved frequency dependence on mass change for a rigid film on a quartz crystal microbalance device. Does it hold true for any rigid film that is deposited on a quartz crystal microbalance? A new expression for the mass–frequency relationship of a quartz crystal microbalance device is derived based on equivalent circuit network analysis combined with physical properties of the quartz crystal. Compared to Sauerbrey equation, the proposed expression is derived without applying any approximations. Theoretical analysis is validated with finite-element analysis and experimental test. The results demonstrate that frequency shift of a quartz crystal microbalance is related not only to mass of the deposited addition but also density of the deposited addition. This work is significant to supplement and extend the theory of quartz crystal microbalance.
- 2 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Derivation for Mass–Frequency Relationship of a Quartz Crystal Microbalance Based on an Equivalent Circuit Network Analysis Method
Saurbrey equation has solved frequency dependence on mass change for a rigid film on a quartz crystal microbalance device. Does it hold true for any rigid film that is deposited on a quartz crystal microbalance? A new expression for the mass–frequency relationship of a quartz crystal microbalance device is derived based on equivalent circuit network analysis combined with physical properties of the quartz crystal. Compared to Sauerbrey equation, the proposed expression is derived without applying any approximations. Theoretical analysis is validated with finite-element analysis and experimental test. The results demonstrate that frequency shift of a quartz crystal microbalance is related not only to mass of the deposited addition but also density of the deposited addition. This work is significant to supplement and extend the theory of quartz crystal microbalance.