I.V. Velmakina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
I.V. Velmakina has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Yuliya A. Vokulova
National Research Lobachevsky State University of Nizhny Novgorod
7 shared publications - Evgenii N. Zhulev
Privolzhsky Research Medical University
6 shared publications - Nina A. Yanova
National Research Lobachevsky State University of Nizhny Novgorod
4 shared publications - Olga M. Bragina
Privolzhsky Research Medical University
4 shared publications - Elena Yu. Nikolaeva
Privolzhsky Research Medical University
3 shared publications - Goldobina P.V.
National Research Lobachevsky State University of Nizhny Novgorod, Nizhniy Novgorod, Russian Federation
3 shared publications
Latest Publications
- 30 September 2026
- Published by Belgorod State University in Актуальные проблемы медицины
- Vol. 49 (3)
Обзор современных конструкционных материалов для изготовления эпитезов лица
An analysis was conducted of literature sources spanning five years, focusing on construction materials for facial prostheses. Today, three groups of materials are used, depending on the manufacturing method and the type of prosthesis: medical silicones, acrylic plastics, and photopolymer resins. Each group has a number of drawbacks. Acrylates do not have sufficient elasticity to imitate the texture and consistency of the skin, can cause allergic reactions due to residual monomer, and exhibit polymerization shrinkage. Silicones are prone to rapid aging under the influence of ultraviolet radiation, have low tensile strength, and their porous structure promotes the formation of microbial biofilms and inflammatory processes. Photopolymer resins for 3D printing are still inferior to silicones in terms of strength, service life, and aesthetics. However, the technique of direct 3D printing of facial prostheses is the most promising in terms of cost-effectiveness, high precision, digital data storage, and the ability to quickly produce a new prosthesis without additional medical interventions, which necessitates research into the development of an appropriate structural material.
- 30 September 2026
- Published by Belgorod State University in Актуальные проблемы медицины
- Vol. 49 (3)
Обзор современных конструкционных материалов для изготовления эпитезов лица
An analysis was conducted of literature sources spanning five years, focusing on construction materials for facial prostheses. Today, three groups of materials are used, depending on the manufacturing method and the type of prosthesis: medical silicones, acrylic plastics, and photopolymer resins. Each group has a number of drawbacks. Acrylates do not have sufficient elasticity to imitate the texture and consistency of the skin, can cause allergic reactions due to residual monomer, and exhibit polymerization shrinkage. Silicones are prone to rapid aging under the influence of ultraviolet radiation, have low tensile strength, and their porous structure promotes the formation of microbial biofilms and inflammatory processes. Photopolymer resins for 3D printing are still inferior to silicones in terms of strength, service life, and aesthetics. However, the technique of direct 3D printing of facial prostheses is the most promising in terms of cost-effectiveness, high precision, digital data storage, and the ability to quickly produce a new prosthesis without additional medical interventions, which necessitates research into the development of an appropriate structural material.
- Open Access
- 30 June 2025
- Published by Belgorod State University in Актуальные проблемы медицины
- Vol. 48 (2)
Comparative Characteristics of the Properties of Polymer Materials Used for Manufacturing Temporary Dentures
The study was aimed at providing a comparative characterization of the properties of polymer materials used for manufacturing provisional fixed dentures applying traditional and digital methods. Water absorption and solubility of the materials were assessed. The experimental samples for the study were made of self-hardening cold-polymerized plastic based on polymethylmethacrylate Re-Fine Bright, a chemical-cured bisacrylic composite material Protemp 4, composite blocks made of acrylate polymer for Vita CAD-Temp CAD/CAM systems, and photopolymer resin for the NextDent C&B MFH 3D printer. The study was conducted in accordance with GOST 56924-2016 "Polymer reducing materials". Statistical analysis was performed using the Kraskel-Wallis and Mann-Whitney H-test. It was found that for the Re-Fine Bright material, the average water absorption was 14.94 ± 0.2748 micrograms/mm3, and solubility equaled 0.56 ± 0.1949 micrograms/mm3, for Protemp 4, the average water absorption was 9.259 ± 0.1719 micrograms/mm3, solubility was 0.46 ± 0.1673 micrograms/mm3, for Vita CAD–Temp, the average the value of water absorption equaled 9.649 ± 0.2305 micrograms/mm3, solubility was 0.36 ± 0.1517 micrograms/mm3, for NextDent C&B MFH, the average value of water absorption was 21.69 ± 0.1259 micrograms/mm3, solubility was 0.4 ± 0.2121 micrograms/mm3. The study allows us to conclude that the groups of materials studied are indistinguishable on the basis of the "Solubility" criterion and distinguishable on the basis of the "Water absorption" criterion with a significance level of p < 0.01. There were no statistical differences in the criterion of "Water absorption" between Vita CAD-Temp material, Re-Fine Bright plastic and Protemp 4 material. The water absorption rates for Protemp 4 were significantly lower compared to the ReFine Bright plastic (the median samples differ by 37,4 %, p < 0,0083). The samples made of photopolymer resin for the NextDent C&B MFH 3D printer had the highest water absorption value (the median of the sample was greater than the median of the groups "Protemp 4" by 61.1 %, that of "ReFine Bright" by 37.7 %, and that of "Vita CAD-Temp" by 51.8 %, p < 0.0083).
- 30 June 2025
- Published by Belgorod State University in Актуальные проблемы медицины
- Vol. 48 (2)
Open AccessComparative Characteristics of the Properties of Polymer Materials Used for Manufacturing Temporary Dentures
The study was aimed at providing a comparative characterization of the properties of polymer materials used for manufacturing provisional fixed dentures applying traditional and digital methods. Water absorption and solubility of the materials were assessed. The experimental samples for the study were made of self-hardening cold-polymerized plastic based on polymethylmethacrylate Re-Fine Bright, a chemical-cured bisacrylic composite material Protemp 4, composite blocks made of acrylate polymer for Vita CAD-Temp CAD/CAM systems, and photopolymer resin for the NextDent C&B MFH 3D printer. The study was conducted in accordance with GOST 56924-2016 "Polymer reducing materials". Statistical analysis was performed using the Kraskel-Wallis and Mann-Whitney H-test. It was found that for the Re-Fine Bright material, the average water absorption was 14.94 ± 0.2748 micrograms/mm3, and solubility equaled 0.56 ± 0.1949 micrograms/mm3, for Protemp 4, the average water absorption was 9.259 ± 0.1719 micrograms/mm3, solubility was 0.46 ± 0.1673 micrograms/mm3, for Vita CAD–Temp, the average the value of water absorption equaled 9.649 ± 0.2305 micrograms/mm3, solubility was 0.36 ± 0.1517 micrograms/mm3, for NextDent C&B MFH, the average value of water absorption was 21.69 ± 0.1259 micrograms/mm3, solubility was 0.4 ± 0.2121 micrograms/mm3. The study allows us to conclude that the groups of materials studied are indistinguishable on the basis of the "Solubility" criterion and distinguishable on the basis of the "Water absorption" criterion with a significance level of p < 0.01. There were no statistical differences in the criterion of "Water absorption" between Vita CAD-Temp material, Re-Fine Bright plastic and Protemp 4 material. The water absorption rates for Protemp 4 were significantly lower compared to the ReFine Bright plastic (the median samples differ by 37,4 %, p < 0,0083). The samples made of photopolymer resin for the NextDent C&B MFH 3D printer had the highest water absorption value (the median of the sample was greater than the median of the groups "Protemp 4" by 61.1 %, that of "ReFine Bright" by 37.7 %, and that of "Vita CAD-Temp" by 51.8 %, p < 0.0083).
- Open Access
- 13 April 2025
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 25 (1) , 58-62
Comparative characteristics of the properties of polymer materials used for the manufacture of removable denture bases
Aim – to conduct a comparative characterization of the properties of polymer materials (water absorption and solubility) used for the manufacture of removable denture bases using traditional and digital methods. Material and methods. To conduct the study, experimental samples were made from cold polymerized base resin based on polymethylmethacrylate Vertex Castapress (Vertex Dental, the Netherlands) and photopolymer material for 3D printing Next Dent Base (Next Dent, the Netherlands) in the amount of 5 pieces for each material. The study was conducted in accordance with GOST 31572-2012 “Polymer materials for denture bases”. Statistical analysis was performed using the Mann – Whitney test. Results. For the photopolymer base material for 3D printing, Next Dent Base, the average value of water absorption is 9.857 ± 0.2165 micrograms/mm3, and solubility is 0.22 ± 0.1483 micrograms/mm3. For the basic cold-polymerized resin based on polymethylmethacrylate Vertex Castapress, the average value of water absorption is 13.46 ± 0.1826 micrograms/mm3, solubility is 0.74 ± 0.1342 micrograms/mm3. Conclusions. Criteria of water absorption and solubility are used to assess the ability of basic plastics to withstand the effects of saliva and are indicators of durability and bioinertness of dentures. Next Dent Base, a photopolymer base material for 3D printing, has better water absorption and solubility in comparison with Vertex Castapress cold polymerization resin, which indicates that this material has greater strength and wear resistance (the medians of the samples differ by 32.4% according to the criterion of water absorption, and by 75.0% according to the criterion of solubility).
- 13 April 2025
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 25 (1) , 58-62
Open AccessComparative characteristics of the properties of polymer materials used for the manufacture of removable denture bases
Aim – to conduct a comparative characterization of the properties of polymer materials (water absorption and solubility) used for the manufacture of removable denture bases using traditional and digital methods. Material and methods. To conduct the study, experimental samples were made from cold polymerized base resin based on polymethylmethacrylate Vertex Castapress (Vertex Dental, the Netherlands) and photopolymer material for 3D printing Next Dent Base (Next Dent, the Netherlands) in the amount of 5 pieces for each material. The study was conducted in accordance with GOST 31572-2012 “Polymer materials for denture bases”. Statistical analysis was performed using the Mann – Whitney test. Results. For the photopolymer base material for 3D printing, Next Dent Base, the average value of water absorption is 9.857 ± 0.2165 micrograms/mm3, and solubility is 0.22 ± 0.1483 micrograms/mm3. For the basic cold-polymerized resin based on polymethylmethacrylate Vertex Castapress, the average value of water absorption is 13.46 ± 0.1826 micrograms/mm3, solubility is 0.74 ± 0.1342 micrograms/mm3. Conclusions. Criteria of water absorption and solubility are used to assess the ability of basic plastics to withstand the effects of saliva and are indicators of durability and bioinertness of dentures. Next Dent Base, a photopolymer base material for 3D printing, has better water absorption and solubility in comparison with Vertex Castapress cold polymerization resin, which indicates that this material has greater strength and wear resistance (the medians of the samples differ by 32.4% according to the criterion of water absorption, and by 75.0% according to the criterion of solubility).
- 28 February 2025
- Published by Technomed Holdings LLC in "Medical & Pharmaceutical Journal "Pulse"
ANALYSIS OF THE PROPERTIES OF POLYMER MATERIALS USED FOR THE MANUFACTURE OF REMOVABLE DENTURE BASES
The purpose of the study is to conduct a comparative analysis of the properties of polymeric materials (water absorption and solubility) used for manufacturing removable denture bases using traditional and digital methods. Materials and methods. To conduct the study, experimental samples were made from cold-polymerization base plastic based on polymethyl methacrylate Vertex Castapress (Vertex Dental, Netherlands) and photopolymer material for 3D printing Next Dent Base (Next Dent, Holland) in the amount of 5 pieces for each material. The study was carried out in accordance with GOST 31572-2012 "Polymer materials for denture bases". Statistical analysis was performed using the Mann-Whitney criterion. Results. Based on the obtained data, it was concluded that for the photopolymer base material for 3D printing Next Dent Base, the average water absorption value is 9,857 ± 0,2165 μg/mm3, and solubility is 0,22 ± 0,1483 μg/mm3. For the cold polymerization base plastic based on polymethyl methacrylate Vertex Castapress, the average water absorption value is 13,46 ± 0,1826 μg/mm3, solubility is 0,74 ± 0,1342 μg/mm3. These data allow us to conclude that the water absorption and solubility indicators for both materials are within the permissible GOST norm. However, the photopolymer base material Next Dent Base has significantly lower data compared to the cold polymerization plastic Vertex Castapress (the medians of the samples for the water absorption criterion differ by 32,4%, and for the solubility criterion – by 75,0%).
- 28 February 2025
- Published by Technomed Holdings LLC in "Medical & Pharmaceutical Journal "Pulse"
ANALYSIS OF THE PROPERTIES OF POLYMER MATERIALS USED FOR THE MANUFACTURE OF REMOVABLE DENTURE BASES
The purpose of the study is to conduct a comparative analysis of the properties of polymeric materials (water absorption and solubility) used for manufacturing removable denture bases using traditional and digital methods. Materials and methods. To conduct the study, experimental samples were made from cold-polymerization base plastic based on polymethyl methacrylate Vertex Castapress (Vertex Dental, Netherlands) and photopolymer material for 3D printing Next Dent Base (Next Dent, Holland) in the amount of 5 pieces for each material. The study was carried out in accordance with GOST 31572-2012 "Polymer materials for denture bases". Statistical analysis was performed using the Mann-Whitney criterion. Results. Based on the obtained data, it was concluded that for the photopolymer base material for 3D printing Next Dent Base, the average water absorption value is 9,857 ± 0,2165 μg/mm3, and solubility is 0,22 ± 0,1483 μg/mm3. For the cold polymerization base plastic based on polymethyl methacrylate Vertex Castapress, the average water absorption value is 13,46 ± 0,1826 μg/mm3, solubility is 0,74 ± 0,1342 μg/mm3. These data allow us to conclude that the water absorption and solubility indicators for both materials are within the permissible GOST norm. However, the photopolymer base material Next Dent Base has significantly lower data compared to the cold polymerization plastic Vertex Castapress (the medians of the samples for the water absorption criterion differ by 32,4%, and for the solubility criterion – by 75,0%).
- 28 February 2025
- Published by Technomed Holdings LLC in "Medical & Pharmaceutical Journal "Pulse"
ANALYSIS OF THE PROPERTIES OF POLYMER MATERIALS USED FOR THE MANUFACTURE OF TEMPORARY DENTURES
The purpose of the study is to conduct a comparative characterization of the properties of polymer materials (water absorption and solubility) used for the manufacture of temporary permanent dentures using traditional and digital methods. Materials and methods. For the study, experimental samples were made from self-hardening cold-polymerized plastic based on polymethylmethacrylate Re-Fine Bright, a chemical-cured bisacrylic composite material Protemp 4, composite blocks made of acrylate polymer for Vita CAD-Temp CAD/CAM systems and photopolymer resin for the NextDent C&B MFH 3D printer. The study was conducted in accordance with GOST 56924-2016 "Polymer reducing materials". Statistical analysis was performed using the Kraskel-Wallis and Mann-Whitney H-test. Results. It was found that for the Re-Fine Bright material, the average water absorption is 14,94 ± 0,2748 micrograms/mm3, and solubility is 0,56 ± 0,1949 micrograms/mm3, for Protemp 4, the average water absorption is 9,259 ± 0,1719 micrograms/mm3, solubility is 0,46 ± 0,1673 micrograms/mm3, for Vita CAD–Temp, the average the value of water absorption is 9,649 ± 0,2305 micrograms/mm3, solubility is 0,36 ± 0,1517 micrograms/mm3, for NextDent C&B MFH, the average value of water absorption is 21,69 ± 0,1259 micrograms/mm3, solubility is 0,4 ± 0,2121 micrograms/mm3. Conclusion. We came to the conclusion that the groups of materials studied are indistinguishable on the basis of "Solubility" and distinguishable on the basis of "Water absorption" with a significance level of p < 0,01. There were no statistical differences in the criterion of "Water absorption" between Vita CAD-Temp material, Re-Fine Bright plastic and Protemp 4 material. The water absorption rates for Protemp 4 were significantly lower compared to the ReFine Bright plastic (the median samples differ by 37,4%, p<0,0083). The samples made of photopolymer resin for the NextDent C&B MFH 3D printer had the highest water absorption value (the median of the sample was greater than the median of the groups "Protemp 4" by 61,1%, "ReFine Bright" by 37,7%, "Vita CAD-Temp" by 51,8%, p<0,0083).
- 28 February 2025
- Published by Technomed Holdings LLC in "Medical & Pharmaceutical Journal "Pulse"
ANALYSIS OF THE PROPERTIES OF POLYMER MATERIALS USED FOR THE MANUFACTURE OF TEMPORARY DENTURES
The purpose of the study is to conduct a comparative characterization of the properties of polymer materials (water absorption and solubility) used for the manufacture of temporary permanent dentures using traditional and digital methods. Materials and methods. For the study, experimental samples were made from self-hardening cold-polymerized plastic based on polymethylmethacrylate Re-Fine Bright, a chemical-cured bisacrylic composite material Protemp 4, composite blocks made of acrylate polymer for Vita CAD-Temp CAD/CAM systems and photopolymer resin for the NextDent C&B MFH 3D printer. The study was conducted in accordance with GOST 56924-2016 "Polymer reducing materials". Statistical analysis was performed using the Kraskel-Wallis and Mann-Whitney H-test. Results. It was found that for the Re-Fine Bright material, the average water absorption is 14,94 ± 0,2748 micrograms/mm3, and solubility is 0,56 ± 0,1949 micrograms/mm3, for Protemp 4, the average water absorption is 9,259 ± 0,1719 micrograms/mm3, solubility is 0,46 ± 0,1673 micrograms/mm3, for Vita CAD–Temp, the average the value of water absorption is 9,649 ± 0,2305 micrograms/mm3, solubility is 0,36 ± 0,1517 micrograms/mm3, for NextDent C&B MFH, the average value of water absorption is 21,69 ± 0,1259 micrograms/mm3, solubility is 0,4 ± 0,2121 micrograms/mm3. Conclusion. We came to the conclusion that the groups of materials studied are indistinguishable on the basis of "Solubility" and distinguishable on the basis of "Water absorption" with a significance level of p < 0,01. There were no statistical differences in the criterion of "Water absorption" between Vita CAD-Temp material, Re-Fine Bright plastic and Protemp 4 material. The water absorption rates for Protemp 4 were significantly lower compared to the ReFine Bright plastic (the median samples differ by 37,4%, p<0,0083). The samples made of photopolymer resin for the NextDent C&B MFH 3D printer had the highest water absorption value (the median of the sample was greater than the median of the groups "Protemp 4" by 61,1%, "ReFine Bright" by 37,7%, "Vita CAD-Temp" by 51,8%, p<0,0083).
- Open Access
- 31 December 2023
- Published by The Institute of the Osteopathy and Holistic Medicine in Russian Osteopathic Journal
- No. 4,p. 78-92
Features of the state of occlusion with partial loss of teeth (literature review)
This article provides an overview of literature sources devoted to the peculiarities of the state of occlusion in partial loss of teeth and modern methods of studying occlusive relationships. The clinical picture of partial tooth loss is quite diverse, while changes in occlusive relationships may occur due to the development of deformities of the dentition, the formation of traumatic occlusion, changes in the function of a group of teeth in the presence or absence of antagonists. An increase in the functional load on the preserved teeth entails a structural restructuring of occlusion, which at the initial stages of compensation manifests itself in the form of localized increased erasability of teeth with an increase in the area of occlusal contacts, enamel cracks, and then, as the reserve capabilities of the periodontal decrease, leads to the appearance of mobility and a change in the position of teeth.
- 31 December 2023
- Published by The Institute of the Osteopathy and Holistic Medicine in Russian Osteopathic Journal
- No. 4,p. 78-92
Open AccessFeatures of the state of occlusion with partial loss of teeth (literature review)
This article provides an overview of literature sources devoted to the peculiarities of the state of occlusion in partial loss of teeth and modern methods of studying occlusive relationships. The clinical picture of partial tooth loss is quite diverse, while changes in occlusive relationships may occur due to the development of deformities of the dentition, the formation of traumatic occlusion, changes in the function of a group of teeth in the presence or absence of antagonists. An increase in the functional load on the preserved teeth entails a structural restructuring of occlusion, which at the initial stages of compensation manifests itself in the form of localized increased erasability of teeth with an increase in the area of occlusal contacts, enamel cracks, and then, as the reserve capabilities of the periodontal decrease, leads to the appearance of mobility and a change in the position of teeth.
- Open Access
- 26 December 2023
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 26 (4) , 172-177
Evaluation of the microbiological effectiveness of a hygienic means for the care of facial prostheses
На сегодняшний день нуждаемость пациентов в ортопедическом стоматологическом лечении врожденных и приобретенных дефектов и деформаций челюстно-лицевой области по-прежнему велика. Сегодня для создания эпитезов лица широко используются цифровые технологии, в том числе 3D-печать. Однако до недавнего времени спектр препаратов по уходу за протезами ограничивался только традиционными зубными протезами для полости рта, что побудило к разработке специальных гигиенических средств. Цель — определить адгезию патогенной микрофлоры полости рта к конструкционному материалу, используемому в технологии производства лицевых протезов методом объемной печати, после обработки гигиеническими средствами по их уходу. Оценивали адгезию штаммов микроорганизмов Escherichia coli (ATCC 25982), Staphylococcus aureus (ATCC 6538), Candida albicans (ATCC 10231) и Streptococcus mutans (3003) к образцам конструкционного материала, изготовленным на 3D-принтере без обработки и после 2-минутной обработки очищающей пенкой и спреем. Все изучаемые условно-патогенные микроорганизмы обладали низкой адгезивной активностью по отношению к конструкционному материалу для эпитезов лица, изготовленных методом 3D-печати. После их обработки гигиенической пенкой отмечался нулевой индекс адгезии (p<0,05). При обработке поверхности образцов несмываемым гигиеническим спреем в течение 2 минут адгезия S. mutans к материалу снизилась на 25%, S. aureus — на 8,91%, C. albicans — на 100%, а адгезия E. coli увеличилась на 26,6% в сравнении с образцами без дополнительной обработки. Изученные гигиенические средства в виде пенки и спрея для ухода за эпитезами лица, изготовленными методом 3D-печати, эффективны в отношении условно-патогенных микроорганизмов Escherichia coli, Staphylococcus aureus, Candida albicans и Streptococcus mutans и достоверно снижают индекс их адгезии к поверхности конструкционного материала. To date, the need for patients in orthopedic dental treatment of congenital and acquired defects and deformities of the maxillofacial region is still high. Today, digital technologies are widely used to create facial epithets, including additive 3D printing technologies with new construction materials. However, until recently, the range of prosthetic care products was limited only to traditional dental prostheses for the oral cavity, which prompted the development of special hygiene products. Aim: to determine the adhesion of the pathogenic microflora of the oral cavity to the structural material used in the production technology of facial prostheses by volumetric printing, after treatment with hygienic means for their care. . the evaluation of the microbiological effectiveness of the proposed compositions of hygiene products was carried out in an experiment. The adhesion of strains of microorganisms Escherichia coli, Staphylococcus aureus, Candida albicans, Streptococcus mutans to structural material samples made on a 3D printer by volumetric printing without treatment with cleansing foam and spray and after treatment for two minutes was evaluated. . The results of the study showed that all the studied conditionally pathogenic microorganisms have low adhesive activity in relation to the structural material for facial epitheses made by 3D volumetric printing, and after processing the samples with hygienic foam, a zero adhesion index was noted (p<0.05). When treating the surface of the samples with an indelible hygienic spray for 2 minutes, the adhesion of S. mutans to the material decreased by 25%, S. aureus — by 8.91%, C. albicans — by 100%, and the adhesion of E. coli increased by 26.6% compared to samples without additional treatment. . The studied hygiene products in the form of foam and spray for the care of facial epitheses made by 3D volumetric printing are effective against opportunistic microorganisms Escherichia coli, Staphylococcus aureus, Candida albicans and Streptococcus mutans significantly reduce their adhesion index to the surface of the material.
- 26 December 2023
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 26 (4) , 172-177
Open AccessEvaluation of the microbiological effectiveness of a hygienic means for the care of facial prostheses
На сегодняшний день нуждаемость пациентов в ортопедическом стоматологическом лечении врожденных и приобретенных дефектов и деформаций челюстно-лицевой области по-прежнему велика. Сегодня для создания эпитезов лица широко используются цифровые технологии, в том числе 3D-печать. Однако до недавнего времени спектр препаратов по уходу за протезами ограничивался только традиционными зубными протезами для полости рта, что побудило к разработке специальных гигиенических средств. Цель — определить адгезию патогенной микрофлоры полости рта к конструкционному материалу, используемому в технологии производства лицевых протезов методом объемной печати, после обработки гигиеническими средствами по их уходу. Оценивали адгезию штаммов микроорганизмов Escherichia coli (ATCC 25982), Staphylococcus aureus (ATCC 6538), Candida albicans (ATCC 10231) и Streptococcus mutans (3003) к образцам конструкционного материала, изготовленным на 3D-принтере без обработки и после 2-минутной обработки очищающей пенкой и спреем. Все изучаемые условно-патогенные микроорганизмы обладали низкой адгезивной активностью по отношению к конструкционному материалу для эпитезов лица, изготовленных методом 3D-печати. После их обработки гигиенической пенкой отмечался нулевой индекс адгезии (p<0,05). При обработке поверхности образцов несмываемым гигиеническим спреем в течение 2 минут адгезия S. mutans к материалу снизилась на 25%, S. aureus — на 8,91%, C. albicans — на 100%, а адгезия E. coli увеличилась на 26,6% в сравнении с образцами без дополнительной обработки. Изученные гигиенические средства в виде пенки и спрея для ухода за эпитезами лица, изготовленными методом 3D-печати, эффективны в отношении условно-патогенных микроорганизмов Escherichia coli, Staphylococcus aureus, Candida albicans и Streptococcus mutans и достоверно снижают индекс их адгезии к поверхности конструкционного материала. To date, the need for patients in orthopedic dental treatment of congenital and acquired defects and deformities of the maxillofacial region is still high. Today, digital technologies are widely used to create facial epithets, including additive 3D printing technologies with new construction materials. However, until recently, the range of prosthetic care products was limited only to traditional dental prostheses for the oral cavity, which prompted the development of special hygiene products. Aim: to determine the adhesion of the pathogenic microflora of the oral cavity to the structural material used in the production technology of facial prostheses by volumetric printing, after treatment with hygienic means for their care. . the evaluation of the microbiological effectiveness of the proposed compositions of hygiene products was carried out in an experiment. The adhesion of strains of microorganisms Escherichia coli, Staphylococcus aureus, Candida albicans, Streptococcus mutans to structural material samples made on a 3D printer by volumetric printing without treatment with cleansing foam and spray and after treatment for two minutes was evaluated. . The results of the study showed that all the studied conditionally pathogenic microorganisms have low adhesive activity in relation to the structural material for facial epitheses made by 3D volumetric printing, and after processing the samples with hygienic foam, a zero adhesion index was noted (p<0.05). When treating the surface of the samples with an indelible hygienic spray for 2 minutes, the adhesion of S. mutans to the material decreased by 25%, S. aureus — by 8.91%, C. albicans — by 100%, and the adhesion of E. coli increased by 26.6% compared to samples without additional treatment. . The studied hygiene products in the form of foam and spray for the care of facial epitheses made by 3D volumetric printing are effective against opportunistic microorganisms Escherichia coli, Staphylococcus aureus, Candida albicans and Streptococcus mutans significantly reduce their adhesion index to the surface of the material.
- 24 November 2023
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 102 (6) , 62-67
Modern methods of adhesive fixation of facial epitheses
This review presents an analysis of domestic and foreign literature on the issues of fixation of facial epitheses and combined maxillofacial prostheses, such as the use of craniofacial implants installed in the zygomatic bone, brow arches, orbital walls, mastoid process of the temporal bone with beam or magnetic beam fixation systems. The advantages and disadvantages of such fastening systems are described. The analysis and systematization of available data on medical adhesive compositions that can be used in maxillofacial prosthetics to hold facial epitheses has been carried out. Much attention is paid to the chemical composition of pressure-sensitive adhesives, water-based and silicone-based. Examples of such compositions are given. The physicochemical properties of medical adhesive systems that cause adhesive-cohesive interaction are described. This review presents the results of comparative studies to assess the fixing properties of various adhesives, as well as to study the formation of biofilm on the surfaces of prostheses and skin when using different adhesives.
- 24 November 2023
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 102 (6) , 62-67
Modern methods of adhesive fixation of facial epitheses
This review presents an analysis of domestic and foreign literature on the issues of fixation of facial epitheses and combined maxillofacial prostheses, such as the use of craniofacial implants installed in the zygomatic bone, brow arches, orbital walls, mastoid process of the temporal bone with beam or magnetic beam fixation systems. The advantages and disadvantages of such fastening systems are described. The analysis and systematization of available data on medical adhesive compositions that can be used in maxillofacial prosthetics to hold facial epitheses has been carried out. Much attention is paid to the chemical composition of pressure-sensitive adhesives, water-based and silicone-based. Examples of such compositions are given. The physicochemical properties of medical adhesive systems that cause adhesive-cohesive interaction are described. This review presents the results of comparative studies to assess the fixing properties of various adhesives, as well as to study the formation of biofilm on the surfaces of prostheses and skin when using different adhesives.
- 1 January 2022
- Published by Krasnoyarsk State Medical University in Siberian Medical Review
- Vol. 4
A method for correction of occlusal relationships between dental rows using digital technology
The aim of the research. To develop a technique for correction of occlusal contacts using digital technology. Material and methods. Th is clinical study included 30 (16 male and 14 female) patients aged 33 to 69. Th e patients were divided into three groups. The first group consisted of 10 patients whose orthopaedic treatment was carried out with fi xed prostheses made of the E.max CAD material. Digital modelling of complete anatomical orthopaedic structures was carried out using a virtual articulator. In the patients of the second group, the frames of all-ceramic fixed prostheses were made in the KaVo ARCTICA CAD/CAM system from the ARCTICA ZS-Blank zirconium oxide. Then, the dental technician plastered the jaw models into a fully adjustable articulator Artex CR and applied the facing ceramic mass VM9. For the patients of the third group, the frames of all-ceramic fixed prostheses were made in the KaVo ARCTICA CAD/CAM system from zirconium oxide ARCTICA ZS-Blank. Then, the dental technician plastered the jaw models into a STRATOS 100 medium anatomical articulator and applied a VM9 ceramic facing mass. Occlusion was registered using T-ScanIII. Statistical analysis of the results obtained was carried out in the R soft ware environment using Fisher’s exact test. Results. Regarding the occlusal balance, the technique for manufacturing of fixed prostheses using a virtual articulator is distinguishable from the methods for manufacturing of orthopedic structures using patient-specific and average-value articulators at a significance level of p<0.0167. At this level of significance, there was no statistically signifi cant diff erence between the methods of fixed prostheses manufacturing using patient-specifi c and average-value anatomical articulators. Conclusion. Th e use of digital intraoral scanning technology, modeling of dentures using a virtual articulator and manufacturing of orthopedic structures in CAD/CAM systems makes it possible to obtain non-removable dentures that do not require correction of occlusal contacts at the stage of fi tting in the oral cavity. Th e proposed method for correction of occlusal contacts with digital technology is highly effective.
- 1 January 2022
- Published by Krasnoyarsk State Medical University in Siberian Medical Review
- Vol. 4
A method for correction of occlusal relationships between dental rows using digital technology
The aim of the research. To develop a technique for correction of occlusal contacts using digital technology. Material and methods. Th is clinical study included 30 (16 male and 14 female) patients aged 33 to 69. Th e patients were divided into three groups. The first group consisted of 10 patients whose orthopaedic treatment was carried out with fi xed prostheses made of the E.max CAD material. Digital modelling of complete anatomical orthopaedic structures was carried out using a virtual articulator. In the patients of the second group, the frames of all-ceramic fixed prostheses were made in the KaVo ARCTICA CAD/CAM system from the ARCTICA ZS-Blank zirconium oxide. Then, the dental technician plastered the jaw models into a fully adjustable articulator Artex CR and applied the facing ceramic mass VM9. For the patients of the third group, the frames of all-ceramic fixed prostheses were made in the KaVo ARCTICA CAD/CAM system from zirconium oxide ARCTICA ZS-Blank. Then, the dental technician plastered the jaw models into a STRATOS 100 medium anatomical articulator and applied a VM9 ceramic facing mass. Occlusion was registered using T-ScanIII. Statistical analysis of the results obtained was carried out in the R soft ware environment using Fisher’s exact test. Results. Regarding the occlusal balance, the technique for manufacturing of fixed prostheses using a virtual articulator is distinguishable from the methods for manufacturing of orthopedic structures using patient-specific and average-value articulators at a significance level of p<0.0167. At this level of significance, there was no statistically signifi cant diff erence between the methods of fixed prostheses manufacturing using patient-specifi c and average-value anatomical articulators. Conclusion. Th e use of digital intraoral scanning technology, modeling of dentures using a virtual articulator and manufacturing of orthopedic structures in CAD/CAM systems makes it possible to obtain non-removable dentures that do not require correction of occlusal contacts at the stage of fi tting in the oral cavity. Th e proposed method for correction of occlusal contacts with digital technology is highly effective.