  • ANALYSIS OF THE PROPERTIES OF POLYMER MATERIALS USED FOR THE MANUFACTURE OF REMOVABLE DENTURE BASES

    by Zhulev E.N., Vokulova Yu.A., Velmakina I.V., Yanova N.A., Bragina O.M., Goldobina P.V., Galkina E.S.

    The purpose of the study is to conduct a comparative analysis of the properties of polymeric materials (water absorption and solubility) used for manufacturing removable denture bases using traditional and digital methods. Materials and methods. To conduct the study, experimental samples were made from cold-polymerization base plastic based on polymethyl methacrylate Vertex Castapress (Vertex Dental, Netherlands) and photopolymer material for 3D printing Next Dent Base (Next Dent, Holland) in the amount of 5 pieces for each material. The study was carried out in accordance with GOST 31572-2012 "Polymer materials for denture bases". Statistical analysis was performed using the Mann-Whitney criterion. Results. Based on the obtained data, it was concluded that for the photopolymer base material for 3D printing Next Dent Base, the average water absorption value is 9,857 ± 0,2165 μg/mm3, and solubility is 0,22 ± 0,1483 μg/mm3. For the cold polymerization base plastic based on polymethyl methacrylate Vertex Castapress, the average water absorption value is 13,46 ± 0,1826 μg/mm3, solubility is 0,74 ± 0,1342 μg/mm3. These data allow us to conclude that the water absorption and solubility indicators for both materials are within the permissible GOST norm. However, the photopolymer base material Next Dent Base has significantly lower data compared to the cold polymerization plastic Vertex Castapress (the medians of the samples for the water absorption criterion differ by 32,4%, and for the solubility criterion – by 75,0%).

  • ANALYSIS OF THE PROPERTIES OF POLYMER MATERIALS USED FOR THE MANUFACTURE OF TEMPORARY DENTURES

    by Vokulova Yu.A., Nikolaeva E.YU., Velmakina I.V., Yanova N.A., Plishkina A.A., Goldobina P.V., Galkina E.S.

    The purpose of the study is to conduct a comparative characterization of the properties of polymer materials (water absorption and solubility) used for the manufacture of temporary permanent dentures using traditional and digital methods. Materials and methods. For the study, experimental samples were made from self-hardening cold-polymerized plastic based on polymethylmethacrylate Re-Fine Bright, a chemical-cured bisacrylic composite material Protemp 4, composite blocks made of acrylate polymer for Vita CAD-Temp CAD/CAM systems and photopolymer resin for the NextDent C&B MFH 3D printer. The study was conducted in accordance with GOST 56924-2016 "Polymer reducing materials". Statistical analysis was performed using the Kraskel-Wallis and Mann-Whitney H-test. Results. It was found that for the Re-Fine Bright material, the average water absorption is 14,94 ± 0,2748 micrograms/mm3, and solubility is 0,56 ± 0,1949 micrograms/mm3, for Protemp 4, the average water absorption is 9,259 ± 0,1719 micrograms/mm3, solubility is 0,46 ± 0,1673 micrograms/mm3, for Vita CAD–Temp, the average the value of water absorption is 9,649 ± 0,2305 micrograms/mm3, solubility is 0,36 ± 0,1517 micrograms/mm3, for NextDent C&B MFH, the average value of water absorption is 21,69 ± 0,1259 micrograms/mm3, solubility is 0,4 ± 0,2121 micrograms/mm3. Conclusion. We came to the conclusion that the groups of materials studied are indistinguishable on the basis of "Solubility" and distinguishable on the basis of "Water absorption" with a significance level of p < 0,01. There were no statistical differences in the criterion of "Water absorption" between Vita CAD-Temp material, Re-Fine Bright plastic and Protemp 4 material. The water absorption rates for Protemp 4 were significantly lower compared to the ReFine Bright plastic (the median samples differ by 37,4%, p<0,0083). The samples made of photopolymer resin for the NextDent C&B MFH 3D printer had the highest water absorption value (the median of the sample was greater than the median of the groups "Protemp 4" by 61,1%, "ReFine Bright" by 37,7%, "Vita CAD-Temp" by 51,8%, p<0,0083).

  • Application of two-dimensional X-ray studies in asymmetric deformations of the maxillofacial region

    by I.O. Ayupova, A.YU. Makhota, N.V. Popov, M.A. Davidyuk, O.N. Ayupov, N.V. Tiunova, N.A. Yanova, P.V. Goldobina, V.G. Vladimirova

    Background. Transversal anomalies of the maxillofacial region (MFR) of a person are common and significantly affect its aesthetics and functions. One of the most valuable methods of studying MFR is X-ray. Currently, three-dimensional analysis methods are becoming more widespread, but two-dimensional cephalograms have a number of advantages, such as: low radiation dose and a variety of cephalometric diagnostic methods that have proven their effectiveness in analyzing vertical and horizontal malocclusion. Therefore, the question arises about the diagnostic value of these methods for assessing transversal anomalies of the maxillofacial region, which makes this work relevant. Objective. The purpose of the study is to review the available literature on the possibilities of using two-dimensional X-ray examinations for asymmetric deformations of the CR. Material and methods. An analysis of 85 scientific publications was carried out: 36 domestic and 49 foreign in the information and scientific systems PubMed, Google Scholar, Web of Science, e-library, describing methods for diagnosing transversal anomalies in dental practice. The search was carried out by keywords: asymmetric anomalies, cephalometric analysis, orthodontics, transversal deformities of the MFR, cephalometry, maxillofacial anomalies, direct TRG, lateral TRG, craniometry, CBCT. The last selection of sources was completed in August 2024. Results. The analysis of literary sources was carried out, the exclusion criteria of which were: inconsistency with the subject of the study, lack of a full-text version of the study, completeness of the information presented. After the inclusion of studies that did not meet the sampling criteria, the team of authors performed appropriate illustrations to the described methods of cephalometric analysis. A review of the bibliographic data on obtaining cephalometric parameters on two-dimensional X-ray images revealed a limitation in the possibility of their application for practical purposes due to the fragmentary nature of these studies. Conclusion. The conclusion is formulated about the need for further study and improvement of available techniques for patients with asymmetric deformities of the maxillofacial region.