Patryk Dzierzawski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Patryk Dzierzawski has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Schumann
Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, Germany
2 shared publications Benedikt Fischer
Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, Germany
1 shared publicationBernd Flamm
Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, Germany
1 shared publicationChristin Wenzel
Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, Germany
1 shared publicationHartmut Breger
Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, Germany
1 shared publicationJakob Oswalt
University of Freiburg
1 shared publication
Latest Publications
- 10 July 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 240 (8) , 847-860
Design and development of a novel media-separated valve for flow-controlled expiration during mechanical ventilation
Mechanical ventilation has become a central therapeutic means in modern medicine. However, mechanical ventilation carries the risk of ventilator-induced lung injury. Our group introduced flow-controlled expiration (FLEX) as an additional approach to effective, lung-protective mechanical ventilation. By gradually reducing the pneumatic resistance, FLEX controls expiratory flow toward a user-set constant target, replacing the exponential flow-time profile of a conventional expiration. Primarily developed to demonstrate the physiological concept, the initial FLEX-system prototype did not provide closed-loop flow regulation and full media separation. These considerations motivated the development of a more advanced system that precisely adjusts pneumatic resistance to achieve rapid closed-loop control of the desired expiratory flow rates. We validated our system through multiple tests using physical lung surrogates. We could effectively control the expiratory flow with two ventilation devices. We thereby demonstrated that the system attenuated high initial expiratory peak flow and guided expiratory flow toward user-selected target values in physical respiratory-system models under a range of physiological and non-physiological conditions. Our system features an innovative valve that enables accurate flow regulation, facilitates easy valve replacement, and ensures complete separation of the respiratory gas space from the ambient environment, thereby enhancing safety and reliability. Moreover, the microcontroller implementation creates a self-contained system, making it well-suited for potential clinical applications.
- 10 July 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 240 (8) , 847-860
Design and development of a novel media-separated valve for flow-controlled expiration during mechanical ventilation
Mechanical ventilation has become a central therapeutic means in modern medicine. However, mechanical ventilation carries the risk of ventilator-induced lung injury. Our group introduced flow-controlled expiration (FLEX) as an additional approach to effective, lung-protective mechanical ventilation. By gradually reducing the pneumatic resistance, FLEX controls expiratory flow toward a user-set constant target, replacing the exponential flow-time profile of a conventional expiration. Primarily developed to demonstrate the physiological concept, the initial FLEX-system prototype did not provide closed-loop flow regulation and full media separation. These considerations motivated the development of a more advanced system that precisely adjusts pneumatic resistance to achieve rapid closed-loop control of the desired expiratory flow rates. We validated our system through multiple tests using physical lung surrogates. We could effectively control the expiratory flow with two ventilation devices. We thereby demonstrated that the system attenuated high initial expiratory peak flow and guided expiratory flow toward user-selected target values in physical respiratory-system models under a range of physiological and non-physiological conditions. Our system features an innovative valve that enables accurate flow regulation, facilitates easy valve replacement, and ensures complete separation of the respiratory gas space from the ambient environment, thereby enhancing safety and reliability. Moreover, the microcontroller implementation creates a self-contained system, making it well-suited for potential clinical applications.
- 26 September 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (9) , 095004
Intratidal compliance of the lung and the total respiratory system
Objective. The worldwide rising quantity of surgeries and the corresponding need of mechanical ventilation means a rising number of patients are at risk of suffering from post-operative pulmonary complications. To prevent this risk, individual mechanics of the lung should be considered when setting the parameters of mechanical ventilation. Intratidal compliance analysis based on transpulmonal pressure would provide an estimate for individual lung mechanics. The downside of such measure, however, is its invasiveness. Accurate measurement requires recording of the esophageal pressure as surrogate for the actual pleural pressure. Measuring pressure at the airway opening is considerably easier, but the resulting mechanics of the respiratory system may not represent the actual lung mechanics in a straightforward fashion. Approach. In order to evaluate if the mechanics of the lungs are represented by analysis of the mechanics of the respiratory system we determined intratidal dynamic compliance-volume profiles of both in 23 lung-healthy mechanically ventilated patients undergoing elective surgery. We also compared the accuracy of the compliance profiles resulting from analysis of the total breath with those resulting from the analysis of inspiration data only. Main results. When the whole breath was analyzed 54.3%, and with only inspiration data 69.6%, of compliance profiles of the respiratory system matched those of the lung. With both approaches profiles of the lung and the respiratory system matched or deviated by only one neighboring step (75% whole breath, 91.3% inspiration only), and never contradicted each other. Significance. Compliance profiles calculated from volume and pressure data of the respiratory system are an adequate surrogate for the compliance profiles of the lungs of lung-healthy patients. Therefore, invasive assessment of esophageal pressure for achievement of intrapleural pressure is unnecessary. The compliance profiles based on only inspiratory data appear more sensitive for indicating intratidal derecruitment than those based on data of the whole breath.
- 26 September 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (9) , 095004
Intratidal compliance of the lung and the total respiratory system
Objective. The worldwide rising quantity of surgeries and the corresponding need of mechanical ventilation means a rising number of patients are at risk of suffering from post-operative pulmonary complications. To prevent this risk, individual mechanics of the lung should be considered when setting the parameters of mechanical ventilation. Intratidal compliance analysis based on transpulmonal pressure would provide an estimate for individual lung mechanics. The downside of such measure, however, is its invasiveness. Accurate measurement requires recording of the esophageal pressure as surrogate for the actual pleural pressure. Measuring pressure at the airway opening is considerably easier, but the resulting mechanics of the respiratory system may not represent the actual lung mechanics in a straightforward fashion. Approach. In order to evaluate if the mechanics of the lungs are represented by analysis of the mechanics of the respiratory system we determined intratidal dynamic compliance-volume profiles of both in 23 lung-healthy mechanically ventilated patients undergoing elective surgery. We also compared the accuracy of the compliance profiles resulting from analysis of the total breath with those resulting from the analysis of inspiration data only. Main results. When the whole breath was analyzed 54.3%, and with only inspiration data 69.6%, of compliance profiles of the respiratory system matched those of the lung. With both approaches profiles of the lung and the respiratory system matched or deviated by only one neighboring step (75% whole breath, 91.3% inspiration only), and never contradicted each other. Significance. Compliance profiles calculated from volume and pressure data of the respiratory system are an adequate surrogate for the compliance profiles of the lungs of lung-healthy patients. Therefore, invasive assessment of esophageal pressure for achievement of intrapleural pressure is unnecessary. The compliance profiles based on only inspiratory data appear more sensitive for indicating intratidal derecruitment than those based on data of the whole breath.