Herman Tawil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Herman Tawil has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chee Ghuan Tan
Department of Civil Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
2 shared publications - Fadzli Mohamed Nazri
Universiti Sains Malaysia
2 shared publications - Nor Hafizah Ramli Sulong
Group of Sustainable Engineered Construction Materials, School of Civil & Environmental Engineering, Faculty of Engineering, Queensland University of Technology, 2 George St., Brisbane, QLD 4000, Australia
2 shared publications - Ahmed El-Shafie
National Water and Energy Center, United Arab Emirates University, Al Ain, United Arab Emirates
1 shared publication - Mohd Fazaulnizam Shamsudin
Department of Civil Engineering, Faculty of Engineering, Federal Territory of Kuala Lumpur, Universiti Malaya, Kuala Lumpur, Malaysia
1 shared publication - Muhammad M. Sherif
Department of Civil, Construction and Environmental Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
1 shared publication
Latest Publications
- Open Access
Optimization of Shear Resistance in Precast Concrete Sandwich Wall Panels Using an S-Type Shear Connector
Precast concrete sandwich wall panels (PCSPs) are popular for building exteriors due to their high thermal efficiency, composite performance, and low manufacturing and maintenance costs. Researchers have investigated the possibility of reducing the panel thickness while maintaining the cladding components’ thermal efficiency and strength to further improve efficiency and to reduce material consumption. However, limited research has been conducted on the shear bonding of steel plates, which is critical to ensuring durability and energy efficiency. This study investigated the shear behaviour of PCSPs with an S-type shear connector (SSC) through nine push-off tests and non-linear finite element modelling using Abaqus. Parametric studies were carried out to investigate the influence of the geometric properties of the SSC, the yield strength of the steel and the insulation thickness. The results suggest that the maximum secant stiffness for SSCs was achieved at a width of 101.4 mm and a thickness of 2 mm. Therefore, it is recommended that the width of the SSCs be limited to this value or less. Furthermore, the study found that increasing the yield strength of the steel beyond a thickness of 2 mm and a width of 101.4 mm did not improve the results and had a negative impact on the secant stiffness of the SSCs.
Open AccessOptimization of Shear Resistance in Precast Concrete Sandwich Wall Panels Using an S-Type Shear Connector
Precast concrete sandwich wall panels (PCSPs) are popular for building exteriors due to their high thermal efficiency, composite performance, and low manufacturing and maintenance costs. Researchers have investigated the possibility of reducing the panel thickness while maintaining the cladding components’ thermal efficiency and strength to further improve efficiency and to reduce material consumption. However, limited research has been conducted on the shear bonding of steel plates, which is critical to ensuring durability and energy efficiency. This study investigated the shear behaviour of PCSPs with an S-type shear connector (SSC) through nine push-off tests and non-linear finite element modelling using Abaqus. Parametric studies were carried out to investigate the influence of the geometric properties of the SSC, the yield strength of the steel and the insulation thickness. The results suggest that the maximum secant stiffness for SSCs was achieved at a width of 101.4 mm and a thickness of 2 mm. Therefore, it is recommended that the width of the SSCs be limited to this value or less. Furthermore, the study found that increasing the yield strength of the steel beyond a thickness of 2 mm and a width of 101.4 mm did not improve the results and had a negative impact on the secant stiffness of the SSCs.
- Open Access
Mechanical and Thermal Properties of Composite Precast Concrete Sandwich Panels: A Review
Precast concrete sandwich panels (PCSPs) are utilized for the external cladding of structures (i.e., residential, and commercial) due to their high thermal efficiency and adequate composite action that resist applied loads. PCSPs are composed of an insulating layer with high thermal resistance that is mechanically connected to the concrete. In the recent decades, PCSPs have been a viable alternative for the fast deployment of structures due to the low fabrication and maintenance cost. Furthermore, the construction of light and thin concrete wythes that can transfer and resist shear loads has been achieved with the utilization of high-performance cementitious composites. As a result, engineers prefer PCSPs for building construction. PCSP design and use have been examined to guarantee that a building is energy efficient, has structural integrity, is sustainable, is comfortable, and is safe. Hence, this paper reviews the expanding knowledge regarding the current development of the mechanical and thermal properties of the PCSPs components; subsequently, future potential research directions are suggested.
Open AccessMechanical and Thermal Properties of Composite Precast Concrete Sandwich Panels: A Review
Precast concrete sandwich panels (PCSPs) are utilized for the external cladding of structures (i.e., residential, and commercial) due to their high thermal efficiency and adequate composite action that resist applied loads. PCSPs are composed of an insulating layer with high thermal resistance that is mechanically connected to the concrete. In the recent decades, PCSPs have been a viable alternative for the fast deployment of structures due to the low fabrication and maintenance cost. Furthermore, the construction of light and thin concrete wythes that can transfer and resist shear loads has been achieved with the utilization of high-performance cementitious composites. As a result, engineers prefer PCSPs for building construction. PCSP design and use have been examined to guarantee that a building is energy efficient, has structural integrity, is sustainable, is comfortable, and is safe. Hence, this paper reviews the expanding knowledge regarding the current development of the mechanical and thermal properties of the PCSPs components; subsequently, future potential research directions are suggested.