Peter McClure
Research Subjects
Research Interests
Peter McClure has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dylan Richmond
Department of Materials Science and Engineering, State University of New York at Binghamton, Binghamton, NY, USA
1 shared publication James Wilcox
Advanced Process Laboratory, Universal Instruments Corporation, Conklin, NY, USA
1 shared publication- Mark. D. Poliks
Binghamton University
1 shared publication Yujia Wang
Materials Science and Engineering, Cornell University, Ithaca, USA
1 shared publication
Latest Publications
- 26 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 13 (2) , 171-176
Novel TIM Evaluation Method With in Situ Electrical Monitoring
Thermal interface materials (TIMs) transfer heat between two surfaces in electronic assemblies. Specifically, a TIM 2 is a TIM used to transfer heat from a component’s lid to a heat sink. During use, TIM 2s experience thermal aging and mechanical stress (caused by board/component/heat sink expansion mismatches and warpage during heating/cooling). Understanding the response of TIMs to these stresses is critical for understanding TIM and product reliability. However, the responses of TIMs are complex and difficult to predict or model. TIMs are often polymeric materials heavily loaded with thermally conductive fillers and have time, temperature, and rate-dependent properties. Therefore, experimental studies are needed to address TIM reliability. However, monitoring TIM stability or performance while in situ is difficult. Electrical capacitance has been used to monitor the stability of dielectric TIM in situ, allowing for monitoring TIM stability and, indirectly, the TIM thermal performance. But electrically conductive TIMs cannot be used with capacitance measurements, so a new technique is needed. Monitoring a conductive TIM’s electrical resistance could give insight into a TIM’s stability, as thermal and electrical resistance are both affected by a TIM’s contact with surfaces, thickness, and area. This study examines four electrically conductive graphite pad TIMs on a test board, representing a large printed circuit board with a large shared heat sink, in an accelerated thermal cycle from 0 to 100°C. The electrical resistance of the TIMs was monitored in situ, and after testing post mortem failure analysis of the TIMs was done. The efficacy of electrical resistance monitoring for evaluating TIM stability was examined, and correlations with failure analysis results were made. Electrical resistance monitoring provided insight into the TIMs’ stability, failure time, and extent of failure.
- 26 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 13 (2) , 171-176
Novel TIM Evaluation Method With in Situ Electrical Monitoring
Thermal interface materials (TIMs) transfer heat between two surfaces in electronic assemblies. Specifically, a TIM 2 is a TIM used to transfer heat from a component’s lid to a heat sink. During use, TIM 2s experience thermal aging and mechanical stress (caused by board/component/heat sink expansion mismatches and warpage during heating/cooling). Understanding the response of TIMs to these stresses is critical for understanding TIM and product reliability. However, the responses of TIMs are complex and difficult to predict or model. TIMs are often polymeric materials heavily loaded with thermally conductive fillers and have time, temperature, and rate-dependent properties. Therefore, experimental studies are needed to address TIM reliability. However, monitoring TIM stability or performance while in situ is difficult. Electrical capacitance has been used to monitor the stability of dielectric TIM in situ, allowing for monitoring TIM stability and, indirectly, the TIM thermal performance. But electrically conductive TIMs cannot be used with capacitance measurements, so a new technique is needed. Monitoring a conductive TIM’s electrical resistance could give insight into a TIM’s stability, as thermal and electrical resistance are both affected by a TIM’s contact with surfaces, thickness, and area. This study examines four electrically conductive graphite pad TIMs on a test board, representing a large printed circuit board with a large shared heat sink, in an accelerated thermal cycle from 0 to 100°C. The electrical resistance of the TIMs was monitored in situ, and after testing post mortem failure analysis of the TIMs was done. The efficacy of electrical resistance monitoring for evaluating TIM stability was examined, and correlations with failure analysis results were made. Electrical resistance monitoring provided insight into the TIMs’ stability, failure time, and extent of failure.
- 14 September 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 33 (29) , 22810-22820
Indium thermal interface material microstructure as a function of thermal history and bonding metallization
- 14 September 2022
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 33 (29) , 22810-22820
Indium thermal interface material microstructure as a function of thermal history and bonding metallization