MHMuhammad Hafizh

Muhammad Hafizh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Muhammad Hafizh has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Performance Comparison of Hybrid and Standalone Piezoelectric Energy Harvesters Under Vortex-Induced Vibrations

    by Issam Bahadur, Hassen Ouakad, El Manaa Barhoumi, Asan Muthalif, Muhammad Hafizh, Jamil Renno, Mohammad Paurobally

    This study investigates the effect of incorporating an electromagnetic harvester inside the bluff body of a 2-DoF hybrid harvester in comparison to a standalone piezoelectric harvester for various external loads. The harvester is excited through a vortex-induced vibration owing to the resultant wake vortices created behind the bluff body. The coupled dynamics of the two harvester components are modeled, and numerical simulations are conducted to evaluate the system’s performance under varying electrical loads. Numerical results show that at high, optimum electrical load, the standalone piezoelectric harvester outperforms the hybrid harvester. Nevertheless, for small electrical loads, the results show that the hybrid harvester outperforms the standalone PZT harvester by up to 18% in peak power output, while reducing the bandwidth by approximately 10% compared to the standalone piezoelectric harvester. Optimal spring stiffness values were identified, with the hybrid harvester achieving its maximum output power at a spring stiffness of 83.56 N/m. These findings underscore the need for careful design considerations, as the hybrid harvester may not achieve enhanced power output and bandwidth under higher electrical loads.


  • Open Access

    Comparative Study of a 2-DoF Hybrid Piezoelectric-Electromagnetic Energy Harvester and a Standalone Piezoelectric Harvester

    by Issam M. Bahadur, Hassen Ouakad, El Manaa Barhoumi, Asan Muthalif, Muhammad Hafizh, Jamil Renno, Mohammad Paurobally

    This study investigates the effect of incorporating an electromagnetic harvester inside the bluff body of a 2-DoF hybrid harvester in comparison to a standalone piezoelectric harvester for various external loads. The design consists of an electromagnetic harvester embedded inside a cylindrical bluff body, which is attached to the free end of a composite PZT cantilever beam. The harvester is excited through a vortex-induced vibration owing to the resultant wake vortices created behind the bluff body. The coupled equations of motion of the harvester are derived using the lumped-mass equivalent representation and Lagrange formulation. Numerical results show that at high operating flow speed and large electrical load, the standalone piezoelectric harvester outperforms the hybrid harvester. Nevertheless, for small electrical loads and at low-speed flow, the hybrid harvester outperforms the standalone ones for a wider range of the flow speed. In these operating conditions, numerical simulations also showed that an optimum spring stiffness of the electromagnetic harvester exists at a certain flow speed for a maximized harvested output power. In general, such hybrid energy harvester showed to be more effective at low-speed fluid flow and small electrical loads.


  • Rotational Vibration-Based Piezoelectric Energy Harvesting with Bandwidth Enhancement Through Magnetic Oscillators

    by Muhammad Hafizh, Abdelrahman Ali, Sakib Mahmud, Mohamed A. Ayari, Asan G. A. Muthalif

  • Open Access

    Evaluation of Bruising Susceptibility and Response of Pears under Impact Loading through Finite Element Analysis

    by Muhammad Hafizh, Asma Mecheter, Faris Tarlochan, Pankaj B. Pathare

    Mechanical damage and bruising of fruit is a critical problem in the food industry. Minimizing brusing and damage can be achieved by designing energy-absorbing structures and packaging systems in order to ensure the long-term quality of fresh produce. The aim of this study is to investigate the response and bruise susceptibility of pears under impact loading conditions through finite element analysis (FEA) methods. In this paper, three impact heights (0.25 m, 0.5 m, and 1.0 m), four impact material surfaces (poplar wood, rubber, cardboard, and acrylonitrile butadiene styrene (ABS) plastic), two packaging sizes (standard 0.22″ and sandwich lattice 2.1″), and three impact design structures (rigid, corrugated, and honeycomb) are considered. Based on mesh sensitivity analysis, a mesh element of 1.5 mm was adopted for all simulations, assuring the accuracy of results and considering the trade-off between mesh size and computational time. The response surface analysis approach was utilized in order to develop predictive empirical models related to pear bruising. Results revealed that the rubber-based impact platform yielded minimal bruise susceptibility at all heights, while standard-sized corrugated cardboard performed best at a height of 0.25 m. Furthermore, single, double, and triple layers of packaging cardboard were tested. We observed that adding a second soft layer of corrugated cardboard reduced the stress on the pear by around 33%. However, adding a third layer only reduced stress by 5%. The 3D-printed honeycomb ABS has potential as protective packaging but would require further investigations and parameter optimization. Stacking multiple layers of cardboard on top of each other is a cost-effective solution that could improve damping and, therefore, ensure good quality and increase the shelf life of the fresh produce. This study will help decision-makers select the optimal energy-absorbing material for cushioning and packaging designs in order to improve the handling and post-harvesting logistics of fresh produce.


  • Design and efficiency evaluation of a new wearable device for multi-degree suppression of hand pathological tremor

    by Mo’aTh Yousef, Muhammad Hafizh, Sadok Sassi, Asan G.A Muthalif

    Sufferers of onset upper limb tremors find difficulty performing daily tasks due to rapid involuntary movements. Traditional treatments being offered help alleviate symptoms but are costly and can be invasive. Wearable technology advancements have introduced the applications of tremor suppression devices. A low-cost wearable bracelet was developed for sufferers of Parkinson’s disease and essential tremors to target rest and active tremors. Real-life measured tremor spectrums were used as input signals to design a dynamic vibration absorber. An innovative multiple-slot design allowed for multiple frequency suppression in the range of 3–8 Hz. A finite element analysis simulated the response of the upper limb with and without the bracelet. The results showed an overall suppression decreased tremors by up to 68% and targeted suppression decreased tremors by up to 98.2%.


  • Open Access

    Design and Performance Evaluation of a Novel Spiral Head-Stem Trunnion for Hip Implants Using Finite Element Analysis

    by Mohiuddin Soliman, Muhammad E. H. Chowdhury, Mohammad Tariqul Islam, Farayi Musharavati, Sakib Mahmud, Muhammad Hafizh, Mohamed Arselene Ayari, Amith Khandakar, Mohammad Kaosar Alam, Erfan Zal Nezhad

    With an expectation of an increased number of revision surgeries and patients receiving orthopedic implants in the coming years, the focus of joint replacement research needs to be on improving the mechanical properties of implants. Head-stem trunnion fixation provides superior load support and implant stability. Fretting wear is formed at the trunnion because of the dynamic load activities of patients, and this eventually causes the total hip implant system to fail. To optimize the design, multiple experiments with various trunnion geometries have been performed by researchers to examine the wear rate and associated mechanical performance characteristics of the existing head-stem trunnion. The objective of this work is to quantify and evaluate the performance parameters of smooth and novel spiral head-stem trunnion types under dynamic loading situations. This study proposes a finite element method for estimating head-stem trunnion performance characteristics, namely contact pressure and sliding distance, for both trunnion types under walking and jogging dynamic loading conditions. The wear rate for both trunnion types was computed using the Archard wear model for a standard number of gait cycles. The experimental results indicated that the spiral trunnion with a uniform contact pressure distribution achieved more fixation than the smooth trunnion. However, the average contact pressure distribution was nearly the same for both trunnion types. The maximum and average sliding distances were both shorter for the spiral trunnion; hence, the summed sliding distance was approximately 10% shorter for spiral trunnions than that of the smooth trunnion over a complete gait cycle. Owing to a lower sliding ability, hip implants with spiral trunnions achieved more stability than those with smooth trunnions. The anticipated wear rate for spiral trunnions was 0.039 mm3, which was approximately 10% lower than the smooth trunnion wear rate of 0.048 mm3 per million loading cycles. The spiral trunnion achieved superior fixation stability with a shorter sliding distance and a lower wear rate than the smooth trunnion; therefore, the spiral trunnion can be recommended for future hip implant systems.


  • Open Access

    A vortex-induced vibration-based self-tunable airfoil-shaped piezoelectric energy harvester for remote sensing applications in water

    by Muhammad Hafizh, Asan G.A. Muthalif, Jamil Renno, M.R. Paurobally, Mohamed Sultan Mohamed Ali


  • Open Access

    Surface Acoustic Wave (SAW) Sensors for Hip Implant: A Numerical and Computational Feasibility Investigation Using Finite Element Methods

    by Muhammad Hafizh, Mohiuddin Soliman, Yazan Qiblawey, Muhammad E. H. Chowdhury, Mohammad Tariqul Islam, Farayi Musharavati, Sakib Mahmud, Amith Khandakar, Mohammad Nabil, Erfan Zal Nezhad

    In this paper, a surface acoustic wave (SAW) sensor for hip implant geometry was proposed for the application of total hip replacement. A two-port SAW device was numerically investigated for implementation with an operating frequency of 872 MHz that can be used in more common radio frequency interrogator units. A finite element analysis of the device was developed for a lithium niobate (LiNBO3) substrate with a Rayleigh velocity of 3488 m/s on COMSOL Multiphysics. The Multiphysics loading and frequency results highlighted a good uniformity with numerical results. Afterwards, a hip implant geometry was developed. The SAW sensor was mounted at two locations on the implant corresponding to two regions along the shaft of the femur bone. Three discrete conditions were studied for the feasibility of the implant with upper- and lower-body loading. The loading simulations highlighted that the stresses experienced do not exceed the yield strengths. The voltage output results indicated that the SAW sensor can be implanted in the hip implant for hip implant-loosening detection applications.