Sumin Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sumin Kim has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Jang-Ung Park
Department of Materials Science and Engineering, Yonsei University
12 shared publications - Enji Kim
Department of Materials Science and Engineering, Yonsei University, Seoul, Republic of Korea
8 shared publications - Hunkyu Seo
Department of Materials Science and Engineering, Yonsei University College of Engineering, Seoul 03722, Republic of Korea
6 shared publications - Jakyoung Lee
Department of Materials Science and Engineering, Yonsei University College of Engineering, Seoul 03722, Republic of Korea
6 shared publications - Wonjung Park
Department of Materials Science and Engineering, Yonsei University, Seoul, Republic of Korea
6 shared publications - Hayoung Song
Department of Materials Science and Engineering, Yonsei University
5 shared publications
Latest Publications
- Open Access
- 22 July 2026
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 123 (30)
Wireless, skin-attachable patch with 3D liquid metal electrodes for vagus nerve stimulation in depression
Current nonsurgical vagus nerve stimulation (VNS) approaches often suffer from broad current spread, high electrode-skin impedance, and unintended stimulation of surrounding tissues, which can reduce efficacy and cause side effects. Here, we present a wirelessly operable, skin-attachable VNS patch with three-dimensional liquid-metal electrodes that mimic the low modulus of biological tissues, developed as a minimally invasive platform for investigating the biological mechanisms underlying VNS in a mouse model of depression. The soft, low-modulus three-dimensional liquid metal electrodes gently penetrate the skin, bypass the stratum corneum, and improve electrode–tissue coupling while minimizing tissue damage compared with conventional planar or rigid electrodes. To comprehensively assess therapeutic effects, we conducted behavioral tests, neural probe-based brain signal analysis, dendritic spine density measurements, and blood and inguinal lymph node profiling in depression model mice. VNS increased plasma serotonin levels and increased dendritic spine density, indicating improved neuroplasticity. Corticosterone-induced depressive mice exhibited elevated CD4+ and B220+ cells, which normalized with VNS. These results establish an animal-level proof-of-concept that minimally invasive VNS can engage key neural and immunological pathways relevant to depression, providing a foundation for future neuromodulation strategies.
- 22 July 2026
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 123 (30)
Open AccessWireless, skin-attachable patch with 3D liquid metal electrodes for vagus nerve stimulation in depression
Current nonsurgical vagus nerve stimulation (VNS) approaches often suffer from broad current spread, high electrode-skin impedance, and unintended stimulation of surrounding tissues, which can reduce efficacy and cause side effects. Here, we present a wirelessly operable, skin-attachable VNS patch with three-dimensional liquid-metal electrodes that mimic the low modulus of biological tissues, developed as a minimally invasive platform for investigating the biological mechanisms underlying VNS in a mouse model of depression. The soft, low-modulus three-dimensional liquid metal electrodes gently penetrate the skin, bypass the stratum corneum, and improve electrode–tissue coupling while minimizing tissue damage compared with conventional planar or rigid electrodes. To comprehensively assess therapeutic effects, we conducted behavioral tests, neural probe-based brain signal analysis, dendritic spine density measurements, and blood and inguinal lymph node profiling in depression model mice. VNS increased plasma serotonin levels and increased dendritic spine density, indicating improved neuroplasticity. Corticosterone-induced depressive mice exhibited elevated CD4+ and B220+ cells, which normalized with VNS. These results establish an animal-level proof-of-concept that minimally invasive VNS can engage key neural and immunological pathways relevant to depression, providing a foundation for future neuromodulation strategies.
- Open Access
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaec9837
AI-driven tripartite classification for optimizing wearable bioelectronics in depression management
Current disease-sensing devices primarily focus on distinguishing between healthy and diseased states, effective for diagnosis but limited in guiding optimal intervention timing for prevention. We developed a tripartite framework identifying pre-disease state in depression, a reversible phase preceding irreversible onset. Using complex systems theory, we analyzed early-warning signals emerging as biological systems approach critical transitions. Continuous monitoring of nine multimodal biomarkers—spanning electrophysiological, behavioral, and biological—enabled classification into normal, pre-disease, and disease states by quantitatively defining critical points. An artificial intelligence agent classified disease states with 95.2% accuracy using multimodal data, enabled by ultrasoft neural probes for stable, low-damage recordings. Therapeutic validation with a skin-attachable wireless vagus nerve stimulator integrating soft three-dimensional electrodes demonstrated superior efficacy during pre-disease states. Subjects treated during pre-disease showed faster recovery and greater therapeutic responses, while those treated after disease onset failed to achieve full recovery. This framework provides evidence-based rationale for early intervention.
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaec9837
Open AccessAI-driven tripartite classification for optimizing wearable bioelectronics in depression management
Current disease-sensing devices primarily focus on distinguishing between healthy and diseased states, effective for diagnosis but limited in guiding optimal intervention timing for prevention. We developed a tripartite framework identifying pre-disease state in depression, a reversible phase preceding irreversible onset. Using complex systems theory, we analyzed early-warning signals emerging as biological systems approach critical transitions. Continuous monitoring of nine multimodal biomarkers—spanning electrophysiological, behavioral, and biological—enabled classification into normal, pre-disease, and disease states by quantitatively defining critical points. An artificial intelligence agent classified disease states with 95.2% accuracy using multimodal data, enabled by ultrasoft neural probes for stable, low-damage recordings. Therapeutic validation with a skin-attachable wireless vagus nerve stimulator integrating soft three-dimensional electrodes demonstrated superior efficacy during pre-disease states. Subjects treated during pre-disease showed faster recovery and greater therapeutic responses, while those treated after disease onset failed to achieve full recovery. This framework provides evidence-based rationale for early intervention.
- 9 April 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (16) , 6481-6490
Soft 3D Bioelectrodes for Intraorganoid Signal Monitoring in Cardiac Models
Continuous monitoring of physiological activities within the internal regions of three-dimensional (3D) organoids holds significant promise for advancing organoid-based research. However, conventional methods are constrained to capturing signals from the peripheral surfaces of organoids, limiting insights into internal dynamics. Here, we present a soft 3D bioelectrode platform for continuous intraorganoid signal monitoring. These bioelectrodes, formed via 3D printing of liquid metal, are designed with customizable geometric parameters, including height and diameter, to adapt to various organoid structures. The tissue-comparable softness of the electrodes minimizes damage to cardiac organoids, ensuring a stable interface for reliable signal recording even under dynamic deformations caused by rhythmic contractions or displacements in aqueous environments. The array configuration enables simultaneous electrocardiogram (ECG) recordings from 32 organoids. Demonstrating real-time monitoring of drug-induced ECG responses, this scalable platform highlights its potential for high-throughput drug screening.
- 9 April 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (16) , 6481-6490
Soft 3D Bioelectrodes for Intraorganoid Signal Monitoring in Cardiac Models
Continuous monitoring of physiological activities within the internal regions of three-dimensional (3D) organoids holds significant promise for advancing organoid-based research. However, conventional methods are constrained to capturing signals from the peripheral surfaces of organoids, limiting insights into internal dynamics. Here, we present a soft 3D bioelectrode platform for continuous intraorganoid signal monitoring. These bioelectrodes, formed via 3D printing of liquid metal, are designed with customizable geometric parameters, including height and diameter, to adapt to various organoid structures. The tissue-comparable softness of the electrodes minimizes damage to cardiac organoids, ensuring a stable interface for reliable signal recording even under dynamic deformations caused by rhythmic contractions or displacements in aqueous environments. The array configuration enables simultaneous electrocardiogram (ECG) recordings from 32 organoids. Demonstrating real-time monitoring of drug-induced ECG responses, this scalable platform highlights its potential for high-throughput drug screening.
- Top Cited Papers
- 17 February 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (7) , 7337-7349
Implantable Soft Neural Electrodes of Liquid Metals for Deep Brain Stimulation
Stimulating large volumes of neural networks using macroelectrodes can modulate disorder-associated brain circuits effectively. However, conventional solid-metal electrodes often cause unwanted brain damage due to their high mechanical stiffness. In contrast, low-modulus liquid metals provide tissue-like stiffness while maintaining macroscale electrode dimensions. Here, we present implantable soft macroelectrodes made from biocompatible liquid metals for brain stimulation. These probes can be easily fabricated by simply filling polymeric tubes with a liquid metal, offering a straightforward method for creating brain stimulation devices. They can be customized in various lengths and diameters and also serve as recording microelectrodes. The electrode tips are enhanced with platinum nanoclusters, resulting in low impedance and effective charge injection while preventing liquid metal leakage into brain tissue. In vivo experiments in neuropathic pain rat models demonstrate the stability and effectiveness of these probes for simultaneous neural stimulation and recording, demonstrating their potential for pain alleviation and behavioral control.
- 17 February 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (7) , 7337-7349
Top Cited PapersImplantable Soft Neural Electrodes of Liquid Metals for Deep Brain Stimulation
Stimulating large volumes of neural networks using macroelectrodes can modulate disorder-associated brain circuits effectively. However, conventional solid-metal electrodes often cause unwanted brain damage due to their high mechanical stiffness. In contrast, low-modulus liquid metals provide tissue-like stiffness while maintaining macroscale electrode dimensions. Here, we present implantable soft macroelectrodes made from biocompatible liquid metals for brain stimulation. These probes can be easily fabricated by simply filling polymeric tubes with a liquid metal, offering a straightforward method for creating brain stimulation devices. They can be customized in various lengths and diameters and also serve as recording microelectrodes. The electrode tips are enhanced with platinum nanoclusters, resulting in low impedance and effective charge injection while preventing liquid metal leakage into brain tissue. In vivo experiments in neuropathic pain rat models demonstrate the stability and effectiveness of these probes for simultaneous neural stimulation and recording, demonstrating their potential for pain alleviation and behavioral control.
- Open Access
- 21 August 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
Interference haptic stimulation and consistent quantitative tactility in transparent electrotactile screen with pressure-sensitive transistors
Integrating tactile feedback through haptic interfaces enhances experiences in virtual and augmented reality. However, electrotactile systems, which stimulate mechanoreceptors directly, often yield inconsistent tactile results due to variations in pressure between the device and the finger. In this study, we present the integration of a transparent electrotactile screen with pressure-sensitive transistors, ensuring highly consistent quantitative haptic sensations. These transistors effectively calibrate tactile variations caused by touch pressure. Additionally, we explore remote-distance tactile stimulations achieved through the interference of electromagnetic waves. We validated tactile perception using somatosensory evoked potentials, monitoring the somatosensory cortex response. Our haptic screen can stimulate diverse electrotactile sensations and demonstrate various tactile patterns, including Morse code and Braille, when integrated with portable smart devices, delivering a more immersive experience. Furthermore, interference of electric fields allows haptic stimulation to facilitate diverse stimulus positioning at lower current densities, extending the reach beyond direct contact with electrodes of our screen.
- 21 August 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
Open AccessInterference haptic stimulation and consistent quantitative tactility in transparent electrotactile screen with pressure-sensitive transistors
Integrating tactile feedback through haptic interfaces enhances experiences in virtual and augmented reality. However, electrotactile systems, which stimulate mechanoreceptors directly, often yield inconsistent tactile results due to variations in pressure between the device and the finger. In this study, we present the integration of a transparent electrotactile screen with pressure-sensitive transistors, ensuring highly consistent quantitative haptic sensations. These transistors effectively calibrate tactile variations caused by touch pressure. Additionally, we explore remote-distance tactile stimulations achieved through the interference of electromagnetic waves. We validated tactile perception using somatosensory evoked potentials, monitoring the somatosensory cortex response. Our haptic screen can stimulate diverse electrotactile sensations and demonstrate various tactile patterns, including Morse code and Braille, when integrated with portable smart devices, delivering a more immersive experience. Furthermore, interference of electric fields allows haptic stimulation to facilitate diverse stimulus positioning at lower current densities, extending the reach beyond direct contact with electrodes of our screen.
- Open Access
- 21 August 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-9
A seamless auxetic substrate with a negative Poisson’s ratio of −1
Auxetic metamaterials are a unique class of materials or structures with a negative Poisson’s ratio and a wide array of functionalities. However, their inherent porosity presents challenges in practical applications. Filling the inherent perforations while preserving their unique auxeticity is difficult because it demands the seamless integration of components that have highly distinct mechanical characteristics. Here we introduce a seamless auxetic substrate film capable of achieving a negative Poisson’s ratio of −1, the theoretical limit of isotropic materials. This breakthrough is realized by incorporating a highly rigid auxetic structure reinforced by glass-fabric, with surface-flattening soft elastomers. We effectively optimize the mechanical properties of these components by systematic experimental and theoretical investigations into the effects of relative differences in the moduli of the constituents. Using the developed auxetic film we demonstrate an image distortion-free display having 25 PPI resolution of micro-LEDs that is capable of 25% stretching without performance degradation.
- 21 August 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-9
Open AccessA seamless auxetic substrate with a negative Poisson’s ratio of −1
Auxetic metamaterials are a unique class of materials or structures with a negative Poisson’s ratio and a wide array of functionalities. However, their inherent porosity presents challenges in practical applications. Filling the inherent perforations while preserving their unique auxeticity is difficult because it demands the seamless integration of components that have highly distinct mechanical characteristics. Here we introduce a seamless auxetic substrate film capable of achieving a negative Poisson’s ratio of −1, the theoretical limit of isotropic materials. This breakthrough is realized by incorporating a highly rigid auxetic structure reinforced by glass-fabric, with surface-flattening soft elastomers. We effectively optimize the mechanical properties of these components by systematic experimental and theoretical investigations into the effects of relative differences in the moduli of the constituents. Using the developed auxetic film we demonstrate an image distortion-free display having 25 PPI resolution of micro-LEDs that is capable of 25% stretching without performance degradation.
- 21 August 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (35) , 24364-24378
Three-Dimensional Electrodes of Liquid Metals for Long-Term, Wireless Cardiac Analysis and Modulation
Cardiovascular disease is a major public health issue, and smart diagnostic approaches play an important role in the analysis of electrocardiograms. Here, we present three-dimensional, soft electrodes of liquid metals that can be conformably attached to the surfaces of the heart and skin for long-term cardiac analysis. The fine micropillar structures of biocompatible liquid metals enable precise targeting to small tissue areas, allowing for spatiotemporal mapping and modulation of cardiac electrical activity with high resolution. The low mechanical modulus of these liquid-metal electrodes not only helps avoid inflammatory responses triggered by modulus mismatch between the tissue and electrodes, but also minimizes pain when embedded in biological tissues such as the skin and heart. Furthermore, in vivo experiments with animal models and human trials demonstrate long-term and accurate monitoring of electrocardiograms over a period of 30 days.
- 21 August 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (35) , 24364-24378
Three-Dimensional Electrodes of Liquid Metals for Long-Term, Wireless Cardiac Analysis and Modulation
Cardiovascular disease is a major public health issue, and smart diagnostic approaches play an important role in the analysis of electrocardiograms. Here, we present three-dimensional, soft electrodes of liquid metals that can be conformably attached to the surfaces of the heart and skin for long-term cardiac analysis. The fine micropillar structures of biocompatible liquid metals enable precise targeting to small tissue areas, allowing for spatiotemporal mapping and modulation of cardiac electrical activity with high resolution. The low mechanical modulus of these liquid-metal electrodes not only helps avoid inflammatory responses triggered by modulus mismatch between the tissue and electrodes, but also minimizes pain when embedded in biological tissues such as the skin and heart. Furthermore, in vivo experiments with animal models and human trials demonstrate long-term and accurate monitoring of electrocardiograms over a period of 30 days.
- Top Cited PapersOpen Access
- 2 April 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
In-depth correlation analysis between tear glucose and blood glucose using a wireless smart contact lens
Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called ‘personalized lag time’. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.
- 2 April 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
Top Cited PapersOpen AccessIn-depth correlation analysis between tear glucose and blood glucose using a wireless smart contact lens
Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called ‘personalized lag time’. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.
- Top Cited PapersOpen Access
- 25 September 2023
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 123 (19) , 11488-11558
Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.
- 25 September 2023
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 123 (19) , 11488-11558
Top Cited PapersOpen AccessSmart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.
- Open Access
- 7 June 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (24) , 28954-28963
Magnetic Manipulation of Locomotive Liquid Electrodes for Wireless Active Cardiac Monitoring
For electrocardiogram (ECG) detection, the position of conventional patch-type electrodes based on solid-state metals are difficult to manipulate after attachment and also can lead to poor interface with stretchable, rough skin surfaces. Herein, we present a liquid form of ECG electrodes that can be magnetically reconfigured on human skin by providing its conformal interfacing. These electrodes consist of biocompatible liquid-metal droplets where magnetic particles are homogeneously dispersed, and their conformal contact with skin can yield significantly low impedance as well as high signal-to-noise ratio of ECG peaks. These electrodes are also capable of complex motions such as linear movements, splitting, and merging under external magnetic fields. Furthermore, magnetic manipulation of each electrode position on human skin enables precise monitoring of ECG signals with the change in ECG vectors. The integration of liquid-state electrodes with electronic circuitry demonstrates wireless and continuous ECG monitoring while magnetically moving this entire system on human skin.
- 7 June 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (24) , 28954-28963
Open AccessMagnetic Manipulation of Locomotive Liquid Electrodes for Wireless Active Cardiac Monitoring
For electrocardiogram (ECG) detection, the position of conventional patch-type electrodes based on solid-state metals are difficult to manipulate after attachment and also can lead to poor interface with stretchable, rough skin surfaces. Herein, we present a liquid form of ECG electrodes that can be magnetically reconfigured on human skin by providing its conformal interfacing. These electrodes consist of biocompatible liquid-metal droplets where magnetic particles are homogeneously dispersed, and their conformal contact with skin can yield significantly low impedance as well as high signal-to-noise ratio of ECG peaks. These electrodes are also capable of complex motions such as linear movements, splitting, and merging under external magnetic fields. Furthermore, magnetic manipulation of each electrode position on human skin enables precise monitoring of ECG signals with the change in ECG vectors. The integration of liquid-state electrodes with electronic circuitry demonstrates wireless and continuous ECG monitoring while magnetically moving this entire system on human skin.