Wonjung Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wonjung Park has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Jang-Ung Park
Department of Materials Science and Engineering, Yonsei University
10 shared publications - Hayoung Song
Department of Materials Science and Engineering, Yonsei University
7 shared publications - Hunkyu Seo
Department of Materials Science and Engineering, Yonsei University College of Engineering, Seoul 03722, Republic of Korea
7 shared publications - Jakyoung Lee
Department of Materials Science and Engineering, Yonsei University College of Engineering, Seoul 03722, Republic of Korea
7 shared publications - Sumin Kim
Department of Materials Science and Engineering, Yonsei University
6 shared publications - Enji Kim
Department of Materials Science and Engineering, Yonsei University, Seoul, Republic of Korea
5 shared publications
Latest Publications
- 12 September 2026
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 20 (37) , 25660-25673
Tear-Based Dynamic Network Biomarkers for Pre-Disease Detection of Hyperuricemic Nephropathy via Smart Contact Lens
Early identification of the pre-disease state is critical for effective intervention and improved outcomes in chronic kidney disease. However, current diagnostic approaches mainly rely on serum-based biomarkers, which are limited in capturing dynamic physiological changes or enabling real-time monitoring. Here, we present a smart contact lens (SCL) platform capable of real-time, non-invasive monitoring of tear uric acid (TUA) levels. The system integrates an electrochemical biosensor and wireless communication module, offering high sensitivity, stability, and selectivity. Using a hyperuricemic nephropathy (HN) rabbit model, we continuously tracked TUA levels and applied dynamic network biomarker (DNB) theory to identify the critical transition point preceding irreversible disease onset. The DNB-derived composite index enabled personalized identification of critical transition periods and detection of the reversible pre-disease state before progression to HN. Furthermore, longitudinal analysis revealed progressive shortening of the blood-to-tear diffusion lag time during disease progression, introducing transport kinetics as an additional dynamic biomarker associated with pathological changes. Continuous tear-derived dynamic signatures enabled more sensitive detection of early disease transitions than static serum biomarkers, highlighting the value of waveform-based analysis for pre-disease monitoring. Together, this work provides a framework for wearable, tear-based early warning signal detection and personalized monitoring of kidney dysfunction.
- 12 September 2026
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 20 (37) , 25660-25673
Tear-Based Dynamic Network Biomarkers for Pre-Disease Detection of Hyperuricemic Nephropathy via Smart Contact Lens
Early identification of the pre-disease state is critical for effective intervention and improved outcomes in chronic kidney disease. However, current diagnostic approaches mainly rely on serum-based biomarkers, which are limited in capturing dynamic physiological changes or enabling real-time monitoring. Here, we present a smart contact lens (SCL) platform capable of real-time, non-invasive monitoring of tear uric acid (TUA) levels. The system integrates an electrochemical biosensor and wireless communication module, offering high sensitivity, stability, and selectivity. Using a hyperuricemic nephropathy (HN) rabbit model, we continuously tracked TUA levels and applied dynamic network biomarker (DNB) theory to identify the critical transition point preceding irreversible disease onset. The DNB-derived composite index enabled personalized identification of critical transition periods and detection of the reversible pre-disease state before progression to HN. Furthermore, longitudinal analysis revealed progressive shortening of the blood-to-tear diffusion lag time during disease progression, introducing transport kinetics as an additional dynamic biomarker associated with pathological changes. Continuous tear-derived dynamic signatures enabled more sensitive detection of early disease transitions than static serum biomarkers, highlighting the value of waveform-based analysis for pre-disease monitoring. Together, this work provides a framework for wearable, tear-based early warning signal detection and personalized monitoring of kidney dysfunction.
- Open Access
- 22 July 2026
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 123 (30)
Wireless, skin-attachable patch with 3D liquid metal electrodes for vagus nerve stimulation in depression
Current nonsurgical vagus nerve stimulation (VNS) approaches often suffer from broad current spread, high electrode-skin impedance, and unintended stimulation of surrounding tissues, which can reduce efficacy and cause side effects. Here, we present a wirelessly operable, skin-attachable VNS patch with three-dimensional liquid-metal electrodes that mimic the low modulus of biological tissues, developed as a minimally invasive platform for investigating the biological mechanisms underlying VNS in a mouse model of depression. The soft, low-modulus three-dimensional liquid metal electrodes gently penetrate the skin, bypass the stratum corneum, and improve electrode–tissue coupling while minimizing tissue damage compared with conventional planar or rigid electrodes. To comprehensively assess therapeutic effects, we conducted behavioral tests, neural probe-based brain signal analysis, dendritic spine density measurements, and blood and inguinal lymph node profiling in depression model mice. VNS increased plasma serotonin levels and increased dendritic spine density, indicating improved neuroplasticity. Corticosterone-induced depressive mice exhibited elevated CD4+ and B220+ cells, which normalized with VNS. These results establish an animal-level proof-of-concept that minimally invasive VNS can engage key neural and immunological pathways relevant to depression, providing a foundation for future neuromodulation strategies.
- 22 July 2026
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 123 (30)
Open AccessWireless, skin-attachable patch with 3D liquid metal electrodes for vagus nerve stimulation in depression
Current nonsurgical vagus nerve stimulation (VNS) approaches often suffer from broad current spread, high electrode-skin impedance, and unintended stimulation of surrounding tissues, which can reduce efficacy and cause side effects. Here, we present a wirelessly operable, skin-attachable VNS patch with three-dimensional liquid-metal electrodes that mimic the low modulus of biological tissues, developed as a minimally invasive platform for investigating the biological mechanisms underlying VNS in a mouse model of depression. The soft, low-modulus three-dimensional liquid metal electrodes gently penetrate the skin, bypass the stratum corneum, and improve electrode–tissue coupling while minimizing tissue damage compared with conventional planar or rigid electrodes. To comprehensively assess therapeutic effects, we conducted behavioral tests, neural probe-based brain signal analysis, dendritic spine density measurements, and blood and inguinal lymph node profiling in depression model mice. VNS increased plasma serotonin levels and increased dendritic spine density, indicating improved neuroplasticity. Corticosterone-induced depressive mice exhibited elevated CD4+ and B220+ cells, which normalized with VNS. These results establish an animal-level proof-of-concept that minimally invasive VNS can engage key neural and immunological pathways relevant to depression, providing a foundation for future neuromodulation strategies.
- Open Access
- 20 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8859
Neural dynamics of temporal interference stimulation monitoring by soft liquid metal interfaces across neural systems
- 20 July 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8859
Open AccessNeural dynamics of temporal interference stimulation monitoring by soft liquid metal interfaces across neural systems
- Open Access
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaec9837
AI-driven tripartite classification for optimizing wearable bioelectronics in depression management
Current disease-sensing devices primarily focus on distinguishing between healthy and diseased states, effective for diagnosis but limited in guiding optimal intervention timing for prevention. We developed a tripartite framework identifying pre-disease state in depression, a reversible phase preceding irreversible onset. Using complex systems theory, we analyzed early-warning signals emerging as biological systems approach critical transitions. Continuous monitoring of nine multimodal biomarkers—spanning electrophysiological, behavioral, and biological—enabled classification into normal, pre-disease, and disease states by quantitatively defining critical points. An artificial intelligence agent classified disease states with 95.2% accuracy using multimodal data, enabled by ultrasoft neural probes for stable, low-damage recordings. Therapeutic validation with a skin-attachable wireless vagus nerve stimulator integrating soft three-dimensional electrodes demonstrated superior efficacy during pre-disease states. Subjects treated during pre-disease showed faster recovery and greater therapeutic responses, while those treated after disease onset failed to achieve full recovery. This framework provides evidence-based rationale for early intervention.
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaec9837
Open AccessAI-driven tripartite classification for optimizing wearable bioelectronics in depression management
Current disease-sensing devices primarily focus on distinguishing between healthy and diseased states, effective for diagnosis but limited in guiding optimal intervention timing for prevention. We developed a tripartite framework identifying pre-disease state in depression, a reversible phase preceding irreversible onset. Using complex systems theory, we analyzed early-warning signals emerging as biological systems approach critical transitions. Continuous monitoring of nine multimodal biomarkers—spanning electrophysiological, behavioral, and biological—enabled classification into normal, pre-disease, and disease states by quantitatively defining critical points. An artificial intelligence agent classified disease states with 95.2% accuracy using multimodal data, enabled by ultrasoft neural probes for stable, low-damage recordings. Therapeutic validation with a skin-attachable wireless vagus nerve stimulator integrating soft three-dimensional electrodes demonstrated superior efficacy during pre-disease states. Subjects treated during pre-disease showed faster recovery and greater therapeutic responses, while those treated after disease onset failed to achieve full recovery. This framework provides evidence-based rationale for early intervention.
- Open Access
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaee8506
Smart contact lens–trained digital twin for device-free personalized uric acid prediction
Tears contain valuable biomarkers and offer potential for noninvasive disease monitoring. However, the lack of correlation analysis between serum uric acid (SUA) and tear uric acid (TUA) has limited their clinical application in personalized medicine. Here, we present a wireless smart contact lens capable of real-time, noninvasive monitoring of TUA as an alternative to blood-based UA testing. We validated the device through correlation analysis in rabbits and human participants, including individuals with hyperuricemia and gout. Daily-life monitoring enabled personalized characterization of TUA fluctuations in response to food intake and physical activity, together with individualized lag time profiling. A strong linear relationship allowed development of a regression model to derive estimated SUA from TUA. Building on these temporal profiles, lifestyle-informed digital twins were constructed to predict daily uric acid dynamics without continuous lens wear. This digital twin–enabled, device-free framework provides a practical route toward unobtrusive and personalized metabolic health monitoring.
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaee8506
Open AccessSmart contact lens–trained digital twin for device-free personalized uric acid prediction
Tears contain valuable biomarkers and offer potential for noninvasive disease monitoring. However, the lack of correlation analysis between serum uric acid (SUA) and tear uric acid (TUA) has limited their clinical application in personalized medicine. Here, we present a wireless smart contact lens capable of real-time, noninvasive monitoring of TUA as an alternative to blood-based UA testing. We validated the device through correlation analysis in rabbits and human participants, including individuals with hyperuricemia and gout. Daily-life monitoring enabled personalized characterization of TUA fluctuations in response to food intake and physical activity, together with individualized lag time profiling. A strong linear relationship allowed development of a regression model to derive estimated SUA from TUA. Building on these temporal profiles, lifestyle-informed digital twins were constructed to predict daily uric acid dynamics without continuous lens wear. This digital twin–enabled, device-free framework provides a practical route toward unobtrusive and personalized metabolic health monitoring.
- 21 August 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (35) , 24364-24378
Three-Dimensional Electrodes of Liquid Metals for Long-Term, Wireless Cardiac Analysis and Modulation
Cardiovascular disease is a major public health issue, and smart diagnostic approaches play an important role in the analysis of electrocardiograms. Here, we present three-dimensional, soft electrodes of liquid metals that can be conformably attached to the surfaces of the heart and skin for long-term cardiac analysis. The fine micropillar structures of biocompatible liquid metals enable precise targeting to small tissue areas, allowing for spatiotemporal mapping and modulation of cardiac electrical activity with high resolution. The low mechanical modulus of these liquid-metal electrodes not only helps avoid inflammatory responses triggered by modulus mismatch between the tissue and electrodes, but also minimizes pain when embedded in biological tissues such as the skin and heart. Furthermore, in vivo experiments with animal models and human trials demonstrate long-term and accurate monitoring of electrocardiograms over a period of 30 days.
- 21 August 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (35) , 24364-24378
Three-Dimensional Electrodes of Liquid Metals for Long-Term, Wireless Cardiac Analysis and Modulation
Cardiovascular disease is a major public health issue, and smart diagnostic approaches play an important role in the analysis of electrocardiograms. Here, we present three-dimensional, soft electrodes of liquid metals that can be conformably attached to the surfaces of the heart and skin for long-term cardiac analysis. The fine micropillar structures of biocompatible liquid metals enable precise targeting to small tissue areas, allowing for spatiotemporal mapping and modulation of cardiac electrical activity with high resolution. The low mechanical modulus of these liquid-metal electrodes not only helps avoid inflammatory responses triggered by modulus mismatch between the tissue and electrodes, but also minimizes pain when embedded in biological tissues such as the skin and heart. Furthermore, in vivo experiments with animal models and human trials demonstrate long-term and accurate monitoring of electrocardiograms over a period of 30 days.
- Top Cited PapersOpen Access
- 2 April 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
In-depth correlation analysis between tear glucose and blood glucose using a wireless smart contact lens
Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called ‘personalized lag time’. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.
- 2 April 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
Top Cited PapersOpen AccessIn-depth correlation analysis between tear glucose and blood glucose using a wireless smart contact lens
Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called ‘personalized lag time’. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.
- Open Access
- 9 February 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (6) , eadk7805
Real-time in vivo monitoring of intraocular pressure distribution in the anterior chamber and vitreous chamber for diagnosis of glaucoma
Glaucoma causes irreversible vision loss due to optic nerve damage and retinal cell degeneration. Since high intraocular pressure (IOP) is a major risk factor for glaucoma development, accurate IOP measurement is crucial, especially intravitreal IOP affecting the optical nerve and cells. However, conventional methods have limits in selectively and directly detecting local retina pressure. Here, we present continuous measurements of local IOP values in the anterior chamber and vitreous chamber of living animals using minimally invasive probes with pressure-sensitive transistors. After inducing glaucoma in animal models, we compared the local IOP distribution between normal and glaucomatous eyes. We also compared IOP values detected in the cornea using tonometry measurements. Our findings revealed that glaucoma induced higher IOP in the vitreous chamber than in the anterior chamber, indicating that measuring IOP in the vitreous chamber is key to the glaucoma model. This progress offers future directions for diagnosis and treatment of glaucoma.
- 9 February 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (6) , eadk7805
Open AccessReal-time in vivo monitoring of intraocular pressure distribution in the anterior chamber and vitreous chamber for diagnosis of glaucoma
Glaucoma causes irreversible vision loss due to optic nerve damage and retinal cell degeneration. Since high intraocular pressure (IOP) is a major risk factor for glaucoma development, accurate IOP measurement is crucial, especially intravitreal IOP affecting the optical nerve and cells. However, conventional methods have limits in selectively and directly detecting local retina pressure. Here, we present continuous measurements of local IOP values in the anterior chamber and vitreous chamber of living animals using minimally invasive probes with pressure-sensitive transistors. After inducing glaucoma in animal models, we compared the local IOP distribution between normal and glaucomatous eyes. We also compared IOP values detected in the cornea using tonometry measurements. Our findings revealed that glaucoma induced higher IOP in the vitreous chamber than in the anterior chamber, indicating that measuring IOP in the vitreous chamber is key to the glaucoma model. This progress offers future directions for diagnosis and treatment of glaucoma.
- Top Cited PapersOpen Access
- 25 September 2023
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 123 (19) , 11488-11558
Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.
- 25 September 2023
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 123 (19) , 11488-11558
Top Cited PapersOpen AccessSmart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.
- 27 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 5 (4) , 1926-1946
Materials and Structural Designs for Neural Interfaces
- 27 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 5 (4) , 1926-1946
Materials and Structural Designs for Neural Interfaces