ASAchraj Sarma

Achraj Sarma

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Achraj Sarma has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Corrections to “Model-Based Design of the COAST Guidewire Robot for Large Deflection”

    by Yash Chitalia, Achraj Sarma, Timothy A. Brumfiel, Nancy J. Deaton, Maxina Sheft, Jaydev P. Desai

    Presents corrections to the article “Model-Based Design of the COAST Guidewire Robot for Large Deflection.

  • Model-Based Design of the COAST Guidewire Robot for Large Deflection

    by Yash Chitalia, Achraj Sarma, Timothy A. Brumfiel, Nancy J. Deaton, Maxina Sheft, Jaydev P. Desai

    Minimally invasive endovascular procedures involve the manual placement of a guidewire, which is made difficult by vascular tortuosity and the lack of precise tip control. Steerable guidewire systems have been developed with tendon-driven, magnetic, and concentric tube actuation strategies to enable precise tip control, however, selecting machining parameters for such robots does not have a strict procedure. In this letter, we develop a systematic design procedure for selecting the tube pairs of the CO axially A ligned ST eerable (COAST) guidewire robot. This includes the introduction of a mechanical model that accounts for micromachining-induced pre-curvatures with the goal of determining design parameters that reduce combined distal tip pre-curvature and minimize abrupt changes in actuated tip position for the COAST guidewire robot through selection of the best flexural rigidity between the tube pairs. We present adjustments in the kinematics modeling of COAST robot tip bending motion, and use these to characterize the bending behavior of the COAST robot for varying geometries of the micromachined tubes, with an average RMSE value for the tip position error of 0.816 mm in the validation study.


  • Simultaneous Shape and Tip Force Sensing for the COAST Guidewire Robot

    by Nancy J. Deaton, Timothy A. Brumfiel, Achraj Sarma, Jaydev P. Desai

    Placement of catheters in minimally invasive cardiovascular procedures is preceded by navigating to the target lesion with a guidewire. Traversing through tortuous vascular pathways can be challenging without precise tip control, potentially resulting in the damage or perforation of blood vessels. To improve guidewire navigation, this letter presents 3D shape reconstruction and tip force sensing for the COaxially Aligned STeerable (COAST) guidewire robot using a triplet of adhered single core fiber Bragg grating sensors routed centrally through the robot's slender structure. Additionally, several shape reconstruction algorithms are compared, and shape measurements are utilized to enable tip force sensing. Demonstration of the capabilities of the robot is shown in free air where the shape of the robot is reconstructed with average errors less than 2 mm at the guidewire tip, and the magnitudes of forces applied to the tip are estimated with an RMSE of 0.027 N or less.


  • Real-Time Pose Tracking for a Continuum Guidewire Robot Under Fluoroscopic Imaging

    by Sharan R. Ravigopal, Achraj Sarma, Timothy A. Brumfiel, Jaydev P. Desai

    Atherosclerosis is a medical condition that causes buildup of plaque in the blood vessels and narrowing of the arteries. Surgeons often treat this condition through angioplasty with catheter placements. Continuum guidewire robots offer significant advantages for catheter placements due to their dexterity. Tracking these guidewire robots and their surrounding workspace under fluoroscopy in real-time can be useful for visualization and accurate control. This paper discusses algorithms and methods to track the shape and orientation of the guidewire and the surrounding workspaces of phantom vasculatures in real-time under C-arm fluoroscopy. The shape of continuum guidewires is found through a semantic segmentation architecture based on MobileNetv2 with a Tversky loss function to deal with class imbalances. This shape is refined through medial axis filtering and parametric curve fitting to quantitatively describe the guidewire’s pose. Using a constant curvature assumption for the guidewire’s bending segments, the parameters that describe the joint variables are estimated in real-time for a tendon-actuated COaxially Aligned STeerable (COAST) guidewire robot and tracked through its traversal of an aortic bifurcation phantom. The accuracy of the tracking is ˜90% and the execution times are within 100 ms, and hence this method is deemed suitable for real-time tracking.


  • Kinematic Modeling and Jacobian-Based Control of the COAST Guidewire Robot

    by Achraj Sarma, Timothy A. Brumfiel, Yash Chitalia, Jaydev P. Desai

    Manual guidewire navigation and placement for minimally invasive surgeries suffer from technical challenges due to imprecise tip motion control to traverse highly tortuous vasculature. Robotically steerable guidewires can address these challenges by actuating a compliant tip through multiple degrees-of-freedom for maneuvering through vascular pathways. In this paper, we detail the kinematic mapping of a CO axially A ligned ST eerable (COAST) guidewire robot that is capable of executing follow-the-leader motion in three dimensional vascular pathways. We also develop an analytical Jacobian model to perform velocity kinematics for the robot and finally, we implement Jacobian-based control to demonstrate follow-the-leader motion of the guidewire in free space, within 3D-printed phantoms, and within ex vivo animal vasculature.


  • Fluoroscopic Image-Based 3-D Environment Reconstruction and Automated Path Planning for a Robotically Steerable Guidewire

    by Sharan R. Ravigopal, Timothy A. Brumfiel, Achraj Sarma, Jaydev P. Desai

    Cardiovascular diseases are the leading cause of death globally and surgical treatments for these often begin with the manual placement of a long compliant wire, called a guidewire, through different vasculature. To improve procedure outcomes and reduce radiation exposure, we propose steps towards a fully automated approach for steerable guidewire navigation within vessels. In this letter, we utilize fluoroscopic images to fully reconstruct 3-D printed phantom vasculature models by using a shape-from-silhouette algorithm. The reconstruction is subsequently de-noised using a deep learning-based encoder-decoder network and morphological filtering. This volume is used to model the environment for guidewire traversal. Following this, we present a novel method to plan an optimal path for guidewire traversal in three-dimensional vascular models through the use of slice planes and a modified hybrid A-star algorithm. Finally, the developed reconstruction and planning approaches are applied to an ex vivo porcine aorta, and navigation is demonstrated through the use of a tendon-actuated CO axially A ligned ST eerable guidewire (COAST).