Sharan R. Ravigopal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sharan R. Ravigopal has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jaydev P. Desai
Georgia Institute of Technology
4 shared publications - Achraj Sarma
Matician Inc, Mountain View, CA, USA
2 shared publications Timothy A. Brumfiel
Wallace H. Coulter Department of Biomedical Engineering, Medical Robotics and Automation (RoboMed) Laboratory, Georgia Institute of Technology, Atlanta, GA, USA
2 shared publications- Namrata U. Nayar
Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publication - Ronghuai Qi
Wallace H. Coulter Department of Biomedical Engineering, Medical Robotics and Automation Laboratory, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publication - Timothy A. Brumfiel
Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publication
Latest Publications
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 153-162
Image-Based Force Localization and Estimation of a Micro-Scale Continuum Guidewire Robot
Many intravascular procedures are prefaced by the placement of a slender wire called a guidewire. Steering these guidewires is met with challenges in controlling the distal end along with the possibility of damaging vessel walls, or even perforation, which can be fatal. To this end, utilizing robotic guidewires can improve steerability and enable force feedback through intrinsic force sensing. Enabling force sensing contains challenges such as discrete sensor placements in continuous structures and non-unique force distributions for a given deflection. In this work, we utilize image feedback and a Cosserat rod model to estimate and localize forces along the body of a micro-scale tendon-driven guidewire robot. This includes additional modeling of friction and hysteresis that is often neglected for force sensing. The model is tested on a variety of notched nitinol tubes under gravity loading with the shape predictions having an average RMSE of 0.46 mm. Utilization of friction and hysteresis models provide shape predictions with an RMSE of 1.22 mm compared to an uncompensated model (RMSE ${=}$ 1.62 mm) for approximately 180° bends. The methods presented are able to localize forces with an average error of 4.79 mm (5.15% of the length) while force magnitudes are estimated with an average error of 13.03 mN.
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 153-162
Image-Based Force Localization and Estimation of a Micro-Scale Continuum Guidewire Robot
Many intravascular procedures are prefaced by the placement of a slender wire called a guidewire. Steering these guidewires is met with challenges in controlling the distal end along with the possibility of damaging vessel walls, or even perforation, which can be fatal. To this end, utilizing robotic guidewires can improve steerability and enable force feedback through intrinsic force sensing. Enabling force sensing contains challenges such as discrete sensor placements in continuous structures and non-unique force distributions for a given deflection. In this work, we utilize image feedback and a Cosserat rod model to estimate and localize forces along the body of a micro-scale tendon-driven guidewire robot. This includes additional modeling of friction and hysteresis that is often neglected for force sensing. The model is tested on a variety of notched nitinol tubes under gravity loading with the shape predictions having an average RMSE of 0.46 mm. Utilization of friction and hysteresis models provide shape predictions with an RMSE of 1.22 mm compared to an uncompensated model (RMSE ${=}$ 1.62 mm) for approximately 180° bends. The methods presented are able to localize forces with an average error of 4.79 mm (5.15% of the length) while force magnitudes are estimated with an average error of 13.03 mN.
- 22 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (2) , 230-241
Real-Time Pose Tracking for a Continuum Guidewire Robot Under Fluoroscopic Imaging
Atherosclerosis is a medical condition that causes buildup of plaque in the blood vessels and narrowing of the arteries. Surgeons often treat this condition through angioplasty with catheter placements. Continuum guidewire robots offer significant advantages for catheter placements due to their dexterity. Tracking these guidewire robots and their surrounding workspace under fluoroscopy in real-time can be useful for visualization and accurate control. This paper discusses algorithms and methods to track the shape and orientation of the guidewire and the surrounding workspaces of phantom vasculatures in real-time under C-arm fluoroscopy. The shape of continuum guidewires is found through a semantic segmentation architecture based on MobileNetv2 with a Tversky loss function to deal with class imbalances. This shape is refined through medial axis filtering and parametric curve fitting to quantitatively describe the guidewire’s pose. Using a constant curvature assumption for the guidewire’s bending segments, the parameters that describe the joint variables are estimated in real-time for a tendon-actuated COaxially Aligned STeerable (COAST) guidewire robot and tracked through its traversal of an aortic bifurcation phantom. The accuracy of the tracking is ˜90% and the execution times are within 100 ms, and hence this method is deemed suitable for real-time tracking.
- 22 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (2) , 230-241
Real-Time Pose Tracking for a Continuum Guidewire Robot Under Fluoroscopic Imaging
Atherosclerosis is a medical condition that causes buildup of plaque in the blood vessels and narrowing of the arteries. Surgeons often treat this condition through angioplasty with catheter placements. Continuum guidewire robots offer significant advantages for catheter placements due to their dexterity. Tracking these guidewire robots and their surrounding workspace under fluoroscopy in real-time can be useful for visualization and accurate control. This paper discusses algorithms and methods to track the shape and orientation of the guidewire and the surrounding workspaces of phantom vasculatures in real-time under C-arm fluoroscopy. The shape of continuum guidewires is found through a semantic segmentation architecture based on MobileNetv2 with a Tversky loss function to deal with class imbalances. This shape is refined through medial axis filtering and parametric curve fitting to quantitatively describe the guidewire’s pose. Using a constant curvature assumption for the guidewire’s bending segments, the parameters that describe the joint variables are estimated in real-time for a tendon-actuated COaxially Aligned STeerable (COAST) guidewire robot and tracked through its traversal of an aortic bifurcation phantom. The accuracy of the tracking is ˜90% and the execution times are within 100 ms, and hence this method is deemed suitable for real-time tracking.
- 19 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (4) , 11918-11925
Fluoroscopic Image-Based 3-D Environment Reconstruction and Automated Path Planning for a Robotically Steerable Guidewire
Cardiovascular diseases are the leading cause of death globally and surgical treatments for these often begin with the manual placement of a long compliant wire, called a guidewire, through different vasculature. To improve procedure outcomes and reduce radiation exposure, we propose steps towards a fully automated approach for steerable guidewire navigation within vessels. In this letter, we utilize fluoroscopic images to fully reconstruct 3-D printed phantom vasculature models by using a shape-from-silhouette algorithm. The reconstruction is subsequently de-noised using a deep learning-based encoder-decoder network and morphological filtering. This volume is used to model the environment for guidewire traversal. Following this, we present a novel method to plan an optimal path for guidewire traversal in three-dimensional vascular models through the use of slice planes and a modified hybrid A-star algorithm. Finally, the developed reconstruction and planning approaches are applied to an ex vivo porcine aorta, and navigation is demonstrated through the use of a tendon-actuated CO axially A ligned ST eerable guidewire (COAST).
- 19 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (4) , 11918-11925
Fluoroscopic Image-Based 3-D Environment Reconstruction and Automated Path Planning for a Robotically Steerable Guidewire
Cardiovascular diseases are the leading cause of death globally and surgical treatments for these often begin with the manual placement of a long compliant wire, called a guidewire, through different vasculature. To improve procedure outcomes and reduce radiation exposure, we propose steps towards a fully automated approach for steerable guidewire navigation within vessels. In this letter, we utilize fluoroscopic images to fully reconstruct 3-D printed phantom vasculature models by using a shape-from-silhouette algorithm. The reconstruction is subsequently de-noised using a deep learning-based encoder-decoder network and morphological filtering. This volume is used to model the environment for guidewire traversal. Following this, we present a novel method to plan an optimal path for guidewire traversal in three-dimensional vascular models through the use of slice planes and a modified hybrid A-star algorithm. Finally, the developed reconstruction and planning approaches are applied to an ex vivo porcine aorta, and navigation is demonstrated through the use of a tendon-actuated CO axially A ligned ST eerable guidewire (COAST).
- 22 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (4) , 928-935
Toward Real-Time Pose Estimation of the Mitral Valve Robot Under C-Arm X-Ray Fluoroscopy
Mitral regurgitation (MR) is a condition caused by a deformity in the mitral valve leading to the backflow of blood into the left atrium. MR can be treated through a minimally invasive procedure and our lab is currently developing a robot that could potentially be used to treat MR. The robot would carry a clip that latches onto the valve’s leaflets and closes them to minimize leakage. The robot’s accurate localization is needed to navigate the clip to the leaflets successfully. This paper discusses algorithms used to track the clip’s position and orientation under real-time using C-arm fluoroscopy. The positions are found through a deep learning semantic segmentation framework and the pose is found by calculating its bending and rotational angles. The robot’s bending angle and the clip’s rotational angle is found through an equivalent ellipse algorithm and an SVM classifier, respectively, and were validated by comparing orientations obtained from an electromagnetic tracker. The bending angle calculation has an average error of 7.7° and the rotational angle calculation is 76% for classifying them into five classes. Execution times are within 100ms and hence this could be a promising approach in real-time pose estimation.
- 22 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (4) , 928-935
Toward Real-Time Pose Estimation of the Mitral Valve Robot Under C-Arm X-Ray Fluoroscopy
Mitral regurgitation (MR) is a condition caused by a deformity in the mitral valve leading to the backflow of blood into the left atrium. MR can be treated through a minimally invasive procedure and our lab is currently developing a robot that could potentially be used to treat MR. The robot would carry a clip that latches onto the valve’s leaflets and closes them to minimize leakage. The robot’s accurate localization is needed to navigate the clip to the leaflets successfully. This paper discusses algorithms used to track the clip’s position and orientation under real-time using C-arm fluoroscopy. The positions are found through a deep learning semantic segmentation framework and the pose is found by calculating its bending and rotational angles. The robot’s bending angle and the clip’s rotational angle is found through an equivalent ellipse algorithm and an SVM classifier, respectively, and were validated by comparing orientations obtained from an electromagnetic tracker. The bending angle calculation has an average error of 7.7° and the rotational angle calculation is 76% for classifying them into five classes. Execution times are within 100ms and hence this could be a promising approach in real-time pose estimation.