Haymanot Takele Mekonnen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haymanot Takele Mekonnen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Abyot Yassab Nega
Department of Mechanical Engineering, School of Mechanical and Chemical Engineering, Institute of Technology, Woldia University, Woldia, Ethiopia
1 shared publication - Adugnaw Ayalew Bekele
Department of Mechanical Engineering, School of Mechanical and Chemical Engineering, Institute of Technology, Woldia University, Woldia, Ethiopia
1 shared publication - Ayodeji Olalekan Salau
Department of Electrical/Electronics and Computer Engineering, Afe Babalola University
1 shared publication - Belete Sirhabizu
Department of Mechanical Engineering, College of Engineering, Addis Ababa Science and Technology University, Addis Ababa P.O. Box 16417, Ethiopia
1 shared publication
Latest Publications
- Open Access
- 26 September 2022
- Published by Wiley in Scientific Programming
- Vol. 2022, 1-11
Towards the Optimal Performance of Washing Machines Using Fuzzy Logic
Washing machines (WMs) are common household appliances that help to save time and effort used in brushing and washing clothes. It is a common practice to use manually operated WMs, and based on their uses, WMs are classified into top and front open cloth washing machines, which operate based on an automatic control mechanism. In this paper, we present the design and simulation of an Arduino fuzzy logic-based WM control system, with an emphasis on improvement in its operating algorithm. Simulations were performed to determine the optimal time the WM takes to wash clothes, the maximum number of clothes the WM can wash per time, the acceptable dirtiness level of cloths, and the type of clothes that the machine can wash. The number of clothes to be washed, the degree of dirtiness, and the type of clothes govern the fuzzy logic control process adopted by the WM. The output voltage of the WM varies as the degree of dirtiness of the water varies from 0 to 1.95 V for very dirty water output from washed clothes and varies from 4 to 4.89 V for low-contaminated water. Another constraint considered was the load current, which increased as the number of clothes increased. The WM’s operation time is determined by the amount of voltage and load current used during its operation. As a result, the control of the WM is dependent on the dirtiness level of the clothes and the amount of load.
- 26 September 2022
- Published by Wiley in Scientific Programming
- Vol. 2022, 1-11
Open AccessTowards the Optimal Performance of Washing Machines Using Fuzzy Logic
Washing machines (WMs) are common household appliances that help to save time and effort used in brushing and washing clothes. It is a common practice to use manually operated WMs, and based on their uses, WMs are classified into top and front open cloth washing machines, which operate based on an automatic control mechanism. In this paper, we present the design and simulation of an Arduino fuzzy logic-based WM control system, with an emphasis on improvement in its operating algorithm. Simulations were performed to determine the optimal time the WM takes to wash clothes, the maximum number of clothes the WM can wash per time, the acceptable dirtiness level of cloths, and the type of clothes that the machine can wash. The number of clothes to be washed, the degree of dirtiness, and the type of clothes govern the fuzzy logic control process adopted by the WM. The output voltage of the WM varies as the degree of dirtiness of the water varies from 0 to 1.95 V for very dirty water output from washed clothes and varies from 4 to 4.89 V for low-contaminated water. Another constraint considered was the load current, which increased as the number of clothes increased. The WM’s operation time is determined by the amount of voltage and load current used during its operation. As a result, the control of the WM is dependent on the dirtiness level of the clothes and the amount of load.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Mitigating the Adverse Impact of Distributed Generation for the Protection of Distribution Networks
Integration of Distributed Generation (DG) generate problems for the protection of Distribution Networks (DNs) in power systems. When DG is integrated into a power distribution system (DS), the radial nature of the network is altered and the power starts to flow in a reverse direction. In addition to the reverse flow of power, the DG upsurges the fault current level which affects the existing time intermission coordination of the protective overcurrent relay. This study proposes a reverse power relay (RPR) and Fault Current Limiter (FCL) to mitigate the fault current level and reverse power flow in a Distribution Network (DN) by the use of DG. The FCL works only as unidirectional fault current limiter (UFCL) by restricting the flow of fault current that occurs in the main grid (MG) of the DG. However, FCLs can protect the flow of fault currents from the MG by affecting the operational flexibility and reliability of the DG. To overcome the flow of fault current of the DG, this study proposes RPR to monitor the power flow to the DG. Collectively the study focuses on the protection of radial DS by using RPR and UFCL. The analysis and the modeling was conducted on the 15KV DN of the radial feeder in Debre Markos DN. The 3Φ fault analysis (which is severe than others) was performed to validate the protection capability of the mitigation techniques which were proposed in this study.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessMitigating the Adverse Impact of Distributed Generation for the Protection of Distribution Networks
Integration of Distributed Generation (DG) generate problems for the protection of Distribution Networks (DNs) in power systems. When DG is integrated into a power distribution system (DS), the radial nature of the network is altered and the power starts to flow in a reverse direction. In addition to the reverse flow of power, the DG upsurges the fault current level which affects the existing time intermission coordination of the protective overcurrent relay. This study proposes a reverse power relay (RPR) and Fault Current Limiter (FCL) to mitigate the fault current level and reverse power flow in a Distribution Network (DN) by the use of DG. The FCL works only as unidirectional fault current limiter (UFCL) by restricting the flow of fault current that occurs in the main grid (MG) of the DG. However, FCLs can protect the flow of fault currents from the MG by affecting the operational flexibility and reliability of the DG. To overcome the flow of fault current of the DG, this study proposes RPR to monitor the power flow to the DG. Collectively the study focuses on the protection of radial DS by using RPR and UFCL. The analysis and the modeling was conducted on the 15KV DN of the radial feeder in Debre Markos DN. The 3Φ fault analysis (which is severe than others) was performed to validate the protection capability of the mitigation techniques which were proposed in this study.
- Open Access
- 9 November 2021
- Published by Springer Nature in Research Square
Increment of Fault Current due to integration of Distributed Generation and its impact on Distribution Network Protection
BackgroundOne of the new technologies in generating power near the distribution system is called distributed generation which has supportive and destructive characteristics to the power system protection. One of the destructive characteristics of distributed generation is increasing the level of fault current to the protective equipment of the power system. In addition to increment of fault, it also alters the radial nature of the power distribution system and cause the power bidirectional rather than unidirectional. Integration of distributed generation to the distribution network causes increment of fault current effect, reliability drop, and affects security of protection system. The level of failure of protection be contingent on type, size, location and number of distributed generation. This fault current can cause a great damage to the electrical equipment with the miss operations of protective devices. The main aim of this paper is analysis of the fault current level to the protection of distribution network due to the integration of distributed generation which concerns on solar distributed generation, wind distributed generation and combination of solar and wind distributed generations at a time. This paper conducts the analysis for the increment of fault current by the integration of distributed generation and its impact on distribution network protection. ResultsThe analysis and the modeling are conducted on the 15KV distribution network of the radial feeder in Debre Markos town. This paper has covered the ling to ground, line to line and three phase fault analysis and their impact on the protection of distribution system for the wind and solar distributed generation types. After the integration of the distributed generation the fault current is increased by 0.529KA for three phase, 0.74KA for line to ground, 0.467KA for line to line and 0.523KA for line to line to ground. ConclusionsThis paper confirms designing distribution network without forecasting the future demand of electric power users give the protection equipment additional requirement. As the result, the fault current after the integration of distributed generation to the distribution network have great value in terms of power system protection.
- 9 November 2021
- Published by Springer Nature in Research Square
Open AccessIncrement of Fault Current due to integration of Distributed Generation and its impact on Distribution Network Protection
BackgroundOne of the new technologies in generating power near the distribution system is called distributed generation which has supportive and destructive characteristics to the power system protection. One of the destructive characteristics of distributed generation is increasing the level of fault current to the protective equipment of the power system. In addition to increment of fault, it also alters the radial nature of the power distribution system and cause the power bidirectional rather than unidirectional. Integration of distributed generation to the distribution network causes increment of fault current effect, reliability drop, and affects security of protection system. The level of failure of protection be contingent on type, size, location and number of distributed generation. This fault current can cause a great damage to the electrical equipment with the miss operations of protective devices. The main aim of this paper is analysis of the fault current level to the protection of distribution network due to the integration of distributed generation which concerns on solar distributed generation, wind distributed generation and combination of solar and wind distributed generations at a time. This paper conducts the analysis for the increment of fault current by the integration of distributed generation and its impact on distribution network protection. ResultsThe analysis and the modeling are conducted on the 15KV distribution network of the radial feeder in Debre Markos town. This paper has covered the ling to ground, line to line and three phase fault analysis and their impact on the protection of distribution system for the wind and solar distributed generation types. After the integration of the distributed generation the fault current is increased by 0.529KA for three phase, 0.74KA for line to ground, 0.467KA for line to line and 0.523KA for line to line to ground. ConclusionsThis paper confirms designing distribution network without forecasting the future demand of electric power users give the protection equipment additional requirement. As the result, the fault current after the integration of distributed generation to the distribution network have great value in terms of power system protection.