Chao Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chao Ding has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Bin Liu
Faculty of Eletrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication - Chengcheng Cheng
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710100, China
1 shared publication - Feng Xu
State Grid Zhejiang Electric Power Research Institute, Hangzhou 310014, China
1 shared publication - Jiangang Bi
China Electric Power Research Institute
1 shared publication - Jingyuan Yin
Chinese Academy of Sciences
1 shared publication - Lianhui Ning
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication
Latest Publications
- Open Access
- 30 April 2026
- Published by MDPI AG in Electronics
- Vol. 15 (9) , 1895
Virtual Inertia and Frequency Control of Flexible Fractional Frequency Offshore Wind Power System Based on Modular Multilevel Matrix Converter
With the rapid development of offshore wind power, the fractional frequency offshore wind power system based on the modular multilevel matrix converter (M3C) faces severe frequency stability challenges due to the reduced inertia under high wind power penetration. This paper focuses on its frequency control and proposes a set of coordinated strategies. Modified frequency regulation schemes for wind turbines (WTs) under different operating states avoid secondary frequency drop (SFD) and accelerate rotor speed recovery. A coordinated power allocation strategy combining energy storage (ES) and automatic generation control (AGC) suppresses wind-induced power fluctuations, with a reducing pitch angle variation method to extend WTs’ life. Meanwhile, an adaptive virtual inertia control strategy for M3C enhances sustained inertia support. A coordinated frequency control scheme between wind farm, M3C, and ES is further constructed to achieve faster and better frequency stabilization under wind and load variations. Simulation results under a 10.5 MW load disturbance show that, compared with the uncontrolled scheme, the proposed scheme raises the frequency nadir from 49.01 Hz to 49.67 Hz, limits the maximum rate of change of frequency (ROCOF) to 0.583 Hz/s with a 49.8% reduction, fully eliminates SFD, and provides theoretical support for the stable grid integration of fractional frequency offshore wind power.
- 30 April 2026
- Published by MDPI AG in Electronics
- Vol. 15 (9) , 1895
Open AccessVirtual Inertia and Frequency Control of Flexible Fractional Frequency Offshore Wind Power System Based on Modular Multilevel Matrix Converter
With the rapid development of offshore wind power, the fractional frequency offshore wind power system based on the modular multilevel matrix converter (M3C) faces severe frequency stability challenges due to the reduced inertia under high wind power penetration. This paper focuses on its frequency control and proposes a set of coordinated strategies. Modified frequency regulation schemes for wind turbines (WTs) under different operating states avoid secondary frequency drop (SFD) and accelerate rotor speed recovery. A coordinated power allocation strategy combining energy storage (ES) and automatic generation control (AGC) suppresses wind-induced power fluctuations, with a reducing pitch angle variation method to extend WTs’ life. Meanwhile, an adaptive virtual inertia control strategy for M3C enhances sustained inertia support. A coordinated frequency control scheme between wind farm, M3C, and ES is further constructed to achieve faster and better frequency stabilization under wind and load variations. Simulation results under a 10.5 MW load disturbance show that, compared with the uncontrolled scheme, the proposed scheme raises the frequency nadir from 49.01 Hz to 49.67 Hz, limits the maximum rate of change of frequency (ROCOF) to 0.583 Hz/s with a 49.8% reduction, fully eliminates SFD, and provides theoretical support for the stable grid integration of fractional frequency offshore wind power.
- Open Access
Frequency Dependence of Air Breakdown and Investigation of Its Electro-Optical Characteristics
With the expanding frequency range of power equipment, understanding the frequency-dependent insulation performance of air becomes crucial. To address this, this paper establishes an integrated electrical–optical measurement platform for air breakdown to study the variation patterns of electrical and spectral characteristics of air breakdown at different frequencies. The effects and underlying mechanisms of different frequencies (20 Hz, 50 Hz, and 1 kHz) on the breakdown voltage are explored. Experimental results indicate that the air breakdown voltage increases with frequency as follows: from 17.7 kV at 20 Hz to 18.0 kV at 50 Hz (1.7% increase) and further to 18.9 kV at 1 kHz (5.0% increase from 50 Hz), representing a total increase of 6.8% across the 20 Hz to 1 kHz range. Regarding spectral characteristics, the spectral line intensity enhances with an increase in frequency. Compared to 20 Hz and 50 Hz, the spectral lines of nitrogen ions and oxygen ions become distinctly visible at 1 kHz, the Stark broadening phenomenon intensifies, and transitions from higher vibrational energy levels are enhanced relative to those from lower levels. Analysis via the Boltzmann plot method reveals a negative correlation between electron temperature (Te) and frequency, while the ionization degree (η) shows a positive correlation. Concurrently, the electron drift velocity (vd) increases with frequency, whereas the mean free path decreases (λ). Based on the parallel-plate capacitor model, the air breakdown under the experimental conditions of this study is dominated by collision ionization. As frequency increases, dielectric recovery slows down, and the memory effect strengthens. The interplay between these two competing factors leads to an increase in breakdown voltage with an increase in frequency within the 20 Hz to 1 kHz range. The findings of this study demonstrate that air breakdown exhibits significant frequency dependence, and its breakdown voltage shows statistical distribution characteristics (Weibull parameters) that vary with frequency. This article provides a reference basis for the design of sinusoidal air insulation in the 20 Hz to 1 kHz frequency range.
Open AccessFrequency Dependence of Air Breakdown and Investigation of Its Electro-Optical Characteristics
With the expanding frequency range of power equipment, understanding the frequency-dependent insulation performance of air becomes crucial. To address this, this paper establishes an integrated electrical–optical measurement platform for air breakdown to study the variation patterns of electrical and spectral characteristics of air breakdown at different frequencies. The effects and underlying mechanisms of different frequencies (20 Hz, 50 Hz, and 1 kHz) on the breakdown voltage are explored. Experimental results indicate that the air breakdown voltage increases with frequency as follows: from 17.7 kV at 20 Hz to 18.0 kV at 50 Hz (1.7% increase) and further to 18.9 kV at 1 kHz (5.0% increase from 50 Hz), representing a total increase of 6.8% across the 20 Hz to 1 kHz range. Regarding spectral characteristics, the spectral line intensity enhances with an increase in frequency. Compared to 20 Hz and 50 Hz, the spectral lines of nitrogen ions and oxygen ions become distinctly visible at 1 kHz, the Stark broadening phenomenon intensifies, and transitions from higher vibrational energy levels are enhanced relative to those from lower levels. Analysis via the Boltzmann plot method reveals a negative correlation between electron temperature (Te) and frequency, while the ionization degree (η) shows a positive correlation. Concurrently, the electron drift velocity (vd) increases with frequency, whereas the mean free path decreases (λ). Based on the parallel-plate capacitor model, the air breakdown under the experimental conditions of this study is dominated by collision ionization. As frequency increases, dielectric recovery slows down, and the memory effect strengthens. The interplay between these two competing factors leads to an increase in breakdown voltage with an increase in frequency within the 20 Hz to 1 kHz range. The findings of this study demonstrate that air breakdown exhibits significant frequency dependence, and its breakdown voltage shows statistical distribution characteristics (Weibull parameters) that vary with frequency. This article provides a reference basis for the design of sinusoidal air insulation in the 20 Hz to 1 kHz frequency range.
- Open Access
Flexible Low-Carbon Optimal Dispatch of Honeycombed Active Distribution Network
Microgrids have a strong ability to generate local power and consume renewable energy, which can solve the problems of power supply shortages and greenhouse gas emissions created in the process of social development. The honeycombed active distribution network (HADN) can flexibly, independently, and interconnectedly operate microgrids through power exchange stations, so appropriate HADN dispatch can produce increased low-carbon benefits than general microgrids. In this study, we first designed a model for optimizing HADN with the lowest carbon emission as the target, then we introduced the concept of carbon emission flow into the optimization process to determine the carbon emission level of each element. Finally, we illustrated and verified the proposed model by a HADN composed of three microgrids. The optimization results of the case study showed that by scheduling the DGs within the microgrids, the total carbon emissions of the system were reduced from 123,328.1 to 117,688 kg CO; the system with a HADN structure was able to produce only 110,958 kg CO and effectively reduce carbon emissions by 10%, which proved that HADN can be scheduled with high flexibility and provides increased low-carbon performance through the proposed optimization dispatch method.Open AccessFlexible Low-Carbon Optimal Dispatch of Honeycombed Active Distribution Network
Microgrids have a strong ability to generate local power and consume renewable energy, which can solve the problems of power supply shortages and greenhouse gas emissions created in the process of social development. The honeycombed active distribution network (HADN) can flexibly, independently, and interconnectedly operate microgrids through power exchange stations, so appropriate HADN dispatch can produce increased low-carbon benefits than general microgrids. In this study, we first designed a model for optimizing HADN with the lowest carbon emission as the target, then we introduced the concept of carbon emission flow into the optimization process to determine the carbon emission level of each element. Finally, we illustrated and verified the proposed model by a HADN composed of three microgrids. The optimization results of the case study showed that by scheduling the DGs within the microgrids, the total carbon emissions of the system were reduced from 123,328.1 to 117,688 kg CO; the system with a HADN structure was able to produce only 110,958 kg CO and effectively reduce carbon emissions by 10%, which proved that HADN can be scheduled with high flexibility and provides increased low-carbon performance through the proposed optimization dispatch method.