YLYaran Li

Yaran Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yaran Li has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optical processing strategies for microimaging small-aperture Wolter mirrors

    by Yaran Li

    The Wolter microscope, characterized by its high spatial resolution, large geometric solid angle, and broadband achromatic correction, serves as an ideal initial configuration for the next generation of X-ray imaging diagnostic techniques. Nevertheless, the development of small-aperture Wolter mirrors encounters significant challenges, which primarily hinder their widespread application. This article presents a design approach for micro-imaging small-aperture Wolter microscopes, considering both optical design principles and mirror preparation techniques. It reveals the intricate trade-off relationships among spatial resolution, collection efficiency, and the feasibility of optical processing. By effectively integrating optical principles with manufacturing practices, a staged development roadmap for small-aperture Wolter mirrors is proposed. Through technological convergence, the electroforming nickel preparation process can be gradually mastered. This article provides technical insights that can guide the design and development of high-quality hard X-ray Wolter microscopes.

  • Optical considerations and ray tracing simulation of an open-type Wolter microscope for implosion imaging diagnostics

    by Yaran Li, Chenglong Jiang

    Controlled nuclear fusion through laser Inertial Confinement Fusion (ICF) is currently being developed. It is of great significance for energy security, high energy physics and national defense, etc. High-precision x-ray microscopic imaging techniques have become the key to revealing material phenomena and laws under extreme conditions. This paper proposes an open-type Wolter microscope configuration. By utilizing the configuration, a number of modern polishing techniques can be utilized and a balance between imaging performance and the feasibility of optical processing can be achieved. The original enclosed and inner Wolter mirror surfaces have been changed to unclosed outer surfaces. The configuration is characterized by high spatial resolution, large depth of field, and high throughput, among other features. And these characteristics are urgently needed in high-precision x-ray imaging diagnostics. The technical scheme and optical considerations of the configuration are detailed. Ray tracing simulation is used to design key optical parameters and evaluate system imaging performance. In addition, this configuration has potential for various diagnostic purposes, including sub-micron spatial resolution imaging, high-energy high-throughput imaging, multi-color and multi-channel imaging, and more.

  • Design and preliminary evaluation of a multi-channel multi-energy point integrated Wolter microscope

    by Yaran Li, Huanzhen Ma, Yifan Chen, Zhengda Li, Dongfang Wang

    In inertial confinement fusion, high-precision x-ray imaging is crucial for understanding the states of matter under extreme conditions. To observe the target asymmetry during compression, multiple imaging spots with varying energy responses are necessary. However, integrating multiple imaging channels in a grazing incidence x-ray imaging scheme is challenging, and there is an urgent need for effective combination of multi-color and high-throughput diagnostics. This study presents a design method for a multi-channel integrated Wolter microscope with high spatial resolution, wide-band response, and high throughput. The basic optical configuration, adjustment method, and multi-channel integration scheme are discussed in detail. A 10 keV-class three-channel integrated Wolter microscope is proposed for verification, with an estimated spatial resolution better than 4.0 µm in a field of view of ±500µm. The peak response efficiencies for each imaging channel are calculated as 5.2×10−5sr, 8.6×10−5sr, and 2.2×10−4sr, respectively.

  • Basic principles and optical system design of 17.48 keV high-throughput modified Wolter x-ray microscope

    by Yaran Li, Wenjie Li, Liang Chen, Huanzhen Ma, Xinye Xu, Jie Xu, Xin Wang, Baozhong Mu

    High-precision x-ray imaging diagnostics of hotspot at the stagnation stage are essential for regulating implosion asymmetry and retrieving physical implosion parameters. With regard to 10–20 keV energy band imaging, existing diagnostic instruments such as Kirkpatrick–Baez microscopes and pinhole cameras are insufficient in terms of spatial resolution and collection efficiency. The situation is even worse when high-speed, time-resolved imaging diagnostics are performed by coupling framing cameras or line-of-sight imagers. This article presents the basic principles and optical system design of a 17.48 keV modified Wolter x-ray microscope, to resolve the problems encountered in high-energy imaging diagnostics. The proposed optical configuration offers a better spatial resolution, greater depth of field, and preliminary compliance with the requirements of high precision optical processing techniques. The spatial resolution is better than 1 µm in a field range ±150 µm, and is better than 3 µm in a total field of view ∼408 µm in diameter. The geometric solid angle is calculated as 3.0 × 10−5 sr and is estimated to be 1.2 × 10−6 sr, considering the reflectivity of the double mirrors. The proposed microscope is expected to effectively improve spatial resolution and signal-to-noise ratio for high-energy imaging diagnostics.


  • Note: New method for high-space-resolving hotspot electron temperature measurements on Shenguang-III prototype

    by Kuan Ren, Zhurong Cao, Jianjun Dong, Baozhong Mu, Qing Xie, Yaran Li, Jiyan Zhang, Tianxuan Huang, Jiamin Yang, Feng Wang, et al.

    High-space-resolving information of hotspot electron temperature is a foundation for further research on physical processes of implosion in inertial confinement fusion. This work proposed a novel high-space-resolving electron temperature detector, which is based on the bremsstrahlung radiation mechanism of the implosion hotspot and uses two-channel Kirkpatrick–Baez microscopes. In this novel detector, an optical quasi-coaxis method was used to eliminate the strong impact of the view field difference on the high space resolution and correctness of the electron temperature diagnosis, and a compound KB microscope method was proposed to reduce the number of spherical reflectors and save space.


  • Direct intensity calibration of X-ray grazing-incidence microscopes with home-lab source

    by Yaran Li, Qing Xie, Zhiqiang Chen, Qiuqi Xin, Xin Wang, Baozhong Mu, Zhanshan Wang, Shenye Liu, Yongkun Ding

    Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ∼95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ∼6.0%.