Peter H Tomlins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter H Tomlins has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
A C Shortall
University of Birmingham
1 shared publication- Ana Raquel Benetti
Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
1 shared publication - Bon-Kwon Koo
Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul National University of College of Medicine, Seoul, South Korea
1 shared publication - Chang-Wook Nam
Department of Medicine, Keimyung University Dongsan Medical Center, Daegu, Korea
1 shared publication Charalambos Antoniades
Acute Multidisciplinary Imaging and Interventional Centre, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
1 shared publication- Dan L. Bader
University of Southampton
1 shared publication
Latest Publications
- 1 November 2024
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 19 (1) , 32-39
Association of coronary inflammation with plaque vulnerability and fractional flow reserve in coronary artery disease
- 1 November 2024
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 19 (1) , 32-39
Association of coronary inflammation with plaque vulnerability and fractional flow reserve in coronary artery disease
- Open Access
- 29 September 2022
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 9 (1) , 84-91
Optical coherence tomography systems for evaluation of marginal and internal fit of ceramic reconstructions
To evaluate the marginal and internal fit of lithium disilicate and zirconia crowns using two optical coherence tomography (OCT) systems in order to estimate inter-system variations.Ten lithium dis...
- 29 September 2022
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 9 (1) , 84-91
Open AccessOptical coherence tomography systems for evaluation of marginal and internal fit of ceramic reconstructions
To evaluate the marginal and internal fit of lithium disilicate and zirconia crowns using two optical coherence tomography (OCT) systems in order to estimate inter-system variations.Ten lithium dis...
- 21 September 2012
- Published by Springer Nature in Lasers in Medical Science
- Vol. 28 (5) , 1249-1255
Quantitative optical coherence tomography of fluid-filled oral mucosal lesions
The decision of selecting the most representative site for the biopsy of fluid-filled lesions can be difficult. This may be attributed to the poor delineation of the correct lesional site by clinical observation alone. In this study, optical coherence tomography is used to quantify the contrast between solid- and fluid-filled lesions by measuring the light intensity change at the tissue–fluid interface (intensity drop). This parameter was measured from sequential axial scans (n ≈ 106 per sample) of 3D optical coherence tomography (OCT) datasets from control tissues (n = 14) and fluid-filled lesions (n = 7) and displayed as a 2D-scaled intensity drop (SID) image. The results of the SID image allowed for discrimination, characterisation and extent of a fluid filled region. The differentiation of normal and fluid-filled areas using individual SID values yielded both a sensitivity and specificity of approximately 80 %. OCT complemented by SID analysis provides a potential in vivo clinical tool that would enable non-invasive objective visualisation of the oral mucosa.
- 21 September 2012
- Published by Springer Nature in Lasers in Medical Science
- Vol. 28 (5) , 1249-1255
Quantitative optical coherence tomography of fluid-filled oral mucosal lesions
The decision of selecting the most representative site for the biopsy of fluid-filled lesions can be difficult. This may be attributed to the poor delineation of the correct lesional site by clinical observation alone. In this study, optical coherence tomography is used to quantify the contrast between solid- and fluid-filled lesions by measuring the light intensity change at the tissue–fluid interface (intensity drop). This parameter was measured from sequential axial scans (n ≈ 106 per sample) of 3D optical coherence tomography (OCT) datasets from control tissues (n = 14) and fluid-filled lesions (n = 7) and displayed as a 2D-scaled intensity drop (SID) image. The results of the SID image allowed for discrimination, characterisation and extent of a fluid filled region. The differentiation of normal and fluid-filled areas using individual SID values yielded both a sensitivity and specificity of approximately 80 %. OCT complemented by SID analysis provides a potential in vivo clinical tool that would enable non-invasive objective visualisation of the oral mucosa.
- 8 April 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (9) , 2855-2871
The modulation transfer function of an optical coherence tomography imaging system in turbid media
In this paper we describe measurements of the contrast transfer function, modulation transfer function and point-spread function of an optical coherence tomography (OCT) imaging system through scattering layers having a dimension-less scattering depth over the range 0.2-6.9. The results were found to be insensitive to scattering density, indicating that these measurement parameters alone do not well characterize the practical imaging ability of an OCT instrument. Attenuation and increased noise floor due to optical scattering were found to be the primary imaging limit and the effect of multiple scattering on OCT resolution was negligible.
- 8 April 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (9) , 2855-2871
The modulation transfer function of an optical coherence tomography imaging system in turbid media
In this paper we describe measurements of the contrast transfer function, modulation transfer function and point-spread function of an optical coherence tomography (OCT) imaging system through scattering layers having a dimension-less scattering depth over the range 0.2-6.9. The results were found to be insensitive to scattering density, indicating that these measurement parameters alone do not well characterize the practical imaging ability of an OCT instrument. Attenuation and increased noise floor due to optical scattering were found to be the primary imaging limit and the effect of multiple scattering on OCT resolution was negligible.
- 7 February 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6843, 68430D
Dynamic cure measurement of dental polymer composites using optical coherence tomography
Dental amalgam is being increasingly replaced by Light-activated resin-based dental composites. However, these materials are limited by inefficient setting reactions as a function of depth, constraining the maximum extent of cure and reducing biocompatibility. In this paper we demonstrate a novel metrological tool for dynamic monitoring of refractive index and thickness change through curing resins using spectral-domain optical coherence tomography. We present real-time measurements from pre- to post-cure of a series of un-filled bisphenol-A diglycidyl ether dimethacrylate (bisGMA) and triethylene glycol dimethacrylate (TEGDMA) resins with different inhibitor concentrations. Our results demonstrate that refractive index measurements are sensitive to the extent of cure of such resins and that the inhibitor concentration strongly affects the cure dynamics and final extent of cure.
- 7 February 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6843, 68430D
Dynamic cure measurement of dental polymer composites using optical coherence tomography
Dental amalgam is being increasingly replaced by Light-activated resin-based dental composites. However, these materials are limited by inefficient setting reactions as a function of depth, constraining the maximum extent of cure and reducing biocompatibility. In this paper we demonstrate a novel metrological tool for dynamic monitoring of refractive index and thickness change through curing resins using spectral-domain optical coherence tomography. We present real-time measurements from pre- to post-cure of a series of un-filled bisphenol-A diglycidyl ether dimethacrylate (bisGMA) and triethylene glycol dimethacrylate (TEGDMA) resins with different inhibitor concentrations. Our results demonstrate that refractive index measurements are sensitive to the extent of cure of such resins and that the inhibitor concentration strongly affects the cure dynamics and final extent of cure.