Guozhong Zhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Guozhong Zhan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Haiming Shao
National Institute of Metrology, Beijing, China
2 shared publications - Lei Lai
Division of Electron and Electricity Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, China
2 shared publications - Liren Zhou
Division of Electron and Electricity Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, China
2 shared publications - Yang Pan
Division of Electron and Electricity Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, China
2 shared publications - Feng Xu
Division of Electron and Electricity Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, China
1 shared publication - Ji Geng
Division of Electron and Electricity Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, China
1 shared publication
Latest Publications
- 28 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Multifunctional Wideband Digital Sampling System for the Calibration of Conventional Transformers and Electronic Transformers
The calibration system for conventional instrument transformers does not apply to the electronic transformers (ECT/EVT) that meet the requirements of the IEC61850-9-2 digital substation protocol. In this paper, a calibration system for both electronic transformers and conventional transformers based on sampling techniques using digital multimeters (DMMs) is reported. This calibration system uses conventional instrument transformers as references, non-inductance shunts for current to voltage (I/V) conversion, and an inductive voltage divider (IVD) for secondary attenuation. Having received the pulse-per-second (PPS) signal from the merging unit (MU), a function generator burst pulses to trigger the DMMs for synchronous sampling. An improved quasi-synchronization algorithm is adopted as windowed discrete Fourier transform (DFT) for ratio and phase displacement calculation. This paper analyses the uncertainty contributions and makes corrections to the calibration results. Uncertainty evaluation under power frequency proposed for the calibration of CT up to 10kA is estimated to be within 10ppm and 15μrad for ratio and phase displacement, 25ppm and 30μrad for voltage transformers up to 500kV/√3 with a coverage factor k =2.
- 28 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Multifunctional Wideband Digital Sampling System for the Calibration of Conventional Transformers and Electronic Transformers
The calibration system for conventional instrument transformers does not apply to the electronic transformers (ECT/EVT) that meet the requirements of the IEC61850-9-2 digital substation protocol. In this paper, a calibration system for both electronic transformers and conventional transformers based on sampling techniques using digital multimeters (DMMs) is reported. This calibration system uses conventional instrument transformers as references, non-inductance shunts for current to voltage (I/V) conversion, and an inductive voltage divider (IVD) for secondary attenuation. Having received the pulse-per-second (PPS) signal from the merging unit (MU), a function generator burst pulses to trigger the DMMs for synchronous sampling. An improved quasi-synchronization algorithm is adopted as windowed discrete Fourier transform (DFT) for ratio and phase displacement calculation. This paper analyses the uncertainty contributions and makes corrections to the calibration results. Uncertainty evaluation under power frequency proposed for the calibration of CT up to 10kA is estimated to be within 10ppm and 15μrad for ratio and phase displacement, 25ppm and 30μrad for voltage transformers up to 500kV/√3 with a coverage factor k =2.
- 30 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-7
Investigation on the Voltage Dependence of Compressed-Gas-Insulated Capacitors up to 400 kV by Improved Voltage-Doubling Method
This paper presents a recent improvement in the measurement of voltage dependence of compressed gas capacitors up to 400 kV using the voltage doubling method. Two identical 10nF high-voltage capacitors in series are employed to generate voltage-doubling operating points and this proved to be effective in providing consistent harmonic content for voltages. A commercial ground current comparator bridge is used to compare the capacitor under test with a reference capacitor at equal voltage and double voltage, respectively. In order to accurately determine the ratio of the voltage applied across the reference capacitor and the capacitor under test in the voltage doubling state, the other current comparator bridge with floating remote transmission function is developed in this paper to monitor the voltage ratio of the doubling voltage. The two current comparator bridges perform measurement process simultaneously without prior knowledge of the voltage coefficient of the reference capacitor. In this paper, the influence of the working state of the floating current comparator bridge on the measurement is determined by an inductive voltage divider. The experiment results show that the expanded uncertainty of the proposed method for measuring the voltage coefficient of capacitance and loss of 400 kV high-voltage capacitors is estimated to be about 5 ppm.
- 30 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-7
Investigation on the Voltage Dependence of Compressed-Gas-Insulated Capacitors up to 400 kV by Improved Voltage-Doubling Method
This paper presents a recent improvement in the measurement of voltage dependence of compressed gas capacitors up to 400 kV using the voltage doubling method. Two identical 10nF high-voltage capacitors in series are employed to generate voltage-doubling operating points and this proved to be effective in providing consistent harmonic content for voltages. A commercial ground current comparator bridge is used to compare the capacitor under test with a reference capacitor at equal voltage and double voltage, respectively. In order to accurately determine the ratio of the voltage applied across the reference capacitor and the capacitor under test in the voltage doubling state, the other current comparator bridge with floating remote transmission function is developed in this paper to monitor the voltage ratio of the doubling voltage. The two current comparator bridges perform measurement process simultaneously without prior knowledge of the voltage coefficient of the reference capacitor. In this paper, the influence of the working state of the floating current comparator bridge on the measurement is determined by an inductive voltage divider. The experiment results show that the expanded uncertainty of the proposed method for measuring the voltage coefficient of capacitance and loss of 400 kV high-voltage capacitors is estimated to be about 5 ppm.