Hitoshi Wakama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hitoshi Wakama has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Shuhei Otsuki
Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Osaka, Japan
10 shared publications - Yoshinori Okamoto
Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Japan
10 shared publications - Masashi Neo
Department of Pharmacy, Osaka Medical and Pharmaceutical University Hospital, Takatsuki, Japan
7 shared publications - Junya Matsuyama
Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Japan
4 shared publications - Takashi Ishitani
Osaka Medical and Pharmaceutical University, Takatsuki, Japan
3 shared publications Junya Matsuyama
Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Japan
2 shared publications
Latest Publications
- 21 November 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 509
A simple radiographic predictor for rapid progression of hip arthrosis: the sacro-femoral-pubic angle in the coronal plane
Introduction This study aimed to evaluate the association between coronal pelvic and sagittal spinal radiographic parameters and the rapid progression of hip arthrosis (RPHA). Materials and methods In this retrospective case–control study, 92 patients (92 hips) who underwent hip arthroplasty were analysed. RPHA was defined as ≥ two millimeters of femoral head collapse or ≥ 50% narrowing of the hip joint space within 12 months. Patients were classified into two groups: the study group (n = 29) and the control group (n = 63), which comprised patients without RPHA during a minimum follow-up period of 12 months before the operation. Linear regression and receiver operating characteristic (ROC) curve analyses were performed to identify radiographic predictors of RPHA. Results RPHA was significantly associated with lumbar lordosis (p = 0.001), pelvic tilt (p = 0.012), sacro-femoral-pubic angle (SFP; p = 0.003), and T1 pelvic angle (p < 0.001). The predictive accuracy of SFP, based on the area under the ROC curve, was statistically comparable to that of established sagittal alignment parameters (p > 0.05). Patients with SFP < 62° had a significantly higher prevalence of RPHA than those with SFP ≥ 62° (p = 0.007). Conclusions SFP, measurable from standard anteroposterior pelvic radiographs, may represent a simple and practical alternative to sagittal spinopelvic parameters for identifying radiographic features associated with RPHA.
- 21 November 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 509
A simple radiographic predictor for rapid progression of hip arthrosis: the sacro-femoral-pubic angle in the coronal plane
Introduction This study aimed to evaluate the association between coronal pelvic and sagittal spinal radiographic parameters and the rapid progression of hip arthrosis (RPHA). Materials and methods In this retrospective case–control study, 92 patients (92 hips) who underwent hip arthroplasty were analysed. RPHA was defined as ≥ two millimeters of femoral head collapse or ≥ 50% narrowing of the hip joint space within 12 months. Patients were classified into two groups: the study group (n = 29) and the control group (n = 63), which comprised patients without RPHA during a minimum follow-up period of 12 months before the operation. Linear regression and receiver operating characteristic (ROC) curve analyses were performed to identify radiographic predictors of RPHA. Results RPHA was significantly associated with lumbar lordosis (p = 0.001), pelvic tilt (p = 0.012), sacro-femoral-pubic angle (SFP; p = 0.003), and T1 pelvic angle (p < 0.001). The predictive accuracy of SFP, based on the area under the ROC curve, was statistically comparable to that of established sagittal alignment parameters (p > 0.05). Patients with SFP < 62° had a significantly higher prevalence of RPHA than those with SFP ≥ 62° (p = 0.007). Conclusions SFP, measurable from standard anteroposterior pelvic radiographs, may represent a simple and practical alternative to sagittal spinopelvic parameters for identifying radiographic features associated with RPHA.
- 10 November 2025
- Published by Springer Nature in European Spine Journal
- Vol. 35 (5) , 2849-2857
Radiographic and systemic predictors of persistent low back pain following total hip arthroplasty: roles of relative pelvic version and osteosarcopenia
Purpose This study aimed to assess the association of preoperative relative pelvic version (RPV, individualised pelvic incidence (PI)–based proportional parameter) and osteosarcopenia (coexisting osteoporosis and sarcopenia) with persistent low back pain (LBP) after total hip arthroplasty (THA). Methods We retrospectively reviewed 162 consecutive patients who underwent unilateral primary THA (mean follow-up, 24 months). Preoperative assessments included lateral standing radiographs for RPV (= sacral slope – [PI × 0.59 + 9]), lumbar dual-energy X-ray absorptiometry for bone density, and computed tomography–based cross-sectional area of the psoas muscle. The primary outcome was the achievement of the minimal clinically important difference (MCID) in the visual analogue scale score for LBP (VAS-LBP) at final follow-up. Multivariate logistic regression identified independent predictors. As a sensitivity analysis, a 1:1 propensity score–matched comparison (pelvic retroversion vs control) evaluated patient-reported outcomes. Results RPV < − 7° (P = 0.025), sarcopenia (P = 0.028), and osteoporosis (P = 0.044) were independently associated with failure to achieve MCID in LBP. The matched cohort confirmed worse VAS-LBP, Oswestry Disability Index, and patient satisfaction in the retroverted group (P < 0.05). Osteosarcopenia was also more frequent among affected patients (P < 0.001). Conclusions Preoperative RPV, a simple radiographic parameter, independently predicts persistent LBP after THA. Combined evaluation of RPV and osteosarcopenia may improve preoperative risk stratification and guide targeted perioperative management.
- 10 November 2025
- Published by Springer Nature in European Spine Journal
- Vol. 35 (5) , 2849-2857
Radiographic and systemic predictors of persistent low back pain following total hip arthroplasty: roles of relative pelvic version and osteosarcopenia
Purpose This study aimed to assess the association of preoperative relative pelvic version (RPV, individualised pelvic incidence (PI)–based proportional parameter) and osteosarcopenia (coexisting osteoporosis and sarcopenia) with persistent low back pain (LBP) after total hip arthroplasty (THA). Methods We retrospectively reviewed 162 consecutive patients who underwent unilateral primary THA (mean follow-up, 24 months). Preoperative assessments included lateral standing radiographs for RPV (= sacral slope – [PI × 0.59 + 9]), lumbar dual-energy X-ray absorptiometry for bone density, and computed tomography–based cross-sectional area of the psoas muscle. The primary outcome was the achievement of the minimal clinically important difference (MCID) in the visual analogue scale score for LBP (VAS-LBP) at final follow-up. Multivariate logistic regression identified independent predictors. As a sensitivity analysis, a 1:1 propensity score–matched comparison (pelvic retroversion vs control) evaluated patient-reported outcomes. Results RPV < − 7° (P = 0.025), sarcopenia (P = 0.028), and osteoporosis (P = 0.044) were independently associated with failure to achieve MCID in LBP. The matched cohort confirmed worse VAS-LBP, Oswestry Disability Index, and patient satisfaction in the retroverted group (P < 0.05). Osteosarcopenia was also more frequent among affected patients (P < 0.001). Conclusions Preoperative RPV, a simple radiographic parameter, independently predicts persistent LBP after THA. Combined evaluation of RPV and osteosarcopenia may improve preoperative risk stratification and guide targeted perioperative management.
- 4 November 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (4) , 1397-1408
Low‐constraint insert with a medial pivot design as a potential predictor of favourable outcomes in cruciate‐retaining total knee arthroplasty: A propensity score‐matched analysis
Purpose: The influence of polyethylene insert conformity on the outcomes of cruciate‐retaining (CR) total knee arthroplasty (TKA) with a medial pivot design remains uncertain. Therefore, this study aimed to evaluate the effects of polyethylene insert conformity in CR‐TKA on patient‐reported outcomes.Methods: The data of 255 knees (FINE Total Knee System) from 255 patients were retrospectively analysed to compare outcomes for high‐ or low‐constraint medial pivot inserts, as determined through historical controls, over an average follow‐up period of 2.2 years (range, 2.0–5.5 years). Multivariate logistic regression analysis was used to identify predictors of achieving the patient‐acceptable symptom state (PASS) for the Forgotten Joint Score‐12 (FJS‐12). Propensity score‐matched cohorts for age, sex, body mass index, Kellgren‐Lawrence grade, Charlson Comorbidity Index, knee flexion contracture, FJS‐12 and follow‐up duration were created for between‐group comparison (n = 50 in each group).Results: Low‐constraint insert (p = 0.031) and age (p = 0.043) were independent predictors of achieving the PASS for the FJS‐12 (>33, 153/255). After successful matching, compared to the high‐constraint insert, the low‐constraint insert improved patient satisfaction (p = 0.029 for pain on going up or downstairs, and p = 0.047 for the function of going upstairs) and increased the likelihood of achieving the minimal clinically important difference (p = 0.019) and PASS (p = 0.025) for the FJS‐12. A significant correlation was observed between the posterior tibial slope and the FJS‐12 in the low‐constraint insert group (p < 0.001), indicating that a greater posterior tibial slope was associated with better functional outcomes in this group.Conclusions: Compared with high‐constraint inserts, low‐constraint medial pivot inserts yielded higher functional outcomes and patient satisfaction. Therefore, insert conformity may play a crucial role in CR‐TKA outcomes.Level of Evidence: Level III.
- 4 November 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (4) , 1397-1408
Low‐constraint insert with a medial pivot design as a potential predictor of favourable outcomes in cruciate‐retaining total knee arthroplasty: A propensity score‐matched analysis
Purpose: The influence of polyethylene insert conformity on the outcomes of cruciate‐retaining (CR) total knee arthroplasty (TKA) with a medial pivot design remains uncertain. Therefore, this study aimed to evaluate the effects of polyethylene insert conformity in CR‐TKA on patient‐reported outcomes.Methods: The data of 255 knees (FINE Total Knee System) from 255 patients were retrospectively analysed to compare outcomes for high‐ or low‐constraint medial pivot inserts, as determined through historical controls, over an average follow‐up period of 2.2 years (range, 2.0–5.5 years). Multivariate logistic regression analysis was used to identify predictors of achieving the patient‐acceptable symptom state (PASS) for the Forgotten Joint Score‐12 (FJS‐12). Propensity score‐matched cohorts for age, sex, body mass index, Kellgren‐Lawrence grade, Charlson Comorbidity Index, knee flexion contracture, FJS‐12 and follow‐up duration were created for between‐group comparison (n = 50 in each group).Results: Low‐constraint insert (p = 0.031) and age (p = 0.043) were independent predictors of achieving the PASS for the FJS‐12 (>33, 153/255). After successful matching, compared to the high‐constraint insert, the low‐constraint insert improved patient satisfaction (p = 0.029 for pain on going up or downstairs, and p = 0.047 for the function of going upstairs) and increased the likelihood of achieving the minimal clinically important difference (p = 0.019) and PASS (p = 0.025) for the FJS‐12. A significant correlation was observed between the posterior tibial slope and the FJS‐12 in the low‐constraint insert group (p < 0.001), indicating that a greater posterior tibial slope was associated with better functional outcomes in this group.Conclusions: Compared with high‐constraint inserts, low‐constraint medial pivot inserts yielded higher functional outcomes and patient satisfaction. Therefore, insert conformity may play a crucial role in CR‐TKA outcomes.Level of Evidence: Level III.
- Open Access
- 19 April 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (4) , 246
Usefulness of Probing Sensor Device for Evaluating Meniscal Suture and Scaffold Implantation
Appropriate suture tension is a key factor in successful meniscal repair. This study aimed to clarify the appropriate value of meniscal stabilization with suture repair based on a probing procedure for healthy porcine menisci and a novel meniscal scaffold. After evaluating the reliability of the probing sensor, meniscal vertical tear and partial meniscectomy models were developed, in which suture repair and meniscal scaffold implantation were performed at suture intervals ranging between 20 and 2.5 mm. The residence forces at each interval were evaluated using a probing sensor. Moreover, a tensile test was conducted to evaluate the displacement and presence or absence of gaps. We found that normal and meniscal scaffolds should be fixed within 5 mm of suture interval. The probing residence forces required were at least 1.0 N for vertical tears and 3.0 N for meniscal scaffolds. These findings may be taken into consideration to reduce suture failure following meniscal tear repair and stabilizing meniscal scaffold fixation.
- 19 April 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (4) , 246
Open AccessUsefulness of Probing Sensor Device for Evaluating Meniscal Suture and Scaffold Implantation
Appropriate suture tension is a key factor in successful meniscal repair. This study aimed to clarify the appropriate value of meniscal stabilization with suture repair based on a probing procedure for healthy porcine menisci and a novel meniscal scaffold. After evaluating the reliability of the probing sensor, meniscal vertical tear and partial meniscectomy models were developed, in which suture repair and meniscal scaffold implantation were performed at suture intervals ranging between 20 and 2.5 mm. The residence forces at each interval were evaluated using a probing sensor. Moreover, a tensile test was conducted to evaluate the displacement and presence or absence of gaps. We found that normal and meniscal scaffolds should be fixed within 5 mm of suture interval. The probing residence forces required were at least 1.0 N for vertical tears and 3.0 N for meniscal scaffolds. These findings may be taken into consideration to reduce suture failure following meniscal tear repair and stabilizing meniscal scaffold fixation.
- 1 October 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (12) , 4452-4463
Clinical significance of relative pelvic version measurement as a predictor of low back pain after total hip arthroplasty
Purpose To evaluate the association between the preoperative global alignment and proportion (GAP) score and low back pain (LBP) after total hip arthroplasty (THA). Methods This was a retrospective case–control study of 200 patients who underwent primary unilateral THA for hip osteoarthritis. The following variables were compared between individuals with (n = 76) and without (n = 124) LBP after THA over a mean follow-up of 2 years: age, sex, GAP score, and patient-reported outcome measures. Logistic regression and receiver operating characteristic curve analyses were used to detect predictive factors. Results The following parameters were predictive of post-THA LBP: relative pelvic version (RPV) <−7° (odds ratio, 1.43; 95% confidence interval, 1.10–1.72; P = 0.032) and relative lumbar lordosis <−15° (odds ratio, 1.13; 95% confidence interval, 1.04–2.13; P = 0.041) preoperatively. Using an RPV cutoff value of − 7° (specificity 61/64 = 0.953; sensitivity 121/136 = 0.890), there were significant between-group differences in LBP visual analog scale (P = 0.020), Oswestry Disability Index (ODI, P = 0.014), EuroQol 5-Dimension (P = 0.027), Hip Disability and Osteoarthritis Outcome Score Joint Replacement (HOOS JR, P = 0.012), patient satisfaction (P = 0.024). There was clinically meaningful improvement for LBP visual analog scale (P = 0.001), ODI (P = 0.004), and HOOS JR (P < 0.001). The RPV before THA was correlated with HOOS JR (r = 0.773, P = 0.012) and ODI (r = − 0.602, P = 0.032) postoperatively. Conclusion Among the GAP score, a moderate-to-severe pelvic retroversion was significantly associated with LBP post-THA. The RPV measurement may be a useful predictor of THA outcome, which may influence patient satisfaction.
- 1 October 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (12) , 4452-4463
Clinical significance of relative pelvic version measurement as a predictor of low back pain after total hip arthroplasty
Purpose To evaluate the association between the preoperative global alignment and proportion (GAP) score and low back pain (LBP) after total hip arthroplasty (THA). Methods This was a retrospective case–control study of 200 patients who underwent primary unilateral THA for hip osteoarthritis. The following variables were compared between individuals with (n = 76) and without (n = 124) LBP after THA over a mean follow-up of 2 years: age, sex, GAP score, and patient-reported outcome measures. Logistic regression and receiver operating characteristic curve analyses were used to detect predictive factors. Results The following parameters were predictive of post-THA LBP: relative pelvic version (RPV) <−7° (odds ratio, 1.43; 95% confidence interval, 1.10–1.72; P = 0.032) and relative lumbar lordosis <−15° (odds ratio, 1.13; 95% confidence interval, 1.04–2.13; P = 0.041) preoperatively. Using an RPV cutoff value of − 7° (specificity 61/64 = 0.953; sensitivity 121/136 = 0.890), there were significant between-group differences in LBP visual analog scale (P = 0.020), Oswestry Disability Index (ODI, P = 0.014), EuroQol 5-Dimension (P = 0.027), Hip Disability and Osteoarthritis Outcome Score Joint Replacement (HOOS JR, P = 0.012), patient satisfaction (P = 0.024). There was clinically meaningful improvement for LBP visual analog scale (P = 0.001), ODI (P = 0.004), and HOOS JR (P < 0.001). The RPV before THA was correlated with HOOS JR (r = 0.773, P = 0.012) and ODI (r = − 0.602, P = 0.032) postoperatively. Conclusion Among the GAP score, a moderate-to-severe pelvic retroversion was significantly associated with LBP post-THA. The RPV measurement may be a useful predictor of THA outcome, which may influence patient satisfaction.
- Open Access
- 25 August 2023
- Published by SAGE Publications in CARTILAGE
- Vol. 15 (2) , 110-119
Safety and Efficacy of a Novel Polyglycolic Acid Meniscal Scaffold for Irreparable Meniscal Tear
Objective: Meniscal tears treated with a partial meniscectomy could induce knee osteoarthritis, thereby altering or damaging knee kinetics and biomechanics. We have developed a meniscal scaffold made of polyglycolic acid (PGA) coated with polylactic acid/caprolactone (PGA scaffold), which could induce new tissue growth of meniscus-like tissue. This study aimed to evaluate the safety and efficacy of a novel meniscal scaffold for the treatment of irreparable meniscal injuries. Design: This study describes the findings of a cyclic torque test and first clinical trial of a PGA scaffold for inducing meniscus-like tissue in humans. As the first step, biomechanical testing of the PGA scaffold was performed using a cyclic torque test. Six patients underwent arthroscopic implantation of the PGA scaffold. Furthermore, the patients underwent preoperative clinical, serological, radiographic, and magnetic resonance imaging examinations at 3, 6, and 12 months postoperatively. The patients also underwent a second-look arthroscopy 12 months after implantation. Results: Torque increased with increasing cyclic loading. However, no structural damage to the sample was noted after 70,000 loading cycles. All patients showed improvement in pain, Lysholm scores, Tegner activity scores, International Knee Documentation Committee, and knee injury and osteoarthritis outcome. The second-look arthroscopy revealed that meniscal tissue had regenerated in 5 patients (83%). Radiography and magnetic resonance imaging confirmed no progression of degenerative joint disease. Conclusions: The PGA scaffold could tolerate shear forces, did not produce safety concerns, and may have therapeutic potentials for irreparable meniscal tears in humans.
- 25 August 2023
- Published by SAGE Publications in CARTILAGE
- Vol. 15 (2) , 110-119
Open AccessSafety and Efficacy of a Novel Polyglycolic Acid Meniscal Scaffold for Irreparable Meniscal Tear
Objective: Meniscal tears treated with a partial meniscectomy could induce knee osteoarthritis, thereby altering or damaging knee kinetics and biomechanics. We have developed a meniscal scaffold made of polyglycolic acid (PGA) coated with polylactic acid/caprolactone (PGA scaffold), which could induce new tissue growth of meniscus-like tissue. This study aimed to evaluate the safety and efficacy of a novel meniscal scaffold for the treatment of irreparable meniscal injuries. Design: This study describes the findings of a cyclic torque test and first clinical trial of a PGA scaffold for inducing meniscus-like tissue in humans. As the first step, biomechanical testing of the PGA scaffold was performed using a cyclic torque test. Six patients underwent arthroscopic implantation of the PGA scaffold. Furthermore, the patients underwent preoperative clinical, serological, radiographic, and magnetic resonance imaging examinations at 3, 6, and 12 months postoperatively. The patients also underwent a second-look arthroscopy 12 months after implantation. Results: Torque increased with increasing cyclic loading. However, no structural damage to the sample was noted after 70,000 loading cycles. All patients showed improvement in pain, Lysholm scores, Tegner activity scores, International Knee Documentation Committee, and knee injury and osteoarthritis outcome. The second-look arthroscopy revealed that meniscal tissue had regenerated in 5 patients (83%). Radiography and magnetic resonance imaging confirmed no progression of degenerative joint disease. Conclusions: The PGA scaffold could tolerate shear forces, did not produce safety concerns, and may have therapeutic potentials for irreparable meniscal tears in humans.
- 17 February 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (4) , 1463-1470
T1 pelvic angle is associated with rapid progression of hip arthrosis
Purpose To evaluate the association between global spinal malalignment and rapid progression of hip arthrosis. Methods This was a retrospective, case–control study including 90 patients, contributing 90 hips, who underwent hemi- or total hip arthroplasty at our institution. For analysis, hips were classified into a rapid progression group, defined as ≥ 2 mm destruction of the femoral head or loss of the hip joint space within a 12-month period (n = 30), and a non-rapid progression group, defined by no observable hip disease progression over a period more than 12 months (n = 60). Logistic regression analysis identified factors that predicted rapid progression, with a receiver operating characteristic curve analysis used to confirm factors. Results Significant between-group differences were identified for the following parameters: pelvic tilt (P = 0.002, PT), sagittal vertical axis (P = 0.002, SVA), and T1 pelvic angle (P < 0.001, TPA). On multiple logistic regression, PT (P = 0.002), SVA (P = 0.002), and TPA (P < 0.001) were predictive of a rapid progression on hip arthrosis, with the area under the curve being greater for TPA than PT (P = 0.035). Conclusion Global spinal alignment is associated with rapid progression of hip arthrosis. TPA could assist in identifying patients at risk for rapid progression of hip arthrosis, allowing for time management.
- 17 February 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (4) , 1463-1470
T1 pelvic angle is associated with rapid progression of hip arthrosis
Purpose To evaluate the association between global spinal malalignment and rapid progression of hip arthrosis. Methods This was a retrospective, case–control study including 90 patients, contributing 90 hips, who underwent hemi- or total hip arthroplasty at our institution. For analysis, hips were classified into a rapid progression group, defined as ≥ 2 mm destruction of the femoral head or loss of the hip joint space within a 12-month period (n = 30), and a non-rapid progression group, defined by no observable hip disease progression over a period more than 12 months (n = 60). Logistic regression analysis identified factors that predicted rapid progression, with a receiver operating characteristic curve analysis used to confirm factors. Results Significant between-group differences were identified for the following parameters: pelvic tilt (P = 0.002, PT), sagittal vertical axis (P = 0.002, SVA), and T1 pelvic angle (P < 0.001, TPA). On multiple logistic regression, PT (P = 0.002), SVA (P = 0.002), and TPA (P < 0.001) were predictive of a rapid progression on hip arthrosis, with the area under the curve being greater for TPA than PT (P = 0.035). Conclusion Global spinal alignment is associated with rapid progression of hip arthrosis. TPA could assist in identifying patients at risk for rapid progression of hip arthrosis, allowing for time management.
- 10 November 2022
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (8) , 3106-3115
The significance of the pelvic incidence measurement as a possible predictor of TKA outcome
Purpose: To evaluate the association between the sagittal alignment of the pelvis and residual knee flexion contracture after total knee arthroplasty (TKA). This is important as a flexion contraction can be associated with the risk of poor outcomes and patient satisfaction after TKA.Methods: This was a retrospective, case–control, study of 200 osteoarthritic knees, contributed by 200 patients, over a mean follow‐up of 2.4 years. The following factors were compared between patients ‘with’ (46 knees) and ‘without’ (154 knees) a residual flexion contracture ≥ 10° after TKA: age, sex, pelvic incidence (PI), anterior femoral bowing, femoral component flexion angle (FFA), and patient‐reported outcomes. Logistic regression and receiver operating characteristic curve analyses were used to identify predictive factors.Results: The following factors were predictive of a residual flexion contracture ≥ 10°: a pelvic incidence ≥ 55° (odds ratio, 1.29; 95% confidence interval, 1.05−1.59; P = 0.031) and the FFA (odds ratio, 1.08; 95% confidence interval, 1.03−1.14; P = 0.044). A pelvic incidence cutoff of 55° yielded a significant between‐group difference, with a sensitivity of 78.4% and specificity of 89.9% to differentiate a residual knee flexion contracture ≥ 10° (P = 0.001), patient satisfaction (P = 0.029), EuroQol 5‐Dimension score (P = 0.028), anterior femoral curvature (P = 0.031), and Knee Injury and Osteoarthritis Outcome Score‐Joint Replacement score (P = 0.046).Conclusion: A pelvic incidence > 55° is associated with a residual knee flexion contracture ≥ 10° after TKA. The significance of the pelvic incidence measurement as a possible predictor of TKA outcome was highlighted, including its impact on patient satisfaction.Level of evidence: III.
- 10 November 2022
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (8) , 3106-3115
The significance of the pelvic incidence measurement as a possible predictor of TKA outcome
Purpose: To evaluate the association between the sagittal alignment of the pelvis and residual knee flexion contracture after total knee arthroplasty (TKA). This is important as a flexion contraction can be associated with the risk of poor outcomes and patient satisfaction after TKA.Methods: This was a retrospective, case–control, study of 200 osteoarthritic knees, contributed by 200 patients, over a mean follow‐up of 2.4 years. The following factors were compared between patients ‘with’ (46 knees) and ‘without’ (154 knees) a residual flexion contracture ≥ 10° after TKA: age, sex, pelvic incidence (PI), anterior femoral bowing, femoral component flexion angle (FFA), and patient‐reported outcomes. Logistic regression and receiver operating characteristic curve analyses were used to identify predictive factors.Results: The following factors were predictive of a residual flexion contracture ≥ 10°: a pelvic incidence ≥ 55° (odds ratio, 1.29; 95% confidence interval, 1.05−1.59; P = 0.031) and the FFA (odds ratio, 1.08; 95% confidence interval, 1.03−1.14; P = 0.044). A pelvic incidence cutoff of 55° yielded a significant between‐group difference, with a sensitivity of 78.4% and specificity of 89.9% to differentiate a residual knee flexion contracture ≥ 10° (P = 0.001), patient satisfaction (P = 0.029), EuroQol 5‐Dimension score (P = 0.028), anterior femoral curvature (P = 0.031), and Knee Injury and Osteoarthritis Outcome Score‐Joint Replacement score (P = 0.046).Conclusion: A pelvic incidence > 55° is associated with a residual knee flexion contracture ≥ 10° after TKA. The significance of the pelvic incidence measurement as a possible predictor of TKA outcome was highlighted, including its impact on patient satisfaction.Level of evidence: III.
- 29 September 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 29 (1) , 439-444
Unfavorable cortical hypertrophy potentially predisposes to periprosthetic “axe splitter” fracture in a collarless polished curved triple-tapered cemented stem: The time-dependent radiographic change in five SC-stem cases
- 29 September 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 29 (1) , 439-444
Unfavorable cortical hypertrophy potentially predisposes to periprosthetic “axe splitter” fracture in a collarless polished curved triple-tapered cemented stem: The time-dependent radiographic change in five SC-stem cases
- 1 September 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 27 (5) , 1100-1106
Three-dimensional transfer of tibial tuberosity for patellar instability with patella alta preserves patellar position and clinical outcomes: A minimum 3-year follow-up study
- 1 September 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 27 (5) , 1100-1106
Three-dimensional transfer of tibial tuberosity for patellar instability with patella alta preserves patellar position and clinical outcomes: A minimum 3-year follow-up study