Low‐constraint insert with a medial pivot design as a potential predictor of favourable outcomes in cruciate‐retaining total knee arthroplasty: A propensity score‐matched analysis
- 4 November 2024
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (4) , 1397-1408
Abstract
Purpose: The influence of polyethylene insert conformity on the outcomes of cruciate‐retaining (CR) total knee arthroplasty (TKA) with a medial pivot design remains uncertain. Therefore, this study aimed to evaluate the effects of polyethylene insert conformity in CR‐TKA on patient‐reported outcomes.Methods: The data of 255 knees (FINE Total Knee System) from 255 patients were retrospectively analysed to compare outcomes for high‐ or low‐constraint medial pivot inserts, as determined through historical controls, over an average follow‐up period of 2.2 years (range, 2.0–5.5 years). Multivariate logistic regression analysis was used to identify predictors of achieving the patient‐acceptable symptom state (PASS) for the Forgotten Joint Score‐12 (FJS‐12). Propensity score‐matched cohorts for age, sex, body mass index, Kellgren‐Lawrence grade, Charlson Comorbidity Index, knee flexion contracture, FJS‐12 and follow‐up duration were created for between‐group comparison (n = 50 in each group).Results: Low‐constraint insert (p = 0.031) and age (p = 0.043) were independent predictors of achieving the PASS for the FJS‐12 (>33, 153/255). After successful matching, compared to the high‐constraint insert, the low‐constraint insert improved patient satisfaction (p = 0.029 for pain on going up or downstairs, and p = 0.047 for the function of going upstairs) and increased the likelihood of achieving the minimal clinically important difference (p = 0.019) and PASS (p = 0.025) for the FJS‐12. A significant correlation was observed between the posterior tibial slope and the FJS‐12 in the low‐constraint insert group (p < 0.001), indicating that a greater posterior tibial slope was associated with better functional outcomes in this group.Conclusions: Compared with high‐constraint inserts, low‐constraint medial pivot inserts yielded higher functional outcomes and patient satisfaction. Therefore, insert conformity may play a crucial role in CR‐TKA outcomes.Level of Evidence: Level III.Keywords
This publication has 30 references indexed in Scilit:
- PCL retained is safe in medial pivot TKA—a prospective randomized trialKnee Surgery, Sports Traumatology, Arthroscopy, 2023
- PCL retention demonstrates better functional scores and gait patterns in total knee arthroplasty using a medial congruent insert—a prospective studyKnee Surgery, Sports Traumatology, Arthroscopy, 2023
- Clinical Frailty Scale is a better predictor for adverse post‐operative complications and functional outcomes than Modified Frailty Index and Charlson Comorbidity Index after total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2023
- Medial pivot design does not yield superior results compared to posterior‐stabilised total knee arthroplasty: a systematic review and meta‐analysis of randomised control trialsKnee Surgery, Sports Traumatology, Arthroscopy, 2022
- The significance of the pelvic incidence measurement as a possible predictor of TKA outcomeKnee Surgery, Sports Traumatology, Arthroscopy, 2022
- The posterolateral upslope of a low‐conforming insert blocks the medial pivot during a deep knee bend in TKA: a comparative analysis of two implants with different insert conformitiesKnee Surgery, Sports Traumatology, Arthroscopy, 2021
- Medial stabilised total knee arthroplasty achieves comparable clinical outcomes when compared to other TKA designs: a systematic review and meta‐analysis of the current literatureKnee Surgery, Sports Traumatology, Arthroscopy, 2020
- Surface Damage Versus Tibial Polyethylene Insert Conformity: A Retrieval StudyClinical Orthopaedics and Related Research, 2012
- Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?Clinical Orthopaedics and Related Research, 2010
- The effect of geometry of the tibial polyethylene insert on the tibiofemoral contact kinematics in Advance Medial Pivot total knee arthroplastyJournal of Orthopaedic Science, 2009