Aldo Toni
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aldo Toni has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Susanna Stea
Medical Technology Laboratory, Rizzoli Orthopedic Institute, Bologna, Italy
4 shared publications - Barbara Bordini
Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
3 shared publications C. Fagnano
Università di Bologna
2 shared publications- Saverio Affatato
Laboratorio di Tecnologia Medica IRCCS Istituto Ortopedico Rizzoli Bologna Italy
2 shared publications - Stefano Squarzoni
Istituto di Citomorfologia Normale e Patologica CNR
2 shared publications A. Giunti
University of Bologna
1 shared publication
Latest Publications
- Open Access
- 30 September 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (6) , 3649-3657
Long-term survivorship of an exchangeable-neck hip prosthesis with a Ti-alloy/Ti-alloy neck–stem junction
Introduction: Breakage of exchangeable-neck (EN) and adverse local tissue reactions (ALTRs) to neck–stem junction (NSJ) damage products are responsible for increasing the revision rate of EN hip prostheses. We investigated the survivorship of an EN hip prosthesis including a NSJ with both components made of titanium alloy (Ti-alloy/Ti-alloy) to assess whether, and to what extent, EN breakage and NSJ damage affected implant survivorship. Materials and methods: Using data from a hip replacement registry, we determined survivorship of 2857 EN prostheses. Long-offset configurations of head and EN were implanted in heavy (> 90 kg) patients only in 23 hips. We investigated under which conditions EN breakages or ALTRs occurred. We also measured titanium (Ti) and vanadium (V) blood concentrations in 24 patients with a unilateral well-working prosthesis. Results: The 17-year survival rates for any reason and aseptic loosening of any component were 88.9% (95%CI 87.5–90.1; 857 hips at risk) and 96.9% (95%CI 96.0–97.6), respectively. There were two cases of EN breakage and one case of ALTR (metallosis), due to rim-neck impingement, out of 276 revisions. After an average period of 9.8 years (range 7.8–12.8 years), the maximum Ti and V blood concentrations in patients with a well-working prosthesis were 5.0 µg/l and 0.16 µg/l, respectively. Conclusion: The present incidence of EN breakage or ALTR is lower than those reported in other studies evaluating EN hip prosthesis survivorship. This study suggests that (i) the risk of EN breakage is reduced by limiting the use of long-offset configurations in heavy patients and (ii) Ti-alloy/Ti-alloy NSJ damage products do not promote ALTR nor significantly alter the rate of implant loosening. Since design decisions and implant configuration determine the NSJ strength, the NSJ strength in working conditions must be thoroughly investigated to proper define the clinical indications for any EN design.
- 30 September 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (6) , 3649-3657
Open AccessLong-term survivorship of an exchangeable-neck hip prosthesis with a Ti-alloy/Ti-alloy neck–stem junction
Introduction: Breakage of exchangeable-neck (EN) and adverse local tissue reactions (ALTRs) to neck–stem junction (NSJ) damage products are responsible for increasing the revision rate of EN hip prostheses. We investigated the survivorship of an EN hip prosthesis including a NSJ with both components made of titanium alloy (Ti-alloy/Ti-alloy) to assess whether, and to what extent, EN breakage and NSJ damage affected implant survivorship. Materials and methods: Using data from a hip replacement registry, we determined survivorship of 2857 EN prostheses. Long-offset configurations of head and EN were implanted in heavy (> 90 kg) patients only in 23 hips. We investigated under which conditions EN breakages or ALTRs occurred. We also measured titanium (Ti) and vanadium (V) blood concentrations in 24 patients with a unilateral well-working prosthesis. Results: The 17-year survival rates for any reason and aseptic loosening of any component were 88.9% (95%CI 87.5–90.1; 857 hips at risk) and 96.9% (95%CI 96.0–97.6), respectively. There were two cases of EN breakage and one case of ALTR (metallosis), due to rim-neck impingement, out of 276 revisions. After an average period of 9.8 years (range 7.8–12.8 years), the maximum Ti and V blood concentrations in patients with a well-working prosthesis were 5.0 µg/l and 0.16 µg/l, respectively. Conclusion: The present incidence of EN breakage or ALTR is lower than those reported in other studies evaluating EN hip prosthesis survivorship. This study suggests that (i) the risk of EN breakage is reduced by limiting the use of long-offset configurations in heavy patients and (ii) Ti-alloy/Ti-alloy NSJ damage products do not promote ALTR nor significantly alter the rate of implant loosening. Since design decisions and implant configuration determine the NSJ strength, the NSJ strength in working conditions must be thoroughly investigated to proper define the clinical indications for any EN design.
- 11 August 2018
- Published by Springer Nature in International Orthopaedics
- Vol. 43 (1) , 103-109
The influence of bearing surfaces on periprosthetic hip infections: analysis of thirty nine thousand, two hundred and six cementless total hip arthroplasties
Periprosthetic hip infection (PHI) is a devastating complication. The association between PHI and bearing surfaces as well as patient-related factors has been recently investigated, with contradictive outcomes. The dataset of Emilia-Romagna region Registry for Orthopaedic Prosthetic Implants (RIPO) has been assessed to investigate, if the bearing choice influenced the risk of septic loosening occurrence.
- 11 August 2018
- Published by Springer Nature in International Orthopaedics
- Vol. 43 (1) , 103-109
The influence of bearing surfaces on periprosthetic hip infections: analysis of thirty nine thousand, two hundred and six cementless total hip arthroplasties
Periprosthetic hip infection (PHI) is a devastating complication. The association between PHI and bearing surfaces as well as patient-related factors has been recently investigated, with contradictive outcomes. The dataset of Emilia-Romagna region Registry for Orthopaedic Prosthetic Implants (RIPO) has been assessed to investigate, if the bearing choice influenced the risk of septic loosening occurrence.
- 1 May 2013
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 28 (5) , 838-841
Ceramic Debris in Hip Prosthesis: Correlation Between Synovial Fluid and Joint Capsule
- 1 May 2013
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 28 (5) , 838-841
Ceramic Debris in Hip Prosthesis: Correlation Between Synovial Fluid and Joint Capsule
- 6 June 2006
- Published by Springer Nature in Journal of Materials Science
- Vol. 41 (16) , 5310-5316
Wear behaviour, fluorescence and SEM investigations on nanocomposite zirconia-toughened alumina
- 6 June 2006
- Published by Springer Nature in Journal of Materials Science
- Vol. 41 (16) , 5310-5316
Wear behaviour, fluorescence and SEM investigations on nanocomposite zirconia-toughened alumina
- Open Access
- 1 October 2005
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 20 (2) , 103-121
Isolation and Characterization of Wear Debris Generated in Patients Wearing Polyethylene Hylamer Inserts, Gamma Irradiated in Air
Hylamer polyethylene was used in the early 1990s to make hip-joint components. Clinical experience has shown that these components, if sterilized by gamma rays in the presence of oxygen, are easily affected by wear, which then leads to osteolysis. The authors analyzed polyethylene wear particles in seven patients who had received Hylamer polyethylene implants sterilized by gamma rays in air and had suffered prosthetic loosening. The results were compared to those of six controls, who had received traditional polyethylene implants, sterilized by the same method. The frequency distribution of globular and fibrillar particles was similar in both groups (38.5% in Hylamer, 45.2% in controls). The globular particles in the Hylamer samples had a mean area of 0.12 mm2, which was significantly lesser than that of the controls (0.30 mm2). The width of fibrillar particles in the Hylamer samples was significantly lesser than that of the controls. Therefore, the two materials, despite undergoing the same type of sterilization, produced different types of wear, due to their different properties. In conclusion, the difference in the morphology of Hylamer polyethylene wear particles in comparison with PCA might have caused a more intensive biological response, early and massive osteolysis, and therefore, early loosening.
- 1 October 2005
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 20 (2) , 103-121
Open AccessIsolation and Characterization of Wear Debris Generated in Patients Wearing Polyethylene Hylamer Inserts, Gamma Irradiated in Air
Hylamer polyethylene was used in the early 1990s to make hip-joint components. Clinical experience has shown that these components, if sterilized by gamma rays in the presence of oxygen, are easily affected by wear, which then leads to osteolysis. The authors analyzed polyethylene wear particles in seven patients who had received Hylamer polyethylene implants sterilized by gamma rays in air and had suffered prosthetic loosening. The results were compared to those of six controls, who had received traditional polyethylene implants, sterilized by the same method. The frequency distribution of globular and fibrillar particles was similar in both groups (38.5% in Hylamer, 45.2% in controls). The globular particles in the Hylamer samples had a mean area of 0.12 mm2, which was significantly lesser than that of the controls (0.30 mm2). The width of fibrillar particles in the Hylamer samples was significantly lesser than that of the controls. Therefore, the two materials, despite undergoing the same type of sterilization, produced different types of wear, due to their different properties. In conclusion, the difference in the morphology of Hylamer polyethylene wear particles in comparison with PCA might have caused a more intensive biological response, early and massive osteolysis, and therefore, early loosening.
- 1 January 2001
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 215 (1) , 107-111
Fluid absorption study in ultra-high molecular weight polyethylene (UHMWPE) sterilized and unsterilized acetabular cups
The weight gain due to fluid absorption was measured in γ-sterilized, ethylene oxide (ETO) gas-sterilized, and unsterilized ultra-high molecular weight (UHMW) polyethylene acetabular cups. After about 2 months the total average fluid absorption gain of the polyethylene cups was: 1.76 ± 0.45 mg (average ± standard deviation) for the unsterilized polyethylene cups, 2.81 ± 0.95 mg for the γ-sterilized polyethylene cups and 1.51 ± 0.34 for the ETO gas-sterilized polyethylene cups. There was little difference in fluid absorption between the sterilized and unsterilized specimens. In particular, the γ-sterilized acetabular cups absorbed more than the ETO gas-sterilized and the unsterilized cups. However, the weight gain was higher in serum compared with that in water.
- 1 January 2001
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 215 (1) , 107-111
Fluid absorption study in ultra-high molecular weight polyethylene (UHMWPE) sterilized and unsterilized acetabular cups
The weight gain due to fluid absorption was measured in γ-sterilized, ethylene oxide (ETO) gas-sterilized, and unsterilized ultra-high molecular weight (UHMW) polyethylene acetabular cups. After about 2 months the total average fluid absorption gain of the polyethylene cups was: 1.76 ± 0.45 mg (average ± standard deviation) for the unsterilized polyethylene cups, 2.81 ± 0.95 mg for the γ-sterilized polyethylene cups and 1.51 ± 0.34 for the ETO gas-sterilized polyethylene cups. There was little difference in fluid absorption between the sterilized and unsterilized specimens. In particular, the γ-sterilized acetabular cups absorbed more than the ETO gas-sterilized and the unsterilized cups. However, the weight gain was higher in serum compared with that in water.
- 1 March 1996
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 7 (3) , 149-152
Bone remodelling after total hip arthroplasty
- 1 March 1996
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 7 (3) , 149-152
Bone remodelling after total hip arthroplasty