Madelon van Den Dobbelsteen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Madelon van Den Dobbelsteen has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Bram van Asselen
Department of Radiotherapy University Medical Center Utrecht Utrecht Netherlands
6 shared publications- Stijn Oolbekkink
Department of Radiotherapy University Medical Center Utrecht Utrecht The Netherlands
6 shared publications Bas W. Raaymakers
Department of Radiotherapy University Medical Center Utrecht Utrecht Netherlands
4 shared publicationsB. van Asselen
3 shared publications- Martin F. Fast
Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
3 shared publications - Bas W. Raaymakers
Department of Radiotherapy, University Medical Center Utrecht, Netherlands
2 shared publications
Latest Publications
- Open Access
- 25 December 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (2) , e14604
Validation of a diode‐based phantom for high temporal and spatial measurements in a 1.5 T MR‐linac
Background: For the development and validation of dynamic treatment modalities and processes on the MR‐linac, independent measurements should be performed that validate dose delivery and linac behavior at a high temporal resolution. To achieve this, a detector with both high temporal and spatial resolution is necessary.Purpose: This study investigates the suitability of a Delta4 Phantom+ MR (Delta4) detector array for time‐resolved dosimetry in the 1.5 T MR‐linac and characterizes the Delta4's performance with dynamic dose delivery, such as beam gating and field modulation during radiation.Methods: A Delta4 detector was used, including software for time‐resolved dosimetry. First validation experiments were performed and compared to reference measurements. Subsequently, demonstrator measurements were performed to show use cases of the Delta4's time‐resolved dose readouts. An example of such an experiment is the determination of the field speed during a sliding window experiment, traveling between 0.7 and 6.8 cm/s in the cranial‐caudal direction.Results: Validation experiments of the dose reproducibility and dose rate dependency showed no difference relative to the standard static delivery. The field speed measured by the Delta4 showed an average field speed difference of −0.3% relative to MR‐linac log files. The Delta4 was capable of measuring the dose with high accuracy and temporal resolution during dynamic radiation delivery.Conclusion: The Delta4 can be used for time‐resolved dosimetry in a 1.5 T MR‐linac.
- 25 December 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (2) , e14604
Open AccessValidation of a diode‐based phantom for high temporal and spatial measurements in a 1.5 T MR‐linac
Background: For the development and validation of dynamic treatment modalities and processes on the MR‐linac, independent measurements should be performed that validate dose delivery and linac behavior at a high temporal resolution. To achieve this, a detector with both high temporal and spatial resolution is necessary.Purpose: This study investigates the suitability of a Delta4 Phantom+ MR (Delta4) detector array for time‐resolved dosimetry in the 1.5 T MR‐linac and characterizes the Delta4's performance with dynamic dose delivery, such as beam gating and field modulation during radiation.Methods: A Delta4 detector was used, including software for time‐resolved dosimetry. First validation experiments were performed and compared to reference measurements. Subsequently, demonstrator measurements were performed to show use cases of the Delta4's time‐resolved dose readouts. An example of such an experiment is the determination of the field speed during a sliding window experiment, traveling between 0.7 and 6.8 cm/s in the cranial‐caudal direction.Results: Validation experiments of the dose reproducibility and dose rate dependency showed no difference relative to the standard static delivery. The field speed measured by the Delta4 showed an average field speed difference of −0.3% relative to MR‐linac log files. The Delta4 was capable of measuring the dose with high accuracy and temporal resolution during dynamic radiation delivery.Conclusion: The Delta4 can be used for time‐resolved dosimetry in a 1.5 T MR‐linac.
- Open Access
- 24 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (1) , 015003
Quantifying the spatial distribution of the accumulated dose uncertainty using the novel delta index
Objective. Inter- and intra-fractional anatomical changes during a radiotherapy treatment can cause differences between the initially planned dose and the delivered dose. The total delivered dose can be accumulated over all fractions by using deformable image registration (DIR). However, there is uncertainty in this process which should be accounted for. The aim of this study is to propose a novel metric estimating the spatial distribution of the accumulated dose uncertainty and to evaluate its performance for multi-fraction online adaptive treatments. Approach. We postulate a new metric, the delta (δ) index, to estimate the uncertainties associated with the dose accumulation process. This metric is calculated for each voxel and takes into account the spatial uncertainty in DIR and local dose differences. For the spatial uncertainty of the DIR, the distance discordance metric was used. The accumulated dose and the δ index were determined for ten lung stereotactic body radiation therapy patients. The δ index was complemented by a more understandable metric, the δ index passing rate, which is the percentage of points satisfying the passing criteria in a region. Main results. The spatial distribution of the δ index and the δ index passing rates showed that voxels failing the criteria were predominantly in lower-dose regions. The mean percentage of voxels passing the criterion increased from 65% to 78%, for threshold doses of 20% and 90% of the prescription doses, respectively. Significance. The δ index was postulated to quantify the spatial distribution of the uncertainties associated with the dose accumulation process. The metric gives an intuitive understanding of the reliability of accumulated dose distributions and derived DVH metrics. The performance of the δ index was evaluated for multi-fraction online adaptive treatments, where a case of sub-optimal image registration was identified by the metric.
- 24 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (1) , 015003
Open AccessQuantifying the spatial distribution of the accumulated dose uncertainty using the novel delta index
Objective. Inter- and intra-fractional anatomical changes during a radiotherapy treatment can cause differences between the initially planned dose and the delivered dose. The total delivered dose can be accumulated over all fractions by using deformable image registration (DIR). However, there is uncertainty in this process which should be accounted for. The aim of this study is to propose a novel metric estimating the spatial distribution of the accumulated dose uncertainty and to evaluate its performance for multi-fraction online adaptive treatments. Approach. We postulate a new metric, the delta (δ) index, to estimate the uncertainties associated with the dose accumulation process. This metric is calculated for each voxel and takes into account the spatial uncertainty in DIR and local dose differences. For the spatial uncertainty of the DIR, the distance discordance metric was used. The accumulated dose and the δ index were determined for ten lung stereotactic body radiation therapy patients. The δ index was complemented by a more understandable metric, the δ index passing rate, which is the percentage of points satisfying the passing criteria in a region. Main results. The spatial distribution of the δ index and the δ index passing rates showed that voxels failing the criteria were predominantly in lower-dose regions. The mean percentage of voxels passing the criterion increased from 65% to 78%, for threshold doses of 20% and 90% of the prescription doses, respectively. Significance. The δ index was postulated to quantify the spatial distribution of the uncertainties associated with the dose accumulation process. The metric gives an intuitive understanding of the reliability of accumulated dose distributions and derived DVH metrics. The performance of the δ index was evaluated for multi-fraction online adaptive treatments, where a case of sub-optimal image registration was identified by the metric.
- Open Access
- 9 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (24) , 24NT02
An improved calibration procedure for accurate plastic scintillation dosimetry on an MR-linac
Objective. Plastic scintillation dosimeters (PSDs) are highly suitable for real-time dosimetry on the MR-linac. For optimal performance, the primary signal (scintillation) needs to be separated from secondary optical effects (Cerenkov, fluorescence and optical fiber attenuation). This requires a spectral separation approach and careful calibration. Currently, the ‘classic’ calibration is a multi-step procedure using both kV and MV x-ray sources, requiring an uninterrupted optical connection between the dosimeter and read-out system, complicating efficient use of PSDs. Therefore, we present a more time-efficient and more practical novel calibration technique for PSDs suitable for MR-linac dosimetry. Approach. The novel calibration relies on prior spectral information combined with two 10 × 10 cm2 field irradiations on the 1.5 T MR-linac. Performance of the novel calibration technique was evaluated focusing on its reproducibility, performance characteristics (repeatability, linearity, dose rate dependency, output factors, angular response and detector angle dependency) and IMRT deliveries. To investigate the calibration stability over time, prior spectral information up to 315 days old was used. To quantify the time efficiency, each step of the novel and classic calibration was timed. Main results. The novel calibration showed a high reproducibility with a maximum relative standard deviation of 0.2%. The novel method showed maximum differences of 1.2% compared to the gold-standard calibration, while reusing old classic calibrations after reconnecting fibers showed differences up to 3.0%. The novel calibration improved time efficiency from 105 to 30 min compared to the classic method. Significance. The novel calibration method showed a gain in time efficiency and practicality while preserving the dosimetric accuracy. Therefore, this method can replace the traditional method for PSDs suitable for MR-linac dosimetry, using prior spectral information of up to a year. This novel calibration facilitates reconnecting the detector to the read-out system which would lead to unacceptable dosimetric results with the classic calibration method.
- 9 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (24) , 24NT02
Open AccessAn improved calibration procedure for accurate plastic scintillation dosimetry on an MR-linac
Objective. Plastic scintillation dosimeters (PSDs) are highly suitable for real-time dosimetry on the MR-linac. For optimal performance, the primary signal (scintillation) needs to be separated from secondary optical effects (Cerenkov, fluorescence and optical fiber attenuation). This requires a spectral separation approach and careful calibration. Currently, the ‘classic’ calibration is a multi-step procedure using both kV and MV x-ray sources, requiring an uninterrupted optical connection between the dosimeter and read-out system, complicating efficient use of PSDs. Therefore, we present a more time-efficient and more practical novel calibration technique for PSDs suitable for MR-linac dosimetry. Approach. The novel calibration relies on prior spectral information combined with two 10 × 10 cm2 field irradiations on the 1.5 T MR-linac. Performance of the novel calibration technique was evaluated focusing on its reproducibility, performance characteristics (repeatability, linearity, dose rate dependency, output factors, angular response and detector angle dependency) and IMRT deliveries. To investigate the calibration stability over time, prior spectral information up to 315 days old was used. To quantify the time efficiency, each step of the novel and classic calibration was timed. Main results. The novel calibration showed a high reproducibility with a maximum relative standard deviation of 0.2%. The novel method showed maximum differences of 1.2% compared to the gold-standard calibration, while reusing old classic calibrations after reconnecting fibers showed differences up to 3.0%. The novel calibration improved time efficiency from 105 to 30 min compared to the classic method. Significance. The novel calibration method showed a gain in time efficiency and practicality while preserving the dosimetric accuracy. Therefore, this method can replace the traditional method for PSDs suitable for MR-linac dosimetry, using prior spectral information of up to a year. This novel calibration facilitates reconnecting the detector to the read-out system which would lead to unacceptable dosimetric results with the classic calibration method.
- Open Access
- 21 April 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 30, 100580
Treatment planning evaluation and experimental validation of the magnetic resonance-based intrafraction drift correction
- 21 April 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 30, 100580
Open AccessTreatment planning evaluation and experimental validation of the magnetic resonance-based intrafraction drift correction
- Open Access
- 15 February 2024
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 45, 100744
Stereotactic body radiotherapy of central lung tumours using a 1.5 T MR-linac: First clinical experiences
- 15 February 2024
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 45, 100744
Open AccessStereotactic body radiotherapy of central lung tumours using a 1.5 T MR-linac: First clinical experiences
- Open Access
- 27 November 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (1) , e14180
Influence of magnetic field on a novel scintillation dosimeter in a 1.5 T MR‐linac
For commissioning and quality assurance for adaptive workflows on the MR‐linac, a dosimeter which can measure time‐resolved dose during MR image acquisition is desired. The Blue Physics model 10 scintillation dosimeter is potentially an ideal detector for such measurements. However, some detectors can be influenced by the magnetic field of the MR‐linac. To assess the calibration methods and magnetic field dependency of the Blue Physics scintillator in the 1.5 T MR‐linac. Several calibration methods were assessed for robustness. Detector characteristics and the influence of the calibration methods were assessed based on dose reproducibility, dose linearity, dose rate dependency, relative output factor (ROF), percentage depth dose profile, axial rotation and the radial detector orientation with respect to the magnetic field. The potential application of time‐resolved dynamic dose measurements during MRI acquisition was assessed. A variation of calibration factors was observed for different calibration methods. Dose reproducibility, dose linearity and dose rate stability were all found to be within tolerance and were not significantly affected by different calibration methods. Measurements with the detector showed good correspondence with reference chambers. The ROF and radial orientation dependence measurements were influenced by the calibration method used. Axial detector dependence was assessed and relative readout differences of up to 2.5% were observed. A maximum readout difference of 10.8% was obtained when rotating the detector with respect to the magnetic field. Importantly, measurements with and without MR image acquisition were consistent for both static and dynamic situations. The Blue Physics scintillation detector is suitable for relative dosimetry in the 1.5 T MR‐linac when measurements are within or close to calibration conditions.
- 27 November 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (1) , e14180
Open AccessInfluence of magnetic field on a novel scintillation dosimeter in a 1.5 T MR‐linac
For commissioning and quality assurance for adaptive workflows on the MR‐linac, a dosimeter which can measure time‐resolved dose during MR image acquisition is desired. The Blue Physics model 10 scintillation dosimeter is potentially an ideal detector for such measurements. However, some detectors can be influenced by the magnetic field of the MR‐linac. To assess the calibration methods and magnetic field dependency of the Blue Physics scintillator in the 1.5 T MR‐linac. Several calibration methods were assessed for robustness. Detector characteristics and the influence of the calibration methods were assessed based on dose reproducibility, dose linearity, dose rate dependency, relative output factor (ROF), percentage depth dose profile, axial rotation and the radial detector orientation with respect to the magnetic field. The potential application of time‐resolved dynamic dose measurements during MRI acquisition was assessed. A variation of calibration factors was observed for different calibration methods. Dose reproducibility, dose linearity and dose rate stability were all found to be within tolerance and were not significantly affected by different calibration methods. Measurements with the detector showed good correspondence with reference chambers. The ROF and radial orientation dependence measurements were influenced by the calibration method used. Axial detector dependence was assessed and relative readout differences of up to 2.5% were observed. A maximum readout difference of 10.8% was obtained when rotating the detector with respect to the magnetic field. Importantly, measurements with and without MR image acquisition were consistent for both static and dynamic situations. The Blue Physics scintillation detector is suitable for relative dosimetry in the 1.5 T MR‐linac when measurements are within or close to calibration conditions.
- Open Access
- 9 November 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 28, 100507
Experimental validation of multi-fraction online adaptations in magnetic resonance guided radiotherapy
- 9 November 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 28, 100507
Open AccessExperimental validation of multi-fraction online adaptations in magnetic resonance guided radiotherapy
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S213-S214
OC-0279 Validation of intra-fraction adaptations for the MR-linac: novel drift correction and replanning
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S213-S214
OC-0279 Validation of intra-fraction adaptations for the MR-linac: novel drift correction and replanning
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S470-S471
PD-0588 Performance characterization of the Blue Physics scintillator in the 1.5T MR-linac
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S470-S471
PD-0588 Performance characterization of the Blue Physics scintillator in the 1.5T MR-linac
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S617-S618
PD-0751 Experimental verification of accumulated dose of multifraction plan adaptations on the MR-linac
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S617-S618
PD-0751 Experimental verification of accumulated dose of multifraction plan adaptations on the MR-linac