Shaharier Kabir
Shaharier Kabir has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Abu Shufian
Department of Electrical and Electronic Engineering, American International University-Bangladesh, Dhaka, Bangladesh
6 shared publications - Nur Mohammad
Chittagong University of Engineering and Technology (CUET)
2 shared publications - Saidur Rashid Mahin
Lamar University,Dept. of Electrical Engineering,Texas,USA,77705
2 shared publications - Sajid Hossain
American International University-Bangladesh,Dept. of Electrical and Electronic Engineering,Dhaka,Bangladesh
2 shared publications - Ashikul Islam
National Institute of Neurosciences and Hospital
1 shared publication Atm Rakibul Hassan Hemel
Bangladesh Army University of Engineering Technology,Dept. of CE,Natore
1 shared publication
Latest Publications
- Open Access
- 15 January 2025
- Published by Springer Nature in Research Square
Proactive Detection of Cyber-Physical Grid Attacks: A Pre-Attack Phase Identification and Analysis Using Anomaly-Based Machine Learning Models
Cyber-physical power systems (CPPS), such as smart grids, are increasingly vital to modern infrastructure but are also highly vulnerable to sophisticated cyber-attacks. Traditional security measures often detect these attacks only after significant damage has occurred, highlighting the need for proactive approaches that can identify potential threats before they fully manifest. This research presents a comprehensive investigation into the use of machine learning models for the early detection of cyber-attacks in a smart grid environment, with a particular focus on identifying pre-attack phases. We employed several unsupervised learning algorithms, including Isolation Forest, K-Means Clustering, DBSCAN, and One-Class SVM, to analyze a time series dataset that simulates normal operations and various attack scenarios. Among these models, Isolation Forest demonstrated superior performance, achieving an Area Under Curve (AUC) score of 1.0, accuracy of 100%, and a sensitivity of 100% in detecting anomalies. DBSCAN also performed well, with an AUC of 0.79 and accuracy of 97.3%, although it exhibited a slightly higher false positive rate compared to Isolation Forest. To detect pre-attack phases, we focused on the anomaly scores generated by the Isolation Forest model. By adjusting the sensitivity threshold, we identified periods of abnormal behavior that precede actual attacks. A threshold of 0.3 for anomaly scores provided a balanced detection, revealing multiple pre-attack phases while maintaining a low false positive rate. However, a higher threshold of 0.97, while reducing false positives, resulted in the detection of fewer pre-attack phases, indicating that the attacks may occur more abruptly without significant pre-attack indicators. These findings underscore the potential of machine learning models in enhancing the security of cyber-physical systems by not only detecting attacks but also providing early warnings through the identification of pre-attack phases. This proactive approach could significantly mitigate the impact of cyber-attacks on critical infrastructure, offering a valuable tool for cybersecurity professionals in safeguarding these systems.
- 15 January 2025
- Published by Springer Nature in Research Square
Open AccessProactive Detection of Cyber-Physical Grid Attacks: A Pre-Attack Phase Identification and Analysis Using Anomaly-Based Machine Learning Models
Cyber-physical power systems (CPPS), such as smart grids, are increasingly vital to modern infrastructure but are also highly vulnerable to sophisticated cyber-attacks. Traditional security measures often detect these attacks only after significant damage has occurred, highlighting the need for proactive approaches that can identify potential threats before they fully manifest. This research presents a comprehensive investigation into the use of machine learning models for the early detection of cyber-attacks in a smart grid environment, with a particular focus on identifying pre-attack phases. We employed several unsupervised learning algorithms, including Isolation Forest, K-Means Clustering, DBSCAN, and One-Class SVM, to analyze a time series dataset that simulates normal operations and various attack scenarios. Among these models, Isolation Forest demonstrated superior performance, achieving an Area Under Curve (AUC) score of 1.0, accuracy of 100%, and a sensitivity of 100% in detecting anomalies. DBSCAN also performed well, with an AUC of 0.79 and accuracy of 97.3%, although it exhibited a slightly higher false positive rate compared to Isolation Forest. To detect pre-attack phases, we focused on the anomaly scores generated by the Isolation Forest model. By adjusting the sensitivity threshold, we identified periods of abnormal behavior that precede actual attacks. A threshold of 0.3 for anomaly scores provided a balanced detection, revealing multiple pre-attack phases while maintaining a low false positive rate. However, a higher threshold of 0.97, while reducing false positives, resulted in the detection of fewer pre-attack phases, indicating that the attacks may occur more abruptly without significant pre-attack indicators. These findings underscore the potential of machine learning models in enhancing the security of cyber-physical systems by not only detecting attacks but also providing early warnings through the identification of pre-attack phases. This proactive approach could significantly mitigate the impact of cyber-attacks on critical infrastructure, offering a valuable tool for cybersecurity professionals in safeguarding these systems.
- Open Access
- 15 November 2024
- Published by Springer Nature in Smart Grids and Sustainable Energy
- Vol. 9 (2) , 1-30
Investigation and Performance Optimization of Modular Multilevel Converter-based HVDC Systems for Smart Grids: Control, Harmonic Analysis and Power Quality Enhancement
- 15 November 2024
- Published by Springer Nature in Smart Grids and Sustainable Energy
- Vol. 9 (2) , 1-30
Open AccessInvestigation and Performance Optimization of Modular Multilevel Converter-based HVDC Systems for Smart Grids: Control, Harmonic Analysis and Power Quality Enhancement
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A GIS Based Study on Solar Thermal System Integration for Domestic Hot Water Needs
This paper aims to provide a good concept of installing solar collectors by considering different aspects such as collector parameters, efficiency, sizing, energy demand etc. Promatop 1.5 (vertical) collector model has been chosen for the solar thermal system integration with a view to considering Domestic Hot Water (DHW) usage. Besides, Spanish CTE regulation on different aspects has also been considered for this work. Utilizing the Photovoltaic Geographical Information System (PVGIS) open-source interactive tool for collecting solar related data is also a good aspect of this study. Further, this study provides a compact overview of the integration of solar thermal systems to understand its main characteristics and requirements.
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A GIS Based Study on Solar Thermal System Integration for Domestic Hot Water Needs
This paper aims to provide a good concept of installing solar collectors by considering different aspects such as collector parameters, efficiency, sizing, energy demand etc. Promatop 1.5 (vertical) collector model has been chosen for the solar thermal system integration with a view to considering Domestic Hot Water (DHW) usage. Besides, Spanish CTE regulation on different aspects has also been considered for this work. Utilizing the Photovoltaic Geographical Information System (PVGIS) open-source interactive tool for collecting solar related data is also a good aspect of this study. Further, this study provides a compact overview of the integration of solar thermal systems to understand its main characteristics and requirements.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 514-519
Smart Monitoring And Control Of Water Purification System Using UF Membrane Filtration
Clean, accessible water is critical to human health, a healthy environment, peace, and security. The availability of safe drinking water supplies is a main concern for an overpopulated country like Bangladesh. A large proportion of the population of Bangladesh still does not have access to adequate, clean, and pure water. The scarcity of water poses a major threat to several areas of society, including food security. In this work, we will develop a coin-based water ATM system with ultra membrane filtration that will ensure the availability of pure, fresh, and safe drinking water for a large population at a low cost. Besides, adding GSM features will ensure easy maintenance and monitoring of the system. This device can be used in various crowded and public places like busy roads, highways, railway junctions, shopping malls, etc.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 514-519
Smart Monitoring And Control Of Water Purification System Using UF Membrane Filtration
Clean, accessible water is critical to human health, a healthy environment, peace, and security. The availability of safe drinking water supplies is a main concern for an overpopulated country like Bangladesh. A large proportion of the population of Bangladesh still does not have access to adequate, clean, and pure water. The scarcity of water poses a major threat to several areas of society, including food security. In this work, we will develop a coin-based water ATM system with ultra membrane filtration that will ensure the availability of pure, fresh, and safe drinking water for a large population at a low cost. Besides, adding GSM features will ensure easy maintenance and monitoring of the system. This device can be used in various crowded and public places like busy roads, highways, railway junctions, shopping malls, etc.
- 21 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 269-273
Three Phase Fault Analysis Using Thermal-Magnetic Circuit Breaker and Overcurrent Relay
Due to the modernization of the power system, automatic monitoring, control, and protection are observed from electricity generation via transmission to the consumer end. Sometimes an unwanted fault occurs in power transmission lines, which breaks the uninterrupted electricity flow. Hence, a huge amount of power loss happens. This paper presents an in-depth study of three-phase failures in electrical power systems employing an overcurrent relay and a magnetic breaker. One of the most dangerous disruptions that can affect electricity systems is a three-phase failure, which can seriously harm machinery and endanger people's safety. The overcurrent relay and magnetic breaker are two common safeguards for spotting and isolating faults. With the combination of a thermal-magnetic circuit breaker and an overcurrent relay system, this research investigates three-phase fault automatic detection and protection. And examines how the magnetic breaker and overcurrent relay identify and stop faults, noting their benefits and drawbacks. The investigation offers important insights into the efficient use of magnetic breakers and overcurrent relays for improved fault detection and protection in electrical power systems.
- 21 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 269-273
Three Phase Fault Analysis Using Thermal-Magnetic Circuit Breaker and Overcurrent Relay
Due to the modernization of the power system, automatic monitoring, control, and protection are observed from electricity generation via transmission to the consumer end. Sometimes an unwanted fault occurs in power transmission lines, which breaks the uninterrupted electricity flow. Hence, a huge amount of power loss happens. This paper presents an in-depth study of three-phase failures in electrical power systems employing an overcurrent relay and a magnetic breaker. One of the most dangerous disruptions that can affect electricity systems is a three-phase failure, which can seriously harm machinery and endanger people's safety. The overcurrent relay and magnetic breaker are two common safeguards for spotting and isolating faults. With the combination of a thermal-magnetic circuit breaker and an overcurrent relay system, this research investigates three-phase fault automatic detection and protection. And examines how the magnetic breaker and overcurrent relay identify and stop faults, noting their benefits and drawbacks. The investigation offers important insights into the efficient use of magnetic breakers and overcurrent relays for improved fault detection and protection in electrical power systems.
- 8 October 2022
- Published by Springer Nature in Technology and Economics of Smart Grids and Sustainable Energy
- Vol. 7 (1) , 1-20
Optimized Performance and Economic Assessment for Hybrid Island Microgrid System Considering Uncertainties
- 8 October 2022
- Published by Springer Nature in Technology and Economics of Smart Grids and Sustainable Energy
- Vol. 7 (1) , 1-20
Optimized Performance and Economic Assessment for Hybrid Island Microgrid System Considering Uncertainties