Muyang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muyang Wang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Han Wen
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
3 shared publications - Dumitru Mazilu
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
2 shared publications - Eric E. Bennett
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
2 shared publications - Alfredo Lebron
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
1 shared publication - Aneesha Baral
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
1 shared publication - Brianna Matthew
Laboratory of Imaging Physics, Biochemistry and Biophysics Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
1 shared publication
Latest Publications
- Open Access
- 15 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (14) , 1529
Clinical Trial Validation of Automated Segmentation and Scoring of Pulmonary Cysts in Thoracic CT Scans
In cystic lung diseases such as lymphangioleiomyomatosis (LAM), a CT-based cyst score that measures the percentage of the lung volume occupied by cysts is a common index of the cyst burden in the lungs. Although the current semi-automatic measurement of the cyst score is well established, it is susceptible to human operator variabilities. We recently developed a fully automatic method incorporating adaptive features in place of manual adjustments. In this clinical study, the automatic method is validated against the standard method in several aspects. These include the agreement between the cyst scores of the two methods, the agreement of each method with independent tests of pulmonary function, and the temporal consistency of the measurements in the consecutive visits of the same patients. We found that the automatic method agreed with the standard method as well as the agreement between two trained operators running the same standard method; both methods obtained the same level of correlation with laboratory pulmonary function tests; the automated method had better temporal consistency than the standard method (p < 0.0001). The study indicates that the automatic method could replace the standard method and provide better consistency in assessing the extent of cystic changes in the lungs of patients.
- 15 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (14) , 1529
Open AccessClinical Trial Validation of Automated Segmentation and Scoring of Pulmonary Cysts in Thoracic CT Scans
In cystic lung diseases such as lymphangioleiomyomatosis (LAM), a CT-based cyst score that measures the percentage of the lung volume occupied by cysts is a common index of the cyst burden in the lungs. Although the current semi-automatic measurement of the cyst score is well established, it is susceptible to human operator variabilities. We recently developed a fully automatic method incorporating adaptive features in place of manual adjustments. In this clinical study, the automatic method is validated against the standard method in several aspects. These include the agreement between the cyst scores of the two methods, the agreement of each method with independent tests of pulmonary function, and the temporal consistency of the measurements in the consecutive visits of the same patients. We found that the automatic method agreed with the standard method as well as the agreement between two trained operators running the same standard method; both methods obtained the same level of correlation with laboratory pulmonary function tests; the automated method had better temporal consistency than the standard method (p < 0.0001). The study indicates that the automatic method could replace the standard method and provide better consistency in assessing the extent of cystic changes in the lungs of patients.
- Open Access
- 21 October 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (10) , 292
Online Calibration of a Linear Micro Tomosynthesis Scanner
In a linear tomosynthesis scanner designed for imaging histologic samples of several centimeters size at 10 µm resolution, the mechanical instability of the scanning stage (±10 µm) exceeded the resolution of the image system, making it necessary to determine the trajectory of the stage for each scan to avoid blurring and artifacts in the images that would arise from the errors in the geometric information used in 3D reconstruction. We present a method for online calibration by attaching a layer of randomly dispersed micro glass beads or calcium particles to the bottom of the sample stage. The method was based on a parametric representation of the rigid body motion of the sample stage-marker layer assembly. The marker layer was easy to produce and proven effective in the calibration procedure.
- 21 October 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (10) , 292
Open AccessOnline Calibration of a Linear Micro Tomosynthesis Scanner
In a linear tomosynthesis scanner designed for imaging histologic samples of several centimeters size at 10 µm resolution, the mechanical instability of the scanning stage (±10 µm) exceeded the resolution of the image system, making it necessary to determine the trajectory of the stage for each scan to avoid blurring and artifacts in the images that would arise from the errors in the geometric information used in 3D reconstruction. We present a method for online calibration by attaching a layer of randomly dispersed micro glass beads or calcium particles to the bottom of the sample stage. The method was based on a parametric representation of the rigid body motion of the sample stage-marker layer assembly. The marker layer was easy to produce and proven effective in the calibration procedure.
- Open Access
- 12 October 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2547-2555
Online Geometric Calibration of a Hybrid CT System for Ultrahigh-Resolution Imaging
A hybrid imaging system consisting of a standard computed tomography (CT) scanner and a low-profile photon-counting detector insert in contact with the patient’s body has been used to produce ultrahigh-resolution images in a limited volume in chest scans of patients. The detector insert is placed on the patient bed as needed and not attached. Thus, its position and orientation in the scanner is dependent on the patient’s position and scan settings. To allow accurate image reconstruction, we devised a method of determining the relative geometry of the detector insert and the CT scanner for each scan using fiducial markers. This method uses an iterative registration algorithm to align the markers in the reconstructed volume from the detector insert to that of the concurrent CT scan. After obtaining precise geometric information of the detector insert relative to the CT scanner, the two complementary sets of images are summed together to create a detailed image with reduced artifacts.
- 12 October 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2547-2555
Open AccessOnline Geometric Calibration of a Hybrid CT System for Ultrahigh-Resolution Imaging
A hybrid imaging system consisting of a standard computed tomography (CT) scanner and a low-profile photon-counting detector insert in contact with the patient’s body has been used to produce ultrahigh-resolution images in a limited volume in chest scans of patients. The detector insert is placed on the patient bed as needed and not attached. Thus, its position and orientation in the scanner is dependent on the patient’s position and scan settings. To allow accurate image reconstruction, we devised a method of determining the relative geometry of the detector insert and the CT scanner for each scan using fiducial markers. This method uses an iterative registration algorithm to align the markers in the reconstructed volume from the detector insert to that of the concurrent CT scan. After obtaining precise geometric information of the detector insert relative to the CT scanner, the two complementary sets of images are summed together to create a detailed image with reduced artifacts.