AMAlasdair Gregor McLean

Alasdair Gregor McLean

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alasdair Gregor McLean has a total of 140 co-authors. Here are the top co-authors by number of shared publications:

  • N.J.C. Spooner

    Department of Physics and Astronomy, University of Sheffield, South Yorkshire, S3 7RH

    7 shared publications
  • A. Scarff

    12 Department of Physics and Astronomy, University of Sheffield, South Yorkshire, S3 7RH, United Kingdom

    6 shared publications
  • T. Crane

    11 AWE plc, Aldermaston, Reading, Berkshire, RG7 4PR, United Kingdom

    6 shared publications
  • A.C. Ezeribe

    12 Department of Physics and Astronomy, University of Sheffield, South Yorkshire, S3 7RH, United Kingdom

    5 shared publications
  • C. Eldridge

    Univ Sheffield, Dept Phys & Astron, Sheffield S3 7RH, South Yorkshire, England

    5 shared publications
  • R.R. Marcelo Gregorio

    15 School of Physical and Chemical Sciences, Queen Mary University of London, E1 4NS, United Kingdom

    4 shared publications

Latest Publications

  • Open Access

    High negative ion gain MMThGEM-Micromegas detector for directional dark matter searches

    by A.G. McLean, S. Higashino, R.R. Marcelo Gregorio, K. Miuchi, N.J.C. Spooner

    Low pressure gaseous Negative Ion Time Projection Chambers (NITPCs) have been used previously by the DRIFT experiment to search for a directional Dark Matter (DM) signature. The main challenge with using a Negative Ion Drift (NID) gas target is the significantly lower gas gains to which they are typically limited. Recently, a MMThGEM device has been successfully demonstrated as an excellent gain stage device in the NID gas SF 6 ; capable of producing gas gains comparable with the electron drift gas CF 4 . The next major challenge is to extend this high gain capability to multi-dimensional readout for the purpose of particle track reconstruction. The MMThGEM is therefore ideal for coupling to a strip readout detector like a Micromegas to achieve a high gain multi-dimensional Negative Ion (NI) readout plane, which is potentially suitable for the scale up required by future searches proposed by the CYGNUS consortium. In this paper, the first high gain demonstration of such a MMThGEM-Micromegas detector in low pressure SF 6 is described. This includes detector characterisation in a small test vessel resulting in the largest NI gas gain ever reported, 1.22 ± 0.08 × 10 5 , and directionality with alpha particles. Finally, this gain characterisation and tracking capability is leveraged to measure the energy and range of events, and identify those consistent with Nuclear Recoils (NRs), in a large cubic metre scale volume of SF 6 for the first time.

  • Open Access

    Direct in-chamber radon-220 (thoron) emanation measurements for rare-event physics experiments

    by R.R. Marcelo Gregorio, F. Dastgiri, A. Basharina-Freshville, V.U. Bashu, A. Cottle, L.J. Bignell, C. Ghag, G.J. Lane, A.G. McLean, N.J.C. Spooner

    Measuring radon emanation from detector materials is a key method for controlling radon, a significant background in rare-event physics experiments. Methods for measuring radon emanation are well-established but have predominantly focused on the 222 Rn isotope, the dominant radon isotope for these backgrounds. However, measurements of 220 Rn (thoron), the second most abundant radon isotope, remain relatively unexplored. 220 Rn emanation measurements are challenging because the 220 Rn must be transferred from the emanation chamber to the active detector within its short 55 s half-life. In this study, a direct in-chamber approach for measuring 220 Rn emanation is presented in which the sample is placed directly within the active detector chamber, thereby minimising losses during transfer. The method was demonstrated with a DURRIDGE RAD8 electrostatic radon detector, which measured 220 Rn emanation from low-activity thoriated rods with an activity of 76 ± 20 mBq. Compared with a conventional flowthrough 220 Rn emanation setup, the in-chamber method increased sensitivity by a factor of 3. Using helium as the carrier gas provided a further sensitivity increase, giving an overall sensitivity gain of ∼ 5. These results indicate that in-chamber 220 Rn emanation measurements provide an effective tool for low-background experiments and have the potential to accelerate radon studies by exploiting the shorter half-life of 220 Rn.

  • Open Access

    Charge amplification in low pressure CF4:SF6:He mixtures with a multi-mesh ThGEM for directional dark matter searches

    by F.D. Amaro, E. Baracchini, L. Benussi, S. Bianco, F. Borra, C. Capoccia, M. Caponero, D.S. Cardoso, G. Cavoto, I.A. Costa, et al.

    The CYGNO collaboration is developing next generation directional Dark Matter (DM) detection experiments, using gaseous Time Projection Chambers (TPCs), as a robust method for identifying Weakly Interacting Massive Particles (WIMPs) below the Neutrino Fog. SF6 is potentially ideal for this since it provides a high fluorine content, enhancing sensitivity to spin-dependent interactions and, as a Negative Ion Drift (NID) gas, reduces charge diffusion leading to improved positional resolution. CF4, although not a NID gas, has also been identified as a favourable gas target as it provides a scintillation signal which can be used for a complimentary light/charge readout approach. These gases can operate at low pressures to elongate Nuclear Recoil (NR) tracks and facilitate directional measurements. In principle, He could be added to low pressure SF6/CF4 without significant detriment to the length of 16S, 12C, and 19F recoils. This would improve the target mass, sensitivity to lower WIMP masses, and offer the possibility of atmospheric operation; potentially reducing the cost of a containment vessel. In this article, we present gas gain and energy resolution measurements, taken with a Multi-Mesh Thick Gaseous Electron Multiplier (MMThGEM), in low pressure SF6 and CF4:SF6 mixtures following the addition of He. We find that the CF4:SF6:He mixtures tested were able to produce gas gains on the order of 104 up to a total pressure of 100 Torr. These results demonstrate an order of magnitude improvement [1] in charge amplification in NID gas mixtures with a He component.


  • Open Access

    Charge amplification in sub-atmospheric CF4:He mixtures for directional dark matter searches

    by A.G. McLean, N.J.C. Spooner, T. Crane, C. Eldridge, A.C. Ezeribe, R.R. Marcelo Gregorio, A. Scarff

    Low pressure gaseous Time Projection Chambers (TPCs) are a viable technology for directional Dark Matter (DM) searches and have the potential for exploring the parameter space below the neutrino fog [1,2]. Gases like CF4 are advantageous because they contain flourine which is predicted to have heightened elastic scattering rates with a possible Weakly Interacting Massive Particle (WIMP) DM candidate [3,4,5]. The low pressure of CF4 must be maintained, ideally lower than 100 Torr, in order to elongate potential Nuclear Recoil (NR) tracks which allows for improved directional sensitivity and NR/Electron Recoil (ER) discrimination [6]. Recent evidence suggests that He can be added to heavier gases, like CF4, without significantly affecting the length of 12C and 19F recoils due to its lower mass. Such addition of He has the advantage of improving sensitivity to lower mass WIMPs [1]. Simulations can not reliably predict operational stability in these low pressure gas mixtures and thus must be demonstrated experimentally. In this paper we investigate how the addition of He to low pressure CF4 affects the gas gain and energy resolution achieved with a single Thick Gaseous Electron Multiplier (ThGEM).

  • Open Access

    Molecular sieve vacuum swing adsorption purification and radon reduction system for gaseous dark matter and rare-event detectors

    by R.R. Marcelo Gregorio, N.J.C. Spooner, F. Dastgiri, A.C. Ezeribe, G. Lane, A.G. McLean, K. Miuchi, H. Ogawa

    In the field of directional dark matter experiments SF6 has emerged as an ideal target gas. A critical challenge with this gas, and with other proposed gases, is the effective removal of contaminant gases. This includes radon which produce unwanted background events, but also common pollutants such as water, oxygen and nitrogen, which can capture ionisation electrons, resulting in loss of detector gas gain over time. We present here a novel molecular sieve (MS) based gas recycling system for the simultaneous removal of both radon and common pollutants from SF6. The apparatus has the additional benefit of minimising gas required in experiments and utilises a Vacuum Swing Adsorption (VSA) technique for continuous, long-term operation. The gas system's capabilities were tested with a 100 L low-pressure SF6 Time Projection Chamber (TPC) detector. For the first time, we present a newly developed low-radioactive MS type 5 Å. This material was found to emanate radon at 98% less per radon captured compared to commercial counterparts, the lowest known MS emanation at the time of writing. Consequently, the radon activity in the TPC detector was reduced, with an upper limit of less than 7.2 mBq at a 95% confidence level (C.L.). Incorporation of MS types 3 Å and 4 Å to absorb common pollutants was found successfully to mitigate against gain deterioration while recycling the target gas.


  • Open Access

    Gas gains over 104 and optimisation using 55Fe X-rays in low pressure SF6 with a novel Multi-Mesh ThGEM for directional dark matter searches

    by A.G. McLean, N.J.C. Spooner, T. Crane, C. Eldridge, A.C. Ezeribe, R.R. Marcelo Gregorio, A. Scarff

    The Negative Ion Drift (NID) gas SF6 has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the gas means that it is more difficult to achieve significant gas gains with regular Thick Gaseous Electron Multipliers (ThGEMs). Typically, the maximum attainable gas gain in SF6 and other Negative Ion (NI) gas mixtures, previously achieved with an 55Fe X-ray source or electron beam, is on the order of 103 [1,2,3,4]; whereas electron drift gases like CF4 and similar mixtures are readily capable of reaching gas gains on the order of 104 or greater [5,9,7,8,6]. In this paper, a novel two stage Multi-Mesh ThGEM (MMThGEM) structure is presented. The MMThGEM was used to amplify charge liberated by an 55Fe X-ray source in 40 Torr of SF6. By expanding on previously demonstrated results [10], the device was pushed to its sparking limit and stable gas gains up to ˜50000 were observed. The device was further optimised by varying the field strengths of both the collection and transfer regions in isolation. Following this optimisation procedure, the device was able to produce a maximum stable gas gain of ˜90000. These results demonstrate an order of magnitude improvement in gain with the NID gas over previously reported values and ultimately benefits the sensitivity of a NITPC to low energy recoils in the context of a directional DM search.


  • Open Access

    Charge Amplification in Sub-atmospheric CF4:He Mixtures for Directional Dark Matter Searches

    by A. G. McLean, N. J. C. Spooner, T. Crane, C. Eldridge, A. C. Ezeribe, R. R. Marcelo Gregorio, A. Scarff

    Low pressure gaseous Time Projection Chambers (TPCs) are a viable technology for directional Dark Matter (DM) searches and have the potential for exploring the parameter space below the neutrino fog. Gases like CF4 are advantageous because they contain flourine which is predicted to have heightened elastic scattering rates with a possible Weakly Interacting Massive Particle (WIMP) DM candidate. The low pressure of CF4 must be maintained, ideally lower than 100 Torr, in order to elongate potential Nuclear Recoil (NR) tracks which allows for improved directional sensitivity and NR/Electron Recoil (ER) discrimination. Recent evidence suggests that He can be added to heavier gases, like CF4, without significantly affecting the length of 12C and 19F recoils due to its lower mass. Such addition of He has the advantage of improving sensitivity to lower mass WIMPs. Simulations can not reliably predict operational stability in these low pressure gas mixtures and thus must be demonstrated experimentally. In this paper we investigate how the addition of He to low pressure CF4 affects the gas gain and energy resolution achieved with a single Thick Gaseous Electron Multiplier (ThGEM).

  • Open Access

    Gas Gains Over 10$^4$ and Optimisation using $^{55}$Fe X-rays in Low Pressure SF$_6$ with a Novel Multi-Mesh ThGEM for Directional Dark Matter Searches

    by A. G. McLean, N. J. C. Spooner, T. Crane, C. Eldridge, A. C. Ezeribe, R. R. Marcelo Gregorio, A. Scarff

    The Negative Ion Drift (NID) gas SF$_6$ has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the gas means that it is more difficult to achieve significant gas gains with regular Thick Gaseous Electron Multipliers (ThGEMs). Typically, the maximum attainable gas gain in SF$_6$ and other Negative Ion (NI) gas mixtures, previously achieved with an $^{55}$Fe X-ray source or electron beam, is on the order of $10^3$; whereas electron drift gases like CF$_4$ and similar mixtures are readily capable of reaching gas gains on the order of $10^4$ or greater. In this paper, a novel two stage Multi-Mesh ThGEM (MMThGEM) structure is presented. The MMThGEM was used to amplify charge liberated by an $^{55}$Fe X-ray source in 40 Torr of SF$_6$. By expanding on previously demonstrated results, the device was pushed to its sparking limit and stable gas gains up to $\sim$50000 were observed. The device was further optimised by varying the field strengths of both the collection and transfer regions in isolation. Following this optimisation procedure, the device was able to produce a maximum stable gas gain of $\sim$90000. These results demonstrate an order of magnitude improvement in gain with the NID gas over previously reported values and ultimately benefits the sensitivity of a NITPC to low energy recoils in the context of a directional DM search.

  • Open Access

    Directional dark matter readout with a novel multi-mesh ThGEM for SF6 negative ion operation

    by C. Eldridge, N.J.C. Spooner, A.G. McLean, J. Burns, T. Crane, A.C. Ezeribe, R.R. Marcelo Gregorio, A. Scarff

    Direct searches for Weakly Interacting Massive Particle (WIMP) dark matter could greatly benefit from directional measurement of the expected induced nuclear recoils. Gas-based Time Projection Chambers (TPCs) offer potential for this, opening the possibility of measuring WIMP signals below the so-called neutrino floor but also of directional measurement of recoils induced by neutrinos from the Sun, for instance as proposed by the CYGNUS collaboration. Presented here for the first time are results from a Multi-Mesh Thick Gas Electron Multiplier (MM-ThGEM) using negative ion gases for operation with such a directional dark matter TPC. Negative ion drift gases are favoured for directionality due to their low diffusion characteristics. The multiple internal mesh structure is designed to provide a high gain amplification stage when coupled to future large area Micromegas, strip or pixel charge readout planes. Experimental results and simulations are presented of MM-ThGEM gain and functionality using low pressure pure CF4, SF6 and SF6:CF4 mixtures irradiated with alpha particles and 55Fe x-rays. The concept is found to work well, providing stable operation with gains over 103 in pure SF6.