YCYu-Jie Chen

Yu-Jie Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yu-Jie Chen has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Bo Yu

    State Key Laboratory of Low Carbon Catalysis and Carbon Dioxide Utilization, School of Petroleum Engineering, Yangtze University, Wuhan 430100, China

    12 shared publications
  • Dongliang Sun

    School of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617, China

    12 shared publications
  • Wei Lu

    State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China

    11 shared publications
  • Ge-Ge Song

    School of Chemical Engineering and Technology, Xi'an Jiaotong University, Shaanxi 710049, China

    8 shared publications
  • Kong Ling

    Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education, School of Energy and Power Engineering, Xi'an Jiaotong University, Shaanxi 710049, China

    8 shared publications
  • Bohong Wang

    National & Local Joint Engineering Research Center of Harbor Oil & Gas Storage and Transportation Technology/Zhejiang Key Laboratory of Petrochemical Environmental Pollution Control, Zhejiang Ocean University, No. 1 Haida South Road, Zhoushan 316022, China

    4 shared publications

Latest Publications

  • The effects of aspect ratio on the heat transfer characteristics of boiling mini-channel flow

    by Wei Lu, Yujie Chen, Benxi Zhang, Bo Yu, Dongliang Sun, Bohong Wang, Yanru Yang, Xiaodong Wang

    Flow boiling demonstrates superior heat transfer performance and holds significant potential for thermal management applications. In this study, the great effects of aspect ratios of mini-channel on flow boiling heat transfer are reported by the numerical simulation method. Regarding the heat transfer coefficient (HTC), a boiling number threshold of 5.0 × 10−4 is obtained. Below this value, bubble detachment is not yet constrained by the channel, reducing the dry patches and providing better heat transfer at larger aspect ratios. Above this threshold, boiling becomes more intense, bubble size increases, making detachment easier in smaller aspect ratios, which show superior heat transfer performance. For the critical heat flux (CHF), at a flow rate of 0.1 m/s, the CHF for smaller aspect ratios is 77.78% higher than for larger aspect ratios. As the flow velocity increases, inertial forces begin to dominate bubble behavior, reducing the influence of channel size effects, and the differences in CHF gradually decrease. When the flow velocity exceeds 0.5 m/s, bubble behavior becomes similar, and the difference in CHF drops to less than 10%. This research highlights key parameters for optimizing mini-channel design, promoting the refinement and development of mini-channel structures.


  • Open Access

    A circle-based interface reconstruction algorithm based on the coupled volume-of-fluid and level set method

    by Yujie Chen, Junhua Gong, Wei Lu, Bohong Wang, Dongliang Sun, Bo Yu, Wei Zhang, Wenquan Tao

    The interface tends to behave as a circular shape under the effect of surface tension in the two-dimensional two-phase fluid flow. In this study, based on the coupled volume-of-fluid and level set (VOSET) method, an accurate circle-based interface reconstruction (CIR) algorithm for structured meshes is proposed, which features a straightforward implementation procedure. A portion of the standard circle is employed to approximate the curve interface, without the need for complex classification, coordinate transformation, and equation transformation. The radius of this circle is computed simply by the curvature and signed distance at the mixed cell center, and the center of this circle is determined using a straightforward dichotomy method under the mass conservation constraints. Results indicate that the coupled VOSET and CIR (VOSET-CIR) method maintains superior computational accuracy in the signed distance, interface curvature, and dynamic interface reconstruction compared to the coupled VOSET and piecewise linear interface calculation (VOSET-PLIC) method, with accuracy improvements ranging from 34% to 1490% across different test cases. Furthermore, the VOSET-CIR method outperforms the efficient least squares volume-of-fluid interface reconstruction (ELVIRA) and PLIC algorithms in reconstructing random circles and surpasses the quadratic spline based interface reconstruction (QUASI) algorithm in reconstructing random squares. In terms of computational efficiency, except for the initial PLIC algorithm, the time costs of the VOSET-CIR method are substantially lower than those of the ELVIRA and QUASI algorithms, as well as the VOSET-PLIC method.


  • Numerical study of flow boiling heat transfer in a mini-channel under hyper-gravity

    by Wei Lu, Zhanru Zhang, Yujie Chen, Bohong Wang, Bo Yu, Dongliang Sun, Wei Zhang, Yanru Yang, Xiaodong Wang

    Gravity plays a crucial role in influencing bubble behavior and heat transfer in flow boiling, and its impact can vary significantly in aerospace settings. Therefore, this study aims to numerically investigate flow boiling heat transfer in a rectangular mini-channel under hyper-gravity conditions, specifically at 12 times the normal gravity. To accomplish this, a coupled volume-of-fluid and level set method is employed, taking into account fluid-solid conjugated heat transfer as well as a nucleus site density model derived from experimental data. By reproducing the flow pattern and heat transfer characteristics under different heat flux and flow rate conditions, the study unveils the effects of hyper-gravity on flow boiling heat transfer. When the flow rate is lower under hyper-gravity conditions, a notable phenomenon occurs wherein numerous bubbles detach from the heating wall and coalesce into a vapor film at the top of the mini-channel due to increased buoyancy. In contrast, under normal gravity, bubbles merge and slide on the heating wall, leading to the formation of a dry patch below. Consequently, hyper-gravity results in a lower wall superheat, and the disparity in average wall superheat between normal and high gravities escalates as the added heat flux rises. Notably, in the hyper-gravity environment, the frequent detachment of bubbles in the middle and downstream sections of the mini-channel leads to an initial increase in wall superheating, followed by a plateau along the flow direction. As the flow rate increases, the inertial force intensifies. However, intriguingly, the discrepancy in flow boiling heat transfer between normal and high gravities does not exhibit a monotonic decrease with the increasing flow rate. This behavior can be attributed to the pressing of more bubbles onto the heating wall under normal gravity, resulting in the formation of dry patches at high velocities.


  • Open Access

    Effect of Channel Aspect Ratio on Flow Boiling in Mini-Channels

    by Wei Lu, Yujie Chen, Bo Yu, Dongliang Sun, Wei Zhang, Yanru Yang, Xiaodong Wang

    Flow boiling offers superior heat transfer performance compared to single-phase flow, therefore holding significant potential for application in thermal management. In mini-channel applications, due to their narrow dimensions, the size characteristics of the channel have a particularly notable impact on bubble dynamics and flow boiling heat transfer performance. This study employs the VOSET method to explore the impact of different aspect ratios (1:3, 1:2, 1:1, 2:1, 3:1) on the heat transfer performance of mini-channels. By maintaining a consistent equivalent diameter across the channels, the study aims to unveil the mechanism by which aspect ratios affect heat transfer performance under various flow velocities and heat flux densities. The results indicate that at lower flow velocities, channels with smaller aspect ratios lead to difficulty in bubble detachment, with bubbles being pressed against the heating surface by the top of the channel, thus forming larger dry patch areas and significantly reducing heat transfer performance. Conversely, under conditions of larger aspect ratios, bubbles are confined by the side walls of the channel, which affects the replenishment ability of the thermal wall and similarly leads to a decrease in heat transfer performance. Therefore, this study identifies an optimal aspect ratio, under which the influence of the walls on bubble detachment is minimized, achieving the best heat transfer coefficient. Additionally, as flow velocity increases, bubble size decreases, and their behavior is dominated by inertial forces, which causes the heat transfer differences induced by aspect ratios to gradually diminish. The findings of this study offer important guidance for the design and optimization of mini-channels, helping to determine the optimal aspect ratio to achieve maximized heat transfer performance during the design process.

  • Open Access

    Effects of heterogeneous nucleation model on computational fluid dynamics simulation of flow boiling heat transfer in the mini-channel

    by Yujie Chen, Mingyang Ji, Bo Gao, Bohong Wang, Wei Li, Kaituo Jiao, Dongliang Sun, Bo Yu

    Bubble nucleation is the initial stage of flow boiling and plays an important role in boiling heat transfer. However, bubble nucleation occurs at a microscopic scale, rendering it challenging for the macroscopic computational fluid dynamics method to realistically simulate this intricate process. In this paper, based on the coupled volume-of-fluid and level set method, a heterogeneous nucleation model is improved and conducted to simulate the subcooled flow boiling in a rectangular mini-channel, considering these conditions both in the presence and absence of a microlayer. The coefficient of the original heterogeneous nucleation model is adjusted across a range from 0.1 to 10.0 times its previous value to establish multiple new nucleation models for illustrating their effects on flow patterns and heat transfer characteristics. For flow boiling without a microlayer, when the coefficient of the original heterogeneous nucleation model is halved, the nucleate boiling intensity upstream of the channel diminishes, resulting in a reduction in the heat transfer coefficient. Nevertheless, this alteration mitigates the formation of slug flow and the appearance of dry patches near the channel outlet, consequently averting a sharp increase in outlet wall superheat. Quantitatively, relative differences of 23.83% and 90.48% in average and local maximum wall superheat are observed, respectively. In contrast, the presence of a very thin microlayer beneath the growing and slipping bubble in flow boiling with a microlayer is notable. This microlayer quickly evaporates, dissipating more than 77% of the input heat flux and substantially expanding the bubble volume. Consequently, under identical wall superheat conditions, the influence of variations in the number of activated bubbles induced by different heterogeneous nucleation models on heat transfer and flow patterns in flow boiling is significantly attenuated. Specifically, when the difference in nucleus site density remains within a tenfold range, the differences in the average and maximum wall superheat are limited to just 16.78% and 33.86%, respectively. Concerning flow boiling in a mini-channel featuring a microlayer, the simulation results verify that large deviations in the activated bubble number have few effects on the flow pattern and wall superheat, greatly reducing heterogeneous nucleation model requirement and promoting the numerical study of flow boiling.


  • Open Access

    Fast Prediction of the Temperature Field Surrounding a Hot Oil Pipe Using the POD-BP Model

    by Feng Yan, Kaituo Jiao, Chaofei Nie, Dongxu Han, Qifu Li, Yujie Chen

    The heat transfer assessment of a buried hot oil pipe is essential for the economical and safe transportation of the pipeline, where the basis is to determine the temperature field surrounding the pipe quickly. This work proposes a novel method to efficiently predict the temperature field surrounding a hot oil pipe, which combines the proper orthogonal decomposition (POD) method and the backpropagation (BP) neural network, named the POD-BP model. Specifically, the BP neural network is used to establish the mapping relationship between spectrum coefficients and the preset parameters of the sample. Compared with the classical POD reduced-order model, the POD-BP model avoids solving the system of reduced-order governing equations with spectrum coefficients as variables, thus improving the prediction speed. Another advantage is that it is easy to implement and does not require tremendous mathematical derivation of reduced-order governing equations. The POD-BP model is then used to predict the temperature field surrounding the hot oil pipe, and the sample matrix is obtained from the numerical results using the finite volume method (FVM). In validation cases, both steady and unsteady states are investigated, and multiple boundary conditions, thermal properties, and even geometry parameters (different buried depths and pipe diameters) are tested. The mean errors of steady and unsteady cases are 0.845~3.052% and 0.133~1.439%, respectively. Appealingly, almost no time, around 0.008 s, is consumed in predicting unsteady situations using the proposed POD-BP model, while the FVM requires a computational time of 70 s.


  • 10.1063/5.0115599.2

    by Yu-Jie Chen, Ge-Ge Song, Kong Ling, Bo Yu, Dongliang Sun, Wei Lu

    Under a low flow rate, gravity may become prominent for bubble behavior and heat transfer of flowing boiling because of the weakness of drag force from liquid, and its effect changes with the inclination angle of the mini-channel but without consensus. In this paper, based on a reasonable nucleus site density model and considering conjugate heat transfer, the coupled volume-of-fluid and level set method is adopted to study the subcooled flow boiling in an inclined three-dimensional rectangular mini-channel (0°–180°) with a characteristic size of 1.0 mm at a low flow rate of 88.8 kg m−2 s−1. The inclination angle is found to have a slight effect on the flow boiling, which is different from the conclusion drawn based on the traditional-macro channel. A bubbly flow appears when a heat flux of 300 kW/m2 is added. An unconventional impact force is proposed, which presses large bubbles to slip along the heating wall, with slight differences in the flow pattern under different inclination angles. When the inclination angle is close to 0°, the upstream small/medium bubbles leave the heating wall under gravitational effects, which is conducive to heat transfer. As the inclination angle approaches 90°, gravity pushes the large bubbles downstream to leave the channel, favoring the rewetting of the dry patches below. These two positive effects fail as the inclination angle approaches 180°, leading to slightly worse overall heat exchange efficiency. However, the maximum differences in the average and local wall superheating of the mini-channel are only 8.4% and 22.5%, respectively, across the range of inclination angles because the flow pattern remains similar under the effect of the impact force. In addition, the effect of inclination angle on flow boiling becomes weaker with the increase in heat flux because of happening of slug flow.

  • 10.1063/5.0115599.4

    by Yu-Jie Chen, Ge-Ge Song, Kong Ling, Bo Yu, Dongliang Sun, Wei Lu

    Under a low flow rate, gravity may become prominent for bubble behavior and heat transfer of flowing boiling because of the weakness of drag force from liquid, and its effect changes with the inclination angle of the mini-channel but without consensus. In this paper, based on a reasonable nucleus site density model and considering conjugate heat transfer, the coupled volume-of-fluid and level set method is adopted to study the subcooled flow boiling in an inclined three-dimensional rectangular mini-channel (0°–180°) with a characteristic size of 1.0 mm at a low flow rate of 88.8 kg m−2 s−1. The inclination angle is found to have a slight effect on the flow boiling, which is different from the conclusion drawn based on the traditional-macro channel. A bubbly flow appears when a heat flux of 300 kW/m2 is added. An unconventional impact force is proposed, which presses large bubbles to slip along the heating wall, with slight differences in the flow pattern under different inclination angles. When the inclination angle is close to 0°, the upstream small/medium bubbles leave the heating wall under gravitational effects, which is conducive to heat transfer. As the inclination angle approaches 90°, gravity pushes the large bubbles downstream to leave the channel, favoring the rewetting of the dry patches below. These two positive effects fail as the inclination angle approaches 180°, leading to slightly worse overall heat exchange efficiency. However, the maximum differences in the average and local wall superheating of the mini-channel are only 8.4% and 22.5%, respectively, across the range of inclination angles because the flow pattern remains similar under the effect of the impact force. In addition, the effect of inclination angle on flow boiling becomes weaker with the increase in heat flux because of happening of slug flow.

  • 10.1063/5.0115599.1

    by Yu-Jie Chen, Ge-Ge Song, Kong Ling, Bo Yu, Dongliang Sun, Wei Lu

    Under a low flow rate, gravity may become prominent for bubble behavior and heat transfer of flowing boiling because of the weakness of drag force from liquid, and its effect changes with the inclination angle of the mini-channel but without consensus. In this paper, based on a reasonable nucleus site density model and considering conjugate heat transfer, the coupled volume-of-fluid and level set method is adopted to study the subcooled flow boiling in an inclined three-dimensional rectangular mini-channel (0°–180°) with a characteristic size of 1.0 mm at a low flow rate of 88.8 kg m−2 s−1. The inclination angle is found to have a slight effect on the flow boiling, which is different from the conclusion drawn based on the traditional-macro channel. A bubbly flow appears when a heat flux of 300 kW/m2 is added. An unconventional impact force is proposed, which presses large bubbles to slip along the heating wall, with slight differences in the flow pattern under different inclination angles. When the inclination angle is close to 0°, the upstream small/medium bubbles leave the heating wall under gravitational effects, which is conducive to heat transfer. As the inclination angle approaches 90°, gravity pushes the large bubbles downstream to leave the channel, favoring the rewetting of the dry patches below. These two positive effects fail as the inclination angle approaches 180°, leading to slightly worse overall heat exchange efficiency. However, the maximum differences in the average and local wall superheating of the mini-channel are only 8.4% and 22.5%, respectively, across the range of inclination angles because the flow pattern remains similar under the effect of the impact force. In addition, the effect of inclination angle on flow boiling becomes weaker with the increase in heat flux because of happening of slug flow.

  • 10.1063/5.0115599.7

    by Yu-Jie Chen, Ge-Ge Song, Kong Ling, Bo Yu, Dongliang Sun, Wei Lu

    Under a low flow rate, gravity may become prominent for bubble behavior and heat transfer of flowing boiling because of the weakness of drag force from liquid, and its effect changes with the inclination angle of the mini-channel but without consensus. In this paper, based on a reasonable nucleus site density model and considering conjugate heat transfer, the coupled volume-of-fluid and level set method is adopted to study the subcooled flow boiling in an inclined three-dimensional rectangular mini-channel (0°–180°) with a characteristic size of 1.0 mm at a low flow rate of 88.8 kg m−2 s−1. The inclination angle is found to have a slight effect on the flow boiling, which is different from the conclusion drawn based on the traditional-macro channel. A bubbly flow appears when a heat flux of 300 kW/m2 is added. An unconventional impact force is proposed, which presses large bubbles to slip along the heating wall, with slight differences in the flow pattern under different inclination angles. When the inclination angle is close to 0°, the upstream small/medium bubbles leave the heating wall under gravitational effects, which is conducive to heat transfer. As the inclination angle approaches 90°, gravity pushes the large bubbles downstream to leave the channel, favoring the rewetting of the dry patches below. These two positive effects fail as the inclination angle approaches 180°, leading to slightly worse overall heat exchange efficiency. However, the maximum differences in the average and local wall superheating of the mini-channel are only 8.4% and 22.5%, respectively, across the range of inclination angles because the flow pattern remains similar under the effect of the impact force. In addition, the effect of inclination angle on flow boiling becomes weaker with the increase in heat flux because of happening of slug flow.