Rachel E. Moss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rachel E. Moss has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Rodolfo E. Perez-Roa
Pontificia Univ Catolica Chile, Dept Chem & Bioproc Engn, Sch Engn, Santiago, Chile
2 shared publications Marc A. Anderson
University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
1 shared publication- Marc A. Anderson
Electrochemical Processes Unit, IMDEA Energy Institute, Ave. Ramón de la Sagra 3, Mostoles Technology Park, E28935 Mostoles, Spain, Tel. +34 917 371132, +1 608 2622674; Fax: +34 917 371 140, +1 608 2620454; Environmental Chemistry & Technology Program, University of Wisconsin-Madison, Wisconsin-Madison 53706, WI, USA Fax
1 shared publication
Latest Publications
- 30 April 2013
- Published by Elsevier in Electrochimica Acta
- Vol. 104, 314-321
Electrochemical response of titania, zirconia, and alumina electrodes to phosphate adsorption
- 30 April 2013
- Published by Elsevier in Electrochimica Acta
- Vol. 104, 314-321
Electrochemical response of titania, zirconia, and alumina electrodes to phosphate adsorption
- 5 December 2012
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 160 (2) , H105-H112
Effects of pH on Phosphate Adsorption to Hematite as Studied with Cyclic Voltammetry and Electrochemical Impedance Spectroscopy
Nanoporous hematite (α-Fe2O3) coated electrodes were applied for the investigation of the electrochemical effects of pH on adsorption of the phosphate ion to iron oxide in concentrations commonly found in natural waters. The hematite electrode was tested with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods in NaClO4 solution and in 10−8 – 10−4 M phosphate over the pH range 6.00 – 8.75. In cyclic voltammograms, the current features attributed to specific adsorption of H+ or OH− were accentuated by phosphate addition. Impedance studies indicated that hematite behaved like a blocking electrode with deviations to blocking behavior occurring at higher pH and with increased phosphate. Resultant spectra were modeled with an analog electric circuit with a resistor in series with three parallel lines consisting of resistive, capacitive, and constant phase elements (CPEs) highlighting processes over sections of the applied EIS frequency range. This analysis of the phosphate-hematite system may assist with the production of an electrochemical sensor for phosphate at environmentally relevant pH.
- 5 December 2012
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 160 (2) , H105-H112
Effects of pH on Phosphate Adsorption to Hematite as Studied with Cyclic Voltammetry and Electrochemical Impedance Spectroscopy
Nanoporous hematite (α-Fe2O3) coated electrodes were applied for the investigation of the electrochemical effects of pH on adsorption of the phosphate ion to iron oxide in concentrations commonly found in natural waters. The hematite electrode was tested with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods in NaClO4 solution and in 10−8 – 10−4 M phosphate over the pH range 6.00 – 8.75. In cyclic voltammograms, the current features attributed to specific adsorption of H+ or OH− were accentuated by phosphate addition. Impedance studies indicated that hematite behaved like a blocking electrode with deviations to blocking behavior occurring at higher pH and with increased phosphate. Resultant spectra were modeled with an analog electric circuit with a resistor in series with three parallel lines consisting of resistive, capacitive, and constant phase elements (CPEs) highlighting processes over sections of the applied EIS frequency range. This analysis of the phosphate-hematite system may assist with the production of an electrochemical sensor for phosphate at environmentally relevant pH.