Seokho Nam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seokho Nam has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Yong Chu
Korea Institute of Fusion Energy (KFE), Daejeon, South Korea
5 shared publications- Hirofumi Yonekawa
KSATR Research Center, Korea Institute of Fusion Energy (KFE), Daejeon, Republic of Korea
4 shared publications Kaprai Park
KSATR Research Center, Korea Institute of Fusion Energy (KFE), Daejeon, Republic of Korea
4 shared publications- Kwang Pyo Kim
Korea Institute of Fusion Energy (KFE), Daejeon, South Korea
4 shared publications - Hee-Jae Ahn
National Fusion Research Institute, Daejeon, South Korea
3 shared publications - Hyunjung Lee
SC System Research Group, Korea Institute of Fusion Energy, Daejeon, South Korea
3 shared publications
Latest Publications
- 8 July 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 231
Proof-of-concept of heater-assisted variable dump resistor for fusion-magnet fast discharge system
- 8 July 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 231
Proof-of-concept of heater-assisted variable dump resistor for fusion-magnet fast discharge system
- 20 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-4
Mechanical Behavior of the KSTAR Magnets for Long-Pulse Discharges
The KSTAR superconducting magnet system confines and controls high-temperature plasma for nuclear fusion. To support sustained operation, long-pulse (LP) discharge experiments have been conducted in each campaign. During plasma operation, high TF coil currents generate the primary EM field, while varying CS and PF coil currents induce additional fields. These interactions produce significant EM forces on the magnets and support structures, leading to complex mechanical responses. Strain gauges and displacement sensors installed on the magnet system are used to monitor this behavior. By analyzing the measured data, the structural safety and stability of the system can be evaluated and managed. Over the past three years, the mechanical behavior during LP discharges has been systematically compared, and the reliability of the measurement systems has been validated.
- 20 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-4
Mechanical Behavior of the KSTAR Magnets for Long-Pulse Discharges
The KSTAR superconducting magnet system confines and controls high-temperature plasma for nuclear fusion. To support sustained operation, long-pulse (LP) discharge experiments have been conducted in each campaign. During plasma operation, high TF coil currents generate the primary EM field, while varying CS and PF coil currents induce additional fields. These interactions produce significant EM forces on the magnets and support structures, leading to complex mechanical responses. Strain gauges and displacement sensors installed on the magnet system are used to monitor this behavior. By analyzing the measured data, the structural safety and stability of the system can be evaluated and managed. Over the past three years, the mechanical behavior during LP discharges has been systematically compared, and the reliability of the measurement systems has been validated.
- 13 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Design and Testing of a High-Voltage Temperature Transducer for ITER High-Temperature Superconducting Current Leads
The high temperature superconducting current lead (HTSCL) plays key roles in supplying large current into the ITER superconducting magnets. To measure the temperature of HTSCL, which is cooled by helium gas, PT-100 sensors are installed at both the warm end of the HTS section and the room-temperature (RT) terminal. These sensors are exposed to high-voltage environment, depending on the type of ITER magnet. For instance, in the case of the Poloidal Field (PF) coils, the voltage along the HTSCL can reach up to 14 kV under normal operating conditions and up to 29 kV under fault conditions. Due to the high potential difference between the ITER magnets and ground, careful consideration must be given to the design of the temperature measurement interface and the analog signal conditioning from the sensors installed on the HTSCL. This paper presents the design, fabrication, and test results of the temperature measurement system specialized for HTSCL, referred to as the High-Voltage Temperature Transducer (HVTT). Based on the technical specifications provided by the ITER Organization (IO), functional test results, such as measurement accuracy and high-voltage test, are discussed. In addition, a long-term operation test conducted on the PF current leads of the KSTAR tokamak at the Korea Institute of Fusion Energy (KFE) is introduced.
- 13 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Design and Testing of a High-Voltage Temperature Transducer for ITER High-Temperature Superconducting Current Leads
The high temperature superconducting current lead (HTSCL) plays key roles in supplying large current into the ITER superconducting magnets. To measure the temperature of HTSCL, which is cooled by helium gas, PT-100 sensors are installed at both the warm end of the HTS section and the room-temperature (RT) terminal. These sensors are exposed to high-voltage environment, depending on the type of ITER magnet. For instance, in the case of the Poloidal Field (PF) coils, the voltage along the HTSCL can reach up to 14 kV under normal operating conditions and up to 29 kV under fault conditions. Due to the high potential difference between the ITER magnets and ground, careful consideration must be given to the design of the temperature measurement interface and the analog signal conditioning from the sensors installed on the HTSCL. This paper presents the design, fabrication, and test results of the temperature measurement system specialized for HTSCL, referred to as the High-Voltage Temperature Transducer (HVTT). Based on the technical specifications provided by the ITER Organization (IO), functional test results, such as measurement accuracy and high-voltage test, are discussed. In addition, a long-term operation test conducted on the PF current leads of the KSTAR tokamak at the Korea Institute of Fusion Energy (KFE) is introduced.
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Performance Evaluation of High Voltage Signal Conditioners for ITER Superconducting Magnets During Plasma Operation in the KSTAR Tokamak
Quench detection is critical to protect superconducting coils, especially in fusion superconducting magnets, due to enormous energy. A quench event can result in significant damage to fusion superconducting magnets. A High Voltage Signal Conditioner (HVSC) designed for quench voltage detection in the ITER superconducting magnet system has been developed collaboratively by the Korea Institute of Fusion Energy (KFE) and JH Engineering. Various types of HVSCs for ITER magnets and feeder systems were successfully designed, fabricated, and tested under high-voltage conditions and external magnetic fields simulating the fusion tokamak operational environment. However, long-term tests under actual tokamak plasma operation are essential to validate their reliability prior to deployment in ITER. Four types of HVSCs were installed and integrated with quench detection voltage taps of the Korea Superconducting Tokamak Advanced Research (KSTAR) superconducting magnets and bus lines. The long-term reliability tests of HVSCs were conducted during the 2024–2025 KSTAR campaign. The performance and reliability of the HVSCs were evaluated by comparing the recorded data with that of the KSTAR quench detection system.
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Performance Evaluation of High Voltage Signal Conditioners for ITER Superconducting Magnets During Plasma Operation in the KSTAR Tokamak
Quench detection is critical to protect superconducting coils, especially in fusion superconducting magnets, due to enormous energy. A quench event can result in significant damage to fusion superconducting magnets. A High Voltage Signal Conditioner (HVSC) designed for quench voltage detection in the ITER superconducting magnet system has been developed collaboratively by the Korea Institute of Fusion Energy (KFE) and JH Engineering. Various types of HVSCs for ITER magnets and feeder systems were successfully designed, fabricated, and tested under high-voltage conditions and external magnetic fields simulating the fusion tokamak operational environment. However, long-term tests under actual tokamak plasma operation are essential to validate their reliability prior to deployment in ITER. Four types of HVSCs were installed and integrated with quench detection voltage taps of the Korea Superconducting Tokamak Advanced Research (KSTAR) superconducting magnets and bus lines. The long-term reliability tests of HVSCs were conducted during the 2024–2025 KSTAR campaign. The performance and reliability of the HVSCs were evaluated by comparing the recorded data with that of the KSTAR quench detection system.
- 7 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Preliminary Study on 2 × 2 Parallel REBCO Stacks for 8 kA Current Leads
The integration of high-temperature superconducting (HTS) technology into fusion magnets necessitates advanced cabling solutions. This study presents the design and fabrication of a prototype Stacks-in-Conduit-Conductor (SICC) cable for a current lead. The current lead comprises a 2 × 2 parallel REBCO stacks, each consisting of 30 layered REBCO tapes. Three repeated experiments were conducted in a liquid nitrogen environment, applying a current of 8 kA. Voltage measurements revealed a negative voltage profile in the inter-stack voltages indicating effective current sharing among the REBCO stacks. Similar inter-stack voltage profiles were confirmed through simple circuit analysis. The loss across the REBCO stacks, including contact resistance, was measured to be less than 1 W. However, when a copper block was incorporated, the total loss of the current lead increased to approximately 5.6 W. Further improvements can be achieved by optimizing low-resistance termination joints and the volume of the copper block.
- 7 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Preliminary Study on 2 × 2 Parallel REBCO Stacks for 8 kA Current Leads
The integration of high-temperature superconducting (HTS) technology into fusion magnets necessitates advanced cabling solutions. This study presents the design and fabrication of a prototype Stacks-in-Conduit-Conductor (SICC) cable for a current lead. The current lead comprises a 2 × 2 parallel REBCO stacks, each consisting of 30 layered REBCO tapes. Three repeated experiments were conducted in a liquid nitrogen environment, applying a current of 8 kA. Voltage measurements revealed a negative voltage profile in the inter-stack voltages indicating effective current sharing among the REBCO stacks. Similar inter-stack voltage profiles were confirmed through simple circuit analysis. The loss across the REBCO stacks, including contact resistance, was measured to be less than 1 W. However, when a copper block was incorporated, the total loss of the current lead increased to approximately 5.6 W. Further improvements can be achieved by optimizing low-resistance termination joints and the volume of the copper block.
- Open Access
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
A High Voltage Signal Conditioner for the Quench Detection System of the ITER Superconducting Magnet
A Quench Detection System (QDS) will be installed for the ITER superconducting coils and feeder system. The objective of the QDS is to detect a quench in a superconducting device to protect the superconducting devices. This paper aims to provide a functional specification and qualification method for the QDS. In the baseline of I/O, the protection of magnet investment is defined to be carried out through electrical signal processing. Therefore, the primary function of the QDS is to detect the voltage drop across the unrecoverable normal zone in the superconducting system and send a trigger signal to the Central Interlock System to activate the protection circuit. Due to their pulsed operation, the superconducting systems of ITER will experience significant voltage variations, presenting a real challenge for quench detection. Detecting a quench, which typically produces around 0.1 V, among inductive signals in the range of several kilovolts, requires the implementation of digital techniques. Therefore, it is necessary to develop a system that can reliably detect quenches under high-voltage conditions. Over 56kV electrical isolation will be needed to develop the High Voltage Signal Conditioners (HVSC). This paper provides a summary of the status of HVSC.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Open AccessA High Voltage Signal Conditioner for the Quench Detection System of the ITER Superconducting Magnet
A Quench Detection System (QDS) will be installed for the ITER superconducting coils and feeder system. The objective of the QDS is to detect a quench in a superconducting device to protect the superconducting devices. This paper aims to provide a functional specification and qualification method for the QDS. In the baseline of I/O, the protection of magnet investment is defined to be carried out through electrical signal processing. Therefore, the primary function of the QDS is to detect the voltage drop across the unrecoverable normal zone in the superconducting system and send a trigger signal to the Central Interlock System to activate the protection circuit. Due to their pulsed operation, the superconducting systems of ITER will experience significant voltage variations, presenting a real challenge for quench detection. Detecting a quench, which typically produces around 0.1 V, among inductive signals in the range of several kilovolts, requires the implementation of digital techniques. Therefore, it is necessary to develop a system that can reliably detect quenches under high-voltage conditions. Over 56kV electrical isolation will be needed to develop the High Voltage Signal Conditioners (HVSC). This paper provides a summary of the status of HVSC.
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-4
Analysis of the Structural Behavior of the KSTAR TF Magnet for Safe Operation
Fully equipped with superconducting magnets, KSTAR has successfully conducted experimental campaigns for 15 years since 2008. The operating environment of KSTAR has become challenging due to long pulse durations, high temperatures, and large plasma currents. The 16 TF coils and 7 pairs of PF coils experience substantial electromagnetic forces during plasma discharge, given the high current and magnetic field, and the TF coil structure bears these loads. Strain gauges were installed to monitor the stresses in TF structures during cool-down and operation. This study involves electromagnetic and structural analyses. The finite element analysis model was developed, considering the strain gauge mounting positions and orientations, modified materials, and the as-built design. The structural behaviors observed during campaigns are compared with the analytical results.
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-4
Analysis of the Structural Behavior of the KSTAR TF Magnet for Safe Operation
Fully equipped with superconducting magnets, KSTAR has successfully conducted experimental campaigns for 15 years since 2008. The operating environment of KSTAR has become challenging due to long pulse durations, high temperatures, and large plasma currents. The 16 TF coils and 7 pairs of PF coils experience substantial electromagnetic forces during plasma discharge, given the high current and magnetic field, and the TF coil structure bears these loads. Strain gauges were installed to monitor the stresses in TF structures during cool-down and operation. This study involves electromagnetic and structural analyses. The finite element analysis model was developed, considering the strain gauge mounting positions and orientations, modified materials, and the as-built design. The structural behaviors observed during campaigns are compared with the analytical results.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Analysis of AC Losses in KSTAR Superconducting PF Magnets at Low Current Ramp Rates
To achieve nuclear fusion energy generation, continuous confinement of high-current and long-pulse plasma is necessary. KSTAR has been conducting experiments to achieve this goal. In order to maintain a steady state of plasma current, the superconducting magnets of the tokamak should also be operated stably, with heat controlled to a minimum. However, a slight increase in the outlet temperature of the KSTAR PF (poloidal field) magnet and current ripple were observed, particularly when the current ramp rate is 0.5 kA/s or less. In this range, the evaluated AC loss showed a different trend compared to the range where the current ramp rate was higher than 0.5 kA/s. The total heat load was observed to be significantly higher than the theoretical value, which means that losses must be added. This could be a hindering factor in the operation of long pulse plasmas. To ensure stable plasma control, the current operation of the superconducting magnet coils should be optimized and the AC losses should be applied accurately in the full range of ramp rate. In this article, the parametric study of AC losses based on the results of the PF coil in the low current ramp rate were analyzed to stably operate the superconducting magnet.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Analysis of AC Losses in KSTAR Superconducting PF Magnets at Low Current Ramp Rates
To achieve nuclear fusion energy generation, continuous confinement of high-current and long-pulse plasma is necessary. KSTAR has been conducting experiments to achieve this goal. In order to maintain a steady state of plasma current, the superconducting magnets of the tokamak should also be operated stably, with heat controlled to a minimum. However, a slight increase in the outlet temperature of the KSTAR PF (poloidal field) magnet and current ripple were observed, particularly when the current ramp rate is 0.5 kA/s or less. In this range, the evaluated AC loss showed a different trend compared to the range where the current ramp rate was higher than 0.5 kA/s. The total heat load was observed to be significantly higher than the theoretical value, which means that losses must be added. This could be a hindering factor in the operation of long pulse plasmas. To ensure stable plasma control, the current operation of the superconducting magnet coils should be optimized and the AC losses should be applied accurately in the full range of ramp rate. In this article, the parametric study of AC losses based on the results of the PF coil in the low current ramp rate were analyzed to stably operate the superconducting magnet.
- 3 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Preliminary Design Study on Non-Twisted HTS Conductor for Fusion Applications
Full transposition of superconducting wires within a conductor may not be a requirement for high temperature superconductor (HTS) magnet for fusion applications. Already, conduction-cooled 20 T model coil built with non-transposed HTS stacks has been demonstrated by Commonwealth Fusion Systems (CFS). Here, we discuss 3 possible stacked HTS cryogen-cooled conductor concepts for toroidal field (TF) magnet applications. The first one is somewhat like LTS conductors, the second, HTS stacks are capped by copper stabilizer, the last one, only stacks without copper. We simulate a simplified TF magnet model, 12 T, size of KSTAR, using the 3 conceptual HTS conductor designs. A comparative thermo-hydraulic analysis for a fast charging case has been carried out and its implications on HTS conductor design are further discussed.
- 3 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Preliminary Design Study on Non-Twisted HTS Conductor for Fusion Applications
Full transposition of superconducting wires within a conductor may not be a requirement for high temperature superconductor (HTS) magnet for fusion applications. Already, conduction-cooled 20 T model coil built with non-transposed HTS stacks has been demonstrated by Commonwealth Fusion Systems (CFS). Here, we discuss 3 possible stacked HTS cryogen-cooled conductor concepts for toroidal field (TF) magnet applications. The first one is somewhat like LTS conductors, the second, HTS stacks are capped by copper stabilizer, the last one, only stacks without copper. We simulate a simplified TF magnet model, 12 T, size of KSTAR, using the 3 conceptual HTS conductor designs. A comparative thermo-hydraulic analysis for a fast charging case has been carried out and its implications on HTS conductor design are further discussed.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design, Manufacture and Test of the Superconducting Quadrupole Triplet Magnet With Multi-Layered Direct-Wound Hexapole and Octupole Magnets
Currently, the Rare Isotope Science Project of the Institute for Basic Science has been constructing a heavy ion accelerator facility, named RAON. For rare isotope science research in Korea, the RAON includes two different types of facilities; one is the isotope separation on-line, and another is the in-flight system. In the in-flight system, several types of magnets are located: dipole, quadrupole, hexapole, and octupole magnets. Among them, a superconducting quadrupole triplet magnet (SQTM) system has been developed since 2018 and to date, all SQTM systems were manufactured and are being tested. In this paper, the design, manufacture, and commissioning test results of the SQTM systems for the RAON are presented. This magnet consists of five magnets of three different kinds: three quadrupole magnets, a hexapole magnet, and an octupole magnet. All magnets were made by low-temperature superconducting NbTi wires. For manufacturing the hexapole and octupole magnets with a multi-layer structure in a narrow space, the low-temperature superconducting wire was wound by the direct winding method.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design, Manufacture and Test of the Superconducting Quadrupole Triplet Magnet With Multi-Layered Direct-Wound Hexapole and Octupole Magnets
Currently, the Rare Isotope Science Project of the Institute for Basic Science has been constructing a heavy ion accelerator facility, named RAON. For rare isotope science research in Korea, the RAON includes two different types of facilities; one is the isotope separation on-line, and another is the in-flight system. In the in-flight system, several types of magnets are located: dipole, quadrupole, hexapole, and octupole magnets. Among them, a superconducting quadrupole triplet magnet (SQTM) system has been developed since 2018 and to date, all SQTM systems were manufactured and are being tested. In this paper, the design, manufacture, and commissioning test results of the SQTM systems for the RAON are presented. This magnet consists of five magnets of three different kinds: three quadrupole magnets, a hexapole magnet, and an octupole magnet. All magnets were made by low-temperature superconducting NbTi wires. For manufacturing the hexapole and octupole magnets with a multi-layer structure in a narrow space, the low-temperature superconducting wire was wound by the direct winding method.