INIgor Noenko

Igor Noenko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Igor Noenko has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Artificial Intelligence for Detection and Prevention of Separated Endodontic Instruments: A Scoping Review

    by Myroslav Goncharuk-Khomyn, Anastasiia Bilei, Igor Noenko, Mariya Kubatska, Liubov Bilyschuk, Anatoliy Bokoch

    Objective: Given the growing integration of artificial intelligence (AI) into dental diagnostics and clinical decision-support systems, a comprehensive assessment of existing publications addressing AI applications in the context of separated endodontic instruments is highly relevant. Such an assessment is essential for guiding future research priorities, promoting standardisation of reporting frameworks, and facilitating the transition from experimental AI prototypes towards clinically reliable tools aimed at minimising the incidence of intra-canal instrument separation. To critically evaluate the current landscape of AI models addressing endodontic instrument separation and to determine whether available models support a transition from post-separation detection towards predictive and preventive risk-assessment strategies. Methods: A qualitative evidence synthesis was conducted to summarise published studies evaluating AI and machine learning approaches related to separated endodontic instruments. This scoping review was structured in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) principles to ensure transparent study selection and reporting. Results were mapped and synthesised descriptively in 3 layers: study mapping, model mapping, and performance mapping. Results: Of the 8 eligible studies, only 2 (25%) were experimental investigations focused on preventive monitoring and prediction of endodontic instrument separation-related changes. Radiology-based detection was the dominant research direction, represented in 6 of 8 studies (75%). For periapical radiograph-based detection of separated instruments, AI-based models reported accuracy values ranging from 0.795 to 0.982, with the highest values observed for Mask Region-based convolutional neural network (accuracy =0.982) and YOLOv8 (accuracy=0.974). Performance was generally lower for panoramic radiographs. In the cone-beam computed tomography (CBCT)-based approach, true-positive detection was reported at 80.8%, although detailed comparative metrics were limited. Conclusion: Most available AI models related to endodontic instrument separation focus on digital radiological images, including both two-dimensional modalities (panoramic and periapical radiographs) and three-dimensional imaging (CBCT), whereas only a few studies have addressed monitoring the functional condition of instruments during their performance to verify potential critical changes related to the risk of separation. Convolutional neural networks were the dominant methodological approach, whereas traditional ML algorithms were used mainly in preventive experimental studies.

  • Open Access

    Oehlers′ Type II Dens Invaginatus Case Report: Outcome of Sequential Management With Primary Targeted Invagination Treatment

    by Igor Noenko, Myroslav Goncharuk-Khomyn, Mariya Kubatska

    Diversity of possible anatomical variations and configurations of dens invaginatus limits the possibility to conduct its complex treatment in a fully standardized protocol manner. Thus, the objective of the present case report was to approbate targeted approach to Type II dens invaginatus treatment, which may also be interpreted as part of a sequential management strategy with the intention to keep the vitality of a pulp within the main root canal in the first place. The present case report also opens a topic for discussion if “partial success” definition may be applicable for assessment of Type II dens invaginatus treatment outcomes. A 16‐year‐old patient referred to the dentist complaining of painful percussion in the area of Tooth 12. Clinical examination methods (visual examination, sensitivity testing, percussion, and probing) were used for the diagnostics of problematic Tooth 12. To confirm the diagnosis of dens invaginatus, Type II CBCT examination was held. The following treatment was provided: root canal treatment of the invaginated canal only in the first place, while root canal treatment of the main canal was planned to be provided on demand if needed. From the perspective of the presented case report, targeted endodontic treatment of invagination has resolved all the symptoms from the very beginning; meanwhile, the recurrence of the symptoms after some time was due to the involvement of the main root canal. Sequential management with primary targeted invagination treatment of Oehlers′ Type II dens invaginatus presented in this case report seems to be a possible approach for a carefully selected clinical situation aimed at minimizing the level of iatrogenic intervention; however, in the described case report, the end tooth required full endodontic treatment. Considering the risk of potential endodontic complications, development periodical screening of patients, who have undergone primary targeted invagination treatment, seems to be beneficial and reasonable to provide.

  • Open Access

    COMPARATIVE STUDY OF PROLONGED FLUORIDE ION RELEASE IN CONTEMPORARY DENTAL ENAMEL SEALANTS

    by Igor Noenko, Liudmyla Karpchuk, Vyacheslav Gurando, Viktoria Maryan-Yovbak, Andrii Kulish, Iurii Mochalov

    The objective of the study was to investigate the amount of long-term fluoride ion release from three materials (sealants) – “Fissurit FX”, “Clinpro™Sealant” and “Jen-Fissufil” in laboratory condition. Materials and methods: 4 standard samples from three modern photocomposite sealants for tooth enamel (“Fissurit FX” (VOCO), “Clinpro™Sealant” (3M™ ESPE™) and “Jen-Fissufil” (Jendental Ukraine LLC)) were polymerized according to instructions of producer and were placed in deionized water in plastic tubes. The conditions for manufacturing the samples were standardized, with the air temperature in the laboratory maintained at 22.0 ± 1.0 °C and the relative humidity at 50.0 ± 5.0%. These conditions comply with ISO 7489 standards. An amount of fluoride ions was studied using the electronic ionometer on 1st, 2nd, 3rd, 8th, 15th, 22nd and 32nd day of exposition in the deionized water tacked from plastic tube. Throughout the study duration, the tubes containing the samples were stored in a thermostat at a temperature of 37.00 ± 0.50°C Results: The all three enamel sealants selected for the study released fluoride ions for an extended period after polymerization, up to 30 days. The highest level of fluoride ion emission in distilled water occured on the next day after polymerization. This phenomenon can be attributed to the ongoing polymerization-depolymerization reactions within the material itself (composite conversion). “Fissurit FX” samples showed the highest F- release: 4.80 µg/cm² – day 1, and stabilized at 0.45 µg/cm² by day 14. Day 14 to 30 – from 0.13 to 0.17 µg/cm². “Jen-Fissufil” released 3.54 µg/cm² on 1st day, 0.74 µg/cm² on 7th, and 0.26 – 0.44 µg/cm² afterwards. “Clinpro™Sealant” – 1.84 µg/cm² of F- on 1st day, 0.58 on 2nd, 0.53 µg/cm² on 3rd. From 21st day – from 0.20 to 0.21 µg/cm². Comparison of the levels of fluoride ion release revealed a consistent pattern of element release within a month after polymerization for all materials: “Jen-Fissufil” exhibited the highest release, followed by “Clinpro™Sealant” and “Fissurit FX” with the lowest release. This trend was consistent throughout the month, except for the first day when “Fissurit FX” exhibited the highest release of fluoride ions. Conclusions: The enamel dental composite sealants “Fissurit FX”, “Clinpro™Sealant” and “Jen-Fissufil” are capable of emitting fluoride ions after use on enamel. The highest level of emission in distilled water occurs 24 hrs after polymerization, the process lasts more than 30 days in less amounts. Мета дослідження: дослідити обсяги тривалого виділення іонів фтору з трьох стоматологічних фотокомпозитних матеріалів для герметизації фісур та ямок (стоматологічних герметиків) – «Fissurit FX», «Clinpro™Sealant» і «Jen-Fissufil» в лабораторних умовах. Матеріали та методи. Відповідно до інструкцій виробника було підготовлено 4 стандартні полімеризовані зразки з кожного з трьох сучасних фотокомпозитних стоматологічних герметиків («Fissurit FX» (VOCO), «Clinpro™Sealant» (3М™ ESPE™) та «Jen-Fissufil» (ТОВ «Джендентал Україна»)) та поміщено в пластикові пробірки з дистильованою водою. Умови виготовлення зразків матеріалу були стандартизовані, температура повітря в лабораторії підтримувалась 22,0 ± 1,0 °С, відносна вологість 50,0 ± 5,0 %, що відповідає стандартам ISO 7489. Кількість виділених фторид-йонів досліджували за допомогою електронного іонометра на 1-шу, 2-гу, 3-тю, 8-му, 15-ту, 22-гу і 32-гу добу експозиції в дистильованій воді, відібраній із пластикової пробірки. Протягом усього часу дослідження пробірки зі зразками зберігалися в термостаті при температурі 37,00 ± 0,50 °С. Результати: усі три стоматологічні герметики, відібрані для дослідження, виділяли іони фтору протягом тривалого періоду після полімеризації, до 30 днів. Найвищий рівень емісії фторид-іонів у дистильованій воді спостерігався на наступний день після полімеризації. Це явище можна пояснити реакціями полімеризації-деполімеризації, що відбуваються в самому матеріалі (конверсія композиту). Зразки матеріалу «Fissurit FX» показали найвище вивільнення F-: 4,80 мкг/см² – 1 день, і стабілізувалося на 0,45 мкг/см² на 14 день. З 14 по 30 день – від 0,13 до 0,17 мкг/см². «Jen-Fissufil» виділив 3,54 мкг/см² на 1-й день, 0,74 мкг/см² на 7-й і 0,26–0,44 мкг/см² після. “Clinpro™Sealant” – 1,84 мкг/см² F- в 1-й день, 0,58 у 2-й, 0,53 мкг/см² у 3-й день. З 21 дня – від 0,20 до 0,21 мкг/см². Порівняння рівнів емісії йонів фтору виявило постійну картину вивільнення...


  • Open Access

    Role of endodontic treatment related signs for the forensic odontology practice considering real-life quality of comparable radiographs

    by Wayne Hirschowitz, Iurii Mochalov, Anastasia Biley, Igor Noenko, Myroslav Goncharuk-Khomyn

    Background. Real life quality of periapical radiographic images widely varies, while also periapical radiographs not always have been taken at the same angulation, especially in multirooted tooth cases, which in turn potentially may limit the value of obtained information received during endodontic treatment for the further comparative dental identification. Objective. To objectify possibility of using real-life quality periapical radiographs obtained during endodontic treatment for the comparative dental identification. Materials and Methods. Research was organized in the form of cross-sectional hospital-based study. Copies of ten pairs of selected radiographs were distributed for the Set 1 (simulation of ante-mortem images), which contained 10 radiographs of before root canal treatment, and Set 2 (simulation of post-mortem images), which contained 10 radiographs of after endodontic interventions. Set 1 and Set 2 images were randomized, and structured via Google Form, and five teaching assistants from the Department of Restorative Dentistry were asked to match the images through provided Google Form. Results. The range of 50-80% correct pre- and post-treatment images matching levels were registered among five operators. The mean correct matching level reached 68.0 ± 7.2%. Experience within endodontics seems to be valuable regressor regarding outcome performance (p < 0.05), while additional Radiology specialization did not significantly improved performance level for matching pre- and post-treatment images (p > 0.05). Operator graded 5 out of 10 images pair as relatively easy to match, 2 images – as moderately difficult to match, and 3 images – as hard to match (Fig. 3), while their agreement on the obtained above-mentioned scores reached 0.8. Conclusion. Significance of endodontics within forensic odontology field in most cases dictated by using the results of periapical radiology as evidences of ante-mortem origin, while also considering the fact of root canal morphology uniqueness and individualized endodontic treatment pattern consistency both ante- and post-mortem even under the influence of various disturbing factors. On the other hand identification role of endodontic signs may be diminished within the absence of proper quality radiographs, or when such were provided at critically different angulations, while also when endodontic-related evidences could not be supported by dental records.

  • Open Access

    COMPARATIVE STUDY OF FLEXURAL STRENGTH OF PHOTOCOMPOSITE DENTAL ENAMEL SEALANTS

    by I.V. Noenko, O.V. Pavlenko, I.O. Mochalov

    Background. Dental caries is a widespread worldwide disease of multifactorial genesis. The leading mechanism of its development is a long-term imbalance of the physiological balance between the inorganic component of the teeth hard tissues and the liquid biofilm formed on their surface, the predominance of the demineralization processes in hard tissues over the processes of remineralization. The use of dental enamel sealants has proven to be effective in preventing and reducing the intensity of dental caries. Modern bioactive polymer sealants for enamel contain such remineralizing agents as sodium fluoride, nanoamorphous calcium phosphate, beta-tricalcium phosphate, and particles of bioactive glass. For all dental composite filling materials, mechanical stability is one of the prerequisites for the long-term clinical success of restorations and fillings, and accordingly, temporary protective structures made of sealants. Aim: to compare the flexural strength and modulus of elasticity of three modern photocomposite enamel sealants. Materials and methods. In laboratory conditions for three modern photocomposite dental materials for sealing fissures and pits of enamel "Fissurit FX" (VOCO), "Clinpro™ Sealant" (3M™ ESPE™) and "Jen-Fissufil" (Jendental-Ukraine LLC) a flexural strength (three-point test) and elastic modulus were determined in accordance with the requirements of the international standard ISO 4049:2019. 6 samples of each material, polymerized and kept for a day in humid conditions, were examined. Results. The highest elastic modulus and flexural strength were in "Fissurit FX" – 5.17±0.80 GPa (M=5.00 GPa) and 130.07±7.75 MPa (M=127.81 MPa), respectively. In "Clinpro™ Sealant" the elastic modulus was 2.97±0.12 GPa (М=3.00 GPa), the flexural strength was 100.01±14.33 (М=96.73) MPa. In "Jen-Fissufil" the elastic modulus was 3.47±0.52 GPa (M=3.17 GPa), the flexural strength was 90.91±6.66 MPa (M=93.02 MPa). The studied indicators of all three materials exceeded the requirements of the international standard ISO 4049:2019. Conclusion. The performed studies showed high mechanical properties of all three dental sealants for enamel and that they have the potential to withstand long-term periodic masticatory load when functioning on the surface of teeth. Актуальність. Карієс зубів – це широко розповсюджене у всьому світі захворювання мультифакторіального генезу. Провідний механізм розвитку тривалий у часі дисбаланс фізіологічної рівноваги між неорганічним компонентом твердих тканин зубів і рідиною біоплівки, що формується на їх поверхні, переважання процесів демінералізації твердих тканин над процесами ремінералізації. Застосування стоматологічних емалевих герметиків показало себе ефективним в плані запобігання та зменшення інтенсивності карієсу зубів. Сучасні біоактивні полімерні герметики для емалі містять у своєму складі такі ремінералізуючі агенти, як фторид натрію, наноаморфний фосфат кальцію, бета-трикальцій фосфат, часточки біоактивного скла. Для всіх стоматологічних композитних пломбувальних матеріалів механічна стабільність є однією з передумов довгострокового клінічного успіху реставрацій та пломб, і відповідно й тимчасових захисних структур, що виготовляються з герметиків. Ціль: порівняти міцність на згинання та модуль еластичності у трьох сучасних фотокомпозитних емалевих герметиків. Матеріали та методи. Для трьох сучасних фотокомпозитних стоматологічних матеріалів для герметизації фісур та ямок емалі «Fissurit FX» (VOCO) , «Clinpro™Sealant» (3M™ ESPE™) та «Jen-Fissufil» (ТОВ «Джендентал-Україна»), – в лабораторних умовах було виконано визначення міцності на згинання (трьох-точковий тест) та модулю пружності за Юнгом відповідно до вимог міжнародного стандарту ISO 4049:2019. Було досліджено по 6 зразків кожного матеріалу, заполімеризованих та витриманих протягом доби у вологих умовах. Результати. Найвищими модуль пружності Юнга та міцність на згинання були у «Fissurit FX» – 5,17±0,80 ГПа (М=5,00 ГПа) та 130,07±7,75 МПа (М=127,81 МПа) відповідно. У «Clinpro™Sealant» модуль пружності за Юнгом становив 2,97±0,12 ГПа (М=3,00 ГПа), міцність на згинання – 100,01±14,33 (М=96,73) МПа. У «Jen-Fissufil» модуль пружності Юнга становив 3,47±0,52 ГПа (М=3,17 ГПа), міцність на згинання – 90,91±6,66 МПа (М=93,02 МПа). Досліджені показники у всіх трьох матеріалів перевищували вимоги міжнародного...

  • Open Access

    Artificial intelligence in endodontics: relevant trends and practical perspectives

    by Myroslav Goncharuk-Khomyn, Igor Noenko, Alessandro Leite Cavalcanti, Özkan Adigüzel, Artem Dubnov

    Background. Overall pool of studies regarding artificial intelligence (AI) implementation in dentistry is increasing every year, while possibilities for using AI methods within everyday endodontic practice is still quite confined and not always enough affirmed. Objective. To systematize and depict principal data regarding use of virtual artificial intelligence for various endodontic-related clinical purposes. Materials and Methods. Targeted literature search was provided within National Center for Biotechnology Information databases using pre-specified Mesh-terms algorithm. The following information was extracted from each publication during content analysis: diagnostic and treatment planning aspects of endodontic practice for which AI methods could be applied; accuracy levels registered for AI models used for different endodontic-related purposes; limitations of using AI within endodontic practice. Results. AI features could be used in endodontic practice for the following reasons: analysis of root canal morphology, identification of root fractures, verification of periapical lesions, estimation of root canal working length, root canal treatment planning, prediction of pain development during post-treatment period, predication of endodontic interventions success. The most prevalently used artificial intelligence methods for different endodontic diagnostic and treatment planning objectives were the following: convolutional neural network, artificial neurons network, case-based reasoning, deep learning, machine learning, neuro-fuzzy inference system, probabilistic neural network. Conclusion. Main advantage of using AI models in endodontic practice associated with improvement of diagnostic accuracy within reduced amount of time needed for X-ray images and clinical data analysis. AI application for apical foramen detection and working length determination demonstrates the highest level of accuracy compared to AI performance for other clinically related objectives in endodontics.


  • Open Access

    Study of The Adhesion Strength of Photocomposite Enamel Sealants to the Tooth Surface

    by I. V. Noenko, O. V. Pavlenko, Yu. O. Mochalov

    The purpose of the study was to compare an adhesion strength of some modern enamel sealants to the enamel of a developing tooth which occurs without adhesive preparation of tooth surface. Materials and methods. In laboratory the shear adhesion strength to human teeth enamel without adhesive system application was compared for “Fissurit FX” (VOCO), “Clinpro™ Sealant” (3M™ ESPE™) and “Jen-Fissufil” (Jendental-Ukraine LLC). 30 samples were tested on tensometric system. Tests were performed according to requirements of ISO 4049:2019 “Dentistry – Polymer-based restorative materials” and ISO 6874:2005 “Dentistry – Polymer-based pit and fissure sealants”. Results and discussion. Performed experimental studies of sealant adhesion (without the use of adhesive systems, only with acid etching) showed that it was the largest in the domestic “Jen-Fissufil” – 9.80 ± 1.17 MPa (M=10.42 MPa, min – 7.41 MPa, max – 11.07 MPa); less in “Fissurit FX” – 9.78 ± 1.33 MPa (M=9.43 MPa, min – 8.23 MPa, max – 12.62 MPa) and “Clinpro™ Sealant” – 9.55 ± 1.88 MPa (М=8.69 MPa, min – 6.35 MPa, and max – 14.73 MPa). The performed statistical tests did not reveal any significant differences between the adhesion strength in all three subgroups. Due to the changes in the concept of dental caries development and approaches to its control that have taken place in dentistry over the past 30 years, the role of enamel sealants in achieving caries control in individual and communal prevention of dental diseases has significantly increased. The tendency to expand the indications for the use of photocomposite enamel sealants in clinical practice is also worth noting. In addition to their direct purpose, the materials can be used for “repair” and restoration of individual photocomposite fillings with minor wear and used as a lining material for the restoration of teeth with carious cavities with a high C-factor. Conclusion. In modern dentistry the use of enamel photocomposite sealants is one of the most effective and reliable methods of preventing caries of the occlusal surfaces of teeth. The study of shear adhesion to acid-etched enamel for photocomposite materials “Fissurit FX”, “Clinpro™ Sealant” and “Jen-Fissufil” did not reveal any significant differences. The technology of composite tooth enamel sealants is currently successful in clinical practice and continues to improve and develop. The development of new and quality improvement of such materials is an urgent issue for science and technology

  • Open Access

    COMPARATIVE STUDY OF POLYMERIZATION DEPTH OF THREE PHOTOCOMPOSITE DENTAL FILLING MATERIALS FOR BULK FILL RESTORATION

    by Igor Noenko, Oleksiy Pavlenko, Iurii Mochalov

    The objectives of the study was to compare the depth of polymerization of flowable photocomposite dental restorative materials for bulk fill tooth restorations in laboratory. Materials and methods. Three flowable bulk fill photocomposite dental restorative materials – "SDR® Posterior Bulk Fill Flowable Base," "Filtek™ Bulk Fill Flowable" and domestic "Jen-Radiance Molar-FW" – were chosen for the study. For each material, 10 black opaque thin-walled polyvinyl chloride molds with a length of 10.00 mm and a diameter of 3.00 mm were prepared. The molds were air-dried from a compressor and fixed in fluoroplastic retainers perpendicular to the metal opaque surface below and subsequently filled with the investigated restorative material along the entire length, in a contact manner, along the wall. After filling, the material was polymerized with an LED photopolymerizer directly in contact with the surface of the light guide for 40 seconds. Subsequently, the material was removed from the forms and the remains of the unpolymerized mass were removed from the surface of the polymerized cylinder of the composite with a metal dental sickle-shaped carrier (scarification test). The length of the polymerized cylinder was measured using an electronic micrometer. Results. Therefore, the study of the depth of polymerization of flowable bulk fill photocomposites "SDR® Posterior Bulk Fill Flowable Base", "Filtek™ Bulk Fill Flowable" and domestic "Jen-Radiance Molar-FW" showed that signs of polymerization of all three materials were observed in a depth of more than the "declared" four millimeters which may be explained by the improvement of the recipe for the preparation of such materials and the optimization of the transparency of the organic component and inorganic filler, as well as the regular distribution of photoactivators in the mass. "SDR" polymerized to a depth of 7.38 ± 0.17 (M = 7.30) mm, the minimum value was 7.16 mm and the maximum value was 7.71 mm. "Filtek Bulk Fill Flowable" polymerized to a lesser depth – on 6.34 ± 0.14 (М = 6.38) mm, the minimum value was 6.05 mm and the maximum value was 6.55 mm. The domestic analogue "Jen-Radiance Molar‑FW" showed even higher values of polymerization depth – 8.03 ± 0.19 (М = 7.98) mm, the minimum value was equal to 7.75 mm and the maximum value was 8.41 mm. Statistical tests showed probable similarity between "SDR" and "Jen-Radiance Molar-FW" in the depth of polymerization. Conclusions. All three studied flowable bulk fill photocomposite materials were polymerized to a depth greater than 4.00 mm. Domestic "Jen-Radiance Molar-FW" was similar to "SDR" according to the investigated feature.


  • Open Access

    Clinical aspects of tooth autotransplantation and post-endodontic restoration of autrotransplanted tooth: case-based literature review

    by Igor Noenko, Kostyantyn Kostura, Olexander Khodakov

    Introduction. Tooth autotransplantation allows to maintain a vital status of periodontal ligament, which supports the preservation of the alveolar bone volume, better conservation of the interdental papilla and the possibility of dental movement through orthodontic forces. It has been shown that longevity and prognosis of autotransplanted teeth are comparable with those of dental implants. Objective. To discuss major practically-oriented aspects regarding tooth autotransplantation operation including further post-endodontic restoration based on presented clinical case. Materials and Methods. A bibliographic search was conducted in April 2022 by the using MESH terms equivalent to the keywords “tooth” and “autotransplantation” within the Cochrane Library and PubMed database with the aim to identify publications related with practical aspects of tooth autotransplantation presented in clinical case. Data extraction during content-analysis of selected publications was provided selectively in terms to represent the most practically valuable information regarding tooth autotransplantation operation, principles of tooth autotransplantation surgery and further post-endodontic restoration of autotransplanted tooth taking into account aspects highlighted in present clinical case. Results. Due to the provided literature review it was highlighted that success rate of tooth autotransplantation is highly inţuenced by such factors as the stage of root development, morphology of the tooth, selected surgical procedure, time of extraoral exposure of donor tooth, shape of the recipient socket, vascularity of the recipient site, and the vitality of the periodontal ligament cells, impact of which was considered during presented clinical case. Conclusions. Present clinical case report with accompanied literature review arguments the clinical perspective of tooth autotransplantation procedure as valuable treatment option, and highlights major practically-oriented aspects regarding tooth autotransplantation operation including further post-endodontic restoration of donor tooth. Synergy of tooth autotransplantation and post-endodontic restoration protocols in the hands of an experienced doctor who is ready to carefully follow the scientiŢc evidence-based protocol associated with successful outcome of provided treatment.