OPOleksii Volodymyrovych Pavlenko

Oleksii Volodymyrovych Pavlenko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oleksii Volodymyrovych Pavlenko has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of current dental implant patents: a review of international and ukrainian technical solutions

    by Mykhailo Vasylovych Kasianchuk, Oleksandr Borysovych Belikov, Vugar Ismet Ogli Aliyev, Maksym Oleksiyovych Pavlenko, Oleksii Volodymyrovych Pavlenko

    Background. Dental implants are among the main methods for restoring the function of the dentoalveolar system. However, conventional designs do not always fully account for individual anatomical features, bone density, mucosal condition, and the need for even load distribution, which may reduce primary stability, impair osseointegration, and increase the risk of long-term complications. Purpose – to analyze current patents on dental implants and identify structural solutions aimed at improving osseointegration, fixation, biocompatibility, and long-term clinical effectiveness. Materials and Methods. A patent search was conducted in the Google Patents, Espacenet, and WIPO Patentscope databases using keywords, Boolean operators, a 2019–2024-time filter, and patent classification A61C 8/00. Study selection followed a modified PRISMA framework with stepwise exclusion of duplicates, irrelevant descriptions, and technical solutions not directly related to implant design. Results. A total of 1,819 patents were selected and analyzed according to the predefined criteria. Conical, parallel, and hybrid intraosseous implant designs predominated, providing higher primary stability and better adaptation to different bone types. Self-tapping and hybrid thread designs proved the most promising because they create compressive loading, reduce tissue trauma, and improve bone contact. Textured, multilayered, antibacterial, hydroxyapatite, and calcium phosphate coatings were also found to be effective, together with novel solutions related to cold welding, anti-rotational mechanisms, modular elements, internal channels, and damping structures. One-stage implants with a conical stepped neck may also promote faster healing. Conclusions. Current patented solutions in dental implantology are aimed at improving osseointegration, functionality, durability, and clinical reliability of implants.

  • Open Access

    DEVELOPMENTAL PATTERNS OF DENTISTRY IN UKRAINE DURING WAR

    by Maya Yermolayeva, Oleksandr Udod, Olga Chernyshova, Tetiana Volosovets, Oleksii Pavlenko, Olena Doroshenko, Maxim Doroshenko, Inna Dikova

    Introduction. Martial law, the deterioration of the health of the Ukrainian population against the backdrop of four years of Russian aggression, and the consequences of the COVID-19 pandemic necessitate changes to the structure, forms, and scope of undergraduate, postgraduate dental education and continuous professional development of dentists to ensure qualified dental care for the population. Objective. To evaluate the current system of undergraduate, postgraduate dental education and continuing professional development of dentists in Ukraine and its relevance to current challenges, to identify measures for necessary changes. Materials and methods of research. An assessment of the existing regulatory framework and practical principles of undergraduate, postgraduate dental education and continuing professional development of dentists in Ukraine and the EU was carried out. Methods of a systematic approach and comparison were used. Results and discussion. The rapid development of digitalization in dental education and the introduction of interdisciplinary education, the latest information, simulation, and distance learning technologies, the use of artificial intelligence, and augmented reality techniques into the educational process must also be reflected in the new paradigm of continuing dental education in Ukraine in the current difficult circumstances. Undergraduate training for dentists will be provided in 2025 in Ukraine at 25 higher education institutions, including 14 higher education institutions of the Ministry of Health of Ukraine, 3 higher education institutions of the Ministry of Education and Science of Ukraine, and 8 privately owned institutions. It lasts 5 years, which generally corresponds to the standards of dental education in the EU. According to the Unified State Electronic Database on Education, as of October 2025, only 7,491 people are studying dentistry (in 2020 – 12,759), of which 595 (in 2020 – 502) are state-funded, mainly in higher education institutions of the Ministry of Health of Ukraine. The main characteristics of competency-based continuing dental education should be: modern content of educational programs developed in accordance with the needs of industry and society; student-centeredness; problem-oriented approach; rational use of teaching time with an emphasis on practice. Conclusions. Understanding the importance of dentists' competencies for the healthcare industry, the importance of their continuing education based on competence and proper medical practice, its integration with EU requirements, increasing the duration of internships, and introducing residencies will help improve the quality of dental education during wartime.

  • Paradigm of conjunctive use of oral implantation and dental implants for eliminating the clinical manifestations of edentulous aging

    by M.V. Kasianchuk, O.B. Belikov, M.A. Rusnak, P.M. Fochuk, O.V. Pavlenko

    Background. The problem of edentulism remains highly relevant in modern dentistry, requiring effective and safe methods for restoring the dentition. Traditional approaches to dental implantation often present certain limitations, necessitating the search for innovative solutions. In this context, research medical navigation devices on the Android platform combined with a standardized dental unit, demonstrates consi- derable promise, especially for improving the ergonomics of implantologists’ work. Purpose – to increase the effectiveness of oral implantation through the onjunctive combination of digital navigation and a proprietary implantation system using the «Navigator YK» device. Materials and Methods. A prospective clinical study was performed on 120 patients aged 42–68 years. The control group (30 patients) underwent the classical Brånemark method, and the experimental group (90 patients) was treated using the authors’ conjunctive method with the «Navigator YK» device. Effectiveness was evaluated by clinical, radiological, and ergonomic indicators. Statistical analysis was performed in R v4.4 using Pearson’s c2, Kruskal–Wallis, and Mann–Whitney tests (p < 0.05). Results. The study revealed significant advantages of the developed technique compared to the control group. Stable osseointegration was observed in 88 (97.8%) patients in the experimental group and 20 (66.7%) of the control group (c2 = 24.20; p = 8.6×10–7). The duration of implantation was reduced from 37.2 ± 3.1 to 28.4 ± 2.6 min (p < 0.01), and positioning accuracy improved more than twofold (from 3.2 ± 0.6 to 1.1 ± 0.3). The frequency of postoperative complications de- creased 6-fold. Conclusions. The authors’ conjunctive implantation method using the «Navigator YK» navigation system provides a significantly higher success rate, minimal bone resorption, and improved surgical ergonomics. The findings confirm the feasibility of integrating digital navigation into standard dental implantology protocols. The method demonst- rates promising potential for widespread clinical application and requires further multicenter studies to validate its effectiveness and optimize practical implementation.

  • Open Access

    LITERATURE REVIEW ON THE USE OF FRONTAL DEPROGRAMMERS OF THE MASTICATORY MUSCLES IN THE TREATMENT OF TEMPOROMANDIBULAR DISORDERS AND METHODS FOR THEIR IMPROVEMENT

    by O. V. Pavlenko, V. V. Pehnyo, G. Osnach

    The Aim of this study is to analyze modern sources of literature on the use of deprogramming devices, their design and to propose a simpler way to make it.Materials and methods. In this article we describe the results of a literature review sources on the use of deprogramming devices. Based on the analysis of literature sources, the common properties of all deprogramming devices were revealed, their shortcomings were identified, and their comparison was carried out.Results. It has been established that deprogramming device work on the basis of the “closing axis of the lower jaw”, which is a line from the center of the condyle to the cutting edge of the lower incisor.Occlusive and deprogramming devices, particular anterior median splints, effectively reduce muscle tension by influencing proprioceptive sensitivity and neuromuscular coordination of the dentoalveolar system, which contributes to both the diagnosis and treatment of temporomandibular disorders (TMD). The use of deprogramming devices ensures accurate recording of jaw ratios and promotes muscle relaxation, using packaging composite materials eliminates the need for laboratory steps, optimizing the rehabilitation process and accelerating clinical results. The author's proposal for a frontal deprogrammer can be as a method of choice to optimize and accelerate the results of the rehabilitation process for a patient with TMD by eliminating the need for laboratory steps. У статті представлені результати огляду джерел літератури щодо використання депрограмуючих пристроїв. Встановлено, що депрограмуючі пристрої працюють на основі «замикаючої вісі нижньої щелепи», що є уявною лінією від центру суглобової голівки до ріжучого краю нижнього різня. Оклюзійні та депрограмуючі пристрої, зокрема передні серединні шини, ефективно знижують м’язову напругу через вплив на пропріоцептивну чутливість та нейром’язову координацію зубощелепної системи, що сприяє як діагностиці, так і лікуванню розладів скронево-нижньощелепних суглобів (СНЩС). Використання депрограмуючих пристроїв забезпечує точну реєстрацію щелепних співвідношень і сприяє м’язовій релаксації, а застосування пакувальних композитних матеріалів усуває необхідність лабораторних етапів, оптимізуючи реабілітаційний процес та прискорюючи клінічні результати.

  • Open Access

    COMPARATIVE STUDY OF FLEXURAL STRENGTH OF PHOTOCOMPOSITE DENTAL ENAMEL SEALANTS

    by I.V. Noenko, O.V. Pavlenko, I.O. Mochalov

    Background. Dental caries is a widespread worldwide disease of multifactorial genesis. The leading mechanism of its development is a long-term imbalance of the physiological balance between the inorganic component of the teeth hard tissues and the liquid biofilm formed on their surface, the predominance of the demineralization processes in hard tissues over the processes of remineralization. The use of dental enamel sealants has proven to be effective in preventing and reducing the intensity of dental caries. Modern bioactive polymer sealants for enamel contain such remineralizing agents as sodium fluoride, nanoamorphous calcium phosphate, beta-tricalcium phosphate, and particles of bioactive glass. For all dental composite filling materials, mechanical stability is one of the prerequisites for the long-term clinical success of restorations and fillings, and accordingly, temporary protective structures made of sealants. Aim: to compare the flexural strength and modulus of elasticity of three modern photocomposite enamel sealants. Materials and methods. In laboratory conditions for three modern photocomposite dental materials for sealing fissures and pits of enamel "Fissurit FX" (VOCO), "Clinpro™ Sealant" (3M™ ESPE™) and "Jen-Fissufil" (Jendental-Ukraine LLC) a flexural strength (three-point test) and elastic modulus were determined in accordance with the requirements of the international standard ISO 4049:2019. 6 samples of each material, polymerized and kept for a day in humid conditions, were examined. Results. The highest elastic modulus and flexural strength were in "Fissurit FX" – 5.17±0.80 GPa (M=5.00 GPa) and 130.07±7.75 MPa (M=127.81 MPa), respectively. In "Clinpro™ Sealant" the elastic modulus was 2.97±0.12 GPa (М=3.00 GPa), the flexural strength was 100.01±14.33 (М=96.73) MPa. In "Jen-Fissufil" the elastic modulus was 3.47±0.52 GPa (M=3.17 GPa), the flexural strength was 90.91±6.66 MPa (M=93.02 MPa). The studied indicators of all three materials exceeded the requirements of the international standard ISO 4049:2019. Conclusion. The performed studies showed high mechanical properties of all three dental sealants for enamel and that they have the potential to withstand long-term periodic masticatory load when functioning on the surface of teeth. Актуальність. Карієс зубів – це широко розповсюджене у всьому світі захворювання мультифакторіального генезу. Провідний механізм розвитку тривалий у часі дисбаланс фізіологічної рівноваги між неорганічним компонентом твердих тканин зубів і рідиною біоплівки, що формується на їх поверхні, переважання процесів демінералізації твердих тканин над процесами ремінералізації. Застосування стоматологічних емалевих герметиків показало себе ефективним в плані запобігання та зменшення інтенсивності карієсу зубів. Сучасні біоактивні полімерні герметики для емалі містять у своєму складі такі ремінералізуючі агенти, як фторид натрію, наноаморфний фосфат кальцію, бета-трикальцій фосфат, часточки біоактивного скла. Для всіх стоматологічних композитних пломбувальних матеріалів механічна стабільність є однією з передумов довгострокового клінічного успіху реставрацій та пломб, і відповідно й тимчасових захисних структур, що виготовляються з герметиків. Ціль: порівняти міцність на згинання та модуль еластичності у трьох сучасних фотокомпозитних емалевих герметиків. Матеріали та методи. Для трьох сучасних фотокомпозитних стоматологічних матеріалів для герметизації фісур та ямок емалі «Fissurit FX» (VOCO) , «Clinpro™Sealant» (3M™ ESPE™) та «Jen-Fissufil» (ТОВ «Джендентал-Україна»), – в лабораторних умовах було виконано визначення міцності на згинання (трьох-точковий тест) та модулю пружності за Юнгом відповідно до вимог міжнародного стандарту ISO 4049:2019. Було досліджено по 6 зразків кожного матеріалу, заполімеризованих та витриманих протягом доби у вологих умовах. Результати. Найвищими модуль пружності Юнга та міцність на згинання були у «Fissurit FX» – 5,17±0,80 ГПа (М=5,00 ГПа) та 130,07±7,75 МПа (М=127,81 МПа) відповідно. У «Clinpro™Sealant» модуль пружності за Юнгом становив 2,97±0,12 ГПа (М=3,00 ГПа), міцність на згинання – 100,01±14,33 (М=96,73) МПа. У «Jen-Fissufil» модуль пружності Юнга становив 3,47±0,52 ГПа (М=3,17 ГПа), міцність на згинання – 90,91±6,66 МПа (М=93,02 МПа). Досліджені показники у всіх трьох матеріалів перевищували вимоги міжнародного...

  • Open Access

    Study of The Adhesion Strength of Photocomposite Enamel Sealants to the Tooth Surface

    by I. V. Noenko, O. V. Pavlenko, Yu. O. Mochalov

    The purpose of the study was to compare an adhesion strength of some modern enamel sealants to the enamel of a developing tooth which occurs without adhesive preparation of tooth surface. Materials and methods. In laboratory the shear adhesion strength to human teeth enamel without adhesive system application was compared for “Fissurit FX” (VOCO), “Clinpro™ Sealant” (3M™ ESPE™) and “Jen-Fissufil” (Jendental-Ukraine LLC). 30 samples were tested on tensometric system. Tests were performed according to requirements of ISO 4049:2019 “Dentistry – Polymer-based restorative materials” and ISO 6874:2005 “Dentistry – Polymer-based pit and fissure sealants”. Results and discussion. Performed experimental studies of sealant adhesion (without the use of adhesive systems, only with acid etching) showed that it was the largest in the domestic “Jen-Fissufil” – 9.80 ± 1.17 MPa (M=10.42 MPa, min – 7.41 MPa, max – 11.07 MPa); less in “Fissurit FX” – 9.78 ± 1.33 MPa (M=9.43 MPa, min – 8.23 MPa, max – 12.62 MPa) and “Clinpro™ Sealant” – 9.55 ± 1.88 MPa (М=8.69 MPa, min – 6.35 MPa, and max – 14.73 MPa). The performed statistical tests did not reveal any significant differences between the adhesion strength in all three subgroups. Due to the changes in the concept of dental caries development and approaches to its control that have taken place in dentistry over the past 30 years, the role of enamel sealants in achieving caries control in individual and communal prevention of dental diseases has significantly increased. The tendency to expand the indications for the use of photocomposite enamel sealants in clinical practice is also worth noting. In addition to their direct purpose, the materials can be used for “repair” and restoration of individual photocomposite fillings with minor wear and used as a lining material for the restoration of teeth with carious cavities with a high C-factor. Conclusion. In modern dentistry the use of enamel photocomposite sealants is one of the most effective and reliable methods of preventing caries of the occlusal surfaces of teeth. The study of shear adhesion to acid-etched enamel for photocomposite materials “Fissurit FX”, “Clinpro™ Sealant” and “Jen-Fissufil” did not reveal any significant differences. The technology of composite tooth enamel sealants is currently successful in clinical practice and continues to improve and develop. The development of new and quality improvement of such materials is an urgent issue for science and technology

  • Open Access

    ANALYSIS OF PERIODONTAL TISSUE STATUS OVER TIME DURING THE LOCAL TREATMENT OF PATIENTS WITH GENERALIZED PERIODONTITIS

    by Olena Sluchevska, Oleksiy Pavlenko, Iurii Mochalov, Nazariy Heley

    The objectives of the study was to evaluate the changes in the special indicators of periodontal tissue damage during the local treatment among patients with generalized periodontitis. Materials and methods. At private medical institution specialized in periodontal treatment, 30 patients (15 men and 15 women, aged 40.23 ± 8.76 years (M = 39.00)) with generalized periodontitis were treated according to the standard treatment protocol. Protocol included ultrasonic removal of tartar and other dental sediments, segmental subgingival scaling, air-abrasive polishing and giving recommendations on hygienic care of the oral cavity. All patients obtained the control of the maximum depth of periodontal pockets, the level of the indices of PMA, CPITN and Green–Vermilion (OHI-S) on at the start of treatment, after 6 months and one year later during follow-up. Results. Periodical observation and clinical examination showed a partial restoration of the marginal periodontium (gingival) attachment among patients – that was observed by periodontal pocket depth decrease from 9.60 ± 2.07 (M = 10.00) mm to 7.23 ± 1.40 (M = 7.00) mm after 6 months, and to 4.98 ± 0, 88 (M = 5.00) mm a year after the start of treatment. The reduction of the indicator was 4.63 ± 1.43 (M = 4.50) mm. Amnog males recovery took place more intensively which was statistically significant. Initially, PMA index level was 66.38 ± 13.71 (M = 67.50)%, six months later – 32.63 ± 7.48 (M = 32.50)%. A year later – 28.90 ± 8.10 (M = 28.00)%. The reduction of the PMA index was 37.48 ± 9.05 (M = 37.00)%. At the end of the observation period, the reduction in the level of periodontal tissue inflammation among males was 1.2 times more intense than among females which was statistically significant to. At the beginning of observation, the CPITN index was 5.21 ± 0.95 (M = 5.00) with a range of 3.30 to 6.90. After six months – 2.63 ± 0.69 (M = 2.40), after a year – 2.63 ± 0.71 (M = 2.55). Reduction of the CPITN index was 2.59 ± 0.48 (M = 2.50), no gender difference was found. At the beginning of the observation, the OHI-S level was 4.40 ± 0.54 (M = 4.45) and the range was from 3.00 to 5.60. Six months later – 1.80 ± 0.40 (M = 1.80), one year later – 1.79 ± 0.41 (M = 1.80). The index reduction was 2.62 ± 0.48 (M = 2.45), no differences were found among patients of different sexes. Conclusions. The obtained data indicate uneven effectiveness of local treatment of generalized periodontitis, which includes influence on local factors of disease development. The results suggest a faster recovery of the attachment of the marginal periodontium and a decrease in the intensity of inflammation among male patients and the probable presence of higher physiological reserves of periodontal tissue repair.


  • Open Access

    COMPARATIVE STUDY OF POLYMERIZATION DEPTH OF THREE PHOTOCOMPOSITE DENTAL FILLING MATERIALS FOR BULK FILL RESTORATION

    by Igor Noenko, Oleksiy Pavlenko, Iurii Mochalov

    The objectives of the study was to compare the depth of polymerization of flowable photocomposite dental restorative materials for bulk fill tooth restorations in laboratory. Materials and methods. Three flowable bulk fill photocomposite dental restorative materials – "SDR® Posterior Bulk Fill Flowable Base," "Filtek™ Bulk Fill Flowable" and domestic "Jen-Radiance Molar-FW" – were chosen for the study. For each material, 10 black opaque thin-walled polyvinyl chloride molds with a length of 10.00 mm and a diameter of 3.00 mm were prepared. The molds were air-dried from a compressor and fixed in fluoroplastic retainers perpendicular to the metal opaque surface below and subsequently filled with the investigated restorative material along the entire length, in a contact manner, along the wall. After filling, the material was polymerized with an LED photopolymerizer directly in contact with the surface of the light guide for 40 seconds. Subsequently, the material was removed from the forms and the remains of the unpolymerized mass were removed from the surface of the polymerized cylinder of the composite with a metal dental sickle-shaped carrier (scarification test). The length of the polymerized cylinder was measured using an electronic micrometer. Results. Therefore, the study of the depth of polymerization of flowable bulk fill photocomposites "SDR® Posterior Bulk Fill Flowable Base", "Filtek™ Bulk Fill Flowable" and domestic "Jen-Radiance Molar-FW" showed that signs of polymerization of all three materials were observed in a depth of more than the "declared" four millimeters which may be explained by the improvement of the recipe for the preparation of such materials and the optimization of the transparency of the organic component and inorganic filler, as well as the regular distribution of photoactivators in the mass. "SDR" polymerized to a depth of 7.38 ± 0.17 (M = 7.30) mm, the minimum value was 7.16 mm and the maximum value was 7.71 mm. "Filtek Bulk Fill Flowable" polymerized to a lesser depth – on 6.34 ± 0.14 (М = 6.38) mm, the minimum value was 6.05 mm and the maximum value was 6.55 mm. The domestic analogue "Jen-Radiance Molar‑FW" showed even higher values of polymerization depth – 8.03 ± 0.19 (М = 7.98) mm, the minimum value was equal to 7.75 mm and the maximum value was 8.41 mm. Statistical tests showed probable similarity between "SDR" and "Jen-Radiance Molar-FW" in the depth of polymerization. Conclusions. All three studied flowable bulk fill photocomposite materials were polymerized to a depth greater than 4.00 mm. Domestic "Jen-Radiance Molar-FW" was similar to "SDR" according to the investigated feature.