IOIkechukwu Emmanuel Onwunta

Ikechukwu Emmanuel Onwunta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ikechukwu Emmanuel Onwunta has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MRCP Findings Suggestive of Mirizzi Syndrome with Concomitant Choledocholithiasis: A Case Report

    by Oluwaseun Olaoluwa Oyelayo, Adewale Wasiu Akeem, Hakeem Kayode Alade, Ikechukwu Emmanuel Onwunta

    Background: Mirizzi syndrome may coexist with distal choledocholithiasis, which can independently contribute to biliary obstruction. Case presentation: A 45-year-old woman presented with recurrent right upper quadrant pain, jaundice and pruritus. MRI and MRCP showed intrahepatic biliary dilatation, marked distension of the gallbladder and cystic duct, and a suspected communication between the dilated cystic duct and common bile duct. A 2.3-cm calculus in the distal common bile duct produced a filling defect with upstream dilatation. The patient was referred for further management. Surgical, endoscopic and follow-up findings were unavailable. Conclusion: MRCP delineated the biliary anatomy and suggested Mirizzi syndrome with a possible biliary fistula and concomitant distal choledocholithiasis. The fistula and the Csendes subtype remain unconfirmed.

  • Open Access

    Ultrasonographic normative reference values for median nerve cross-sectional area in healthy Nigerian women of reproductive age

    by O. O. Oyelayo, V. O. Oyedepo, A. A. Olalere, H. K. Alade, E. O. Owojuyigbe, E. F. Oduoma, I. E. Onwunta, A. S. Aderibigbe, O. O. Ayoola

    Background: Ultrasonographic measurement of median nerve cross-sectional area (CSA) is widely used in evaluating carpal tunnel syndrome (CTS). Accurate interpretation requires population-specific normative values, which remain limited for African populations, particularly women. This study established normative reference values for median nerve CSA in healthy Nigerian women of reproductive age and evaluated associations with anthropometric variables. Methods: This prospective cross-sectional study included 165 healthy, asymptomatic, non-pregnant women aged 18–49 years. Bilateral median nerve CSA was measured using a 6–12 MHz linear transducer at the carpal tunnel inlet (pisiform level) and 5 cm proximal to the distal wrist crease. All ultrasound examinations were performed by a single experienced radiologist. Measurements were calculated using the ellipsoid formula, with three readings obtained at each site and the mean value recorded for analysis. Paired t-tests assessed side-to-side differences, and Pearson correlation evaluated associations with age and body mass index (BMI). Statistical significance was set at p < 0.05. Results: Mean age was 32.08 ± 6.73 years; mean BMI was 25.52 ± 5.30 kg/m 2 (47.9% normal, 30.9% overweight, 19.4% obese). At the carpal tunnel inlet, mean CSA was 8.17 ± 2.65 mm 2 on the right (95th percentile: 13.73 mm 2 ) and 7.84 ± 2.34 mm 2 on the left (95th percentile: 12.36 mm 2 ). Proximally, mean CSA was 6.56 ± 1.90 mm 2 on the right (95th percentile: 9.50 mm 2 ) and 6.42 ± 2.14 mm 2 on the left (95th percentile: 9.98 mm 2 ). Side-to-side differences were not significant ( p = 0.053 at carpal tunnel inlet; p = 0.176 proximally). Weak negative correlations were observed between CSA and age and BMI (all p > 0.05). Conclusion: This study provides normative reference values for median nerve CSA in Nigerian women. The reported 95th percentile values may serve as provisional upper reference limits; however, further clinical and electrodiagnostic validation is required to establish definitive diagnostic cut-offs for CTS.

  • Open Access

    Radiographers’ Perceptions of Artificial Intelligence and Theranostics

    by Sobechukwu Onwuzu, Adanna Uche-Nwankwo, Chinemerem Ozoamalu, Chikaosolu Ozohili, Ezinne Peter-Adim, Prisca Solomon, Precious Sopuluchukwu, Ikechuwku Onwunta

    Background: Artificial Intelligence (AI) and theranostics are transforming radiographic practice by enhancing diagnostic precision and enabling personalized treatment. However, these innovations raise concerns about professional adaptation and job security. Objectives: To investigate Nigerian radiographers’ awareness, perceptions, and adaptability regarding these technologies, with a focus on job security and professional relevance. Method: A cross-sectional survey of 349 Nigerian radiographers assessed awareness, perceptions, and adaptability regarding AI and theranostics. Data were analyzed using descriptive statistics (SPSS v25). Results: Awareness was higher for AI than theranostics: 31.2% were moderately familiar and 28.7% very familiar with AI, whereas 34.4% were not familiar with theranostics. Most respondents (64.5%) had not attended training or seminars. Regarding possible role displacement through automation, 107 respondents (30.7%) agreed and 35 (10.0%) strongly agreed. Further education or certification attracted agreement from 179 respondents (51.3%) and strong agreement from 79 (22.6%). Adoption as an opportunity for career growth attracted agreement from 168 respondents (48.1%) and strong agreement from 93 (26.6%). Key adaptation factors included mentorship (50.7% in the agree category), financial support (45.6% in the agree category), and curriculum integration (41.5% in the agree category). Conclusion: Nigerian radiographers demonstrate moderate familiarity with AI but limited understanding of theranostics. While job security concerns persist, willingness to upskill is strong. Structured training, mentorship, and curriculum reform are essential to support professional adaptation and safeguard radiographers’ relevance in the era of AI and theranostics. Contribution: This study highlights the need for radiography professional bodies and policymakers to prioritize structured training pathways, financial incentives, and cross-disciplinary collaborations to ensure radiographers remain central to technological transitions.


  • Open Access

    Normative values of optic nerve sheath diameter in Southwestern Nigeria using magnetic resonance imaging

    by Ikechukwu Emmanuel Onwunta, Aminu Muzammil, Ikenna Caleb Onyemauwa, Stephen Chukwuebuka Ugwuobu, Abdullahi Alfa, Benjamin Ikemefuna Ude, Ignatius Ajogu Nwigboji, Ifeanyi Daniel Obatu, Ebube Lilian Agbo

    Background: Normative values of optic nerve sheath diameter (ONSD) are essential for establishing baseline measurements to differentiate normal from pathological states. This underscores the importance of generating population-specific normative values. Thus, this study aimed to determine the normative values of ONSD using magnetic resonance imaging (MRI) in normal adults from Southwestern Nigeria. Methods: This retrospective study assessed brain MRI images reported to be normal from a Multisystem Hospital in Southwestern Nigeria, acquired between October 2024 and January 2025. A total of 163 patients, aged 15–90 years, were included. ONSDs were measured at 3 mm and 8 mm posterior to the globe for both eyes using electronic calipers on the picture archiving and communication system (PACS) workstation of the hospital. Measurements were taken by a single investigator. Statistical analysis was performed using SPSS version 23. Results: The study included 90 females (55.2%) and 73 males (44.8%) with an average age of 45.63 ± 19.38 years. The mean ONSDs for the right eye at 3 mm and 8 mm from the globe were 5.05 ± 0.63 mm and 4.37 ± 0.51 mm, respectively. For the left eye, mean ONSDs were 5.06 ± 0.63 mm and 4.37 ± 0.50 mm. A very weak and statistically insignificant correlation was noted between ONSD measured at 3 mm and 8 mm and both gender and different age groups (p > 0.05). No significant differences were observed between the right and left eyes’ ONSDs. However, a significant difference was observed in the ONSD measurements at 3 mm and 8 mm from the posterior globe margin for both eyes. The intra-class correlation coefficients (ICCs) for all measurements indicated excellent reliability, with values greater than 0.9. Conclusion: This study established normative ONSD values for the Southwestern Nigerian population using MRI. These normative values are crucial for clinical practice and can aid in the early detection and monitoring of conditions related to elevated intracranial pressure.

  • Open Access

    Evans Index in a Normal Nigerian Population Using Magnetic Resonance Imaging: A Single-Center Study

    by Stephen Chukwuebuka Ugwuobu, Oluwaseun Olaoluwa Oyelayo, Ikechukwu Emmanuel Onwunta, Ignatius Ajogu Nwigboji, Hakeem Kayode Alade, Aminu Muzammil, Ikenna Caleb Onyemauwa, Benjamin Ikemefuna Ude, Mustapha Nma Isah, Ernest Atuoha

    Ugwuobu SC, et al. Investig Magn Reson Imaging. 2025 Dec;29(4):195-200. https://doi.org/10.13104/imri.2025.0034

  • Open Access

    Recurrent cholera outbreaks in Nigeria: A review of the underlying factors and redress

    by Ikechukwu Emmanuel Onwunta, Gerald Obinna Ozota, Chizaram Adaeze Eze, Izuchukwu Favour Obilom, Onyeka Chinenye Okoli, Cynthia Nneka Azih, Christabel Ogechukwu Okoye, Ebube Lilian Agbo


  • Normative values of the alpha angle and triangular index measured from the hip radiographs of an African population

    by Sobechukwu W I Onwuzu, Julius A Agbo, Ifunanya S Onwuzu, Ikechukwu E Onwunta, Caleb I Onyemauwa, Osagiede Osasuyi, Remigius Emmanuel