Sobechukwu Warric Iwene Onwuzu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sobechukwu Warric Iwene Onwuzu has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Ifunanya Sylvia Elo
Department of Medical Radiography and Radiological Sciences, University of Nigeria, Enugu, Nigeria
4 shared publications Charles U Eze
2 shared publications- Everistus Obinna Abonyi
Department of Medical Radiography and Radiological Sciences, Faculty of Health Sciences & Technology, College of Medicine, University of Nigeria, Enugu Campus, Nigeria
2 shared publications - Ikechukwu Emmanuel Onwunta
University of Nigeria
2 shared publications - Julius Amechi Agbo
Department of Medical Radiography and Radiological Sciences, Faculty of Health Sciences and Technology, College of Medicine, University of Nigeria, Enugu, Nigeria
2 shared publications Kingsley Asogwa
Department of Medical Radiography and Radiological Sciences, University of Nigeria Enugu Campus, Enugu State, Nigeria
2 shared publications
Latest Publications
- 19 May 2026
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 42  (6) , 477-484
Sonographic Diagnosis of Uterine Fibroids and the Associated Patient Experience: The Psychosocial and Cultural Challenges Encountered
Objective: To explore the psychological impact, coping strategies, and healthcare experiences of African women undergoing a sonographic diagnosis of uterine fibroids, guided by the Lazarus Stress and Coping Theory and the Engel Biopsychosocial Model. Materials and Methods: Semi-structured interviews were conducted with 20 Nigerian women aged 26 to 50 years, purposively recruited from public and private patient waiting rooms (e.g., 6 awaiting initial diagnosis; 14 in surveillance). Data were analyzed inductively using reflexive thematic analysis. Results: Three themes captured women’s experiences. (1) Psychological distress and threat appraisal: anxiety, fear, reduced self-esteem, and fertility concerns, most acute during initial diagnosis. (2) Adjustment and coping strategies: reliance on religious belief, family/partner support, lifestyle modifications, and complementary therapies, with ambivalence toward surgical treatment largely driven by concerns about potential effects on infertility. (3) Healthcare encounters and information gaps: inconsistent communication and counseling that led women to rely on informal sources of information. Conclusion: A diagnosis of uterine leiomyomas can be marked by substantial emotional burden, influenced by cultural beliefs, fertility expectations, and variable healthcare communication.
- 19 May 2026
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 42  (6) , 477-484
Sonographic Diagnosis of Uterine Fibroids and the Associated Patient Experience: The Psychosocial and Cultural Challenges Encountered
Objective: To explore the psychological impact, coping strategies, and healthcare experiences of African women undergoing a sonographic diagnosis of uterine fibroids, guided by the Lazarus Stress and Coping Theory and the Engel Biopsychosocial Model. Materials and Methods: Semi-structured interviews were conducted with 20 Nigerian women aged 26 to 50 years, purposively recruited from public and private patient waiting rooms (e.g., 6 awaiting initial diagnosis; 14 in surveillance). Data were analyzed inductively using reflexive thematic analysis. Results: Three themes captured women’s experiences. (1) Psychological distress and threat appraisal: anxiety, fear, reduced self-esteem, and fertility concerns, most acute during initial diagnosis. (2) Adjustment and coping strategies: reliance on religious belief, family/partner support, lifestyle modifications, and complementary therapies, with ambivalence toward surgical treatment largely driven by concerns about potential effects on infertility. (3) Healthcare encounters and information gaps: inconsistent communication and counseling that led women to rely on informal sources of information. Conclusion: A diagnosis of uterine leiomyomas can be marked by substantial emotional burden, influenced by cultural beliefs, fertility expectations, and variable healthcare communication.
- Open Access
- 30 January 2026
- Published by SJORANM GmbH in Swiss Journal of Radiology and Nuclear Medicine
- Vol. 27  (1) , 33-42
Radiographers’ Perceptions of Artificial Intelligence and Theranostics
Background: Artificial Intelligence (AI) and theranostics are transforming radiographic practice by enhancing diagnostic precision and enabling personalized treatment. However, these innovations raise concerns about professional adaptation and job security. Objectives: To investigate Nigerian radiographers’ awareness, perceptions, and adaptability regarding these technologies, with a focus on job security and professional relevance. Method: A cross-sectional survey of 349 Nigerian radiographers assessed awareness, perceptions, and adaptability regarding AI and theranostics. Data were analyzed using descriptive statistics (SPSS v25). Results: Awareness was higher for AI than theranostics: 31.2% were moderately familiar and 28.7% very familiar with AI, whereas 34.4% were not familiar with theranostics. Most respondents (64.5%) had not attended training or seminars. Regarding possible role displacement through automation, 107 respondents (30.7%) agreed and 35 (10.0%) strongly agreed. Further education or certification attracted agreement from 179 respondents (51.3%) and strong agreement from 79 (22.6%). Adoption as an opportunity for career growth attracted agreement from 168 respondents (48.1%) and strong agreement from 93 (26.6%). Key adaptation factors included mentorship (50.7% in the agree category), financial support (45.6% in the agree category), and curriculum integration (41.5% in the agree category). Conclusion: Nigerian radiographers demonstrate moderate familiarity with AI but limited understanding of theranostics. While job security concerns persist, willingness to upskill is strong. Structured training, mentorship, and curriculum reform are essential to support professional adaptation and safeguard radiographers’ relevance in the era of AI and theranostics. Contribution: This study highlights the need for radiography professional bodies and policymakers to prioritize structured training pathways, financial incentives, and cross-disciplinary collaborations to ensure radiographers remain central to technological transitions.
- 30 January 2026
- Published by SJORANM GmbH in Swiss Journal of Radiology and Nuclear Medicine
- Vol. 27  (1) , 33-42
Open AccessRadiographers’ Perceptions of Artificial Intelligence and Theranostics
Background: Artificial Intelligence (AI) and theranostics are transforming radiographic practice by enhancing diagnostic precision and enabling personalized treatment. However, these innovations raise concerns about professional adaptation and job security. Objectives: To investigate Nigerian radiographers’ awareness, perceptions, and adaptability regarding these technologies, with a focus on job security and professional relevance. Method: A cross-sectional survey of 349 Nigerian radiographers assessed awareness, perceptions, and adaptability regarding AI and theranostics. Data were analyzed using descriptive statistics (SPSS v25). Results: Awareness was higher for AI than theranostics: 31.2% were moderately familiar and 28.7% very familiar with AI, whereas 34.4% were not familiar with theranostics. Most respondents (64.5%) had not attended training or seminars. Regarding possible role displacement through automation, 107 respondents (30.7%) agreed and 35 (10.0%) strongly agreed. Further education or certification attracted agreement from 179 respondents (51.3%) and strong agreement from 79 (22.6%). Adoption as an opportunity for career growth attracted agreement from 168 respondents (48.1%) and strong agreement from 93 (26.6%). Key adaptation factors included mentorship (50.7% in the agree category), financial support (45.6% in the agree category), and curriculum integration (41.5% in the agree category). Conclusion: Nigerian radiographers demonstrate moderate familiarity with AI but limited understanding of theranostics. While job security concerns persist, willingness to upskill is strong. Structured training, mentorship, and curriculum reform are essential to support professional adaptation and safeguard radiographers’ relevance in the era of AI and theranostics. Contribution: This study highlights the need for radiography professional bodies and policymakers to prioritize structured training pathways, financial incentives, and cross-disciplinary collaborations to ensure radiographers remain central to technological transitions.
- 25 October 2025
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 42  (3) , 225-232
Variations in Hepatic Doppler Indices in Patients Presenting With Fatty Liver Disease: A Meta-Analysis
Objective: Fatty liver disease (FLD) affects hepatic hemodynamics, which can be assessed using Doppler indices. Understanding variations in these indices can enhance noninvasive diagnostic and monitoring tools for FLD. The aim of this review was to assess and analyze variations in hepatic artery resistive index (HARI), portal vein pulsatility index (PVPI), and portal vein velocity (PVV) in patients with FLD. Materials and Methods: This study reviewed variations in hepatic Doppler indices in patients with fatty liver disease (FLD) by analyzing peer-reviewed studies published between 2000 and 2024. A total of 52 articles were identified across several scientific databases, using Boolean operators and relevant search phrases. The meta-analysis utilized a random-effects model to account for heterogeneity, which was further assessed using chi-square tests ( p < .05) and I² statistics (low: ≤ 25%, moderate: 50%, high: ≥75%). Results: The procured data revealed that FLD patients exhibited significantly lower HARI (15% reduction), VPI (10% reduction), and PVV (25% reduction) than healthy controls ( p < .05), indicating reduced portal vein flow and increased hepatic artery flow. The liver compensated for fatty infiltrations in hepatic portal vessels by vasodilation of the hepatic arteries, increasing hepatic artery flow, and decreasing HARI. The severity of FLD in the study participant samples was found to influence Doppler indices, emphasizing their potential as noninvasive biomarkers for diagnosing and monitoring FLD. Conclusion: This literature review was focused on FLD, which has been consistently associated with reduced portal vein indices and compensatory increases in hepatic artery flow. Variations in HARI, PVPI, and PVV reflected both the hemodynamic consequences of fatty infiltration and the liver’s compensatory adaptations. It may be clinically valuable to further explore these parameters, as noninvasive biomarkers for the diagnosis, staging, and monitoring of FLD.
- 25 October 2025
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 42  (3) , 225-232
Variations in Hepatic Doppler Indices in Patients Presenting With Fatty Liver Disease: A Meta-Analysis
Objective: Fatty liver disease (FLD) affects hepatic hemodynamics, which can be assessed using Doppler indices. Understanding variations in these indices can enhance noninvasive diagnostic and monitoring tools for FLD. The aim of this review was to assess and analyze variations in hepatic artery resistive index (HARI), portal vein pulsatility index (PVPI), and portal vein velocity (PVV) in patients with FLD. Materials and Methods: This study reviewed variations in hepatic Doppler indices in patients with fatty liver disease (FLD) by analyzing peer-reviewed studies published between 2000 and 2024. A total of 52 articles were identified across several scientific databases, using Boolean operators and relevant search phrases. The meta-analysis utilized a random-effects model to account for heterogeneity, which was further assessed using chi-square tests ( p < .05) and I² statistics (low: ≤ 25%, moderate: 50%, high: ≥75%). Results: The procured data revealed that FLD patients exhibited significantly lower HARI (15% reduction), VPI (10% reduction), and PVV (25% reduction) than healthy controls ( p < .05), indicating reduced portal vein flow and increased hepatic artery flow. The liver compensated for fatty infiltrations in hepatic portal vessels by vasodilation of the hepatic arteries, increasing hepatic artery flow, and decreasing HARI. The severity of FLD in the study participant samples was found to influence Doppler indices, emphasizing their potential as noninvasive biomarkers for diagnosing and monitoring FLD. Conclusion: This literature review was focused on FLD, which has been consistently associated with reduced portal vein indices and compensatory increases in hepatic artery flow. Variations in HARI, PVPI, and PVV reflected both the hemodynamic consequences of fatty infiltration and the liver’s compensatory adaptations. It may be clinically valuable to further explore these parameters, as noninvasive biomarkers for the diagnosis, staging, and monitoring of FLD.
- 21 October 2022
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 53  (4) , 681-685
Normative values of the alpha angle and triangular index measured from the hip radiographs of an African population
- 21 October 2022
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 53  (4) , 681-685
Normative values of the alpha angle and triangular index measured from the hip radiographs of an African population
- 1 May 2022
- Published by Elsevier in Radiography
- Vol. 28  (2) , 473-479
Sonographic prediction of successful embryonic implantation in in-vitro fertilization and embryo transfer cycle procedures, using a multi-parameter approach
- 1 May 2022
- Published by Elsevier in Radiography
- Vol. 28  (2) , 473-479
Sonographic prediction of successful embryonic implantation in in-vitro fertilization and embryo transfer cycle procedures, using a multi-parameter approach
- Open Access
- 1 January 2022
- Published by Association of Radiographers of Nigeria in Journal of Radiography and Radiation Sciences
- Vol. 36  (1) , 5-11
RADIOGRAPHIC DETERMINATION OF NORMAL RANGE VALUES OF ACROMIOCLAVICULAR JOINT SPACE IN NIGERIAN POPULATION
Background: Acromioclavicular joint space is one of the most common injuries of the shoulder region. Accurate diagnosis of most acromioclavicular (AC) joint pathologies depends on the knowledge of the normal range values of acromioclavicular joint space. The variation in the normal AC joint spaces among the studied population points to the need to have population-specific reference range values of acromioclavicular joint space while the paucity of data on normal acromioclavicular joint space diameter in our locality necessitated this study. Objective: This study was, therefore, aimed at radiographically determining the normal reference range values of acromioclavicular joint space diameter with age in adult Nigerian and also to find its variation with sex. Methods: This retrospective study was conducted in three tertiary hospitals in Enugu from January 2019 to July 2019. It involved digital anteroposterior shoulder radiographs of 628 adults (18 – 80 years) obtained using Zanca’s view and reported as normal by four consultant radiologists. The acromioclavicular joint space diameter is calculated as an integral of the distances between the superior and inferior borders of the acromioclavicular joint space. Data were analyzed using a linear regression model, Pearson product-moment correlation coefficient, and independent sample t-test. Results: The mean AC joint space diameter ranged from 3.63 mm at ≤ 20 years to 1.14 mm at 76-80 years of age. Acromioclavicular joint space diameter correlated strongly but negatively with age with correlation coefficients of -0.785, -.839, -.797, and -.780. There was a significant difference between the acromioclavicular joint space diameter of males and females (p = 0.000). Conclusion: This study has generated a reference range value of normal acromioclavicular joint space diameter with age in our locality while there is a difference in acromioclavicular joint space between male and female adult Nigerians.
- 1 January 2022
- Published by Association of Radiographers of Nigeria in Journal of Radiography and Radiation Sciences
- Vol. 36  (1) , 5-11
Open AccessRADIOGRAPHIC DETERMINATION OF NORMAL RANGE VALUES OF ACROMIOCLAVICULAR JOINT SPACE IN NIGERIAN POPULATION
Background: Acromioclavicular joint space is one of the most common injuries of the shoulder region. Accurate diagnosis of most acromioclavicular (AC) joint pathologies depends on the knowledge of the normal range values of acromioclavicular joint space. The variation in the normal AC joint spaces among the studied population points to the need to have population-specific reference range values of acromioclavicular joint space while the paucity of data on normal acromioclavicular joint space diameter in our locality necessitated this study. Objective: This study was, therefore, aimed at radiographically determining the normal reference range values of acromioclavicular joint space diameter with age in adult Nigerian and also to find its variation with sex. Methods: This retrospective study was conducted in three tertiary hospitals in Enugu from January 2019 to July 2019. It involved digital anteroposterior shoulder radiographs of 628 adults (18 – 80 years) obtained using Zanca’s view and reported as normal by four consultant radiologists. The acromioclavicular joint space diameter is calculated as an integral of the distances between the superior and inferior borders of the acromioclavicular joint space. Data were analyzed using a linear regression model, Pearson product-moment correlation coefficient, and independent sample t-test. Results: The mean AC joint space diameter ranged from 3.63 mm at ≤ 20 years to 1.14 mm at 76-80 years of age. Acromioclavicular joint space diameter correlated strongly but negatively with age with correlation coefficients of -0.785, -.839, -.797, and -.780. There was a significant difference between the acromioclavicular joint space diameter of males and females (p = 0.000). Conclusion: This study has generated a reference range value of normal acromioclavicular joint space diameter with age in our locality while there is a difference in acromioclavicular joint space between male and female adult Nigerians.
- 5 November 2021
- Published by Association of Radiographers of Nigeria in Journal of Radiography and Radiation Sciences
- Vol. 35  (2) , 1-7
THE PRACTICE AND IMPLEMENTATION OF RADIATION MONITORING OF RADIOGRAPHERS IN TERTIARY HOSPITALS IN SOUTHEASTERN NIGERIA: A REASSESSMENT
Background: Radiation monitoring is an essential radiation safety practice that helps to determine the cumulative radiation dose absorbed by radiographers, ensuring that it does not exceed permissible limits. Failure in practice and implementation of radiation monitoring exposes radiographers to stochastic effects of radiation exposure, increasing the hazard radiation workers are exposed to. Objective: To reassess the practice and implementation of radiation monitoring of radiographers working in south-eastern tertiary hospitals in Nigeria. Methods: This was a cross-sectional survey involving 102 radiographers from 5 selected South-Eastern tertiary hospitals. Proportional stratified random sampling was used to select the radiographers from each tertiary hospital while a semi-structured questionnaire in line with the specific objectives was used as the method for data collection. Information obtained from the respondents was related to established radiation monitoring requirements and tables were used for data presentation. Results: With a perfect response rate from the 102 respondents, personnel radiation monitoring was available to only 31% (n = 32) of the respondents with 59% (n = 19) using Thermoluminiscent dosimeters. Even though a majority (71.9%, n=23) wore their dosimeters daily, only half (50%, n = 16) of those monitored had routine device retrieval and feedback of reading at the appropriate time. Employees did not demand radiation monitoring history from the radiographers before employment and only 10% (n = 3) of those monitored claimed they had dosimetry records. Lastly, only 6.3% (n = 2) of radiographers have been on leave as a direct result of over-exposure to radiation. Conclusion: Personnel radiation monitoring practices of radiographers in South-Eastern tertiary hospitals still remain below internationally acceptable standards. Comparing the findings of this study with a similar study carried out 10 years ago, there has been little improvement in the radiation monitoring of radiographers. The management of tertiary health institutions should ensure that personnel monitoring devices are made available to radiographers, and stricter rules should be placed on the daily wearing of dosimeters.
- 5 November 2021
- Published by Association of Radiographers of Nigeria in Journal of Radiography and Radiation Sciences
- Vol. 35  (2) , 1-7
THE PRACTICE AND IMPLEMENTATION OF RADIATION MONITORING OF RADIOGRAPHERS IN TERTIARY HOSPITALS IN SOUTHEASTERN NIGERIA: A REASSESSMENT
Background: Radiation monitoring is an essential radiation safety practice that helps to determine the cumulative radiation dose absorbed by radiographers, ensuring that it does not exceed permissible limits. Failure in practice and implementation of radiation monitoring exposes radiographers to stochastic effects of radiation exposure, increasing the hazard radiation workers are exposed to. Objective: To reassess the practice and implementation of radiation monitoring of radiographers working in south-eastern tertiary hospitals in Nigeria. Methods: This was a cross-sectional survey involving 102 radiographers from 5 selected South-Eastern tertiary hospitals. Proportional stratified random sampling was used to select the radiographers from each tertiary hospital while a semi-structured questionnaire in line with the specific objectives was used as the method for data collection. Information obtained from the respondents was related to established radiation monitoring requirements and tables were used for data presentation. Results: With a perfect response rate from the 102 respondents, personnel radiation monitoring was available to only 31% (n = 32) of the respondents with 59% (n = 19) using Thermoluminiscent dosimeters. Even though a majority (71.9%, n=23) wore their dosimeters daily, only half (50%, n = 16) of those monitored had routine device retrieval and feedback of reading at the appropriate time. Employees did not demand radiation monitoring history from the radiographers before employment and only 10% (n = 3) of those monitored claimed they had dosimetry records. Lastly, only 6.3% (n = 2) of radiographers have been on leave as a direct result of over-exposure to radiation. Conclusion: Personnel radiation monitoring practices of radiographers in South-Eastern tertiary hospitals still remain below internationally acceptable standards. Comparing the findings of this study with a similar study carried out 10 years ago, there has been little improvement in the radiation monitoring of radiographers. The management of tertiary health institutions should ensure that personnel monitoring devices are made available to radiographers, and stricter rules should be placed on the daily wearing of dosimeters.
- 1 May 2021
- Published by Elsevier in Radiography
- Vol. 27  (2) , 581-588
Measuring wall shear stress distribution in the carotid artery in an African population: Computational fluid dynamics versus ultrasound doppler velocimetry
- 1 May 2021
- Published by Elsevier in Radiography
- Vol. 27  (2) , 581-588
Measuring wall shear stress distribution in the carotid artery in an African population: Computational fluid dynamics versus ultrasound doppler velocimetry
- Open Access
- 22 August 2019
- Published by Springer Nature in BMC Medical Imaging
- Vol. 19  (1) , 1-7
Sonographic estimation of gestational age from 20 to 40 weeks by fetal kidney lengths’ measurements among pregnant women in Portharcourt, Nigeria
Ultrasonography has become an indispensible tool in the management of obstetric patients. Accurate determination of fetal gestational age (FGA) has posed great challenge to patient management as the accuracy of traditional biometric parameters decreases with advance in gestation age. Accuracy of fetal kidney length (FKL) in the determination of FGA at third trimester has been documented in other population. This study is aimed to create baseline reference values of fetal kidney lengths in a Nigerian population as previous studies show population specific variations. This prospective cross sectional study was carried out on 534 pregnant women between 20 and 40 weeks of gestation who met the inclusion criteria at Diamond Biomedical Services Ltd. A pilot study was conducted on 20 patients to determine the reproducibility and reliability of ultrasound measurement of FKL. Fetal kidney lengths were calculated as mean of three separate measurements. The 5th, 50th and 95th percentiles were calculated using least squared regression analysis. Third polynomial regression models were used to establish the relationship between right and left FKL and FGA. Both FKL measurements are highly reproducible with excellent correlation and agreement within and between sonographers. It correlates strongly with gestational age while the relationships between right and left kidney lengths with gestational age were established using the following regression equations: RKL = − 11.18 + 1.193 × FGA − 0.0350 × FGA2 + 0.00037 × FGA3 and LKL = − 12.57 + 1.332 × FGA − 0.0390 × FGA2 + 0.00040 × FGA3 for right and left kidneys respectively. Nigerian population specific baseline reference values of FKLs for the estimation of FGA should be adopted rather than relying on the Caucasians values as universal patterns.
- 22 August 2019
- Published by Springer Nature in BMC Medical Imaging
- Vol. 19  (1) , 1-7
Open AccessSonographic estimation of gestational age from 20 to 40 weeks by fetal kidney lengths’ measurements among pregnant women in Portharcourt, Nigeria
Ultrasonography has become an indispensible tool in the management of obstetric patients. Accurate determination of fetal gestational age (FGA) has posed great challenge to patient management as the accuracy of traditional biometric parameters decreases with advance in gestation age. Accuracy of fetal kidney length (FKL) in the determination of FGA at third trimester has been documented in other population. This study is aimed to create baseline reference values of fetal kidney lengths in a Nigerian population as previous studies show population specific variations. This prospective cross sectional study was carried out on 534 pregnant women between 20 and 40 weeks of gestation who met the inclusion criteria at Diamond Biomedical Services Ltd. A pilot study was conducted on 20 patients to determine the reproducibility and reliability of ultrasound measurement of FKL. Fetal kidney lengths were calculated as mean of three separate measurements. The 5th, 50th and 95th percentiles were calculated using least squared regression analysis. Third polynomial regression models were used to establish the relationship between right and left FKL and FGA. Both FKL measurements are highly reproducible with excellent correlation and agreement within and between sonographers. It correlates strongly with gestational age while the relationships between right and left kidney lengths with gestational age were established using the following regression equations: RKL = − 11.18 + 1.193 × FGA − 0.0350 × FGA2 + 0.00037 × FGA3 and LKL = − 12.57 + 1.332 × FGA − 0.0390 × FGA2 + 0.00040 × FGA3 for right and left kidneys respectively. Nigerian population specific baseline reference values of FKLs for the estimation of FGA should be adopted rather than relying on the Caucasians values as universal patterns.
- Open Access
- 31 July 2019
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 35  (6) , 453-458
Correlating Carotid Intima-Media Thickness With Lipid Profile: Does It Improve Sonographic Diagnosis of Subclinical Atherosclerosis?
Objective. The purpose of this prospective study was to ascertain if lipid profile parameters could serve as predictors of carotid intima-media thickness (CIMT), which, when combined, may improve the sensitivity of sonographic CIMT measurement in the diagnosis of subclinical atherosclerotic changes. Methods. The lipid profiles and CIMT of 181 subjects without cardiovascular risk factors were measured at the internal, external, common, and bulbar segments. Results. The mean CIMT values obtained were 0.620 ± 0.055 cm for men and 0.575 ± 0.051 cm for women, and the η2 values (η2 < 0.04) were used as a measure of association. Across all segments of both carotid arteries, lipid profiles were significantly and moderately associated with but not predictive of CIMT (fasting blood sugar, total cholesterol, and low-density lipoprotein: η2 = 0.99–0.24). Conclusions. Although lipid profiles were moderately associated with CIMT, they are not significant predictors; hence, combining them with CIMT does not improve the diagnostic sensitivity of sonography in atherosclerosis screening.
- 31 July 2019
- Published by SAGE Publications in Journal of Diagnostic Medical Sonography
- Vol. 35  (6) , 453-458
Open AccessCorrelating Carotid Intima-Media Thickness With Lipid Profile: Does It Improve Sonographic Diagnosis of Subclinical Atherosclerosis?
Objective. The purpose of this prospective study was to ascertain if lipid profile parameters could serve as predictors of carotid intima-media thickness (CIMT), which, when combined, may improve the sensitivity of sonographic CIMT measurement in the diagnosis of subclinical atherosclerotic changes. Methods. The lipid profiles and CIMT of 181 subjects without cardiovascular risk factors were measured at the internal, external, common, and bulbar segments. Results. The mean CIMT values obtained were 0.620 ± 0.055 cm for men and 0.575 ± 0.051 cm for women, and the η2 values (η2 < 0.04) were used as a measure of association. Across all segments of both carotid arteries, lipid profiles were significantly and moderately associated with but not predictive of CIMT (fasting blood sugar, total cholesterol, and low-density lipoprotein: η2 = 0.99–0.24). Conclusions. Although lipid profiles were moderately associated with CIMT, they are not significant predictors; hence, combining them with CIMT does not improve the diagnostic sensitivity of sonography in atherosclerosis screening.