Yanping Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yanping Wang has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Yujun Song
Division of Colorectal Surgery, Department of General Surgery, Nanjing Drum Tower Hospital, College of Engineering and Applied Sciences, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing 210023, China
6 shared publications - Yanfeng Gao
School of Medical Imaging, Wannan Medical University, Wuhu 241002, China
5 shared publications A. Létoublon
2 shared publications- Charles Cornet
Univ Rennes
2 shared publications - Gilles Patriarche
Centre de Nanosciences et de Nanotechnologies
2 shared publications - Mounib Bahri
Albert Crewe Centre for Electron Microscopy University of Liverpool Liverpool L69 3GL UK
2 shared publications
Latest Publications
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Structural analyses by advanced X-ray scattering on GaP layers epitaxially grown on silicon for integrated photonic applications
Analyses structurales par diffusion des rayons X de couches epitaxiées de GaP sur silicium pour des applications en photonique intégrée: Cette thèse porte sur le développement des méthodes d'analyse structurale de la couche mince de GaP epitaxiées sur le substrat de silicium par l'épitaxie par jets moléculaires (MBE), basées sur la diffraction des rayons X (ORX) et combinées à des techniques complémentaires telles que la microscopie électronique en transmission (TEM), la microscopie à force atomique (AFM) et la microscopie à effet tunnel (STM). Le travail est centré sur la caractérisation quantitative de la densité des défauts cristallins comme les micro-macles et les domaines d'inversion présents dans la couche ainsi que l'évaluation de la qualité de surface et l'interface. L'objectif ultime est d'obtenir une plate-forme GaP/Si parfaitement cristallisée sans défaut, via l'optimisation des paramètres de croissance. Nous avons mis en place et utilisé deux méthodes de quantification des micro-macles par la diffraction des rayons X en condition de laboratoire : les figures de pôles pour la visualisation rapide et l'évaluation de la densité des micro-macles et les « rocking-curves » permettent une extraction précise de la faction volumique de domaine maclé. Les propriétés structurales de la plate-forme de GaP/Si ont été considérablement améliorées, après une procédure d'optimisation impliquant la température de croissance, une procédure de croissance alternée (MEE) et une séquence de croissance en deux étapes. Un échantillon quasiment sans micro-macles a été obtenu par le dépôt de 40 monocouches de GaP par MEE à 350 •c suivi d'une surcroissance de 40 nm de GaP par MBE continue, à 500 •c. La surface de l'échantillon est lisse avec une rugosité de 0.3 nm. L'évaluation des domaines d'inversion par la ORX a été effectuée sur les cartographies de l'espace réciproque centrées sur les réflexions GaP de type (OOL), en laboratoire et sur une ligne synchrotron. Les balayages « transverses » extrait à partir des cartographies de l'espace réciproque sont analysés via une méthode dite "Williamson-Hall like", afin d'obtenir la "mosaïcité" qui est reliée à la micro-désorientation des petits domaines cristallins et la longueur de corrélation latérale correspondant à ces petits domaines. La distance moyenne entre parois de domaines d'inversion et ensuite estimé à partir de cette mesure. En utilisant cette méthode d'analyse et les techniques microscopiques, une optimisation plus poussée a été effectuée sur la dose de Ga au stade initial de croissance, l'utilisation de couches de marqueur AIGaP et l'homoépitaxie d'une couche de silicium avant le GaP. Enfin, nous avons obtenu un échantillon ne présentant pas de signal de micro-macle détectable en conditions standard de laboratoire, et une très faible densité de domaine d'inversion. Nous avons aussi observé une interface de GaP/Si visiblement présentant des bi-marches atomiques très régulières, sur un échantillon avec une couche de silicium déposée avant la croissance du GaP.
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Structural analyses by advanced X-ray scattering on GaP layers epitaxially grown on silicon for integrated photonic applications
Analyses structurales par diffusion des rayons X de couches epitaxiées de GaP sur silicium pour des applications en photonique intégrée: Cette thèse porte sur le développement des méthodes d'analyse structurale de la couche mince de GaP epitaxiées sur le substrat de silicium par l'épitaxie par jets moléculaires (MBE), basées sur la diffraction des rayons X (ORX) et combinées à des techniques complémentaires telles que la microscopie électronique en transmission (TEM), la microscopie à force atomique (AFM) et la microscopie à effet tunnel (STM). Le travail est centré sur la caractérisation quantitative de la densité des défauts cristallins comme les micro-macles et les domaines d'inversion présents dans la couche ainsi que l'évaluation de la qualité de surface et l'interface. L'objectif ultime est d'obtenir une plate-forme GaP/Si parfaitement cristallisée sans défaut, via l'optimisation des paramètres de croissance. Nous avons mis en place et utilisé deux méthodes de quantification des micro-macles par la diffraction des rayons X en condition de laboratoire : les figures de pôles pour la visualisation rapide et l'évaluation de la densité des micro-macles et les « rocking-curves » permettent une extraction précise de la faction volumique de domaine maclé. Les propriétés structurales de la plate-forme de GaP/Si ont été considérablement améliorées, après une procédure d'optimisation impliquant la température de croissance, une procédure de croissance alternée (MEE) et une séquence de croissance en deux étapes. Un échantillon quasiment sans micro-macles a été obtenu par le dépôt de 40 monocouches de GaP par MEE à 350 •c suivi d'une surcroissance de 40 nm de GaP par MBE continue, à 500 •c. La surface de l'échantillon est lisse avec une rugosité de 0.3 nm. L'évaluation des domaines d'inversion par la ORX a été effectuée sur les cartographies de l'espace réciproque centrées sur les réflexions GaP de type (OOL), en laboratoire et sur une ligne synchrotron. Les balayages « transverses » extrait à partir des cartographies de l'espace réciproque sont analysés via une méthode dite "Williamson-Hall like", afin d'obtenir la "mosaïcité" qui est reliée à la micro-désorientation des petits domaines cristallins et la longueur de corrélation latérale correspondant à ces petits domaines. La distance moyenne entre parois de domaines d'inversion et ensuite estimé à partir de cette mesure. En utilisant cette méthode d'analyse et les techniques microscopiques, une optimisation plus poussée a été effectuée sur la dose de Ga au stade initial de croissance, l'utilisation de couches de marqueur AIGaP et l'homoépitaxie d'une couche de silicium avant le GaP. Enfin, nous avons obtenu un échantillon ne présentant pas de signal de micro-macle détectable en conditions standard de laboratoire, et une très faible densité de domaine d'inversion. Nous avons aussi observé une interface de GaP/Si visiblement présentant des bi-marches atomiques très régulières, sur un échantillon avec une couche de silicium déposée avant la croissance du GaP.
- Open Access
- 28 October 2025
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 5 (2) , 116-135
Microfluidic platforms for CRISPR-based biosensing advancing molecular diagnostics from benchtop to point-of-care
This review highlights recent advances in microfluidics-integrated CRISPR–Cas systems for rapid, sensitive, and portable detection of diverse biomarkers, emphasizing their potential to enable sample-to-answer point-of-care diagnostics.
- 28 October 2025
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 5 (2) , 116-135
Open AccessMicrofluidic platforms for CRISPR-based biosensing advancing molecular diagnostics from benchtop to point-of-care
This review highlights recent advances in microfluidics-integrated CRISPR–Cas systems for rapid, sensitive, and portable detection of diverse biomarkers, emphasizing their potential to enable sample-to-answer point-of-care diagnostics.
- 4 December 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 503
A portable microfluidic platform for ultra-sensitive detection of ovarian cancer biomarkers via cascade signal amplification
- 4 December 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 503
A portable microfluidic platform for ultra-sensitive detection of ovarian cancer biomarkers via cascade signal amplification
- 28 November 2024
- Published by Wiley in ChemBioChem
- Vol. 26 (5) , e202400807
Synthesis and Biomedical Applications of Covalent Organic Frameworks for Disease Diagnosis and Therapy
Covalent organic frameworks (COFs) have emerged as a distinguished class of porous materials. Owing to their ability to be constructed through covalent bonds involving light elements, such as hydrogen, boron, carbon, nitrogen, and oxygen, COFs offer greater stability and lower cytotoxicity than metal–organic frameworks do, addressing critical limitations in in vivo applications. Their unique attributes, such as high surface area, customizable pore sizes, and versatile surface functionalities, make them ideal for various biomedical applications. This review aims to provide an overview of the recent advancements in modern COFs for biomedical uses. First, a variety of methods for the synthesis of COFs are outlined, which ensures their suitability for medical use. Next, we delve into innovative biomedical applications, emphasizing their roles in disease diagnosis and therapies. Finally, challenges, such as clinical translation, biocompatibility, and controlled drug release, are critically discussed, providing comprehensive insight into the potential of COFs in revolutionizing biomedical technologies. Overall, this review offers a comprehensive overview of COFs’ capabilities and future prospects in enhancing biomedical technologies.
- 28 November 2024
- Published by Wiley in ChemBioChem
- Vol. 26 (5) , e202400807
Synthesis and Biomedical Applications of Covalent Organic Frameworks for Disease Diagnosis and Therapy
Covalent organic frameworks (COFs) have emerged as a distinguished class of porous materials. Owing to their ability to be constructed through covalent bonds involving light elements, such as hydrogen, boron, carbon, nitrogen, and oxygen, COFs offer greater stability and lower cytotoxicity than metal–organic frameworks do, addressing critical limitations in in vivo applications. Their unique attributes, such as high surface area, customizable pore sizes, and versatile surface functionalities, make them ideal for various biomedical applications. This review aims to provide an overview of the recent advancements in modern COFs for biomedical uses. First, a variety of methods for the synthesis of COFs are outlined, which ensures their suitability for medical use. Next, we delve into innovative biomedical applications, emphasizing their roles in disease diagnosis and therapies. Finally, challenges, such as clinical translation, biocompatibility, and controlled drug release, are critically discussed, providing comprehensive insight into the potential of COFs in revolutionizing biomedical technologies. Overall, this review offers a comprehensive overview of COFs’ capabilities and future prospects in enhancing biomedical technologies.
- 18 November 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (1) , 49-56
Detecting telomerase activity at the single-cell level using a CRISPR-Cas12a-based chip
The intimate association between telomerase activity and cancer has driven the exploration of diverse methodologies for its precise detection. However, detecting telomerase activity at the single-cell level remains a significant challenge. Herein, we present a MOF–DNA barcode-amplified CRISPR-Cas12a strategy integrated with a single-cell microfluidic chip for ultrasensitive detection of telomerase activity. DNA-functionalized UiO-66 nanoparticles act as signal transducers, effectively converting telomerase activity into DNA activation strands, which subsequently trigger the trans-cleavage activity of CRISPR-Cas12a. This amplification-based assay could be integrated with a microfluidic chip to enable highly sensitive detection of telomerase activity at the single-cell level, offering promising advancements in early cancer diagnosis.
- 18 November 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (1) , 49-56
Detecting telomerase activity at the single-cell level using a CRISPR-Cas12a-based chip
The intimate association between telomerase activity and cancer has driven the exploration of diverse methodologies for its precise detection. However, detecting telomerase activity at the single-cell level remains a significant challenge. Herein, we present a MOF–DNA barcode-amplified CRISPR-Cas12a strategy integrated with a single-cell microfluidic chip for ultrasensitive detection of telomerase activity. DNA-functionalized UiO-66 nanoparticles act as signal transducers, effectively converting telomerase activity into DNA activation strands, which subsequently trigger the trans-cleavage activity of CRISPR-Cas12a. This amplification-based assay could be integrated with a microfluidic chip to enable highly sensitive detection of telomerase activity at the single-cell level, offering promising advancements in early cancer diagnosis.
- 24 June 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (14) , 3521-3527
Microfluidic synthesis of hemin@ZIF-8 nanozyme with applications in cellular reactive oxygen species detection and anticancer drug screening
Zeolitic imidazolate framework-8 (ZIF-8) encapsulating enzymatically active biomolecules has emerged as a novel biocompatible nanozyme and offers significant implications for bioanalysis of various biomarkers towards early diagnosis of severe diseases such as cancers. However, the rapid, continuous and scalable synthesis of these nanozymes still remains challenging. In this work, we proposed a novel microfluidic approach for rapid and continuous synthesis of hemin@ZIF-8 nanozyme. By employing a distinctive combination of zigzag-shaped channel and spiral channel with sudden expansion structures, we have enhanced the mixing efficiency within the chip and achieved effective encapsulation of hemin in ZIF-8. The resulting hemin@ZIF-8 nanoparticles exhibit peroxidase-like activity and are capable of detecting free H2O2 with a limit of detection (LOD) as low as 45 nM, as well as H2O2 secreted by viable cells with a detection threshold of approximately 10 cells per mL. By leveraging this method, we achieved successful detection of cancer cells and effective screening of anticancer drugs that induce oxidative stress injury in cancer cells. This innovative microfluidic strategy offers a new avenue for synthesizing functional nanocomposites to facilitate the development of next-generation diagnostic tools for early disease detection and personalized medicine.
- 24 June 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (14) , 3521-3527
Microfluidic synthesis of hemin@ZIF-8 nanozyme with applications in cellular reactive oxygen species detection and anticancer drug screening
Zeolitic imidazolate framework-8 (ZIF-8) encapsulating enzymatically active biomolecules has emerged as a novel biocompatible nanozyme and offers significant implications for bioanalysis of various biomarkers towards early diagnosis of severe diseases such as cancers. However, the rapid, continuous and scalable synthesis of these nanozymes still remains challenging. In this work, we proposed a novel microfluidic approach for rapid and continuous synthesis of hemin@ZIF-8 nanozyme. By employing a distinctive combination of zigzag-shaped channel and spiral channel with sudden expansion structures, we have enhanced the mixing efficiency within the chip and achieved effective encapsulation of hemin in ZIF-8. The resulting hemin@ZIF-8 nanoparticles exhibit peroxidase-like activity and are capable of detecting free H2O2 with a limit of detection (LOD) as low as 45 nM, as well as H2O2 secreted by viable cells with a detection threshold of approximately 10 cells per mL. By leveraging this method, we achieved successful detection of cancer cells and effective screening of anticancer drugs that induce oxidative stress injury in cancer cells. This innovative microfluidic strategy offers a new avenue for synthesizing functional nanocomposites to facilitate the development of next-generation diagnostic tools for early disease detection and personalized medicine.
- 12 September 2022
- Published by Wiley in ChemMedChem
- Vol. 17 (20) , e202200422
Microfluidics‐Based Urine Biopsy for Cancer Diagnosis: Recent Advances and Future Trends
Urine biopsy, allowing for the detection, analysis and monitoring of numerous cancer‐associated urinary biomarkers to provide insights into cancer occurrence, progression and metastasis, has emerged as an attractive liquid biopsy strategy with enormous advantages over traditional tissue biopsy, such as non‐invasiveness, large sample volume, and simple sampling operation. Microfluidics enables precise manipulation of fluids in a tiny chip and exhibits outstanding performance in urine biopsy owing to its minimization, low cost, high integration, high throughput and low sample consumption. Herein, we review recent advances in microfluidic techniques employed in urine biopsy for cancer detection. After briefly summarizing the major urinary biomarkers used for cancer diagnosis, we provide an overview of the typical microfluidic techniques utilized to develop urine biopsy devices. Some prospects along with the major challenges to be addressed for the future of microfluidic‐based urine biopsy are also discussed.
- 12 September 2022
- Published by Wiley in ChemMedChem
- Vol. 17 (20) , e202200422
Microfluidics‐Based Urine Biopsy for Cancer Diagnosis: Recent Advances and Future Trends
Urine biopsy, allowing for the detection, analysis and monitoring of numerous cancer‐associated urinary biomarkers to provide insights into cancer occurrence, progression and metastasis, has emerged as an attractive liquid biopsy strategy with enormous advantages over traditional tissue biopsy, such as non‐invasiveness, large sample volume, and simple sampling operation. Microfluidics enables precise manipulation of fluids in a tiny chip and exhibits outstanding performance in urine biopsy owing to its minimization, low cost, high integration, high throughput and low sample consumption. Herein, we review recent advances in microfluidic techniques employed in urine biopsy for cancer detection. After briefly summarizing the major urinary biomarkers used for cancer diagnosis, we provide an overview of the typical microfluidic techniques utilized to develop urine biopsy devices. Some prospects along with the major challenges to be addressed for the future of microfluidic‐based urine biopsy are also discussed.
- Open Access
- 1 January 2020
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 69 (17) , 170201-170201-9
An improved Kalman filter time scale algorithm for atomic clock noise variation
Kalman filter time scale algorithm is a method of real-time estimating atomic clock state. It is of great practical value in the time-keeping work. Reliable Kalman filter time scale algorithm requires a reliable atomic clock state model, a random model and a reasonable estimation method. However, it is difficult to construct accurate state model when the noises of atomic clock change. The random model is generally based on the prior statistical information about atomic clock noises, and the prior statistical information may be distorted. In the process of time scale calculation, the noises of atomic clocks need estimating in the Kalman filter time scale algorithm, which is quantified according to the intensity of the noise. With the change of the external environment or aging of atomic clock, the noise intensity may change, resulting in the disturbance of atomic clock state estimation in the Kalman filter time scale algorithm, which further affects the accuracy and stability of the time scale. On the other hand, the error of the noise intensity estimation of atomic clocks will also affect the performance of time scale. Therefore, it is necessary to control the disturbance caused by the variation of noise intensity or the estimation error of noise intensity. In this regard, an adaptive factor is introduced to improve the Kalman filter time scale algorithm, and another adaptive factor is introduced into the state prediction covariance matrix in Kalman filter time scale algorithm. And the values of the two adaptive factors are calculated in real time by using statistics to control the growth of the state prediction covariance. The disturbance of state estimation of atomic clock is reduced, and the accuracy and stability of time scale are improved. In this paper, the sampling interval of simulated data and the measured data are 300 s and 3600 s respectively. The simulated data and measured data are used to calculate the overlapping Allan deviations of the time scale. The results show that the improved Kalman filter time scale algorithm can improve the stability of the sampling time more than 14400 s compared with classical Kalman filter time scale algorithm, and affect the stability of the sampling time less than 14400 s. The degree of influence is related to the weight algorithm of atomic clock. The measured data in this paper are treated by the “predictability” weighting algorithm, which guarantees the long-term stability of time scale. So the simulated data and measured data show that compared with classical Kalman filter time scale algorithm, the improved Kalman filter clock time scale algorithm can improve the accuracy and the long-term stability of time scale.
- 1 January 2020
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 69 (17) , 170201-170201-9
Open AccessAn improved Kalman filter time scale algorithm for atomic clock noise variation
Kalman filter time scale algorithm is a method of real-time estimating atomic clock state. It is of great practical value in the time-keeping work. Reliable Kalman filter time scale algorithm requires a reliable atomic clock state model, a random model and a reasonable estimation method. However, it is difficult to construct accurate state model when the noises of atomic clock change. The random model is generally based on the prior statistical information about atomic clock noises, and the prior statistical information may be distorted. In the process of time scale calculation, the noises of atomic clocks need estimating in the Kalman filter time scale algorithm, which is quantified according to the intensity of the noise. With the change of the external environment or aging of atomic clock, the noise intensity may change, resulting in the disturbance of atomic clock state estimation in the Kalman filter time scale algorithm, which further affects the accuracy and stability of the time scale. On the other hand, the error of the noise intensity estimation of atomic clocks will also affect the performance of time scale. Therefore, it is necessary to control the disturbance caused by the variation of noise intensity or the estimation error of noise intensity. In this regard, an adaptive factor is introduced to improve the Kalman filter time scale algorithm, and another adaptive factor is introduced into the state prediction covariance matrix in Kalman filter time scale algorithm. And the values of the two adaptive factors are calculated in real time by using statistics to control the growth of the state prediction covariance. The disturbance of state estimation of atomic clock is reduced, and the accuracy and stability of time scale are improved. In this paper, the sampling interval of simulated data and the measured data are 300 s and 3600 s respectively. The simulated data and measured data are used to calculate the overlapping Allan deviations of the time scale. The results show that the improved Kalman filter time scale algorithm can improve the stability of the sampling time more than 14400 s compared with classical Kalman filter time scale algorithm, and affect the stability of the sampling time less than 14400 s. The degree of influence is related to the weight algorithm of atomic clock. The measured data in this paper are treated by the “predictability” weighting algorithm, which guarantees the long-term stability of time scale. So the simulated data and measured data show that compared with classical Kalman filter time scale algorithm, the improved Kalman filter clock time scale algorithm can improve the accuracy and the long-term stability of time scale.
- 26 September 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (19) , 4853-4856
Characterization of free-standing 1D photonic crystals using an effective medium approach
Photonic crystals (PCs) are usually fabricated on bulk substrates which break the symmetry of the PC system for incidence from either side of the PCs. Here we report the fabrication of a free-standing 1D layered dielectric PC by using a two-beam holographic interference method. The free-standing PC exhibits distinct photonic bandgaps as well as Fabry–Perot oscillations in the photonic bands. Furthermore, we show that the PC can be modeled by an effective medium approach and obtain the reflection phase for the photonic bands of the PC. We have also performed full-wave simulations for the PC and obtained very good agreement with the experiment. The free-standing PC enables a better comparison between experiment and simulation, and importantly, it is flexible enabling new applications for PCs.
- 26 September 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (19) , 4853-4856
Characterization of free-standing 1D photonic crystals using an effective medium approach
Photonic crystals (PCs) are usually fabricated on bulk substrates which break the symmetry of the PC system for incidence from either side of the PCs. Here we report the fabrication of a free-standing 1D layered dielectric PC by using a two-beam holographic interference method. The free-standing PC exhibits distinct photonic bandgaps as well as Fabry–Perot oscillations in the photonic bands. Furthermore, we show that the PC can be modeled by an effective medium approach and obtain the reflection phase for the photonic bands of the PC. We have also performed full-wave simulations for the PC and obtained very good agreement with the experiment. The free-standing PC enables a better comparison between experiment and simulation, and importantly, it is flexible enabling new applications for PCs.
- 1 March 2018
- Published by Walter de Gruyter GmbH
Monolithic Integration of Diluted-Nitride III–V-N Compounds on Silicon Substrates: Toward the III–V/Si Concentrated Photovoltaics
GaAsPN semiconductors are promising material for the development of high-efficiency tandem solar cells on silicon substrates. GaAsPN diluted-nitride alloy is studied as the top-junction material due to its perfect lattice matching with the Si substrate and its ideal bandgap energy allowing a perfect current matching with the Si bottom cell. The GaP/Si interface is also studied in order to obtain defect-free GaP/Si pseudo-substrates suitable for the subsequent GaAsPN top junctions growth. Result shows that a double-step growth procedure suppresses most of the microtwins and a bi-stepped Si buffer can be grown, suitable to reduce the anti-phase domains density. We also review our recent progress in materials development of the GaAsPN alloy and our recent studies of all the different building blocks toward the development of a PIN solar cell. GaAsPN alloy with energy bandgap around 1.8 eV, lattice matched with the Si substrate, has been achieved. This alloy displays efficient photoluminescence at room temperature and good light absorption. An early-stage GaAsPN PIN solar cell prototype has been grown on a GaP(001) substrate. The external quantum efficiency and the I–V curve show that carriers have been extracted from the GaAsPN alloy absorber, with an open-circuit voltage above 1 eV, however a low short-circuit current density obtained suggests that GaAsPN structural properties need further optimization. Considering all the pathways for improvement, the 2.25% efficiency and IQE around 35% obtained under AM1.5G is however promising, therefore validating our approach for obtaining a lattice-matched dual-junction solar cell on silicon substrate.
- 1 March 2018
- Published by Walter de Gruyter GmbH
Monolithic Integration of Diluted-Nitride III–V-N Compounds on Silicon Substrates: Toward the III–V/Si Concentrated Photovoltaics
GaAsPN semiconductors are promising material for the development of high-efficiency tandem solar cells on silicon substrates. GaAsPN diluted-nitride alloy is studied as the top-junction material due to its perfect lattice matching with the Si substrate and its ideal bandgap energy allowing a perfect current matching with the Si bottom cell. The GaP/Si interface is also studied in order to obtain defect-free GaP/Si pseudo-substrates suitable for the subsequent GaAsPN top junctions growth. Result shows that a double-step growth procedure suppresses most of the microtwins and a bi-stepped Si buffer can be grown, suitable to reduce the anti-phase domains density. We also review our recent progress in materials development of the GaAsPN alloy and our recent studies of all the different building blocks toward the development of a PIN solar cell. GaAsPN alloy with energy bandgap around 1.8 eV, lattice matched with the Si substrate, has been achieved. This alloy displays efficient photoluminescence at room temperature and good light absorption. An early-stage GaAsPN PIN solar cell prototype has been grown on a GaP(001) substrate. The external quantum efficiency and the I–V curve show that carriers have been extracted from the GaAsPN alloy absorber, with an open-circuit voltage above 1 eV, however a low short-circuit current density obtained suggests that GaAsPN structural properties need further optimization. Considering all the pathways for improvement, the 2.25% efficiency and IQE around 35% obtained under AM1.5G is however promising, therefore validating our approach for obtaining a lattice-matched dual-junction solar cell on silicon substrate.