Yu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yu Chen has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Minghao Wen
Huazhong University of Science and Technology, Wuhan, China
5 shared publications - Ke Han
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
4 shared publications Ruizhi Ma
Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Technol, Wuhan 430074, Peoples R China
3 shared publicationsMinghao Wen
Huazhong University of Science and Technology
2 shared publications- Ruizhi Ma
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Xianggen Yin
Huazhong University of Science and Technology
2 shared publications
Latest Publications
- Open Access
- 27 April 2026
- Published by MDPI AG in Electronics
- Vol. 15 (9) , 1844
Coordinated Optimization Method for Post-Disaster Transmission Line Repair and System Restoration Against Ice and Snow Disasters
A coordinated optimization method for emergency repair scheduling and system operation restoration is proposed to address large-scale transmission line outages caused by extreme weather events such as ice and snow disasters. First, an active outage scenario for transmission lines is constructed based on the Jones icing thickness model and an exponential failure probability model, while incorporating the spatial distribution characteristics of ice disasters. Subsequently, a bi-level optimization model with repair resource constraints is developed. The upper-level model determines the transmission line repair schedule with the objective of minimizing the total repair time while taking system power supply restoration efficiency into account. Based on the completion times of line repairs, the lower-level model optimizes the system restoration process by considering power flow constraints, generator start-up processes, and load restoration characteristics. To address the challenges posed by discrete operational states and strongly coupled bi-level constraints that are difficult to solve using conventional approaches, a logic-based Integer L-shaped coordinated solution method is proposed. Finally, the effectiveness of the proposed method is validated through case studies based on the IEEE New England 10-unit 39-bus system. The results demonstrate that the proposed method can significantly improve system load restoration levels while maintaining high repair efficiency.
- 27 April 2026
- Published by MDPI AG in Electronics
- Vol. 15 (9) , 1844
Open AccessCoordinated Optimization Method for Post-Disaster Transmission Line Repair and System Restoration Against Ice and Snow Disasters
A coordinated optimization method for emergency repair scheduling and system operation restoration is proposed to address large-scale transmission line outages caused by extreme weather events such as ice and snow disasters. First, an active outage scenario for transmission lines is constructed based on the Jones icing thickness model and an exponential failure probability model, while incorporating the spatial distribution characteristics of ice disasters. Subsequently, a bi-level optimization model with repair resource constraints is developed. The upper-level model determines the transmission line repair schedule with the objective of minimizing the total repair time while taking system power supply restoration efficiency into account. Based on the completion times of line repairs, the lower-level model optimizes the system restoration process by considering power flow constraints, generator start-up processes, and load restoration characteristics. To address the challenges posed by discrete operational states and strongly coupled bi-level constraints that are difficult to solve using conventional approaches, a logic-based Integer L-shaped coordinated solution method is proposed. Finally, the effectiveness of the proposed method is validated through case studies based on the IEEE New England 10-unit 39-bus system. The results demonstrate that the proposed method can significantly improve system load restoration levels while maintaining high repair efficiency.
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (1) , 237-248
Fault Property Identification and Fault Recovery Scheme for Flexible DC Lines Based on Voltage Injection
In overhead line MMC-HVDC systems, hybrid modular multilevel converters (MMC) can limit fault currents by reducing the voltage during DC faults. For successful system recovery after fault isolation, it is critical to accurately identify the fault characteristics. However, blindly restarting the system risks causing further damage within a short time frame, compromising overall system safety. To address these concerns, this paper proposes a fault identification and system restoration scheme tailored for hybrid MMC-HVDC transmission systems. The proposed approach enhances the control of hybrid MMC injection signals, ensuring fault identification while minimizing the risk of damage to converter valves. A thorough analysis of system responses under various fault conditions is conducted. Additionally, a criterion is established using the Euclidean distance between the voltage reference value and voltage measured value to distinguish fault property. Strategies for voltage restoration and power recovery in the event of temporary faults are also presented, significantly reducing recovery time. The effectiveness of the proposed scheme is validated through simulation results under various fault conditions.
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (1) , 237-248
Fault Property Identification and Fault Recovery Scheme for Flexible DC Lines Based on Voltage Injection
In overhead line MMC-HVDC systems, hybrid modular multilevel converters (MMC) can limit fault currents by reducing the voltage during DC faults. For successful system recovery after fault isolation, it is critical to accurately identify the fault characteristics. However, blindly restarting the system risks causing further damage within a short time frame, compromising overall system safety. To address these concerns, this paper proposes a fault identification and system restoration scheme tailored for hybrid MMC-HVDC transmission systems. The proposed approach enhances the control of hybrid MMC injection signals, ensuring fault identification while minimizing the risk of damage to converter valves. A thorough analysis of system responses under various fault conditions is conducted. Additionally, a criterion is established using the Euclidean distance between the voltage reference value and voltage measured value to distinguish fault property. Strategies for voltage restoration and power recovery in the event of temporary faults are also presented, significantly reducing recovery time. The effectiveness of the proposed scheme is validated through simulation results under various fault conditions.
- Open Access
- 17 August 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 161
A single-ended high-impedance fault protection scheme for hybrid HVDC transmission lines based on coordination of control objective
- 17 August 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 161
Open AccessA single-ended high-impedance fault protection scheme for hybrid HVDC transmission lines based on coordination of control objective
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (3) , 1816-1826
A Novel Pilot Protection Scheme Based on Differential Voltage for Hybrid LCC/MMC HVDC Transmission Lines
The wide application of hybrid LCC/MMC HVDC system will be a trend in the future, and the performance of DC overhead line protection directly affects the safety of the system. The differential protection is used as backup protection to deal with high fault resistance conditions. However, it needs a long time delay to avoid mal-operation because of the distributed capacitance current. A new pilot protection scheme based on differential voltage is proposed in this paper to enhance the backup protection performance. In the proposed scheme, the compensated voltages at the setting points will be obtained from the measured voltage and current of the relay devices. The differential voltage at a setting point on the line is defined as the difference between the compensated voltages obtained by the rectifier-side relay devices and the inverter-side relay devices. The differential voltages are very tiny in external fault scenarios. Nevertheless, the differential voltages are large in internal fault scenarios. To improve the sensitivity and enhance protection performance, two setting points are set on the line. To simplify the calculation and ensure the calculation accuracy, the measured voltage and current are band-pass filtered. The proposed method has fast operation speed, simple calculation process, and can accurately estimate the fault distance. A ±800 kV hybrid LCC/MMC HVDC system is modelled in PSCAD/EMTDC to test the performance of the proposed scheme, and the effectiveness and reliability of it is verified.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (3) , 1816-1826
A Novel Pilot Protection Scheme Based on Differential Voltage for Hybrid LCC/MMC HVDC Transmission Lines
The wide application of hybrid LCC/MMC HVDC system will be a trend in the future, and the performance of DC overhead line protection directly affects the safety of the system. The differential protection is used as backup protection to deal with high fault resistance conditions. However, it needs a long time delay to avoid mal-operation because of the distributed capacitance current. A new pilot protection scheme based on differential voltage is proposed in this paper to enhance the backup protection performance. In the proposed scheme, the compensated voltages at the setting points will be obtained from the measured voltage and current of the relay devices. The differential voltage at a setting point on the line is defined as the difference between the compensated voltages obtained by the rectifier-side relay devices and the inverter-side relay devices. The differential voltages are very tiny in external fault scenarios. Nevertheless, the differential voltages are large in internal fault scenarios. To improve the sensitivity and enhance protection performance, two setting points are set on the line. To simplify the calculation and ensure the calculation accuracy, the measured voltage and current are band-pass filtered. The proposed method has fast operation speed, simple calculation process, and can accurately estimate the fault distance. A ±800 kV hybrid LCC/MMC HVDC system is modelled in PSCAD/EMTDC to test the performance of the proposed scheme, and the effectiveness and reliability of it is verified.
- Open Access
- 5 March 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (7) , 1466-1477
A pilot protection based on low frequency component model for HVDC transmission lines
Reliable and fast identification of high‐voltage direct current (HVDC) transmission line faults is important to the safety of power system. In traditional DC transmission line protection, differential protection is invulnerable to high fault resistance, but it needs long time delay for the influence of distributed capacitance current. In order to solve this problem, a novel pilot protection is proposed. The characteristics of the voltage and current processed by low‐pass filter under different fault conditions are analysed, and based on it the protection criteria is proposed. When external fault occurs, it reflects the line capacitance where the first forward fault traveling wave passes, which is increasing until equal to the whole line capacitance, then remains constant. However, when internal fault occurs, its value is negative in the initial stage, and after that its value is very different from the whole line capacitance. The analysis proves that this pilot protection method has fast operation speed, and can be applied for a relatively long period of time. What is more, the applicable time of superposition principle is considered in the analysis, which is not considered in many literatures. An UHVDC system is modelled for simulation in PSCAD/EMTDC, and the correctness and effectiveness of the proposed scheme is verified.
- 5 March 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (7) , 1466-1477
Open AccessA pilot protection based on low frequency component model for HVDC transmission lines
Reliable and fast identification of high‐voltage direct current (HVDC) transmission line faults is important to the safety of power system. In traditional DC transmission line protection, differential protection is invulnerable to high fault resistance, but it needs long time delay for the influence of distributed capacitance current. In order to solve this problem, a novel pilot protection is proposed. The characteristics of the voltage and current processed by low‐pass filter under different fault conditions are analysed, and based on it the protection criteria is proposed. When external fault occurs, it reflects the line capacitance where the first forward fault traveling wave passes, which is increasing until equal to the whole line capacitance, then remains constant. However, when internal fault occurs, its value is negative in the initial stage, and after that its value is very different from the whole line capacitance. The analysis proves that this pilot protection method has fast operation speed, and can be applied for a relatively long period of time. What is more, the applicable time of superposition principle is considered in the analysis, which is not considered in many literatures. An UHVDC system is modelled for simulation in PSCAD/EMTDC, and the correctness and effectiveness of the proposed scheme is verified.
- 31 March 2023
- Published by Springer Nature
- p. 565-573
Single-Pole Fault Injection Directional Pilot Protection for Flexible DC Lines
- 31 March 2023
- Published by Springer Nature
- p. 565-573
Single-Pole Fault Injection Directional Pilot Protection for Flexible DC Lines
- 10 March 2022
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 140
Stability analysis and control for power electronic transformer with FRT capability
- 10 March 2022
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 140
Stability analysis and control for power electronic transformer with FRT capability
- 4 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 3200-3212
An Incremental Quantities Distance Protection Using Park's Transformation
In this article, an incremental quantities distance protection using Park's transformation is proposed to increase the operation speed of distance protection. Based on the instantaneous voltage in abc frame approximate linear distribution along the AC transmission lines, this article proves that instantaneous voltage in dq frame still satisfies the approximate linear distribution along the AC transmission line. Then, the d -axis voltage components of fault point and setting point are used to determine the internal and external faults. In order to ensure that the presented distance protection can be applied to all fault types, a virtual three-phase system construction method is also presented. The fault point voltage construction method and low-pass filter design method are also discussed. Finally, a typical AC transmission system is developed in PSCAD/EMTDC to verify the performance of the proposed distance protection under different fault conditions. Simulation results indicate that the proposed incremental quantities distance protection has fast operation speed under internal metallic fault conditions and high security under external fault conditions.
- 4 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 3200-3212
An Incremental Quantities Distance Protection Using Park's Transformation
In this article, an incremental quantities distance protection using Park's transformation is proposed to increase the operation speed of distance protection. Based on the instantaneous voltage in abc frame approximate linear distribution along the AC transmission lines, this article proves that instantaneous voltage in dq frame still satisfies the approximate linear distribution along the AC transmission line. Then, the d -axis voltage components of fault point and setting point are used to determine the internal and external faults. In order to ensure that the presented distance protection can be applied to all fault types, a virtual three-phase system construction method is also presented. The fault point voltage construction method and low-pass filter design method are also discussed. Finally, a typical AC transmission system is developed in PSCAD/EMTDC to verify the performance of the proposed distance protection under different fault conditions. Simulation results indicate that the proposed incremental quantities distance protection has fast operation speed under internal metallic fault conditions and high security under external fault conditions.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 1549-1558
An Improved Fast Distance Relay to Mitigate the Impacts of Rogowski Coil Transducer Transient
The Rogowski coil transducer's integrator will amplify the transmission error, which may lead to mal-operation of the relay. In this paper, a novel method of line relay based on the differential output of Rogowski coil is proposed. Besides, an improved fast distance relay based on the differential output of Rogowski coil is presented. Based on the equal transfer process of transmission lines(ETPTL), the voltage signal should be processed by the virtual Rogowski coil to solve the inconsistent transfer problem between voltage and current. Furthermore, this paper also presents the reconstruction method of voltage at the fault point and the least-square algorithm to solve the R-L differential equation, so as to improve the algorithm accuracy. Furthermore, the equal transfer process error of the virtual Rogowski coil is analyzed in the paper, and the design principle of low pass filter is also proposed. Simulation results and experiment results demonstrate that the improved fast distance relay scheme has high operation speed, which is signed prior to other distance relay schemes. The proposed method also provides a valuable reference for other types of transmission line relay based on Rogowski coil transducer.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 1549-1558
An Improved Fast Distance Relay to Mitigate the Impacts of Rogowski Coil Transducer Transient
The Rogowski coil transducer's integrator will amplify the transmission error, which may lead to mal-operation of the relay. In this paper, a novel method of line relay based on the differential output of Rogowski coil is proposed. Besides, an improved fast distance relay based on the differential output of Rogowski coil is presented. Based on the equal transfer process of transmission lines(ETPTL), the voltage signal should be processed by the virtual Rogowski coil to solve the inconsistent transfer problem between voltage and current. Furthermore, this paper also presents the reconstruction method of voltage at the fault point and the least-square algorithm to solve the R-L differential equation, so as to improve the algorithm accuracy. Furthermore, the equal transfer process error of the virtual Rogowski coil is analyzed in the paper, and the design principle of low pass filter is also proposed. Simulation results and experiment results demonstrate that the improved fast distance relay scheme has high operation speed, which is signed prior to other distance relay schemes. The proposed method also provides a valuable reference for other types of transmission line relay based on Rogowski coil transducer.
- Open Access
- 26 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 54700-54709
Model Predictive Arm Current Control for Modular Multilevel Converter
Arm current control is a promising candidate for modular multilevel converter (MMC) due to it can effectively regulate ac-side current and control the ac component of circulating currents simultaneously. The conventional arm current controller designed in frequency domain based on classical control theory have to design the separate controller for each frequency reference signal. As a result, the controller structure is complicated. And limited by the bandwidth of the arm current compound controller, the control performance will be affected by the grid-side voltage harmonics. Model predictive control (MPC) is an optimal control method in time domain. It not only has fast dynamic response, but also can track multi-band composite signals with high accuracy. To address the above issues of traditional arm current control, this paper proposes a model predictive arm current control strategy. Combined with phase-shifted carrier pulse width modulation (PSC-PWM), the computation burden of the presented method can be independent of the number of cascaded sub-modules (SMs). Simulation and experimental results reveal the proposed MMC integrated control strategy has fast dynamic response with small tracking errors even under non-ideal grid conditions.
- 26 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 54700-54709
Open AccessModel Predictive Arm Current Control for Modular Multilevel Converter
Arm current control is a promising candidate for modular multilevel converter (MMC) due to it can effectively regulate ac-side current and control the ac component of circulating currents simultaneously. The conventional arm current controller designed in frequency domain based on classical control theory have to design the separate controller for each frequency reference signal. As a result, the controller structure is complicated. And limited by the bandwidth of the arm current compound controller, the control performance will be affected by the grid-side voltage harmonics. Model predictive control (MPC) is an optimal control method in time domain. It not only has fast dynamic response, but also can track multi-band composite signals with high accuracy. To address the above issues of traditional arm current control, this paper proposes a model predictive arm current control strategy. Combined with phase-shifted carrier pulse width modulation (PSC-PWM), the computation burden of the presented method can be independent of the number of cascaded sub-modules (SMs). Simulation and experimental results reveal the proposed MMC integrated control strategy has fast dynamic response with small tracking errors even under non-ideal grid conditions.