Minghao Wen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Minghao Wen has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Yu Chen
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
5 shared publications - Ke Han
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Xianggen Yin
Huazhong University of Science and Technology
3 shared publications Junchao Zheng
State Grid Jiangsu Electric Power Research Institute, Nanjing, Jiangsu, 210036, China
2 shared publications- Ruizhi Ma
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Xingzhu Wang
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications
Latest Publications
- Open Access
A Novel Directional Element for AC Lines in Systems with Inverter-Based Resources
The fault response of inverter-based resources (IBRs) is strongly influenced by their control strategies, which may significantly change the directional information available to line relays during non-ground faults. As a result, conventional directional elements designed according to the fault characteristics of conventional power systems may exhibit poor adaptability in IBR-connected systems. In particular, zero-sequence directional elements cannot be applied to non-ground faults, whereas negative-sequence-based schemes may be adversely affected by the fault-control behavior of IBRs. To address this problem, this paper proposes a directional element for non-ground faults on AC lines in systems with IBRs. First, the positive-sequence measured impedance at the relay locations is analyzed under typical fault conditions, and the dependence of available directional information on the phase characteristic of the IBR fault current is clarified. Then, a control–protection coordinated method is introduced to regulate the fault-current phase of the IBR during faults so that stable and consistent positive-sequence directional features can be established at both line terminals. On this basis, a unified directional criterion is formulated. Finally, PSCAD/EMTDC simulations are carried out to verify the proposed method, and dynamic model experiments are conducted to validate its engineering feasibility. The results show that the proposed element correctly identifies the fault direction under both three-phase and phase-to-phase fault conditions. Additional tests considering measurement noise and opposite-side grid-strength variation further demonstrate the robustness of the proposed criterion. Compared with conventional directional elements, the proposed method improves the adaptability of non-ground fault-direction identification in IBR-connected AC lines.
Open AccessA Novel Directional Element for AC Lines in Systems with Inverter-Based Resources
The fault response of inverter-based resources (IBRs) is strongly influenced by their control strategies, which may significantly change the directional information available to line relays during non-ground faults. As a result, conventional directional elements designed according to the fault characteristics of conventional power systems may exhibit poor adaptability in IBR-connected systems. In particular, zero-sequence directional elements cannot be applied to non-ground faults, whereas negative-sequence-based schemes may be adversely affected by the fault-control behavior of IBRs. To address this problem, this paper proposes a directional element for non-ground faults on AC lines in systems with IBRs. First, the positive-sequence measured impedance at the relay locations is analyzed under typical fault conditions, and the dependence of available directional information on the phase characteristic of the IBR fault current is clarified. Then, a control–protection coordinated method is introduced to regulate the fault-current phase of the IBR during faults so that stable and consistent positive-sequence directional features can be established at both line terminals. On this basis, a unified directional criterion is formulated. Finally, PSCAD/EMTDC simulations are carried out to verify the proposed method, and dynamic model experiments are conducted to validate its engineering feasibility. The results show that the proposed element correctly identifies the fault direction under both three-phase and phase-to-phase fault conditions. Additional tests considering measurement noise and opposite-side grid-strength variation further demonstrate the robustness of the proposed criterion. Compared with conventional directional elements, the proposed method improves the adaptability of non-ground fault-direction identification in IBR-connected AC lines.
- 24 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72  (12) , 14116-14127
Flexible Voltage Arc Suppression in Distribution Networks Considering Asymmetric Ground Parameters Based on Power Router
Asymmetric ground parameters (AGPs) of the distribution system impact fault handling, not only causing false triggers potentially, but also leading to arc extinction failures of traditional arc suppression methods. Therefore, this article analyzes the characteristics of the AGPs distribution network integrated with power router (PR) in depth. And an effective resistance-capacitance impedance midpoint grounding is innovatively designed on dc side of PR, without changing the grid grounding mode by control. Thus, novel methods of PR-based active parameters asymmetry identification (APAI), and single line-to-ground (SLG) faults flexible voltage arc suppression (FVAS) considering AGPs, are proposed under the VdcQ-0, which ensures the zero-sequence decoupling regulation. First, AGPs characteristics are actively detected by interfrequency signal injection (IFSI) via PR, and APAI is initiated to identify the primary cause of the asymmetry by interfrequency damping ratio. Then, if judged as an SLG fault, PR-based FVAS is employed to actively reduce the fault voltage below re-arcing threshold, the compensation mechanism considers AGPs. Finally, simulation and experiment results demonstrate the validity of the proposed 0-axis control under VdcQ-0, verify the feasibility and effectiveness of PR-based APAI and FVAS.
- 24 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72  (12) , 14116-14127
Flexible Voltage Arc Suppression in Distribution Networks Considering Asymmetric Ground Parameters Based on Power Router
Asymmetric ground parameters (AGPs) of the distribution system impact fault handling, not only causing false triggers potentially, but also leading to arc extinction failures of traditional arc suppression methods. Therefore, this article analyzes the characteristics of the AGPs distribution network integrated with power router (PR) in depth. And an effective resistance-capacitance impedance midpoint grounding is innovatively designed on dc side of PR, without changing the grid grounding mode by control. Thus, novel methods of PR-based active parameters asymmetry identification (APAI), and single line-to-ground (SLG) faults flexible voltage arc suppression (FVAS) considering AGPs, are proposed under the VdcQ-0, which ensures the zero-sequence decoupling regulation. First, AGPs characteristics are actively detected by interfrequency signal injection (IFSI) via PR, and APAI is initiated to identify the primary cause of the asymmetry by interfrequency damping ratio. Then, if judged as an SLG fault, PR-based FVAS is employed to actively reduce the fault voltage below re-arcing threshold, the compensation mechanism considers AGPs. Finally, simulation and experiment results demonstrate the validity of the proposed 0-axis control under VdcQ-0, verify the feasibility and effectiveness of PR-based APAI and FVAS.
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40  (1) , 237-248
Fault Property Identification and Fault Recovery Scheme for Flexible DC Lines Based on Voltage Injection
In overhead line MMC-HVDC systems, hybrid modular multilevel converters (MMC) can limit fault currents by reducing the voltage during DC faults. For successful system recovery after fault isolation, it is critical to accurately identify the fault characteristics. However, blindly restarting the system risks causing further damage within a short time frame, compromising overall system safety. To address these concerns, this paper proposes a fault identification and system restoration scheme tailored for hybrid MMC-HVDC transmission systems. The proposed approach enhances the control of hybrid MMC injection signals, ensuring fault identification while minimizing the risk of damage to converter valves. A thorough analysis of system responses under various fault conditions is conducted. Additionally, a criterion is established using the Euclidean distance between the voltage reference value and voltage measured value to distinguish fault property. Strategies for voltage restoration and power recovery in the event of temporary faults are also presented, significantly reducing recovery time. The effectiveness of the proposed scheme is validated through simulation results under various fault conditions.
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40  (1) , 237-248
Fault Property Identification and Fault Recovery Scheme for Flexible DC Lines Based on Voltage Injection
In overhead line MMC-HVDC systems, hybrid modular multilevel converters (MMC) can limit fault currents by reducing the voltage during DC faults. For successful system recovery after fault isolation, it is critical to accurately identify the fault characteristics. However, blindly restarting the system risks causing further damage within a short time frame, compromising overall system safety. To address these concerns, this paper proposes a fault identification and system restoration scheme tailored for hybrid MMC-HVDC transmission systems. The proposed approach enhances the control of hybrid MMC injection signals, ensuring fault identification while minimizing the risk of damage to converter valves. A thorough analysis of system responses under various fault conditions is conducted. Additionally, a criterion is established using the Euclidean distance between the voltage reference value and voltage measured value to distinguish fault property. Strategies for voltage restoration and power recovery in the event of temporary faults are also presented, significantly reducing recovery time. The effectiveness of the proposed scheme is validated through simulation results under various fault conditions.
- Open Access
- 17 August 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 161
A single-ended high-impedance fault protection scheme for hybrid HVDC transmission lines based on coordination of control objective
- 17 August 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 161
Open AccessA single-ended high-impedance fault protection scheme for hybrid HVDC transmission lines based on coordination of control objective
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39  (3) , 1816-1826
A Novel Pilot Protection Scheme Based on Differential Voltage for Hybrid LCC/MMC HVDC Transmission Lines
The wide application of hybrid LCC/MMC HVDC system will be a trend in the future, and the performance of DC overhead line protection directly affects the safety of the system. The differential protection is used as backup protection to deal with high fault resistance conditions. However, it needs a long time delay to avoid mal-operation because of the distributed capacitance current. A new pilot protection scheme based on differential voltage is proposed in this paper to enhance the backup protection performance. In the proposed scheme, the compensated voltages at the setting points will be obtained from the measured voltage and current of the relay devices. The differential voltage at a setting point on the line is defined as the difference between the compensated voltages obtained by the rectifier-side relay devices and the inverter-side relay devices. The differential voltages are very tiny in external fault scenarios. Nevertheless, the differential voltages are large in internal fault scenarios. To improve the sensitivity and enhance protection performance, two setting points are set on the line. To simplify the calculation and ensure the calculation accuracy, the measured voltage and current are band-pass filtered. The proposed method has fast operation speed, simple calculation process, and can accurately estimate the fault distance. A ±800 kV hybrid LCC/MMC HVDC system is modelled in PSCAD/EMTDC to test the performance of the proposed scheme, and the effectiveness and reliability of it is verified.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39  (3) , 1816-1826
A Novel Pilot Protection Scheme Based on Differential Voltage for Hybrid LCC/MMC HVDC Transmission Lines
The wide application of hybrid LCC/MMC HVDC system will be a trend in the future, and the performance of DC overhead line protection directly affects the safety of the system. The differential protection is used as backup protection to deal with high fault resistance conditions. However, it needs a long time delay to avoid mal-operation because of the distributed capacitance current. A new pilot protection scheme based on differential voltage is proposed in this paper to enhance the backup protection performance. In the proposed scheme, the compensated voltages at the setting points will be obtained from the measured voltage and current of the relay devices. The differential voltage at a setting point on the line is defined as the difference between the compensated voltages obtained by the rectifier-side relay devices and the inverter-side relay devices. The differential voltages are very tiny in external fault scenarios. Nevertheless, the differential voltages are large in internal fault scenarios. To improve the sensitivity and enhance protection performance, two setting points are set on the line. To simplify the calculation and ensure the calculation accuracy, the measured voltage and current are band-pass filtered. The proposed method has fast operation speed, simple calculation process, and can accurately estimate the fault distance. A ±800 kV hybrid LCC/MMC HVDC system is modelled in PSCAD/EMTDC to test the performance of the proposed scheme, and the effectiveness and reliability of it is verified.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38  (3) , 2110-2118
A Novel Markov Model for Protective Relay Reliability
Microprocessor-based protective relay has risen to the ‘technology of choice’ with regard to power system protection due to its monitoring capability, self-checking capability, event recording capability, communication capability, capability for remote interrogation and setting application, and multiple setting groups. However, the existing Markov reliability model for protective relays does not reflect the state of the art of microprocessor-based relays. And the complexity of the Markov model limits its application in the wide range of relay studies. Therefore, this article establishes the general state-transition diagrams of protected components and relays, and a novel Markov model of a protection/component system by taking account of monitoring, self-checking, routine tests, common-cause failures, human error, operation of back-up protection, relay failure to operations and relay mal-trips. The study results of the sensitivity analysis and comparison analysis demonstrate the rationality and superiority of the novel model.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38  (3) , 2110-2118
A Novel Markov Model for Protective Relay Reliability
Microprocessor-based protective relay has risen to the ‘technology of choice’ with regard to power system protection due to its monitoring capability, self-checking capability, event recording capability, communication capability, capability for remote interrogation and setting application, and multiple setting groups. However, the existing Markov reliability model for protective relays does not reflect the state of the art of microprocessor-based relays. And the complexity of the Markov model limits its application in the wide range of relay studies. Therefore, this article establishes the general state-transition diagrams of protected components and relays, and a novel Markov model of a protection/component system by taking account of monitoring, self-checking, routine tests, common-cause failures, human error, operation of back-up protection, relay failure to operations and relay mal-trips. The study results of the sensitivity analysis and comparison analysis demonstrate the rationality and superiority of the novel model.
- 1 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1783-1789
Simpson’s Rule Differential Protection for New Energy Power Plant Outgoing Line
New energy power supplies are connected to the grid through converters, and the fault features of short-circuit currents include small current amplitudes, power frequency variations, and phase limitations, which may reduce sensitivity of traditional differential protection, and even cause uncorrected operation. This phenomenon is particularly prominent in new energy power plants outgoing lines. Therefore, this article firstly discussed the fault feature of new energy sources. Then a theory of current differential protection based on Simpson’s Rule integration is put forward, which can reliably identify the internal or external faults. Finally, build the relevant simulation model to prove the performance of Simpson’s Rule differential protection scheme for new energy power plant outgoing line. The simulation results have suggested that the protection scheme fully satisfies the demands of safe operation of energy power plant.
- 1 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1783-1789
Simpson’s Rule Differential Protection for New Energy Power Plant Outgoing Line
New energy power supplies are connected to the grid through converters, and the fault features of short-circuit currents include small current amplitudes, power frequency variations, and phase limitations, which may reduce sensitivity of traditional differential protection, and even cause uncorrected operation. This phenomenon is particularly prominent in new energy power plants outgoing lines. Therefore, this article firstly discussed the fault feature of new energy sources. Then a theory of current differential protection based on Simpson’s Rule integration is put forward, which can reliably identify the internal or external faults. Finally, build the relevant simulation model to prove the performance of Simpson’s Rule differential protection scheme for new energy power plant outgoing line. The simulation results have suggested that the protection scheme fully satisfies the demands of safe operation of energy power plant.
- Open Access
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2247  (1) , 012023
A Novel Protection Scheme for Outgoing Line Fault of AC Transmission Line near the Inverter Station of AC/DC Hybrid Power Grid based on AC Filter Characteristics
Compared with traditional AC power grid, the fault characteristics of the AC/DC hybrid power grid are more complex and variable. Hence there is a problem of incorrect action for the fault detection elements used in traditional AC power grid which comes up when an outgoing line fault occurs on the AC transmission line in the vicinity of the inverter station. To distinguish the fault direction under the aforementioned situation, a directional protection scheme based on the characteristics of the AC filter is proposed in this paper. Considering the information can be measured by AC line relay, a method for estimating the current provided by the AC filter is given during an outgoing line fault. According to the difference of current characteristics between forward and reverse fault, the fault direction can be judged based on waveform similarity among the currents provided by the AC filter and measured by the AC line relay. Finally, a simulation model is built on the PSCAD/EMTDC platform for extensive performance evaluation. The reliability and effectiveness of the protection scheme are verified under different cases.
- 1 April 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2247  (1) , 012023
Open AccessA Novel Protection Scheme for Outgoing Line Fault of AC Transmission Line near the Inverter Station of AC/DC Hybrid Power Grid based on AC Filter Characteristics
Compared with traditional AC power grid, the fault characteristics of the AC/DC hybrid power grid are more complex and variable. Hence there is a problem of incorrect action for the fault detection elements used in traditional AC power grid which comes up when an outgoing line fault occurs on the AC transmission line in the vicinity of the inverter station. To distinguish the fault direction under the aforementioned situation, a directional protection scheme based on the characteristics of the AC filter is proposed in this paper. Considering the information can be measured by AC line relay, a method for estimating the current provided by the AC filter is given during an outgoing line fault. According to the difference of current characteristics between forward and reverse fault, the fault direction can be judged based on waveform similarity among the currents provided by the AC filter and measured by the AC line relay. Finally, a simulation model is built on the PSCAD/EMTDC platform for extensive performance evaluation. The reliability and effectiveness of the protection scheme are verified under different cases.
- 4 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37  (4) , 3200-3212
An Incremental Quantities Distance Protection Using Park's Transformation
In this article, an incremental quantities distance protection using Park's transformation is proposed to increase the operation speed of distance protection. Based on the instantaneous voltage in abc frame approximate linear distribution along the AC transmission lines, this article proves that instantaneous voltage in dq frame still satisfies the approximate linear distribution along the AC transmission line. Then, the d -axis voltage components of fault point and setting point are used to determine the internal and external faults. In order to ensure that the presented distance protection can be applied to all fault types, a virtual three-phase system construction method is also presented. The fault point voltage construction method and low-pass filter design method are also discussed. Finally, a typical AC transmission system is developed in PSCAD/EMTDC to verify the performance of the proposed distance protection under different fault conditions. Simulation results indicate that the proposed incremental quantities distance protection has fast operation speed under internal metallic fault conditions and high security under external fault conditions.
- 4 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37  (4) , 3200-3212
An Incremental Quantities Distance Protection Using Park's Transformation
In this article, an incremental quantities distance protection using Park's transformation is proposed to increase the operation speed of distance protection. Based on the instantaneous voltage in abc frame approximate linear distribution along the AC transmission lines, this article proves that instantaneous voltage in dq frame still satisfies the approximate linear distribution along the AC transmission line. Then, the d -axis voltage components of fault point and setting point are used to determine the internal and external faults. In order to ensure that the presented distance protection can be applied to all fault types, a virtual three-phase system construction method is also presented. The fault point voltage construction method and low-pass filter design method are also discussed. Finally, a typical AC transmission system is developed in PSCAD/EMTDC to verify the performance of the proposed distance protection under different fault conditions. Simulation results indicate that the proposed incremental quantities distance protection has fast operation speed under internal metallic fault conditions and high security under external fault conditions.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37  (3) , 1549-1558
An Improved Fast Distance Relay to Mitigate the Impacts of Rogowski Coil Transducer Transient
The Rogowski coil transducer's integrator will amplify the transmission error, which may lead to mal-operation of the relay. In this paper, a novel method of line relay based on the differential output of Rogowski coil is proposed. Besides, an improved fast distance relay based on the differential output of Rogowski coil is presented. Based on the equal transfer process of transmission lines(ETPTL), the voltage signal should be processed by the virtual Rogowski coil to solve the inconsistent transfer problem between voltage and current. Furthermore, this paper also presents the reconstruction method of voltage at the fault point and the least-square algorithm to solve the R-L differential equation, so as to improve the algorithm accuracy. Furthermore, the equal transfer process error of the virtual Rogowski coil is analyzed in the paper, and the design principle of low pass filter is also proposed. Simulation results and experiment results demonstrate that the improved fast distance relay scheme has high operation speed, which is signed prior to other distance relay schemes. The proposed method also provides a valuable reference for other types of transmission line relay based on Rogowski coil transducer.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37  (3) , 1549-1558
An Improved Fast Distance Relay to Mitigate the Impacts of Rogowski Coil Transducer Transient
The Rogowski coil transducer's integrator will amplify the transmission error, which may lead to mal-operation of the relay. In this paper, a novel method of line relay based on the differential output of Rogowski coil is proposed. Besides, an improved fast distance relay based on the differential output of Rogowski coil is presented. Based on the equal transfer process of transmission lines(ETPTL), the voltage signal should be processed by the virtual Rogowski coil to solve the inconsistent transfer problem between voltage and current. Furthermore, this paper also presents the reconstruction method of voltage at the fault point and the least-square algorithm to solve the R-L differential equation, so as to improve the algorithm accuracy. Furthermore, the equal transfer process error of the virtual Rogowski coil is analyzed in the paper, and the design principle of low pass filter is also proposed. Simulation results and experiment results demonstrate that the improved fast distance relay scheme has high operation speed, which is signed prior to other distance relay schemes. The proposed method also provides a valuable reference for other types of transmission line relay based on Rogowski coil transducer.