Edward J. Waller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Edward J. Waller has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Ben C. Shirley
CytoGnomix Inc.
2 shared publications David Cole
University of Ontario Institute of Technology, School of Energy Systems and Nuclear Science, 2000 Simcoe Street North, Oshawa, Ontario, L1H 7K4; † Science Applications International Corporation (SAIC Canada), 60 Queen Street, Suite 1516, Ottawa, Ontario, K1P 5Y7
2 shared publications- Eliseos J. Mucaki
Department of Biochemistry, Western University, 1151 Richmond St., London, N6A 3K7, Ontario, Canada
2 shared publications - Joan H. M. Knoll
University of Western Ontario
2 shared publications - Peter K. Rogan
Dept of Biochemistry Siebens-Drake, Room 201A, Schulich School of Medicine and Dentistry, University of Western Ontario, Canada
2 shared publications - Scott B. Nokleby
Mechatronic and Robotic Systems Laboratory, University of Ontario Institute of Technology, Oshawa, ON L1H 7K4, Canada
2 shared publications
Latest Publications
- 8 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Games
- Vol. 14 (3) , 502-510
Seeing the Invisible: A VR Approach to Radiation Attenuation Visualization for Nuclear Engineering Laboratory Practices
The principle of “As Low As Reasonably Achievable” or ALARA is taught through laboratory practices composed of lectures and simulations to maintain the radiation exposure at a minimum. Hands-on practices are limited due to the health risks associated with radioactive exposure, leading to the development of virtual, augmented, and mixed reality simulations that pose no harm to trainees. This article presents the development of a virtual reality (VR) model for attenuating radiation visualization during runtime, employing numerical simulation with VR. Our attenuation model responds dynamically to the environment and does not rely on precalculated radiation fields as other works in the literature. Our approach also includes game elements to enhance the laboratory experience. Our goal is to understand the effects of the virtual environments on usability, engagement, completion time, and radiation dose exposure. Preliminary results indicate that the gamified version was found more engaging as participants felt more competent, less frustrated, and more immersed; it was also perceived as more usable with a SUS score of 81.87/100 in comparison to the nongamified with a SUS score of 58.12/100. Participants were faster when completing the nongamified version with an average of 103.28 ± SD 41.26 s in comparison to 175.31 ± SD 91.16 s with the gamified version. Finally, participants received 2.11 mSv less dose exposure with the nongamified version. We believe that practicing the ALARA principle in VR can offer insights on how trainees approach and work around radiation sources, as not necessarily the faster completion results in less exposure.
- 8 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Games
- Vol. 14 (3) , 502-510
Seeing the Invisible: A VR Approach to Radiation Attenuation Visualization for Nuclear Engineering Laboratory Practices
The principle of “As Low As Reasonably Achievable” or ALARA is taught through laboratory practices composed of lectures and simulations to maintain the radiation exposure at a minimum. Hands-on practices are limited due to the health risks associated with radioactive exposure, leading to the development of virtual, augmented, and mixed reality simulations that pose no harm to trainees. This article presents the development of a virtual reality (VR) model for attenuating radiation visualization during runtime, employing numerical simulation with VR. Our attenuation model responds dynamically to the environment and does not rely on precalculated radiation fields as other works in the literature. Our approach also includes game elements to enhance the laboratory experience. Our goal is to understand the effects of the virtual environments on usability, engagement, completion time, and radiation dose exposure. Preliminary results indicate that the gamified version was found more engaging as participants felt more competent, less frustrated, and more immersed; it was also perceived as more usable with a SUS score of 81.87/100 in comparison to the nongamified with a SUS score of 58.12/100. Participants were faster when completing the nongamified version with an average of 103.28 ± SD 41.26 s in comparison to 175.31 ± SD 91.16 s with the gamified version. Finally, participants received 2.11 mSv less dose exposure with the nongamified version. We believe that practicing the ALARA principle in VR can offer insights on how trainees approach and work around radiation sources, as not necessarily the faster completion results in less exposure.
- Open Access
Automated Cytogenetic Biodosimetry at Population-Scale
The dicentric chromosome (DC) assay accurately quantifies exposure to radiation; however, manual and semi-automated assignment of DCs has limited its use for a potential large-scale radiation incident. The Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates unattended DC detection and determines radiation exposures, fulfilling IAEA criteria for triage biodosimetry. This study evaluates the throughput of high-performance ADCI (ADCI-HT) to stratify exposures of populations in 15 simulated population scale radiation exposures. ADCI-HT streamlines dose estimation using a supercomputer by optimal hierarchical scheduling of DC detection for varying numbers of samples and metaphase cell images in parallel on multiple processors. We evaluated processing times and accuracy of estimated exposures across census-defined populations. Image processing of 1744 samples on 16,384 CPUs required 1 h 11 min 23 s and radiation dose estimation based on DC frequencies required 32 sec. Processing of 40,000 samples at 10 exposures from five laboratories required 25 h and met IAEA criteria (dose estimates were within 0.5 Gy; median = 0.07). Geostatistically interpolated radiation exposure contours of simulated nuclear incidents were defined by samples exposed to clinically relevant exposure levels (1 and 2 Gy). Analysis of all exposed individuals with ADCI-HT required 0.6–7.4 days, depending on the population density of the simulation.
Open AccessAutomated Cytogenetic Biodosimetry at Population-Scale
The dicentric chromosome (DC) assay accurately quantifies exposure to radiation; however, manual and semi-automated assignment of DCs has limited its use for a potential large-scale radiation incident. The Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates unattended DC detection and determines radiation exposures, fulfilling IAEA criteria for triage biodosimetry. This study evaluates the throughput of high-performance ADCI (ADCI-HT) to stratify exposures of populations in 15 simulated population scale radiation exposures. ADCI-HT streamlines dose estimation using a supercomputer by optimal hierarchical scheduling of DC detection for varying numbers of samples and metaphase cell images in parallel on multiple processors. We evaluated processing times and accuracy of estimated exposures across census-defined populations. Image processing of 1744 samples on 16,384 CPUs required 1 h 11 min 23 s and radiation dose estimation based on DC frequencies required 32 sec. Processing of 40,000 samples at 10 exposures from five laboratories required 25 h and met IAEA criteria (dose estimates were within 0.5 Gy; median = 0.07). Geostatistically interpolated radiation exposure contours of simulated nuclear incidents were defined by samples exposed to clinically relevant exposure levels (1 and 2 Gy). Analysis of all exposed individuals with ADCI-HT required 0.6–7.4 days, depending on the population density of the simulation.
- Open Access
Meeting radiation dosimetry capacity requirements of population-scale exposures by geostatistical sampling
Background: Accurate radiation dose estimates are critical for determining eligibility for therapies by timely triaging of exposed individuals after large-scale radiation events. However, the universal assessment of a large population subjected to a nuclear spill incident or detonation is not feasible. Even with high-throughput dosimetry analysis, test volumes far exceed the capacities of first responders to measure radiation exposures directly, or to acquire and process samples for follow-on biodosimetry testing. Aim: To significantly reduce data acquisition and processing requirements for triaging of treatment-eligible exposures in population-scale radiation incidents. Methods: Physical radiation plumes modelled nuclear detonation scenarios of simulated exposures at 22 US locations. Models assumed only location of the epicenter and historical, prevailing wind directions/speeds. The spatial boundaries of graduated radiation exposures were determined by targeted, multistep geostatistical analysis of small population samples. Initially, locations proximate to these sites were randomly sampled (generally 0.1% of population). Empirical Bayesian kriging established radiation dose contour levels circumscribing these sites. Densification of each plume identified critical locations for additional sampling. After repeated kriging and densification, overlapping grids between each pair of contours of successive plumes were compared based on their diagonal Bray-Curtis distances and root-mean-square deviations, which provided criteria (<10% difference) to discontinue sampling. Results/Conclusions: We modeled 30 scenarios, including 22 urban/high-density and 2 rural/low-density scenarios under various weather conditions. Multiple (3-10) rounds of sampling and kriging were required for the dosimetry maps to converge, requiring between 58 and 347 samples for different scenarios. On average, 70±10% of locations where populations are expected to receive an exposure ≥2Gy were identified. Under sub-optimal sampling conditions, the number of iterations and samples were increased and accuracy was reduced. Geostatistical mapping limits the number of required dose assessments, the time required, and radiation exposure to first responders. Geostatistical analysis will expedite triaging of acute radiation exposure in population-scale nuclear events.
Open AccessMeeting radiation dosimetry capacity requirements of population-scale exposures by geostatistical sampling
Background: Accurate radiation dose estimates are critical for determining eligibility for therapies by timely triaging of exposed individuals after large-scale radiation events. However, the universal assessment of a large population subjected to a nuclear spill incident or detonation is not feasible. Even with high-throughput dosimetry analysis, test volumes far exceed the capacities of first responders to measure radiation exposures directly, or to acquire and process samples for follow-on biodosimetry testing. Aim: To significantly reduce data acquisition and processing requirements for triaging of treatment-eligible exposures in population-scale radiation incidents. Methods: Physical radiation plumes modelled nuclear detonation scenarios of simulated exposures at 22 US locations. Models assumed only location of the epicenter and historical, prevailing wind directions/speeds. The spatial boundaries of graduated radiation exposures were determined by targeted, multistep geostatistical analysis of small population samples. Initially, locations proximate to these sites were randomly sampled (generally 0.1% of population). Empirical Bayesian kriging established radiation dose contour levels circumscribing these sites. Densification of each plume identified critical locations for additional sampling. After repeated kriging and densification, overlapping grids between each pair of contours of successive plumes were compared based on their diagonal Bray-Curtis distances and root-mean-square deviations, which provided criteria (<10% difference) to discontinue sampling. Results/Conclusions: We modeled 30 scenarios, including 22 urban/high-density and 2 rural/low-density scenarios under various weather conditions. Multiple (3-10) rounds of sampling and kriging were required for the dosimetry maps to converge, requiring between 58 and 347 samples for different scenarios. On average, 70±10% of locations where populations are expected to receive an exposure ≥2Gy were identified. Under sub-optimal sampling conditions, the number of iterations and samples were increased and accuracy was reduced. Geostatistical mapping limits the number of required dose assessments, the time required, and radiation exposure to first responders. Geostatistical analysis will expedite triaging of acute radiation exposure in population-scale nuclear events.
- 1 January 2020
- Published by Springer Nature
- p. 1-72
Radiation in the Environment, Sources of
- 15 March 2019
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 5 (2)
Technical Communication During Nuclear and Radiological Emergencies With the Tools to Support International Assessment and Prognosis
The International Atomic Energy Agency's (IAEA) Incident and Emergency Centre (IEC) has custom designed software tools to support assessment and prognosis of nuclear and radiological emergency scenarios, aimed at ensuring consistent and concise technical reports for emergency assessments. In this paper the functionality, updating and structural development of emergency communications tools is presented, that lead the user through a series of questions with the aid of instructions that will collect relevant technical details and organize them into standardized reports. These reports can be exported for use in internal communication or communication with external stakeholders. This paper discusses enhancements in the suite of tools, specifically the reactor assessment tool (RAT), which was updated, the emergency response action, and the radiological source assessment tools, which were expanded and finally the development of two dose assessment tools (DAT) for internal and external exposure to radioactive substances.
- 15 March 2019
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 5 (2)
Technical Communication During Nuclear and Radiological Emergencies With the Tools to Support International Assessment and Prognosis
The International Atomic Energy Agency's (IAEA) Incident and Emergency Centre (IEC) has custom designed software tools to support assessment and prognosis of nuclear and radiological emergency scenarios, aimed at ensuring consistent and concise technical reports for emergency assessments. In this paper the functionality, updating and structural development of emergency communications tools is presented, that lead the user through a series of questions with the aid of instructions that will collect relevant technical details and organize them into standardized reports. These reports can be exported for use in internal communication or communication with external stakeholders. This paper discusses enhancements in the suite of tools, specifically the reactor assessment tool (RAT), which was updated, the emergency response action, and the radiological source assessment tools, which were expanded and finally the development of two dose assessment tools (DAT) for internal and external exposure to radioactive substances.
- 5 March 2018
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 4 (2)
Probabilistic-Based Robotic Radiation Mapping Using Sparse Data
This paper presents a novel methodology for generating radiation intensity maps using a mobile robotic platform and an integrated radiation model. The radiation intensity mapping approach consists of two stages. First, radiation intensity samples are collected using a radiation sensor mounted on a mobile robotic platform, reducing the risk of exposure to humans from an unknown radiation field. Next, these samples, which need only to be taken from a subsection of the entire area being mapped, are then used to calibrate a radiation model of the area. This model is then used to predict the radiation intensity field throughout the rest of the area that could not be directly measured. The performance of the approach is evaluated through experiments. The results show that the developed system is effective at achieving the goal of generating radiation maps using sparse data.
- 5 March 2018
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 4 (2)
Probabilistic-Based Robotic Radiation Mapping Using Sparse Data
This paper presents a novel methodology for generating radiation intensity maps using a mobile robotic platform and an integrated radiation model. The radiation intensity mapping approach consists of two stages. First, radiation intensity samples are collected using a radiation sensor mounted on a mobile robotic platform, reducing the risk of exposure to humans from an unknown radiation field. Next, these samples, which need only to be taken from a subsection of the entire area being mapped, are then used to calibrate a radiation model of the area. This model is then used to predict the radiation intensity field throughout the rest of the area that could not be directly measured. The performance of the approach is evaluated through experiments. The results show that the developed system is effective at achieving the goal of generating radiation maps using sparse data.
- 25 May 2017
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 3 (3) , 034502
MCNP Simulation of In-Core Dose Rates for an Offline CANDU® Reactor
Inspections of pressure tubes in CANDU® reactors are a key part of maintaining safe operating conditions. The current inspection system, the channel inspection and gauging apparatus for reactors (CIGAR), performs the job well but is limited by the fact that it can only inspect one channel at a time. A multidisciplinary team is currently developing a novel robotic inspection system. As part of this work, a Monte Carlo N-particle (MCNP) model has been developed in order to predict the dose rates that the improved inspection system will be exposed to and, from this, predict the component lifetime. This MCNP model will be capable of predicting in-core dose rates at any location within the reactor, and as such could be used for other situations where the in-core dose rate needs to be known. Based on estimates from this model, it is expected that at 7 days after shutdown, the improved inspection system could survive in core for approximately 7 h, providing it uses a tungsten shield 2.5 cm in thickness around the integrated circuit components. This is expected to be sufficient to perform a single inspection.
- 25 May 2017
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 3 (3) , 034502
MCNP Simulation of In-Core Dose Rates for an Offline CANDU® Reactor
Inspections of pressure tubes in CANDU® reactors are a key part of maintaining safe operating conditions. The current inspection system, the channel inspection and gauging apparatus for reactors (CIGAR), performs the job well but is limited by the fact that it can only inspect one channel at a time. A multidisciplinary team is currently developing a novel robotic inspection system. As part of this work, a Monte Carlo N-particle (MCNP) model has been developed in order to predict the dose rates that the improved inspection system will be exposed to and, from this, predict the component lifetime. This MCNP model will be capable of predicting in-core dose rates at any location within the reactor, and as such could be used for other situations where the in-core dose rate needs to be known. Based on estimates from this model, it is expected that at 7 days after shutdown, the improved inspection system could survive in core for approximately 7 h, providing it uses a tungsten shield 2.5 cm in thickness around the integrated circuit components. This is expected to be sufficient to perform a single inspection.
- 1 August 2015
- Published by Wolters Kluwer Health in Health Physics
- Vol. 109 (2) , S176-S185
Operational Testing of a Combined Hardware-Software Strategy for Triage of Radiologically-Contaminated Persons
After a radiological dispersal device (RDD) event, it is possible for radionuclides to enter the human body through inhalation, ingestion, and skin and wound absorption. The dominant pathway will be through inhalation. From a health physics perspective, it is important to know the magnitude of the intake to perform dosimetric assessments. From a medical perspective, removal of radionuclides leading to dose (hence risk) aversion is of high importance. The efficacy of medical decorporation strategies is extremely dependent upon the time of treatment delivery after intake. The “golden hour,” or more realistically 3–4 h, is imperative when attempting to increase removal of radionuclides from extracellular fluids prior to cellular incorporation. To assist medical first response personnel in making timely decisions regarding appropriate treatment delivery modes, a software tool has been developed which compiles existing radionuclide decorporation therapy data and allows a user to perform simple triage leading to potential appropriate decorporation treatment strategies. Three triage algorithms were included: (1) multi-parameter model (MPM), (2) clinical decision guidance (CDG) model, and (3) annual limit on intake (ALI) model. A radiation triage mask (RTM) has simultaneously been developed to provide a simple and rapid hardware solution for first responders to triage internally exposed personnel in the field. The hardware/software strategy was field tested with a military medical unit and was found by end-users to be relatively simple to learn and use.
- 1 August 2015
- Published by Wolters Kluwer Health in Health Physics
- Vol. 109 (2) , S176-S185
Operational Testing of a Combined Hardware-Software Strategy for Triage of Radiologically-Contaminated Persons
After a radiological dispersal device (RDD) event, it is possible for radionuclides to enter the human body through inhalation, ingestion, and skin and wound absorption. The dominant pathway will be through inhalation. From a health physics perspective, it is important to know the magnitude of the intake to perform dosimetric assessments. From a medical perspective, removal of radionuclides leading to dose (hence risk) aversion is of high importance. The efficacy of medical decorporation strategies is extremely dependent upon the time of treatment delivery after intake. The “golden hour,” or more realistically 3–4 h, is imperative when attempting to increase removal of radionuclides from extracellular fluids prior to cellular incorporation. To assist medical first response personnel in making timely decisions regarding appropriate treatment delivery modes, a software tool has been developed which compiles existing radionuclide decorporation therapy data and allows a user to perform simple triage leading to potential appropriate decorporation treatment strategies. Three triage algorithms were included: (1) multi-parameter model (MPM), (2) clinical decision guidance (CDG) model, and (3) annual limit on intake (ALI) model. A radiation triage mask (RTM) has simultaneously been developed to provide a simple and rapid hardware solution for first responders to triage internally exposed personnel in the field. The hardware/software strategy was field tested with a military medical unit and was found by end-users to be relatively simple to learn and use.
- 1 January 2015
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 1 (1) , 011005
Experimental Modeling of Wind-Driven Bin-by-Bin Resuspension Factors of Freshly Fallen Radionuclides After an Energetic Release From a Radiological Dispersal Device
Small-scale experiments were carried out to characterize the resuspension factor of radioactive lanthanum oxide powder in an environmentally controlled wind tunnel, with the majority using particle sizes less than in order to assess the impact of wind resuspension stresses and surface roughness conditions on resuspension. Operational principles of the measuring devices used in the radionuclide resuspension experiments and corresponding uncertainties are discussed. The average bin-by-bin particle resuspension factors () for particle sizes, in the range of and for downwind fallout locations, were calculated and are reported here as and , respectively.- 1 January 2015
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 1 (1) , 011005
Experimental Modeling of Wind-Driven Bin-by-Bin Resuspension Factors of Freshly Fallen Radionuclides After an Energetic Release From a Radiological Dispersal Device
Small-scale experiments were carried out to characterize the resuspension factor of radioactive lanthanum oxide powder in an environmentally controlled wind tunnel, with the majority using particle sizes less than in order to assess the impact of wind resuspension stresses and surface roughness conditions on resuspension. Operational principles of the measuring devices used in the radionuclide resuspension experiments and corresponding uncertainties are discussed. The average bin-by-bin particle resuspension factors () for particle sizes, in the range of and for downwind fallout locations, were calculated and are reported here as and , respectively.- 18 June 2012
- Published by Taylor & Francis in European Journal of Engineering Education
- Vol. 37 (4) , 331-342
Teaching problem-solving skills to nuclear engineering students
Problem solving is an essential skill for nuclear engineering graduates entering the workforce. Training in qualitative and quantitative aspects of problem solving allows students to conceptualise and execute solutions to complex problems. Solutions to problems in high consequence fields of study such as nuclear engineering require rapid and accurate analysis of the problems, design of solutions (focusing on public safety, environmental stewardship and ethics), solution execution and monitoring results. A three-month course in problem solving, modelling and simulation was designed and a collaborative approach was undertaken with instructors from both industry and academia. Training was optimised for the laptop-based pedagogy, which provided unique advantages for a course that includes modelling and simulation components. The concepts and tools learned as part of the training were observed to be utilised throughout the duration of student university studies and interviews with students who have entered the workforce indicate that the approaches learned and practised are retained long term.
- 18 June 2012
- Published by Taylor & Francis in European Journal of Engineering Education
- Vol. 37 (4) , 331-342
Teaching problem-solving skills to nuclear engineering students
Problem solving is an essential skill for nuclear engineering graduates entering the workforce. Training in qualitative and quantitative aspects of problem solving allows students to conceptualise and execute solutions to complex problems. Solutions to problems in high consequence fields of study such as nuclear engineering require rapid and accurate analysis of the problems, design of solutions (focusing on public safety, environmental stewardship and ethics), solution execution and monitoring results. A three-month course in problem solving, modelling and simulation was designed and a collaborative approach was undertaken with instructors from both industry and academia. Training was optimised for the laptop-based pedagogy, which provided unique advantages for a course that includes modelling and simulation components. The concepts and tools learned as part of the training were observed to be utilised throughout the duration of student university studies and interviews with students who have entered the workforce indicate that the approaches learned and practised are retained long term.