Boyu Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Boyu Peng has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Sachin Jambawalikar
Department of Radiology, Columbia University, New York, NY 10027, USA
3 shared publications - Andrew J. Einstein
Division of Cardiology, Department of Medicine, and Department of Radiology, Columbia University Irving Medical Center and New York-Presbyterian Hospital (A.J.E.).
2 shared publications - Anjali Chelliah
Division of Pediatric Cardiology, Atlantic Health Morristown Medical Center, Morristown, NJ, USA; Division of Pediatric Cardiology, Columbia University Irving Medical Center, New York, NY, USA
1 shared publication - Benjamin Navot
Department of Radiology, Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center and NewYork-Presbyterian Hospital, New York, United States of America
1 shared publication - Brian T. Collins
Department of Radiation Oncology, University of South Florida Tampa General Hospital, Tampa, FL 33612, USA
1 shared publication - Carla M. Thompson
Imaging Institute, Division of Radiology, Cleveland Clinic, and Lerner Research Institute, Department of Biomedical Engineering, Cleveland Clinic, and Department of Chemical and Biomedical Engineering, Cleveland State University, Cleveland, Ohio
1 shared publication
Latest Publications
- 26 March 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 20 (3) , 279-285
Influence of computed tomography reconstruction algorithms on coronary artery calcium scores and reader agreement
- 26 March 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 20 (3) , 279-285
Influence of computed tomography reconstruction algorithms on coronary artery calcium scores and reader agreement
- Open Access
Chest CT for Breast Cancer Diagnosis
Background: We report the results of our retrospective analysis of the ability of standard chest CT scans to correctly diagnose cancer in the breast. Methods: Four hundred and fifty-three consecutive women with chest CT scans (contrast and non-contrast) preceding mammograms within one year comprise the study population. All chest CT images were reviewed by an experienced fellowship-trained chest radiologist and mammograms by an experienced fellowship-trained mammographer without the benefit of prior or ancillary studies; only four mammographic views were included for analysis. The size, location, and shape of breast masses were documented; on CT, the average Hounsfield units were measured. On both imaging modalities, the presence of lymphadenopathy, architectural distortion, skin thickening, and microcalcifications were recorded. Ultimately, the interpreting radiologist was asked to decide if a biopsy was indicated, and these recommendations were correlated with the patient’s outcome. Findings: Nineteen of four hundred and fifty-three patients had breast cancer at the time of the mammography. Breast masses were the most common finding on chest CT, leading to the recommendation for biopsy. Hounsfield units were the most important feature for discerning benign from malignant masses. CT sensitivity, specificity, and accuracy of CT for breast cancer detection was 84.21%, 99.3%, and 98.68% compared to 78.95%, 93.78%, and 93.16% for four-view mammography. Chest CT scans with or without contrast had similar outcomes for specificity and accuracy, but sensitivity was slightly less without contrast. Chest CT alone, without the benefit of prior exams and patient recall, correctly diagnosed cancer with a p-value of <0.0001 compared to mammography with the same limitations. Conclusion: Chest CT accurately diagnosed breast cancer with few false positives and negatives and did so without the need for patient recall for additional imaging.
Open AccessChest CT for Breast Cancer Diagnosis
Background: We report the results of our retrospective analysis of the ability of standard chest CT scans to correctly diagnose cancer in the breast. Methods: Four hundred and fifty-three consecutive women with chest CT scans (contrast and non-contrast) preceding mammograms within one year comprise the study population. All chest CT images were reviewed by an experienced fellowship-trained chest radiologist and mammograms by an experienced fellowship-trained mammographer without the benefit of prior or ancillary studies; only four mammographic views were included for analysis. The size, location, and shape of breast masses were documented; on CT, the average Hounsfield units were measured. On both imaging modalities, the presence of lymphadenopathy, architectural distortion, skin thickening, and microcalcifications were recorded. Ultimately, the interpreting radiologist was asked to decide if a biopsy was indicated, and these recommendations were correlated with the patient’s outcome. Findings: Nineteen of four hundred and fifty-three patients had breast cancer at the time of the mammography. Breast masses were the most common finding on chest CT, leading to the recommendation for biopsy. Hounsfield units were the most important feature for discerning benign from malignant masses. CT sensitivity, specificity, and accuracy of CT for breast cancer detection was 84.21%, 99.3%, and 98.68% compared to 78.95%, 93.78%, and 93.16% for four-view mammography. Chest CT scans with or without contrast had similar outcomes for specificity and accuracy, but sensitivity was slightly less without contrast. Chest CT alone, without the benefit of prior exams and patient recall, correctly diagnosed cancer with a p-value of <0.0001 compared to mammography with the same limitations. Conclusion: Chest CT accurately diagnosed breast cancer with few false positives and negatives and did so without the need for patient recall for additional imaging.
- 26 April 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (8) , e4739
High‐resolution simulation of B0 field conditions in the human heart from segmented computed tomography images
B0 inhomogeneity leads to imaging artifacts in cardiac magnetic resonance imaging (MRI), in particular dark band artifacts with steady‐state free precession pulse sequences. The limited spatial resolution of MR‐derived in vivo B0 maps and the lack of population data prevent systematic analysis of the problem at hand and the development of optimized B0 shim strategies. We used readily available clinical computed tomography (CT) images to simulate the B0 conditions in the human heart at high spatial resolution. Calculated B0 fields showed consistency with MRI‐based B0 measurements. The B0 maps for both the simulations and in vivo measurements showed local field inhomogeneities in the vicinity of lung tips with dominant Z3 spherical harmonic terms in the field distribution. The presented simulation approach allows for the derivation of B0 field conditions at high spatial resolution from CT images and enables the development of subject‐ and population‐specific B0 shim strategies for the human heart.
- 26 April 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (8) , e4739
High‐resolution simulation of B0 field conditions in the human heart from segmented computed tomography images
B0 inhomogeneity leads to imaging artifacts in cardiac magnetic resonance imaging (MRI), in particular dark band artifacts with steady‐state free precession pulse sequences. The limited spatial resolution of MR‐derived in vivo B0 maps and the lack of population data prevent systematic analysis of the problem at hand and the development of optimized B0 shim strategies. We used readily available clinical computed tomography (CT) images to simulate the B0 conditions in the human heart at high spatial resolution. Calculated B0 fields showed consistency with MRI‐based B0 measurements. The B0 maps for both the simulations and in vivo measurements showed local field inhomogeneities in the vicinity of lung tips with dominant Z3 spherical harmonic terms in the field distribution. The presented simulation approach allows for the derivation of B0 field conditions at high spatial resolution from CT images and enables the development of subject‐ and population‐specific B0 shim strategies for the human heart.
- Top Cited PapersOpen Access
- 1 January 2018
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 11 (1) , 64-74
Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography
- 1 January 2018
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 11 (1) , 64-74
Top Cited PapersOpen AccessCardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography