High‐resolution simulation of B0 field conditions in the human heart from segmented computed tomography images
- 26 April 2022
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (8) , e4739
Abstract
B0 inhomogeneity leads to imaging artifacts in cardiac magnetic resonance imaging (MRI), in particular dark band artifacts with steady‐state free precession pulse sequences. The limited spatial resolution of MR‐derived in vivo B0 maps and the lack of population data prevent systematic analysis of the problem at hand and the development of optimized B0 shim strategies. We used readily available clinical computed tomography (CT) images to simulate the B0 conditions in the human heart at high spatial resolution. Calculated B0 fields showed consistency with MRI‐based B0 measurements. The B0 maps for both the simulations and in vivo measurements showed local field inhomogeneities in the vicinity of lung tips with dominant Z3 spherical harmonic terms in the field distribution. The presented simulation approach allows for the derivation of B0 field conditions at high spatial resolution from CT images and enables the development of subject‐ and population‐specific B0 shim strategies for the human heart.Keywords
Funding Information
- Utbildningsdepartementet (01E1O1504)
This publication has 39 references indexed in Scilit:
- High Spatial Resolution and Temporally Resolved T2* Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility StudyPLOS ONE, 2012
- Magnetic field homogenization of the human prefrontal cortex with a set of localized electrical coilsMagnetic Resonance in Medicine, 2009
- Simulation study of susceptibility gradients leading to focal myocardial signal lossJournal of Magnetic Resonance Imaging, 2008
- Application of a Fourier-based method for rapid calculation of field inhomogeneity due to spatial variation of magnetic susceptibilityConcepts in Magnetic Resonance Part B, 2005
- Perturbation method for magnetic field calculations of nonconductive objectsMagnetic Resonance in Medicine, 2004
- Artifact reduction in true‐FISP imaging of the coronary arteries by adjusting imaging frequencyMagnetic Resonance in Medicine, 2003
- Lung Cancer Screening with CT: Mayo Clinic ExperienceRadiology, 2003
- A fast calculation method for magnetic field inhomogeneity due to an arbitrary distribution of bulk susceptibilityConcepts in Magnetic Resonance Part B, 2003
- Dynamic contrast‐enhanced myocardial perfusion imaging using saturation‐prepared TrueFISPJournal of Magnetic Resonance Imaging, 2002
- Cardiac MRI: Recent progress and continued challengesJournal of Magnetic Resonance Imaging, 2002