Benedito Roberto Dos Santos
Benedito Roberto Dos Santos has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Fabio Romano Lofrano Dotto
Department of Electrical and Computer Engineering, São Carlos School of Engineering, University of São Paulo, São Carlos 13566-590, Brazil
3 shared publications - Pedro Oliveira Conceição Junior
Department of Electrical and Computer Engineering, São Carlos School of Engineering, University of São Paulo, São Carlos 13566-590, Brazil
3 shared publications - Gabriel Augusto David
Department of Electrical and Computer Engineering, São Paulo University, São Carlos 13563120, SP, Brazil
2 shared publications - André Luiz Andreoli
Department of Electrical Engineering, São Paulo State University, Bauru 17033-360, SP, Brazil
1 shared publication - Reinaldo Götz de Oliveira Junior
Federal Institute of Education, Science and Technology of Mato Grosso do Sul (IFMS)
1 shared publication
Latest Publications
- 23 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
New Signal Processing-Based Methodology for Optimal Feature Selection of Corona Discharges Measurement in HVDC Systems
This article presents a new method based on the combination of digital signal processing parameters for the selection of optimal characteristics of corona discharges in HVDC systems, particularly for linearization of the discharge model for applications that require a simplified computational approach. The proposed method implements a new metric from the coefficient of variation, CVSTFT , based on the short-time Fourier transform (STFT) and the Hinkley criterion to measure the spectral variability and determine the corona discharge profile in different situations. An experimental analysis was performed by applying voltages between ± 30kV and ± 100 kV in a conductor, and electrical current signals proportional to the corona effect were collected through a data acquisition system. The results indicated that the application of the new method was successful in quantifying, in a simple way, the percentage of growth of corona discharges as a function of the voltage applied within the range of 40-80 kHz. Moreover, it showed 90 %, 91 %, 92%, 97%, 89%, 92%, and 93% of reliability in calculating the root-mean-square deviation (RMSD) based on approximation by a linear model. The frequency band resulting from this study proved to be favorable to establishing a threshold for the percentage of corona discharge growth according to its profile or condition of application, indicating this information may be useful in the construction of mobile devices with low consumption and computational performance, meeting the demands of Industry 4.0 and the Internet of Things.
- 23 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
New Signal Processing-Based Methodology for Optimal Feature Selection of Corona Discharges Measurement in HVDC Systems
This article presents a new method based on the combination of digital signal processing parameters for the selection of optimal characteristics of corona discharges in HVDC systems, particularly for linearization of the discharge model for applications that require a simplified computational approach. The proposed method implements a new metric from the coefficient of variation, CVSTFT , based on the short-time Fourier transform (STFT) and the Hinkley criterion to measure the spectral variability and determine the corona discharge profile in different situations. An experimental analysis was performed by applying voltages between ± 30kV and ± 100 kV in a conductor, and electrical current signals proportional to the corona effect were collected through a data acquisition system. The results indicated that the application of the new method was successful in quantifying, in a simple way, the percentage of growth of corona discharges as a function of the voltage applied within the range of 40-80 kHz. Moreover, it showed 90 %, 91 %, 92%, 97%, 89%, 92%, and 93% of reliability in calculating the root-mean-square deviation (RMSD) based on approximation by a linear model. The frequency band resulting from this study proved to be favorable to establishing a threshold for the percentage of corona discharge growth according to its profile or condition of application, indicating this information may be useful in the construction of mobile devices with low consumption and computational performance, meeting the demands of Industry 4.0 and the Internet of Things.
- 12 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (2) , 2048-2056
Development of a Portable Corona Current Measuring Device for High Voltage Detection in HVDC Systems
High voltage direct current (HVdc) detection is essential to ensure the suitability and operation of electrical systems, as well as personal safety. Today there are commercial sensing devices equipped with a safety system that emits audible warnings, but they do not indicate voltage and polarity levels. Likewise, although the scientific literature describes various solutions with satisfactory results, very few of these achievements are found in real-world applications. The purpose of this article is to present a technological alternative based on the study and development of a simple and portable electronic device to enable the detection and quantification of high voltage and polarity in HVdc systems. The principle is based on the detection of corona current by means of an aluminum tip held at a distance of about 5 mm from the energized surface through a radial contact rod. The detected electrical current signal is collected and processed through an electronic system. The performance was analyzed by means of corona discharge models and high voltage experimental tests in real-world conditions. The results demonstrated the satisfactory response of the proposed approach in the detection, quantification, and identification of polarity in a ±600 kV HVdc transmission system, with an error varying from 1.79% to 2.72% compared to theoretical values, as well as its ability to withstand the influence of temperature variations between 18 °C to 29 °C, relative humidity between 56% and 78%, and an atmospheric pressure kept constant at 101.6 kPa. The proposed approach contributes to HVdc monitoring and inspection activities, helping to ensure their operation and suitability.
- 12 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (2) , 2048-2056
Development of a Portable Corona Current Measuring Device for High Voltage Detection in HVDC Systems
High voltage direct current (HVdc) detection is essential to ensure the suitability and operation of electrical systems, as well as personal safety. Today there are commercial sensing devices equipped with a safety system that emits audible warnings, but they do not indicate voltage and polarity levels. Likewise, although the scientific literature describes various solutions with satisfactory results, very few of these achievements are found in real-world applications. The purpose of this article is to present a technological alternative based on the study and development of a simple and portable electronic device to enable the detection and quantification of high voltage and polarity in HVdc systems. The principle is based on the detection of corona current by means of an aluminum tip held at a distance of about 5 mm from the energized surface through a radial contact rod. The detected electrical current signal is collected and processed through an electronic system. The performance was analyzed by means of corona discharge models and high voltage experimental tests in real-world conditions. The results demonstrated the satisfactory response of the proposed approach in the detection, quantification, and identification of polarity in a ±600 kV HVdc transmission system, with an error varying from 1.79% to 2.72% compared to theoretical values, as well as its ability to withstand the influence of temperature variations between 18 °C to 29 °C, relative humidity between 56% and 78%, and an atmospheric pressure kept constant at 101.6 kPa. The proposed approach contributes to HVdc monitoring and inspection activities, helping to ensure their operation and suitability.
- Open Access
- 1 November 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 10 (1) , 28
A Feasibility Study of the Application of Signal Processing Techniques to Corona Discharge Characterization on HVDC Systems
This paper presents an initial and feasibility study of corona discharge characterization on HVDC systems using an alternative strategy based on digital signal processing techniques. In the corona discharge test, high voltages varying from ±30 to ±80 kV were applied through a DC high-voltage generator. In addition, corona discharges around the conductor were measured by means of a data acquisition prototype system equipped with a metal electrode device for the purpose of corona current measurement. The signals collected were subjected to digital signal processing parameters to extract the most relevant information related to corona discharge occurrence in specific frequency bands. The results reveal that the proposed method was able to detect the corona discharge characteristics following the changes in the signal content, especially, for narrow frequency ranges. The results indicate the feasibility of the proposed method to detect and characterize the corona discharge in a simple way, which expands the research field in corona discharge characterization in HVDC systems by means of digital signal processing and feature extraction.
- 1 November 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 10 (1) , 28
Open AccessA Feasibility Study of the Application of Signal Processing Techniques to Corona Discharge Characterization on HVDC Systems
This paper presents an initial and feasibility study of corona discharge characterization on HVDC systems using an alternative strategy based on digital signal processing techniques. In the corona discharge test, high voltages varying from ±30 to ±80 kV were applied through a DC high-voltage generator. In addition, corona discharges around the conductor were measured by means of a data acquisition prototype system equipped with a metal electrode device for the purpose of corona current measurement. The signals collected were subjected to digital signal processing parameters to extract the most relevant information related to corona discharge occurrence in specific frequency bands. The results reveal that the proposed method was able to detect the corona discharge characteristics following the changes in the signal content, especially, for narrow frequency ranges. The results indicate the feasibility of the proposed method to detect and characterize the corona discharge in a simple way, which expands the research field in corona discharge characterization in HVDC systems by means of digital signal processing and feature extraction.