Sooyoon Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sooyoon Shin has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Ritu Kapur
Radboud Univ Nijmegen, Donders Inst Brain Cognit & Behav, Ctr Expertise Parkinson & Movement Disorders, Dept Neurol,Med Ctr, Reinier Postlaan 4, NL-6525 GC Nijmegen, Netherlands
8 shared publications - Nathan Kowahl
Verily Life Sci, South San Francisco, CA USA
6 shared publications - Poulami Barman
Verily Life Sci, South San Francisco, CA USA
6 shared publications - Alex Jan van 'T Hul
Department of Pulmonary Diseases, Radboud University Medical Center, 6525 GA, Nijmegen, The Netherlands
4 shared publications - Bastiaan R. Bloem
Department of Neurology, Centre of Expertise for Parkinson and Movement Disorders, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Centre, Nijmegen, The Netherlands
4 shared publications - Debbie de Graaf
Donders Institute for Brain, Cognition and Behavior, Department of Neurology, Center of Expertise for Parkinson and Movement Disorders, R914, Radboud University Medical Center, Postbus 9101, 6500 HB, Nijmegen, The Netherlands.
4 shared publications
Latest Publications
- Open Access
- 12 May 2026
- Published by Wiley in Annals of Neurology
- Vol. 100 (2) , 282-294
Daily‐Life, Sensor‐Derived Tremor Measures Are Sensitive to Progression in Early Parkinson's Disease
Objective: Sensitive outcome measures are critical for evaluating the efficacy of novel treatments for Parkinson's disease (PD). In this study, we assess the sensitivity to change of sensor‐derived daily‐life tremor measures over 2 years in unmedicated and medicated persons with early PD. Methods: We used 2‐year continuous wrist sensor data (median wear time: 22 hours/day) from the Personalized Parkinson Project (n = 462 medicated; n = 78 unmedicated at baseline), in combination with annual clinical evaluations of tremor severity. From the gyroscope data, we derived previously validated weekly measures for tremor time and power, which were smoothed over time using piecewise linear trend estimation. One‐ and 2‐year standardized response means (SRMs) were computed to compare the sensitivity to change between the sensor‐derived tremor measures and clinical tremor scores. Results: In unmedicated participants with tremor, sensor‐derived tremor measures demonstrated a high sensitivity to progression (2‐year SRMs ranged from 0.67 to 1.09), which was significantly larger than clinical tremor scores (2‐year SRMs ranged from 0.21 to 0.41). In medicated participants, sensor‐derived tremor time decreased (2‐year SRM of −0.18), which was associated with both an increase in dopaminergic medication dose and higher disease duration. In contrast, the sensor‐derived tremor power measures and clinical rest tremor scores (measured in the OFF state) increased slightly (2‐year SRMs ranging from 0.11 to 0.27). Interpretation: Before initiation of symptomatic treatment, sensor‐derived daily‐life tremor measures are substantially more sensitive to progression than clinical tremor scores, making them a promising tool to evaluate the efficacy of disease‐modifying treatments in early PD. ANN NEUROL 2026
- 12 May 2026
- Published by Wiley in Annals of Neurology
- Vol. 100 (2) , 282-294
Open AccessDaily‐Life, Sensor‐Derived Tremor Measures Are Sensitive to Progression in Early Parkinson's Disease
Objective: Sensitive outcome measures are critical for evaluating the efficacy of novel treatments for Parkinson's disease (PD). In this study, we assess the sensitivity to change of sensor‐derived daily‐life tremor measures over 2 years in unmedicated and medicated persons with early PD. Methods: We used 2‐year continuous wrist sensor data (median wear time: 22 hours/day) from the Personalized Parkinson Project (n = 462 medicated; n = 78 unmedicated at baseline), in combination with annual clinical evaluations of tremor severity. From the gyroscope data, we derived previously validated weekly measures for tremor time and power, which were smoothed over time using piecewise linear trend estimation. One‐ and 2‐year standardized response means (SRMs) were computed to compare the sensitivity to change between the sensor‐derived tremor measures and clinical tremor scores. Results: In unmedicated participants with tremor, sensor‐derived tremor measures demonstrated a high sensitivity to progression (2‐year SRMs ranged from 0.67 to 1.09), which was significantly larger than clinical tremor scores (2‐year SRMs ranged from 0.21 to 0.41). In medicated participants, sensor‐derived tremor time decreased (2‐year SRM of −0.18), which was associated with both an increase in dopaminergic medication dose and higher disease duration. In contrast, the sensor‐derived tremor power measures and clinical rest tremor scores (measured in the OFF state) increased slightly (2‐year SRMs ranging from 0.11 to 0.27). Interpretation: Before initiation of symptomatic treatment, sensor‐derived daily‐life tremor measures are substantially more sensitive to progression than clinical tremor scores, making them a promising tool to evaluate the efficacy of disease‐modifying treatments in early PD. ANN NEUROL 2026
- Open Access
- 9 December 2024
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 13 (1) , e68647
Correction: Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study
In “Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study” (JMIR Res Protoc 2024 May 7:13:e55452) the authors noticed that one of the authors was not named correctly.
- 9 December 2024
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 13 (1) , e68647
Open AccessCorrection: Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study
In “Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study” (JMIR Res Protoc 2024 May 7:13:e55452) the authors noticed that one of the authors was not named correctly.
- Open Access
- 11 November 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Correction: Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study (Preprint)
UNSTRUCTURED In “Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study” (JMIR Res Protoc 2024 May 7:13:e55452) the authors noticed that one of the authors was not named correctly.
- 11 November 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessCorrection: Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study (Preprint)
UNSTRUCTURED In “Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study” (JMIR Res Protoc 2024 May 7:13:e55452) the authors noticed that one of the authors was not named correctly.
- Open Access
- 10 October 2024
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 26, e62769
Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis
Background: Photoplethysmography (PPG) is a technology routinely used in clinical practice to assess blood oxygenation (SpO2) and pulse rate (PR). Skin pigmentation may influence accuracy, leading to health outcomes disparities. Objective: This systematic review and meta-analysis primarily aimed to evaluate the accuracy of PPG-derived SpO2 and PR by skin pigmentation. Secondarily, we aimed to evaluate statistical biases and the clinical relevance of PPG-derived SpO2 and PR according to skin pigmentation. Methods: We identified 23 pulse oximetry studies (n=59,684; 197,353 paired SpO2-arterial blood observations) and 4 wearable PR studies (n=176; 140,771 paired PPG-electrocardiography observations). We evaluated accuracy according to skin pigmentation group by comparing SpO2 accuracy root-mean-square values to the regulatory threshold of 3% and PR 95% limits of agreement values to +5 or –5 beats per minute (bpm), according to the standards of the American National Standards Institute, Association for the Advancement of Medical Instrumentation, and the International Electrotechnical Commission. We evaluated biases and clinical relevance using mean bias and 95% CI. Results: For SpO2, accuracy root-mean-square values were 3.96%, 4.71%, and 4.15%, and pooled mean biases were 0.70% (95% CI 0.17%-1.22%), 0.27% (95% CI –0.64% to 1.19%), and 1.27% (95% CI 0.58%-1.95%) for light, medium, and dark pigmentation, respectively. For PR, 95% limits of agreement values were from –16.02 to 13.54, from –18.62 to 16.84, and from –33.69 to 32.54, and pooled mean biases were –1.24 (95% CI –5.31 to 2.83) bpm, –0.89 (95% CI –3.70 to 1.93) bpm, and –0.57 (95% CI –9.44 to 8.29) bpm for light, medium, and dark pigmentation, respectively. Conclusions: SpO2 and PR measurements may be inaccurate across all skin pigmentation groups, breaching U.S. Food and Drug Administration guidance and industry standard thresholds. Pulse oximeters significantly overestimate SpO2 for both light and dark skin pigmentation, but this overestimation may not be clinically relevant. PRs obtained from wearables exhibit no statistically or clinically significant bias based on skin pigmentation.
- 10 October 2024
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 26, e62769
Open AccessImpact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis
Background: Photoplethysmography (PPG) is a technology routinely used in clinical practice to assess blood oxygenation (SpO2) and pulse rate (PR). Skin pigmentation may influence accuracy, leading to health outcomes disparities. Objective: This systematic review and meta-analysis primarily aimed to evaluate the accuracy of PPG-derived SpO2 and PR by skin pigmentation. Secondarily, we aimed to evaluate statistical biases and the clinical relevance of PPG-derived SpO2 and PR according to skin pigmentation. Methods: We identified 23 pulse oximetry studies (n=59,684; 197,353 paired SpO2-arterial blood observations) and 4 wearable PR studies (n=176; 140,771 paired PPG-electrocardiography observations). We evaluated accuracy according to skin pigmentation group by comparing SpO2 accuracy root-mean-square values to the regulatory threshold of 3% and PR 95% limits of agreement values to +5 or –5 beats per minute (bpm), according to the standards of the American National Standards Institute, Association for the Advancement of Medical Instrumentation, and the International Electrotechnical Commission. We evaluated biases and clinical relevance using mean bias and 95% CI. Results: For SpO2, accuracy root-mean-square values were 3.96%, 4.71%, and 4.15%, and pooled mean biases were 0.70% (95% CI 0.17%-1.22%), 0.27% (95% CI –0.64% to 1.19%), and 1.27% (95% CI 0.58%-1.95%) for light, medium, and dark pigmentation, respectively. For PR, 95% limits of agreement values were from –16.02 to 13.54, from –18.62 to 16.84, and from –33.69 to 32.54, and pooled mean biases were –1.24 (95% CI –5.31 to 2.83) bpm, –0.89 (95% CI –3.70 to 1.93) bpm, and –0.57 (95% CI –9.44 to 8.29) bpm for light, medium, and dark pigmentation, respectively. Conclusions: SpO2 and PR measurements may be inaccurate across all skin pigmentation groups, breaching U.S. Food and Drug Administration guidance and industry standard thresholds. Pulse oximeters significantly overestimate SpO2 for both light and dark skin pigmentation, but this overestimation may not be clinically relevant. PRs obtained from wearables exhibit no statistically or clinically significant bias based on skin pigmentation.
- Open Access
- 4 June 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis (Preprint)
BACKGROUND Photoplethysmography (PPG) is a technology routinely used in clinical practice to assess blood oxygenation (SpO2) and pulse rate (PR). Skin pigmentation may influence accuracy, leading to health outcomes disparities. OBJECTIVE This systematic review and meta-analysis primarily aimed to evaluate the accuracy of PPG-derived SpO2 and PR by skin pigmentation. Secondarily, we aimed to evaluate statistical biases and the clinical relevance of PPG-derived SpO2 and PR according to skin pigmentation. METHODS We identified 23 pulse oximetry studies (n=59,684; 197,353 paired SpO2-arterial blood observations) and 4 wearable PR studies (n=176; 140,771 paired PPG-electrocardiography observations). We evaluated accuracy according to skin pigmentation group by comparing SpO2 accuracy root-mean-square values to the regulatory threshold of 3% and PR 95% limits of agreement values to +5 or –5 beats per minute (bpm), according to the standards of the American National Standards Institute, Association for the Advancement of Medical Instrumentation, and the International Electrotechnical Commission. We evaluated biases and clinical relevance using mean bias and 95% CI. RESULTS For SpO2, accuracy root-mean-square values were 3.96%, 4.71%, and 4.15%, and pooled mean biases were 0.70% (95% CI 0.17%-1.22%), 0.27% (95% CI –0.64% to 1.19%), and 1.27% (95% CI 0.58%-1.95%) for light, medium, and dark pigmentation, respectively. For PR, 95% limits of agreement values were from –16.02 to 13.54, from –18.62 to 16.84, and from –33.69 to 32.54, and pooled mean biases were –1.24 (95% CI –5.31 to 2.83) bpm, –0.89 (95% CI –3.70 to 1.93) bpm, and –0.57 (95% CI –9.44 to 8.29) bpm for light, medium, and dark pigmentation, respectively. CONCLUSIONS SpO2 and PR measurements may be inaccurate across all skin pigmentation groups, breaching U.S. Food and Drug Administration guidance and industry standard thresholds. Pulse oximeters significantly overestimate SpO2 for both light and dark skin pigmentation, but this overestimation may not be clinically relevant. PRs obtained from wearables exhibit no statistically or clinically significant bias based on skin pigmentation.
- 4 June 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessImpact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis (Preprint)
BACKGROUND Photoplethysmography (PPG) is a technology routinely used in clinical practice to assess blood oxygenation (SpO2) and pulse rate (PR). Skin pigmentation may influence accuracy, leading to health outcomes disparities. OBJECTIVE This systematic review and meta-analysis primarily aimed to evaluate the accuracy of PPG-derived SpO2 and PR by skin pigmentation. Secondarily, we aimed to evaluate statistical biases and the clinical relevance of PPG-derived SpO2 and PR according to skin pigmentation. METHODS We identified 23 pulse oximetry studies (n=59,684; 197,353 paired SpO2-arterial blood observations) and 4 wearable PR studies (n=176; 140,771 paired PPG-electrocardiography observations). We evaluated accuracy according to skin pigmentation group by comparing SpO2 accuracy root-mean-square values to the regulatory threshold of 3% and PR 95% limits of agreement values to +5 or –5 beats per minute (bpm), according to the standards of the American National Standards Institute, Association for the Advancement of Medical Instrumentation, and the International Electrotechnical Commission. We evaluated biases and clinical relevance using mean bias and 95% CI. RESULTS For SpO2, accuracy root-mean-square values were 3.96%, 4.71%, and 4.15%, and pooled mean biases were 0.70% (95% CI 0.17%-1.22%), 0.27% (95% CI –0.64% to 1.19%), and 1.27% (95% CI 0.58%-1.95%) for light, medium, and dark pigmentation, respectively. For PR, 95% limits of agreement values were from –16.02 to 13.54, from –18.62 to 16.84, and from –33.69 to 32.54, and pooled mean biases were –1.24 (95% CI –5.31 to 2.83) bpm, –0.89 (95% CI –3.70 to 1.93) bpm, and –0.57 (95% CI –9.44 to 8.29) bpm for light, medium, and dark pigmentation, respectively. CONCLUSIONS SpO2 and PR measurements may be inaccurate across all skin pigmentation groups, breaching U.S. Food and Drug Administration guidance and industry standard thresholds. Pulse oximeters significantly overestimate SpO2 for both light and dark skin pigmentation, but this overestimation may not be clinically relevant. PRs obtained from wearables exhibit no statistically or clinically significant bias based on skin pigmentation.
- Open Access
- 7 May 2024
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 13 (1) , e55452
Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study
Background: Physical capacity and physical activity are important aspects of physical functioning and quality of life in people with a chronic disease such as Parkinson disease (PD) or chronic obstructive pulmonary disease (COPD). Both physical capacity and physical activity are currently measured in the clinic using standardized questionnaires and tests, such as the 6-minute walk test (6MWT) and the Timed Up and Go test (TUG). However, relying only on in-clinic tests is suboptimal since they offer limited information on how a person functions in daily life and how functioning fluctuates throughout the day. Wearable sensor technology may offer a solution that enables us to better understand true physical functioning in daily life. Objective: We aim to study whether device-assisted versions of 6MWT and TUG, such that the tests can be performed independently at home using a smartwatch, is a valid and reliable way to measure the performance compared to a supervised, in-clinic test. Methods: This is a decentralized, prospective, observational study including 100 people with PD and 100 with COPD. The inclusion criteria are broad: age ≥18 years, able to walk independently, and no co-occurrence of PD and COPD. Participants are followed for 15 weeks with 4 in-clinic visits, once every 5 weeks. Outcomes include several walking tests, cognitive tests, and disease-specific questionnaires accompanied by data collection using wearable devices (the Verily Study Watch and Modus StepWatch). Additionally, during the last 10 weeks of this study, participants will follow an aerobic exercise training program aiming to increase physical capacity, creating the opportunity to study the responsiveness of the remote 6MWT. Results: In total, 89 people with PD and 65 people with COPD were included in this study. Data analysis will start in April 2024. Conclusions: The results of this study will provide information on the measurement properties of the device-assisted 6MWT and TUG in the clinic and at home. When reliable and valid, this can contribute to a better understanding of a person’s physical capacity in real life, which makes it possible to personalize treatment options. Trial Registration: ClinicalTrials.gov NCT05756075; https://clinicaltrials.gov/study/NCT05756075 International Registered Report Identifier (IRRID): DERR1-10.2196/55452
- 7 May 2024
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 13 (1) , e55452
Open AccessMeasuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study
Background: Physical capacity and physical activity are important aspects of physical functioning and quality of life in people with a chronic disease such as Parkinson disease (PD) or chronic obstructive pulmonary disease (COPD). Both physical capacity and physical activity are currently measured in the clinic using standardized questionnaires and tests, such as the 6-minute walk test (6MWT) and the Timed Up and Go test (TUG). However, relying only on in-clinic tests is suboptimal since they offer limited information on how a person functions in daily life and how functioning fluctuates throughout the day. Wearable sensor technology may offer a solution that enables us to better understand true physical functioning in daily life. Objective: We aim to study whether device-assisted versions of 6MWT and TUG, such that the tests can be performed independently at home using a smartwatch, is a valid and reliable way to measure the performance compared to a supervised, in-clinic test. Methods: This is a decentralized, prospective, observational study including 100 people with PD and 100 with COPD. The inclusion criteria are broad: age ≥18 years, able to walk independently, and no co-occurrence of PD and COPD. Participants are followed for 15 weeks with 4 in-clinic visits, once every 5 weeks. Outcomes include several walking tests, cognitive tests, and disease-specific questionnaires accompanied by data collection using wearable devices (the Verily Study Watch and Modus StepWatch). Additionally, during the last 10 weeks of this study, participants will follow an aerobic exercise training program aiming to increase physical capacity, creating the opportunity to study the responsiveness of the remote 6MWT. Results: In total, 89 people with PD and 65 people with COPD were included in this study. Data analysis will start in April 2024. Conclusions: The results of this study will provide information on the measurement properties of the device-assisted 6MWT and TUG in the clinic and at home. When reliable and valid, this can contribute to a better understanding of a person’s physical capacity in real life, which makes it possible to personalize treatment options. Trial Registration: ClinicalTrials.gov NCT05756075; https://clinicaltrials.gov/study/NCT05756075 International Registered Report Identifier (IRRID): DERR1-10.2196/55452
- Open Access
- 18 April 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 13
Lesions in a songbird vocal circuit increase variability in song syntax
Complex skills like speech and dance are composed of ordered sequences of simpler elements, but the neuronal basis for the syntactic ordering of actions is poorly understood. Birdsong is a learned vocal behavior composed of syntactically ordered syllables, controlled in part by the songbird premotor nucleus HVC (proper name). Here, we test whether one of HVC’s recurrent inputs, mMAN (medial magnocellular nucleus of the anterior nidopallium), contributes to sequencing in adult male Bengalese finches (Lonchura striata domestica). Bengalese finch song includes several patterns: (1) chunks, comprising stereotyped syllable sequences; (2) branch points, where a given syllable can be followed probabilistically by multiple syllables; and (3) repeat phrases, where individual syllables are repeated variable numbers of times. We found that following bilateral lesions of mMAN, acoustic structure of syllables remained largely intact, but sequencing became more variable, as evidenced by ‘breaks’ in previously stereotyped chunks, increased uncertainty at branch points, and increased variability in repeat numbers. Our results show that mMAN contributes to the variable sequencing of vocal elements in Bengalese finch song and demonstrate the influence of recurrent projections to HVC. Furthermore, they highlight the utility of species with complex syntax in investigating neuronal control of ordered sequences.
- 18 April 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 13
Open AccessLesions in a songbird vocal circuit increase variability in song syntax
Complex skills like speech and dance are composed of ordered sequences of simpler elements, but the neuronal basis for the syntactic ordering of actions is poorly understood. Birdsong is a learned vocal behavior composed of syntactically ordered syllables, controlled in part by the songbird premotor nucleus HVC (proper name). Here, we test whether one of HVC’s recurrent inputs, mMAN (medial magnocellular nucleus of the anterior nidopallium), contributes to sequencing in adult male Bengalese finches (Lonchura striata domestica). Bengalese finch song includes several patterns: (1) chunks, comprising stereotyped syllable sequences; (2) branch points, where a given syllable can be followed probabilistically by multiple syllables; and (3) repeat phrases, where individual syllables are repeated variable numbers of times. We found that following bilateral lesions of mMAN, acoustic structure of syllables remained largely intact, but sequencing became more variable, as evidenced by ‘breaks’ in previously stereotyped chunks, increased uncertainty at branch points, and increased variability in repeat numbers. Our results show that mMAN contributes to the variable sequencing of vocal elements in Bengalese finch song and demonstrate the influence of recurrent projections to HVC. Furthermore, they highlight the utility of species with complex syntax in investigating neuronal control of ordered sequences.
- Open Access
- 4 April 2024
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 30 (11) , 1423-1433
Real-world walking behaviors are associated with early-stage heart failure: a Project Baseline Health Study
- 4 April 2024
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 30 (11) , 1423-1433
Open AccessReal-world walking behaviors are associated with early-stage heart failure: a Project Baseline Health Study
- Open Access
- 21 March 2024
- Published by eLife Sciences Publications, Ltd in eLife preprints
- Vol. 13
Lesions in a songbird vocal circuit increase variability in song syntax
Complex motor skills like speech and dance are composed of ordered sequences of simpler elements, but the neuronal basis for syntactic ordering of individual actions into sequences is poorly understood. Birdsong is a learned vocal behavior composed of syntactically ordered sequences of individual syllables. Activity in song premotor nucleus HVC (proper name) has been linked to the control of syllable sequencing, but sequencing may also be affected by its recurrent inputs. We here test the contribution of one of HVC’s inputs, mMAN (medial magnocellular nucleus of the anterior nidopallium), to the variable songs of adult male Bengalese finches (Lonchura striata domestica). The syntax of Bengalese song includes several patterns: 1) chunks, where syllables follow stereotypical order 2) branch points, where a given syllable can be followed by two or more different syllables in a probabilistic manner and 3) repeat phrases, where an individual syllable is repeated a variable number of times. We found that after bilateral lesions of mMAN, the acoustic structure of syllables remained largely intact, but sequencing became more variable for each of these patterns, seen by ‘breaks’ in previously stereotyped chunks, increased uncertainty at branch points and increased variability of repeat numbers. This increase in sequencing variability highlights the potential importance of regions projecting to HVC in the ordering of vocal elements. Previous studies on zebra finches found little effect of mMAN lesions on their relatively stereotyped adult song. In contrast, our results suggest that mMAN contributes to sequencing the variable songs of Bengalese finches and highlight the utility of species with more complex song syntax in investigating neuronal control of ordered motor sequences.
- 21 March 2024
- Published by eLife Sciences Publications, Ltd in eLife preprints
- Vol. 13
Open AccessLesions in a songbird vocal circuit increase variability in song syntax
Complex motor skills like speech and dance are composed of ordered sequences of simpler elements, but the neuronal basis for syntactic ordering of individual actions into sequences is poorly understood. Birdsong is a learned vocal behavior composed of syntactically ordered sequences of individual syllables. Activity in song premotor nucleus HVC (proper name) has been linked to the control of syllable sequencing, but sequencing may also be affected by its recurrent inputs. We here test the contribution of one of HVC’s inputs, mMAN (medial magnocellular nucleus of the anterior nidopallium), to the variable songs of adult male Bengalese finches (Lonchura striata domestica). The syntax of Bengalese song includes several patterns: 1) chunks, where syllables follow stereotypical order 2) branch points, where a given syllable can be followed by two or more different syllables in a probabilistic manner and 3) repeat phrases, where an individual syllable is repeated a variable number of times. We found that after bilateral lesions of mMAN, the acoustic structure of syllables remained largely intact, but sequencing became more variable for each of these patterns, seen by ‘breaks’ in previously stereotyped chunks, increased uncertainty at branch points and increased variability of repeat numbers. This increase in sequencing variability highlights the potential importance of regions projecting to HVC in the ordering of vocal elements. Previous studies on zebra finches found little effect of mMAN lesions on their relatively stereotyped adult song. In contrast, our results suggest that mMAN contributes to sequencing the variable songs of Bengalese finches and highlight the utility of species with more complex song syntax in investigating neuronal control of ordered motor sequences.
- Open Access
- 13 December 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Measuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study (Preprint)
BACKGROUND Physical capacity and physical activity are important aspects of physical functioning and quality of life in people with a chronic disease such as Parkinson disease (PD) or chronic obstructive pulmonary disease (COPD). Both physical capacity and physical activity are currently measured in the clinic using standardized questionnaires and tests, such as the 6-minute walk test (6MWT) and the Timed Up and Go test (TUG). However, relying only on in-clinic tests is suboptimal since they offer limited information on how a person functions in daily life and how functioning fluctuates throughout the day. Wearable sensor technology may offer a solution that enables us to better understand true physical functioning in daily life. OBJECTIVE We aim to study whether device-assisted versions of 6MWT and TUG, such that the tests can be performed independently at home using a smartwatch, is a valid and reliable way to measure the performance compared to a supervised, in-clinic test. METHODS This is a decentralized, prospective, observational study including 100 people with PD and 100 with COPD. The inclusion criteria are broad: age ≥18 years, able to walk independently, and no co-occurrence of PD and COPD. Participants are followed for 15 weeks with 4 in-clinic visits, once every 5 weeks. Outcomes include several walking tests, cognitive tests, and disease-specific questionnaires accompanied by data collection using wearable devices (the Verily Study Watch and Modus StepWatch). Additionally, during the last 10 weeks of this study, participants will follow an aerobic exercise training program aiming to increase physical capacity, creating the opportunity to study the responsiveness of the remote 6MWT. RESULTS In total, 89 people with PD and 65 people with COPD were included in this study. Data analysis will start in April 2024. CONCLUSIONS The results of this study will provide information on the measurement properties of the device-assisted 6MWT and TUG in the clinic and at home. When reliable and valid, this can contribute to a better understanding of a person’s physical capacity in real life, which makes it possible to personalize treatment options. CLINICALTRIAL ClinicalTrials.gov NCT05756075; https://clinicaltrials.gov/study/NCT05756075 INTERNATIONAL REGISTERED REPORT DERR1-10.2196/55452
- 13 December 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessMeasuring Physical Functioning Using Wearable Sensors in Parkinson Disease and Chronic Obstructive Pulmonary Disease (the Accuracy of Digital Assessment of Performance Trial Study): Protocol for a Prospective Observational Study (Preprint)
BACKGROUND Physical capacity and physical activity are important aspects of physical functioning and quality of life in people with a chronic disease such as Parkinson disease (PD) or chronic obstructive pulmonary disease (COPD). Both physical capacity and physical activity are currently measured in the clinic using standardized questionnaires and tests, such as the 6-minute walk test (6MWT) and the Timed Up and Go test (TUG). However, relying only on in-clinic tests is suboptimal since they offer limited information on how a person functions in daily life and how functioning fluctuates throughout the day. Wearable sensor technology may offer a solution that enables us to better understand true physical functioning in daily life. OBJECTIVE We aim to study whether device-assisted versions of 6MWT and TUG, such that the tests can be performed independently at home using a smartwatch, is a valid and reliable way to measure the performance compared to a supervised, in-clinic test. METHODS This is a decentralized, prospective, observational study including 100 people with PD and 100 with COPD. The inclusion criteria are broad: age ≥18 years, able to walk independently, and no co-occurrence of PD and COPD. Participants are followed for 15 weeks with 4 in-clinic visits, once every 5 weeks. Outcomes include several walking tests, cognitive tests, and disease-specific questionnaires accompanied by data collection using wearable devices (the Verily Study Watch and Modus StepWatch). Additionally, during the last 10 weeks of this study, participants will follow an aerobic exercise training program aiming to increase physical capacity, creating the opportunity to study the responsiveness of the remote 6MWT. RESULTS In total, 89 people with PD and 65 people with COPD were included in this study. Data analysis will start in April 2024. CONCLUSIONS The results of this study will provide information on the measurement properties of the device-assisted 6MWT and TUG in the clinic and at home. When reliable and valid, this can contribute to a better understanding of a person’s physical capacity in real life, which makes it possible to personalize treatment options. CLINICALTRIAL ClinicalTrials.gov NCT05756075; https://clinicaltrials.gov/study/NCT05756075 INTERNATIONAL REGISTERED REPORT DERR1-10.2196/55452