Hsu-Pin Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hsu-Pin Pan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Cheng-Kung Cheng
Department of Biomedical Engineering, National Yang-Ming University, Linong St, Beitou District, Taipei City, Taiwan
1 shared publication - Chih-Sheng Yu
Instrument Technology Research Center, National Applied Research Laboratories 20, R&D Rd. VI, Hsinchu Science Park, Hsinchu 300, Taiwan
1 shared publication - Chih-Yu Chen
Taipei Medical University
1 shared publication - Fan-Chun Hsieh
Instrument Technology Research Center, National Applied Research Laboratories 20, R&D Rd. VI, Hsinchu Science Park, Hsinchu 300, Taiwan
1 shared publication - Feng-Huei Lin
Department of Biomedical Engineering National Taiwan University Taipei Taiwan
1 shared publication - Jui-Sheng Sun
Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei, Taiwan
1 shared publication
Latest Publications
- 18 March 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 44 (1) , 73-78
Wing-augmentation reduces femoral head cutting out of dynamic hip screw
The dynamic hip screw (DHS) is commonly used in the treatment of femoral intertrochanteric fracture with high satisfactory results. However, post-operative failure does occur and result in poor prognosis. The most common failure is femoral head varus collapse, followed by lag screw cut-out through the femoral head. In this study, a novel-designed DHS with two supplemental horizontal blades was used to improve the fixation stability. In this study, nine convention DHS and 9 Orthopaedic Device Research Center (ODRC) DHSs were tested in this study. Each implant was fixed into cellular polyurethane rigid foam as a surrogate of osteoporotic femoral head. Under biaxial rocking motion, all constructs were loaded to failure point (12mm axial displacement) or up to 20,000 cycles of 1.45kN peak magnitude were achieved, whichever occurred first. The migration kinematics was continuously monitored and recorded. The final tip-to-apex distance, rotational angle and varus deformation were also recorded. The results showed that the ODRC DHS sustained significantly more loading cycles and exhibited less axial migration in comparison to the conventional DHS. The ODRC DHS showed a significantly smaller bending strain and larger torsional strain compared to the conventional DHS. The changes in tip-to-apex distance (TAD), post-study varus angle, post-study rotational angle of the ODRC DHS were all significantly less than that of the conventional DHS (p < 0.05). We concluded that the ODRC DHS augmented with two horizontal wings would increase the bone-implant interface contact surface, dissipate the load to the screw itself, which improves the migration resistance and increases the anti-rotational implant effect. In conclusion, the proposed ODRC DHS demonstrated significantly better migration resistance and anti-rotational effect in comparison to the conventional DHS construct.
- 18 March 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 44 (1) , 73-78
Wing-augmentation reduces femoral head cutting out of dynamic hip screw
The dynamic hip screw (DHS) is commonly used in the treatment of femoral intertrochanteric fracture with high satisfactory results. However, post-operative failure does occur and result in poor prognosis. The most common failure is femoral head varus collapse, followed by lag screw cut-out through the femoral head. In this study, a novel-designed DHS with two supplemental horizontal blades was used to improve the fixation stability. In this study, nine convention DHS and 9 Orthopaedic Device Research Center (ODRC) DHSs were tested in this study. Each implant was fixed into cellular polyurethane rigid foam as a surrogate of osteoporotic femoral head. Under biaxial rocking motion, all constructs were loaded to failure point (12mm axial displacement) or up to 20,000 cycles of 1.45kN peak magnitude were achieved, whichever occurred first. The migration kinematics was continuously monitored and recorded. The final tip-to-apex distance, rotational angle and varus deformation were also recorded. The results showed that the ODRC DHS sustained significantly more loading cycles and exhibited less axial migration in comparison to the conventional DHS. The ODRC DHS showed a significantly smaller bending strain and larger torsional strain compared to the conventional DHS. The changes in tip-to-apex distance (TAD), post-study varus angle, post-study rotational angle of the ODRC DHS were all significantly less than that of the conventional DHS (p < 0.05). We concluded that the ODRC DHS augmented with two horizontal wings would increase the bone-implant interface contact surface, dissipate the load to the screw itself, which improves the migration resistance and increases the anti-rotational implant effect. In conclusion, the proposed ODRC DHS demonstrated significantly better migration resistance and anti-rotational effect in comparison to the conventional DHS construct.